Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Structure and lattice excitations of the copper substituted lead oxyapatite Pb 9.06⁢(7)⁢ Cu 0.94⁢(6)⁢ (PO 3.92⁢(4) ) 6 ⁢O 0.96⁢(3)

The copper substituted lead oxyapatite, Pb 10-x⁢ Cu x (PO 3.92⁢(4) ) 6 ⁢O 0.96⁢(3) [x = 0.94(6)] was studied using neutron and x-ray diffraction and neutron spectroscopy techniques. The crystal structure of the main phase of our sample, which has come to be colloquially known as LK-99, is verified to possess a hexagonal structure with space group P6 3 /m, alongside the presence of impurity phases Cu and Cu 2 ⁢S. We determine the primary substitution location of the Cu as the Pb1 (6⁢ℎ) site, with a small substitution at the Pb2 (4⁢f) site. Consequently, no clear Cu-doping-induced structural distortion was observed in the investigated temperature region between 10 K and 300 K. Specially, we did not observe a reduction of coordinate number at the Pb2 site or a clear tilting of PO 4 tetrahedron. Magnetic characterization reveals a diamagnetic signal in the specimen, accompanied by a very weak ferromagnetic component at 2 K. No long-range magnetic order down to 10 K was detected by the neutron diffraction. Inelastic neutron scattering measurements did not show magnetic excitations for energies up to 350 meV. There is no sign of a superconducting resonance in the excitation spectrum of this material. The measured phonon density of states compares well with density functional theory calculations performed for the main LK-99 phase and its impurity phases. Our study may shed some insight into the role of the favored substitution site of copper in the absence of structural distortion and superconductivity in LK-99.

36 MATERIALS SCIENCE↗

The role of momentum transfer during incoherent neutron scattering is explained by the energy landscape model

Significance Quasielastic neutron scattering (QENS) has been used for > 40 y to study complex systems. Fascinating questions remain. The neutron has to be a de Broglie wave packet to obtain dynamics information on biological systems. During its interaction with a proton in a protein, the wave packet puts pressure on the proton and its environment. The protein acts like an ideal spring and by Hooke’s law transiently stores the energy produced by the pressure. On leaving, the wave packet regains essentially the full energy. However, during the passage, fluctuations in the sample change the neutron energy slightly and broaden the energy spectrum. The results call for a reexamination of the theory of quasielastic neutron scattering from complex systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Hydrogen Content Graphene Hydride Compounds & High Cross-­ Section Cladding Coatings for Fast Neutron Detection

The objective is to develop and implement a superior low-cost, large area (potentially >32in), easily deployable, close proximity, harsh environment innovative neutron sensor needed for next generation fuel cycle monitoring. We will exploit recent breakthroughs at the PI’s lab on the electrochemistry of epitaxial graphene (EG) formed on commercial SiC wafers, a transformative nanomaterial system with superior radiation detection and durability properties to develop a new paradigm in detection for fast neutrons, a by-product of fission reactors. There are currently few effective detection/monitoring schemes, especially solid-state ones at present. This is essential for monitoring and control of future fuel cycles to make them more efficient and reliable. By exploiting these novel materials, as well as innovative hybrid SiC/EG/Cladding device architectures conceived by the team, will develop low-cost, high performance solutions to fast-neutron detection. Finally, we will also explore 3-terminal device implementations for neutron detectors with built-in electronic gain to further shrink these devices and improve their sensitivity.

36 MATERIALS SCIENCE↗

SEEMS: A Single Event Effects and Muon Spectroscopy facility at the Spallation Neutron Source

This study outlines a concept that would leverage the existing proton accelerator at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory to enable transformative science via one world-class facility serving two missions: Single Event Effects (SEE) and Muon Spectroscopy (μSR). The μSR portion would deliver the world’s highest flux and highest resolution pulsed muon beams for material characterization purposes, with precision and capabilities well beyond comparable facilities. The SEE capabilities deliver neutron, proton, and muon beams for aerospace industries that are facing an impending challenge to certify equipment for safe and reliable behavior under bombardment from atmospheric radiation originating from cosmic and solar rays. With negligible impact on the primary neutron scattering mission of the SNS, the proposed facility will have enormous benefits for both science and industry. Herein, we have designated this facility “SEEMS.”

47 OTHER INSTRUMENTATION↗

Chemical stability and Ce doping of LiMgAlF 6 neutron scintillator

We perform density functional calculations to investigate LiMgAlF 6 as a potential neutron scintillator material. The calculations of enthalpy of formation and phase diagram show that single-phase LiMgAlF 6 can be grown but it should be more difficult than growing LiCaAlF 6 and LiSrAlF 6 . Moreover, the formation energy calculations for substitutional Ce show that the concentration of Ce on the Al site is negligible but a high concentration (>1 at.%) of Ce on the Mg site is attainable provided that the Fermi level is more than 5 eV lower than the conduction band minimum. Acceptor doping should promote Ce incorporation in LiMgAlF 6 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effects of Manufacturing Techniques on Neutron-Irradiated C26M Mechanical Properties

Nuclear energy provides 13% of the total energy produced globally. To further improve the safety and reliability of nuclear reactors material challenges need to be successfully resolved. C26M/FeCrAl alloy systems can improve the safety and reliability of current Generation III reactors due to the potential benefits of a stable passivation layer from the Al, which can protect against corrosion, and promising mechanical performance at boiling- and light-water reactor temperatures. However, information is limited on how manufacturing techniques affect the mechanical performance of C26M in neutron-irradiated environments. In this research, C26M specimens were manufactured using three techniques and then irradiated at the Advanced Test Reactor at Idaho National Laboratory. This research aims to bridge this gap by investigating how the manufacturing techniques affects the mechanical performance of irradiated C26M at Generation III reactor relevant temperatures.

36 - MATERIALS SCIENCE↗

Preliminary Modeling to Support the TREAT Hodoscope System for Fuel Motion Monitoring

Fuel motion is monitored in real time at the Transient Reactor Test Facility (TREAT) using a direct-viewing hodoscope that monitors fast neutrons emitted from test fuel undergoing fission during transients. The hodoscope system is now being refurbished, after over twenty years, to once again support research and development activities examining the survival and failure modes of advanced nuclear reactor fuel systems under accident conditions. An im-portant part of this activity is the development of high-fidelity modeling tools to predict the hodoscope's response to different fuel systems, in different test vehicles, throughout different transient cycles. Initial work has involved the collection of archival data related to how the hodoscope currently at TREAT was manufactured and installed, and the use of this data to create a preliminary radiation transport model using MCNP6. This model is now undergoing refinement to improve its fidelity and to permit its integration with other tools under development to model TREAT transients. The model will be used to study how fast-neutrons measured in the hodoscope's detectors relate to the fission of nuclear material in a test vehicle as a function of location within the vehicle and reactor power. The goal is to develop a time-dependent coupling factor that will relate the measured data to the fuel mass present within each pixel of the hodoscope's field of view. This paper will present the current status of the TREAT hodoscope refurbishment program and modeling activities related to interpreting hodoscope data and inferring fuel motion during transients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Neutron Interrogation as a Method for Verification of the Absence of Special Nuclear Material in Arms Control Dismantlement

The next step in arms control reductions will deal with both strategic and non-strategic weapons, presenting new and hard challenges for verification. One verification approach that might be used in support of these reductions is the concept of deferred verification, which forgoes inspections at sensitive nuclear sites and relies on an inspection regime having access to the open segment of a State's nuclear sector, in "monitored transfer zones." A component of this approach is the anticipated need for an instrument suite capable of detecting well-shielded highly-enriched uranium or plutonium where it isn't supposed to be. This specific need was recently identified by the United Nations Institute for Disarmament Research in an enabling operating concept they call "contain and dispose." At the foundation of this approach is the idea that items declared as "not nuclear" are, by definition, not treaty limited and are thus "fair-game" for inspection and questioning. Active Neutron Interrogation (ANI), using beta-delayed neutron emissions as the signature for special nuclear material (SNM) detection, is a promising method to address this challenge. The method is quick, has high sensitivity and high specificity for detecting shielded SNM, is robust against changing background radiation environments, is robust against the presence of unknown shielding, and avoids the use of gamma-ray spectrometry which may introduce complications due to the potential release of sensitive information. This paper will present recent research activities exploring technical aspects of using ANI as a FAIRGAME verification method and discuss future prospects and research needs

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Estimation of the Performance of Multiple Active Neutron Interrogation Signatures for Detecting Shielded HEU

A comprehensive modeling study has been carried out to evaluate the utility of multiple active neutron interrogation signatures for detecting shielded highly enriched uranium (HEU). The modeling effort focused on varying HEU masses from 1 kg to 20 kg; varying types of shields including wood, steel, cement, polyethylene, and borated polyethylene; varying depths of the HEU in the shields, and varying engineered shields immediately surrounding the HEU including steel, tungsten, and cadmium. Neutron and gamma-ray signatures were the focus of the study and false negative detection probabilities versus measurement time were used as a performance metric. To facilitate comparisons among different approaches an automated method was developed to generate receiver operating characteristic (ROC) curves for different sets of model variables for multiple background count rate conditions. This paper summarizes results or the analysis, including laboratory benchmark comparisons between simulations and experiments. The important impact engineered shields can play towards degrading detectability and methods for mitigating this will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of tempering behavior of lath martensite using in situ neutron diffraction

To elucidate changes in the density and substructure of dislocations during tempering of lath martensite steel, a convolutional multiple whole-profile fitting method was applied to in situ neutron diffraction profiles. With increasing tempering temperature, the dislocation density scarcely changed in the beginning and then decreased at temperatures above 473 K, whereas the dislocation arrangement drastically changed at temperatures above 673 K. The strength of the steel is speculated to depend on the density and arrangement of dislocations. - Highlights: • A convolutional multiple whole-profile fitting method was applied. • Dislocation density and dislocation arrangement changing with tempering were discussed. • Dislocation density scarcely changed in the beginning. • And then dislocation density decreased at temperatures above 473 K. • The dislocation arrangement drastically changed at temperatures above 673 K.

36 MATERIALS SCIENCE↗

Measurement of neutron capture cross section of Li-7 at J-PARC / MLF / ANNRI

We have measured the {sup 7}Li(n,γ){sup 8}Li reaction at Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) installed at the Material and Life science experimental Facility in the Japan Proton Accelerator Research Complex (J-PARC / MLF). In this experiment, we used intense pulsed neutron beam provided by J-PARC / MLF and high performance Ge spectrometer, which is one of the main detectors of the ANNRI. We clearly detected γ rays from the {sup 7}Li(n,γ){sup 8}Li reaction with sufficient signal-to-noise ratio.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemoradiotherapeutic wrinkled mesoporous silica nanoparticles for use in cancer therapy

Over the last decade, the development and application of nanotechnology in cancer detection, diagnosis, and therapy have been widely reported. Engineering of vehicles for the simultaneous delivery of chemo- and radiotherapeutics increases the effectiveness of the therapy and reduces the dosage of each individual drug required to produce an observable therapeutic response. We here developed a novel chemoradiotherapeutic 1,2-dioleoyl-sn-glycero-3-phosphocholine lipid coated/uncoated platinum drug loaded, holmium-containing, wrinkled mesoporous silica nanoparticle. The materials were characterized with TEM, FTIR, {sup 1}H NMR, energy dispersive x-ray, inductively coupled plasma-mass spectrometry, and zeta potential measurements. In vitro platinum drug release from both lipid coated and uncoated chemoradiotherapeutic wrinkled mesoporous silica are reported. Various kinetic models were used to analyze the release kinetics. The radioactivity of the chemoradiotherapeutic nanocarriers was measured after neutron-activation.

36 MATERIALS SCIENCE↗

Evolution and characterization of a new reversibly photoswitching chromogenic protein, Dathail

In this paper, we report the engineering of a new reversibly switching chromogenic protein, Dathail. Dathail was evolved from the extremely thermostable fluorescent proteins thermal green protein (TGP) and eCGP123 using directed evolution and ratiometric sorting. Dathail has two spectrally distinct chromogenic states with low quantum yields, corresponding to absorbance in a ground state with a maximum at 389 nm, and a photo-induced metastable state with a maximum at 497 nm. In contrast to all previously described photoswitchable proteins, both spectral states of Dathail are non-fluorescent. The photo-induced chromogenic state of Dathail has a lifetime of ~ 50 min at 293 K and pH 7.5 as measured by UV–Vis spectrophotometry, returning to the ground state through thermal relaxation. X-ray crystallography provided structural insights supporting a change in conformation and coordination in the chromophore pocket as being responsible for Dathail's photoswitching. Neutron crystallography, carried out for the first time on a protein from the green fluorescent protein family, showed a distribution of hydrogen atoms revealing protonation of the chromophore 4-hydroxybenzyl group in the ground state. Additionally, the neutron structure also supports the hypothesis that the photo-induced proton transfer from the chromophore occurs through water-mediated proton relay into the bulk solvent. Beyond its spectroscopic curiosity, Dathail has several characteristics that are improvements for applications, including low background fluorescence, large spectral separation, rapid switching time, and the ability to switch many times. Therefore, Dathail is likely to be extremely useful in the quickly developing fields of imaging and biosensors, including photochromic Förster resonance energy transfer, high-resolution microscopy, and live tracking within the cell.

59 BASIC BIOLOGICAL SCIENCES↗

Crystal structure of the $τ_{11}$ Al 4 Fe 1.7 Si phase from neutron diffraction and ab initio calculations

The intermetallic τ 11 Al 4 Fe 1.7 Si phase is of interest for high-temperature structural application due to its combination of low density and high strength. We determine the crystal structure of the τ 11 phase through a combination of powder neutron diffraction and density functional theory calculations. Using Pawley and Rietveld refinements of the neutron diffraction data provides an initial crystal structure model. Since Al and Si have nearly identical neutron scattering lengths, we use density-functional calculations to determine their preferred site occupations. The τ 11 phase exhibits a hexagonal crystal structure with space group P6 3 /mmc and lattice parameters of a = 7.478 Å and c = 7.472 Å. The structure comprises five Wyckoff positions; Al occupies the 6h and 12k sites, Fe the 2a and 6h sites, and Si the 2a sites. Here we observe site disorder and partial occupancies on all sites with a large fraction of 80% Fe vacancies on the 2d sites, indicating an entropic stabilization of the τ 11 phase at high temperature.

36 MATERIALS SCIENCE↗

Laser-assisted high-energy proton pulse extraction for feasibility study of co-located muon source at the SNS

Here, we have experimentally demonstrated the first non-intrusive 1-GeV proton beam extraction for the generation of muons with a temporal structure optimized for Muon Spin Relaxation/Rotation/Resonance (μSR) applications. The proton pulses are extracted based on the laser neutralization of 1 GeV hydrogen ion (H - ) beam in the high energy beam transport of the Spallation Neutron Source (SNS) accelerator. The maximum flux of the extracted proton beam based on laser neutralization causes only 0.2% reduction of the total proton beam used for neutron production, a marked difference from the 20% reduction at other co-located muon and neutron facilities, and thus the proposed method will result in negligible impact on the SNS operation. This paper describes the development of a fiber/solid-state hybrid laser system that has high flexibility of pulse structure and output power, initial experiments on laser neutralization of beam and separation of H 0 beam from the existing SNS accelerator beam line, conversion of H 0 to proton at the SNS linac dump, and measurement results of 30 ns/50 kHz proton pulses. This system conclusively demonstrates the feasibility of laser-based proton beam extraction to power a world-leading μSR facility at the SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype system for dynamically polarized neutron protein crystallography

The sensitivity of Neutron Macromolecular Crystallography to the presence of hydrogen makes it a powerful tool to complement X-ray crystallographic studies using protein crystals. The power of this technique is currently limited by the relative low neutron flux provided by even the most powerful neutron sources. The strong polarization dependence of the neutron scattering cross section of hydrogen will allow us to use Dynamic Nuclear Polarization to dramatically improve the signal to noise ratio of neutron diffraction data, delivering order of magnitude gains in performance, and enabling measurements of radically smaller crystals of larger protein systems than are possible today. Here, we present a prototype frozen spin system, built at Oak Ridge National Laboratory to polarize single protein crystals on the IMAGINE beamline at the High Flux Isotope Reactor (HFIR). Details of the design and construction will be described, as will the performance of the system offline and during preliminary tests at HFIR.

47 OTHER INSTRUMENTATION↗

CMR Shuffler System: Passive Mode Calibration and Certification Report

Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. As debris is removed from the vessels, material will be placed in waste drums. Far-field gamma ray assay will be used to determine when a drum is nearing a 239 Pu equivalent mass of less than 200 g. The drum will then be assayed using a waste drum shuffler operated in passive mode using a neutron coincidence counting method for accountability. This report focuses on the testing and calibration of the CMR waste drum shuffler in passive mode operation. Initial testing was performed to confirm previously accepted measurement parameters. The system was then calibrated using a set of weapons grade Pu (WGPu, 239 Pu > 93%) oxide standards placed inside a 55 gallon drum. The calibration data ranges from Pu mass of 0.5 g to 188.9 g. The CMR waste drum shuffler has been tested and calibrated in passive mode in preparation for safeguards accountability measurements of waste drums containing material removed from CVs for the CVD project.

36 MATERIALS SCIENCE↗

Science with Constellation-X, Choice of Instrumentation

The Constellation X-ray Observatory is one of the two Beyond Einstein Great Observatories and will provide a 100-fold increase in collecting area in high spectral resolving power X-ray instruments over the Chandra and XMM-Newton gratings instruments. The mission has four main science objectives which drive the requirements for the mission. This contribution to the Garmire celebration conference describes these four science areas: Black Holes, Dark Energy, Missing Baryons, and the Neutron Star Equation of State as well as the requirements flow-down that give rise to the choice of instrumentation and implementation for Constellation-X. As we show, each of these science areas place complementary constraints on mission performance parameters such as collecting area, spectral resolving power, timing resolution, and field of view. The mission's capabilities will enable a great breadth of science, and its resources will be open to the community through its General Observer program.

Hornscheimeier, Ann↗