Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo method.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Calculating effective diffusivities in the limit of vanishing molecular diffusion

In this paper we study the problem of the numerical calculation (by Monte Carlo methods) of the effective diffusivity for a particle moving in a periodic divergent-free velocity field, in the limit of vanishing molecular diffusion. In this limit traditional numerical methods typically fail, since they do not represent accurately the geometry of the underlying deterministic dynamics. We propose a stochastic splitting method that takes into account the volume-preserving property of the equations of motion in the absence of noise, and when inertial effects can be neglected. An extension of the method is then proposed for the cases where the noise has a non-trivial time-correlation structure and when inertial effects cannot be neglected. The method of modified equations is used to explain failings of Euler-based methods. The new stochastic geometric integrators are shown to outperform standard Euler-based integrators. Various asymptotic limits of physical interest are investigated by means of numerical experiments, using the new integrators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions

Certain brachytherapy dose distributions, such as those for LDR prostate implants, are readily modeled by treatment planning systems (TPS) that use the superposition principle of individual seed dose distributions to calculate the total dose distribution. However, dose distributions for brachytherapy treatments using high-Z shields or having significant material heterogeneities are not currently well modeled using conventional TPS. The purpose of this study is to establish a new treatment planning technique (Tufts technique) that could be applied in some clinical situations where the conventional approach is not acceptable and dose distributions present cylindrical symmetry. Dose distributions from complex brachytherapy source configurations determined with Monte Carlo methods were used as input data. These source distributions included the 2 and 3 cm diameter Valencia skin applicators from Nucletron, 4-8 cm diameter AccuBoost peripheral breast brachytherapy applicators from Advanced Radiation Therapy, and a 16 mm COMS-based eye plaque using {sup 103}Pd, {sup 125}I, and {sup 131}Cs seeds. Radial dose functions and 2D anisotropy functions were obtained by positioning the coordinate system origin along the dose distribution cylindrical axis of symmetry. Origin:tissue distance and active length were chosen to minimize TPS interpolation errors. Dosimetry parameters were entered into the PINNACLE TPS, and dose distributions were subsequently calculated and compared to the original Monte Carlo-derived dose distributions. The new planning technique was able to reproduce brachytherapy dose distributions for all three applicator types, producing dosimetric agreement typically within 2% when compared with Monte Carlo-derived dose distributions. Agreement between Monte Carlo-derived and planned dose distributions improved as the spatial resolution of the fitted dosimetry parameters improved. For agreement within 5% throughout the clinical volume, spatial resolution of dosimetry parameter data {<=}0.1 cm was required, and the virtual brachytherapy source data set included over 5000 data points. On the other hand, the lack of consideration for applicator heterogeneity effect caused conventional dose overestimates exceeding an order of magnitude in regions of clinical interest. This approach is rationalized by the improved dose estimates. In conclusion, a new technique was developed to incorporate complex Monte Carlo-based brachytherapy dose distributions into conventional TPS. These results are generalizable to other brachytherapy source types and other TPS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Semi-Analytical Benchmarks for MCNP6

Code verification is an extremely important process that involves proving or disproving the validity of code algorithms by comparing them against analytical results of the underlying physics or mathematical theory on which the code is based upon. Monte Carlo transport codes such as MCNP6 undergo verification and testing upon every release to ensure that the codes are properly simulating nature. Specifically, MCNP6 has multiple sets of problems with known analytic solutions that are used for code verification. Most of the verification problems are fairly simple due to the fact that they are usually composed of few materials, with simplified cross-sections, or physics approximations, and simple geometry. These approximations make the transport equation possible to solve analytically or semi-analytically, and thus they are quite valuable in verifying that the code algorithms and methods (Monte Carlo, discrete ordinates, etc.) are operating as intended. The remainder of this paper is organized as follows: first we briefly discuss the theory behind the benchmarks problems, then the numerical results are presented, and finally we conclude with general remarks on this and possible future work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Free Energy Considerations for Nucleic Acids with Dangling Ends Near a Surface: a Coarse Grained Approach

A coarse grained model for the thermodynamics of nucleic acid hybridization near surfaces has been extended and parameterized to consider the contribution of unpaired dangling ends. Theparameters of the model differ when representing a double stranded DNA section or a single stranded DNA section. The thermodynamic effects of the possibility of different dangling end combinations were considered in the presence of different types of surfaces. Configurational sampling was achieved by the Metropolis Monte Carlo method. To gain a more complete picture of the free energy changes, an estimation of the conformational entropy was included. We find a strong thermodynamic effect for dangling mismatches due to sequence requirements when they are nearer the surface as opposed to being held away from the surface.

59 BASIC BIOLOGICAL SCIENCES↗

Backscattered UV radiation - Effects of multiple scattering and the lower boundary of the atmosphere

A method is proposed for the calculation of a multiple-scattering correction to the single-scattering calculation of the radiance of the terrestrial atmosphere resulting from backscattered ultraviolet solar radiation in the spectral region used in the ozone profile inversion. This method uses jointly the usual analytical and Monte Carlo methods. Effects of the lower boundary of the atmosphere, cloud tops, and ground surface are investigated both qualitatively and quantitatively. The ratio of multiple to single scattering is determined, and its importance in ozone profile inversion of backscattered UV solar radiation from the terrestrial atmosphere is evaluated. The polarization of the atmospheric radiance is treated briefly.

Aruga, T.↗

Towards a Probabilistic Preliminary Design Criterion for Buckling Critical Composite Shells

A probability-based analysis method for predicting buckling loads of compression-loaded laminated-composite shells is presented, and its potential as a basis for a new shell-stability design criterion is demonstrated and discussed. In particular, a database containing information about specimen geometry, material properties, and measured initial geometric imperfections for a selected group of laminated-composite cylindrical shells is used to calculate new buckling-load "knockdown factors". These knockdown factors are shown to be substantially improved, and hence much less conservative than the corresponding deterministic knockdown factors that are presently used by industry. The probability integral associated with the analysis is evaluated by using two methods; that is, by using the exact Monte Carlo method and by using an approximate First-Order Second- Moment method. A comparison of the results from these two methods indicates that the First-Order Second-Moment method yields results that are conservative for the shells considered. Furthermore, the results show that the improved, reliability-based knockdown factor presented always yields a safe estimate of the buckling load for the shells examined.

Arbocz, Johann↗

Computing Radiative Transfer in a 3D Medium

A package of software computes the time-dependent propagation of a narrow laser beam in an arbitrary three- dimensional (3D) medium with absorption and scattering, using the transient-discrete-ordinates method and a direct integration method. Unlike prior software that utilizes a Monte Carlo method, this software enables simulation at very small signal-to-noise ratios. The ability to simulate propagation of a narrow laser beam in a 3D medium is an improvement over other discrete-ordinate software. Unlike other direct-integration software, this software is not limited to simulation of propagation of thermal radiation with broad angular spread in three dimensions or of a laser pulse with narrow angular spread in two dimensions. Uses for this software include (1) computing scattering of a pulsed laser beam on a material having given elastic scattering and absorption profiles, and (2) evaluating concepts for laser-based instruments for sensing oceanic turbulence and related measurements of oceanic mixed-layer depths. With suitable augmentation, this software could be used to compute radiative transfer in ultrasound imaging in biological tissues, radiative transfer in the upper Earth crust for oil exploration, and propagation of laser pulses in telecommunication applications.

Von Allmen, Paul↗

Monte Carlo Simulation of Heavy Nuclei Photofission at Intermediate Energies

A detailed description of photofission process at intermediate energies (200 to 1000 MeV) is presented. The study of the reaction is performed by a Monte Carlo method which allows the investigation of properties of residual nuclei and fissioning nuclei. The information obtained indicate that multifragmentation is negligible at the photon energies studied here, and that the symmetrical fission is dominant. Energy and mass distributions of residual and fissioning nuclei were calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation of a Cascade near a Plane Interface and in a Planar Layer

In order to detect cosmic rays and ultrahigh-energy neutrinos, a number of experiments based on the detection of radio radiation of cascades initiated by these particles in dense media such as ground ice massifs or lunar regolith have been developed. In most of the experiments, radio radiation is detected at the emission to the atmosphere or cosmic space rather than in a dense medium. Consequently, it is necessary to calculate the radiation of a cascade taking into account an interface between two media. This problem is usually solved numerically by the Monte Carlo method. A simple analytical expression for a radiation field in the wave zone of the less dense medium has been obtained for the case of development of the cascade in the dense medium and the crossing of the interface between two media by radiation. The effect of the third, additional medium on the radiation field of the cascade has also been considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methodology for Generating Covariance Data of Thermal Neutron Scattering Cross Sections

This paper details and implements a framework for evaluating thermal neutron scattering cross sections that provide S(α,β) data and covariance data for hydrogen in light water. This methodology involves perturbing model parameters of molecular dynamics potentials and fitting the simulation results to experimental data. The framework is general and can be applied to any material or simulation method. The fit is made using the Unified Monte Carlo method to experimentally measure double-differential scattering cross sections of light water at the Spallation Neutron Source at Oak Ridge National Laboratory. Mean values and covariance data were generated for model parameters, phonon density of states, double-differential cross sections, and total scattering cross sections. These posterior parameter values were very similar to their prior values with a maximum relative error of 0.54%. This falls within in the Unified Monte Carlo–calculated uncertainties on the order of 2.7%. Additionally, posterior double-differential cross sections agree favorably with ENDF/B-VIII.0 cross sections. The new thermal scattering law was tested by comparing it against benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook, which showed a slight improvement over the ENDF/B-VIII.0 library. Additionally, the covariance matrix of the phonon density of states was validated to confirm that the spread of k eff from the density of states used to generate the covariance matrix was similar to the spread of k eff from the density of states of the sampled covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by {approx_equal}1 MJ plasma focus

The spectra of neutrons outside the plasma focus device PF-1000 with an upper energy limit of {approx_equal}1 MJ was measured using a Bonner spheres spectrometer in which the active detector of thermal neutrons was replaced by nine thermoluminescent chips. As an a priori spectrum for the unfolding procedure, the spectrum calculated by means of the Monte Carlo method with a simplified model of the discharge chamber was selected. Differences between unfolded and calculated spectra are discussed with respect to properties of the discharge vessel and the laboratory layout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data acquisition and analysis of the UNCOSS underwater explosive neutron sensor

The purpose of the FP7 UNCOSS project (Underwater Coastal Sea Surveyor, http://www.uncoss-project.org) is to develop a neutron-based underwater explosive sensor to detect unexploded ordnance lying on the sea bottom. The Associated Particle Technique is used to focus the inspection on a suspicious object located by optical and electromagnetic sensors and to determine if there is an explosive charge inside. This paper presents the data acquisition electronics and data analysis software which have been developed for this project. The electronics digitize and process the signal in real-time based on a field programmable gate array structure to perform precise time-of-flight and gamma-ray energy measurements. UNCOSS software offers the basic tools to analyze the time-of-flight and energy spectra of the interrogated object. It allows to unfold the gamma-ray spectrum into pure elemental count proportions, mainly C, N, O, Fe, Al, Si, and Ca. The C, N, and O count fractions are converted into chemical proportions by taking into account the gamma-ray production cross sections, as well as neutron and photon attenuation in the different shields between the ROV (Remotely Operated Vehicle) and the explosive, such as the explosive iron shell, seawater, and ROV envelop. These chemical ratios are plotted in a two-dimensional (2D) barycentric representation to position the measured point with respect to common explosives. The systematic uncertainty due to the above attenuation effects and counting statistical fluctuations are combined with a Monte Carlo method to provide a 3D uncertainty area in a barycentric plot, which allows to determine the most probable detected materials in view to make a decision about the presence of explosive. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty analysis on reactivity and discharged inventory for a pressurized water reactor fuel assembly due to {sup 235,238}U nuclear data uncertainties

This paper discusses the uncertainty analysis on reactivity and inventory for a typical PWR fuel element as a result of uncertainties in {sup 235,238}U nuclear data. A typical Westinghouse 3-loop fuel assembly fuelled with UO{sub 2} fuel with 4.8% enrichment has been selected. The Total Monte-Carlo method has been applied using the deterministic transport code DRAGON. This code allows the generation of the few-groups nuclear data libraries by directly using data contained in the nuclear data evaluation files. The nuclear data used in this study is from the JEFF3.1 evaluation, and the nuclear data files for {sup 238}U and {sup 235}U (randomized for the generation of the various DRAGON libraries) are taken from the nuclear data library TENDL. The total uncertainty (obtained by randomizing all {sup 238}U and {sup 235}U nuclear data in the ENDF files) on the reactor parameters has been split into different components (different nuclear reaction channels). Results show that the TMC method in combination with a deterministic transport code constitutes a powerful tool for performing uncertainty and sensitivity analysis of reactor physics parameters. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Critical Temperature Curve in BEC-BCS Crossover

The strongly correlated regime of the crossover from Bardeen-Cooper-Schrieffer pairing to Bose-Einstein condensation can be realized by diluting a system of two-component fermions with a short-range attractive interaction. We investigate this system via a novel continuous-space-time diagrammatic determinant Monte Carlo method and determine the universal curve T{sub c}/{epsilon}{sub F} for the transition temperature between the normal and the superfluid states as a function of the scattering length with the maximum on the Bose-Einstein condensation side. At unitarity, we confirm that T{sub c}/{epsilon}{sub F}=0.152(7)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulations and radiation dosimetry measurements of peripherally applied HDR {sup 192}Ir breast brachytherapy D-shaped applicators

Conformal dose coverage for accelerated partial breast irradiation or radiotherapy boost can be obtained with AccuBoost registered D-shaped brachytherapy applicators using a flattened surface positioned near the patient. Three D-shaped applicators (D45/D53/D60) were dosimetrically characterized using Monte Carlo methods (MCNP5), air ionization chambers (Farmer and Markus), and radiochromic film (GafChromic EBT) in polystyrene and ICRU 44 breast tissue. HDR {sup 192}Ir source dwell times were either constant or optimized to improve skin dose uniformity. Scatter dose decreased as depth decreased. 10 mm beyond the applicator aperture, dose reductions of 90% and 51% were observed at depths of 0 and 30 mm, respectively. Similarly, planar dose uniformity improved as depth decreased and was also due to scatter and applicator geometry. Dose uniformity inside the applicator aperture was approximately 11% and 15% for all three applicators at the skin and 30 mm deep, respectively. Depth dose measurements in polystyrene using ion chamber and radiochromic film agreed with Monte Carlo results within 2%. Discrepancies between film and Monte Carlo dose profiles at 30 mm depth were within 1%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry

Purpose: Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: A film stack dosimeter was developed using Gafchromic{sup ®} EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. Results: The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the beam axis is parallel to the film planes. Measured and simulated PDD profiles agree within a root-mean-square difference of 1.3%. In-field film stack dosimeter and TLD measurements agree within 5%, and measurements in the field penumbra agree within 0.5 mm. Film stack dosimeter and TLD measurements have expanded (k = 2) overall measurement uncertainties of 6.2% and 5.8%, respectively. Film stack dosimeter measurements of an IMRT dose distribution have 98% agreement with the treatment planning system dose calculation, using gamma criteria of 3% and 2 mm. Conclusions: The film stack dosimeter is capable of high-resolution, low-uncertainty 3D dose measurements, and can be readily incorporated into an existing film dosimetry program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Covariant transport theory approach to elliptic flow in relativistic heavy ion collision

We present a new direct simulation Monte Carlo method for solving the relativistic Boltzmann equation. We solve numerically the two-dimensional Boltzmann equation using this new algorithm. We find that elliptic flow from this transport calculation smoothly converges toward the value from ideal hydrodynamics as the number of collisions per particle increases, as expected on general theoretical grounds but in contrast with previous transport calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phase transitions and critical properties of the frustrated Heisenberg model on a layer triangular lattice with next-to-nearest-neighbor interactions

The critical behavior of the three-dimensional antiferromagnetic Heisenberg model with nearest-neighbor (J) and next-to-nearest-neighbor (J{sub 1}) interactions is studied by the replica Monte Carlo method. The first-order phase transition and pseudouniversal critical behavior of this model are established for a small lattice in the interval R = vertical bar J{sub 1}/J vertical bar = 0-0.115. A complete set of the main static magnetic and chiral critical indices is calculated in this interval using the finite-dimensional scaling theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗