Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

High-Resolution Full-Field Structural Microscopy of the Voltage-Induced Filament Formation in VO 2 -Based Neuromorphic Devices

In order to make neuromorphic functions in memristive devices more efficient, information about the structural properties of filament formation at the micro- and mesoscopic scales is necessary. Despite extensive research on VO 2 , a key material due to its filament formation, local operando structural measurements remain challenging and often involve destructive specimen preparation and long rastering times, greatly limiting the scope of experimental studies. Utilizing dark-field X-ray microscopy (DFXM), a fullfield imaging modality, structural signatures of the filament formation process operando are revealed in VO 2 devices. DFXM experiments illustrate that rutile filaments contain isolated monoclinic clusters, indicating structural nonuniformity interior to the filament. The formation of the rutile phase beneath device electrodes was shown to precede filament development, followed by the formation of filament paths guided by nucleation sites within the device. Finally, a medium-term (<30 min) memory mechanism is observed in VO 2 , mediated by sites within the device gap that tend to switch at significantly lower voltages after electrical cycling, a tendency that persists through a brief thermal reset. High spatial resolution, large field-of-view, structure selectivity, and fast signal acquisition of DFXM provided insight into structural features of the filamentary channel and surrounding regions during voltage cycling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Amorphous to fcc-polycrystal transition in Ge{sub 2}Sb{sub 2}Te{sub 5} thin films studied by electrical measurements: Data analysis and comparison with direct microscopy observations

We experimentally investigate the isothermal amorphous-to-fcc polycrystalline phase transition process in amorphous Ge{sub 2}Sb{sub 2}Te{sub 5} thin films prepared by sputtering. The amorphous layers were either as deposited or formed by Ar{sup +} ion implantation after crystallization at 300 deg. C. The kinetics of the amorphous-to-polycrystal transition are analyzed through electrical measurements, in which the Johnson-Mehl-Avrami-Kolmogorov theory is employed. The procedure to extract the kinetics of the phase transition from conductivity versus time data is carefully discussed and compared to data of cross-sectional transmission electron microscopy images versus anneal time. By following this proposed procedure, the nucleation and growth parameters, and the activation energies have been determined. Results indicate that the process of isothermal crystallization in Ge{sub 2}Sb{sub 2}Te{sub 5} takes place in two stages, in which the Avrami exponent changes in the range from 3 to 1. These results are understood in terms of modifications in the kinetics of the phase transition.

36 MATERIALS SCIENCE↗

Dehydriding process of alpha-AlH{sub 3} observed by transmission electron microscopy and electron energy-loss spectroscopy

The dehydriding reaction of alpha-AlH{sub 3} induced by high-energy electron irradiation was observed in situ by transmission electron microscopy and associated electron energy-loss spectroscopy (EELS). An alpha-AlH{sub 3} crystal decomposed into fine aluminum particles while retaining its initial external shape because of a thin rigid surface layer that covered the entire particle. EELS revealed that the thin surface layer was amorphous aluminum oxide, which stabilizes alpha-AlH{sub 3} particles at ambient temperature.

36 MATERIALS SCIENCE↗

Noise characteristics of the gas ionization cascade used in low vacuum scanning electron microscopy

The noise characteristics of gas cascade amplified electron signals in low vacuum scanning electron microscopy (LVSEM) are described and analyzed. We derive expressions for each component contributing to the total noise culminating in a predictive, quantitative model that can be used for optimization of LVSEM operating parameters. Signal and noise behavior is characterized experimentally and used to validate the model. Under most operating conditions, the noise is dominated by the excess noise generated in the gas amplification cascade. At high gains, the excess noise increases proportionally with gain such that the signal-to-noise ratio is constant. The effects of several instrument operating parameters, including working distance, gas pressure, beam current, and detector bias, are condensed and presented in the form of a master curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Plasmon Modes in Metallic Nanostructures with Correlated Optical and Electron Microscopy

The study of plasmons is at the core of Surface-Enhanced Raman Spectroscopy (SERS). Surface plasmons are generated from the interaction of light with the electrons on the surface of a metal and are responsible for the electromagnetic enhancement mechanism in SERS. It is believed that the different modes that are observed in plasmon resonances depend on the shape of the nanoparticles [1].The goal of this project is to correlate the optical measurements of nanostructures generated by the surface plasmons using Resonant Rayleigh Scattering, with high resolution structural information obtained by using Scanning Transmission Electron Microscopy (STEM). This technique will also reveal the different localized surface plasmon modes in the nanostructure as well as the relationship between the optical surface plasmons and the plasmons generated from the inelastic scattering of the electron beam. The measurement of the surface plasmon excitations in a STEM is called Electron Energy Loss Spectroscopy (EELS).The success of this project will provide new tools to study plasmons important in Single Molecule Surface-Enhanced Raman Spectroscopy (SMSERS), bio/chemical sensing [2-4], and other forms of surface-enhanced spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rutherford backscattering oscillation in scanning helium-ion microscopy

Scanning helium-ion microscopy (SHIM) yields high-resolution imaging and is capable of surface elemental analysis at the nanometer scale. Here we examine recently discovered SHIM backscattered intensity oscillations versus the target atomic number. These oscillations are contrary to the expected monotonic increase of the backscattered helium-ion (He{sup +}) rate with the atomic number of elemental samples. We explore the ion-sample interaction via numerical simulations for a variety of scattering geometries and confirm the presence of oscillations. The oscillations are attributed to the atomic rather than the nuclear structure of the target. To that end, we study the link (near anticorrelation) between backscatter rate and He{sup +} beam stopping power, both versus the target atomic number. This leads us to ascribe the origin of the backscatter oscillation to the ''Z{sub 2}-oscillations'' of the stopping power in ion-beam physics, with the latter being rooted in the valence electron configuration of elemental targets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron beam heating effects during environmental scanning electron microscopy imaging of water condensation on superhydrophobic surfaces

Superhydrophobic surfaces (SHSs) show promise as promoters of dropwise condensation. Droplets with diameters below {approx}10 {mu}m account for the majority of the heat transferred during dropwise condensation but their growth dynamics on SHS have not been systematically studied. Due to the complex topography of the surface environmental scanning electron microscopy is the preferred method for observing the growth dynamics of droplets in this size regime. By studying electron beam heating effects on condensed water droplets we establish a magnification limit below which the heating effects are negligible and use this insight to study the mechanism of individual drop growth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ transmission electron microscopy analysis of conductive filament during solid electrolyte resistance switching

An in situ transmission electron microscopy (TEM) analysis of a solid electrolyte, Cu-GeS, during resistance switching is reported. Real-time observations of the filament formation and disappearance process were performed in the TEM instrument and the conductive-filament-formation model was confirmed experimentally. Narrow conductive filaments were formed corresponding to resistance switching from high- to low-resistance states. When the resistance changed to high-resistance state, the filament disappeared. It was also confirmed by use of selected area diffractometry and energy-dispersive x-ray spectroscopy that the conductive filament was made of nanocrystals composed mainly of Cu.

36 MATERIALS SCIENCE↗

The Measurement of MTFs in X-ray Microscopy Using Diffractograms

A novel method to characterize the optical performance of a high-resolution transmission x-ray microscope is presented. It makes use of test patterns that consist of random arrays of sub-resolution holes in a thin metal film, and so approximate to white-noise input signals for the microscope. The test patterns have been fabricated by electron-beam lithography at length scales appropriate for the resolution available in x-ray microscopy, so that diffractograms produced from the image data can be directly interpreted in terms of the contrast transfer function of the optical system. Results of this method are shown for both brightfield and differential phase contrast imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Enhanced information content for three-dimensional localization and tracking using the double-helix point spread function with variable-angle illumination epifluorescence microscopy

The signal-to-noise ratio (SNR) and three-dimensional localization precision of a double helix point spread function (DH-PSF) can be significantly improved by applying variable-angle illumination epifluorescence microscopy (VAI, also commonly known as “pseudo-TIRF” or “quasi-TIRF”). In this paper, we performed a quantitative analysis of the dependence of SNR and localization precision on the number of measured photons and the incident angle for static particles under both low (at a planar index-matched interface) and high (within a porous silica matrix) fluorescent background conditions. We found that under noisier imaging conditions, the SNR and localization precision obtained using VAI are up to fivefold and threefold greater, respectively, than those obtained using epi-illumination. Finally and moreover, we demonstrate that the combination of DH-PSF and VAI can significantly improve the accuracy of the measured diffusion coefficient for mobile particles, even at a relatively large distance (50 μm) from the boundary of the optical cell.

42 ENGINEERING↗

Imaging via complete cantilever dynamic detection: General dynamic mode imaging and spectroscopy in scanning probe microscopy

We develop and implement a multifrequency spectroscopy and spectroscopic imaging mode, referred to as general dynamic mode (GDM), that captures the complete spatially- and stimulus dependent information on nonlinear cantilever dynamics in scanning probe microscopy (SPM). GDM acquires the cantilever response including harmonics and mode mixing products across the entire broadband cantilever spectrum as a function of excitation frequency. GDM spectra substitute the classical measurements in SPM, e.g. amplitude and phase in lock-in detection. Here, GDM is used to investigate the response of a purely capacitively driven cantilever. We use information theory techniques to mine the data and verify the findings with governing equations and classical lock-in based approaches. We explore the dependence of the cantilever dynamics on the tip–sample distance, AC and DC driving bias. This approach can be applied to investigate the dynamic behavior of other systems within and beyond dynamic SPM. In conclusion, GDM is expected to be useful for separating the contribution of different physical phenomena in the cantilever response and understanding the role of cantilever dynamics in dynamic AFM techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Cross-Sectional Scanning Electron Microscopy of Perovskite Solar Cells

Organic–inorganic perovskites are an emerging class of photovoltaic materials. Despite achieving power conversion efficiencies surpassing 26%, the challenge of perovskite stability including degradation during exposure to operational conditions such as light, heat, humidity, water, oxygen, and electric fields is well known. Related, perovskite instability has limited high-resolution electron imaging and characterization techniques that can be used for understanding degradation mechanisms. Furthermore, we demonstrate perovskite device cross-section preparation using mechanical polishing in a water-free environment with cryogenic Ar ion milling. Scanning electron microscopy was then used in both backscattered electron and secondary electron imaging modes to obtain information about layer structure, grain aggregate structure, and compositional heterogeneity. Monte Carlo CASINO simulations inform optimum beam conditions and image acquisition parameters and the effects of accelerating voltage, dwell times, and frame averaging for practical image acquisition are reported.

14 SOLAR ENERGY↗

Nanometric resolution using far-field optical tomographic microscopy in the multiple scattering regime

The resolution of optical far-field microscopes is classically diffraction-limited to half the illumination wavelength. We show experimentally that this fundamental limit does not apply in the multiple scattering regime. We used tomographic diffractive microscopy at 633 nm to image two pairs of closely spaced rods (with a width and interdistance of 50 nm) of widely different diffractive properties. Using an inversion algorithm accounting for multiple scattering, only the pair of highly diffracting rods could be clearly visualized with a resolution similar to that of an atomic force microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural characterization of interfaces in epitaxial Fe/MgO/Fe magnetic tunnel junctions by transmission electron microscopy

We present a detailed structural characterization of the interfaces in Fe/MgO/Fe layers grown by molecular-beam epitaxy using aberration-corrected transmission electron microscopy (TEM), scanning TEM, and electron energy-loss spectroscopy. When fabricated into magnetic tunnel junctions, these epitaxial devices exhibit large tunnel magnetoresistance ratios (e.g., 318% at 10 K), though still considerably lower than the values predicted theoretically. The reason for this discrepancy is being debated and has been attributed to the structure of, and defects at the interface, namely, the relative position of the atoms, interface oxidation, strain, and structural asymmetry of the interfaces. In this structural study, we observed that Fe is bound to O at the interfaces. The interfaces are semicoherent and mostly sharp with a minor degree of oxidation. A comparison of the two interfaces shows that the top MgO/Fe interface is rougher.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct measurement of electron channeling in a crystal using scanning transmission electron microscopy

Self-focusing of an atomic-scale high-energy electron wave packet by channeling along a zone axis in crystalline silicon is directly measured by scanning transmission electron microscopy using thin epitaxial SrTiO{sub 3}(100) islands grown on Si(100) as test objects. As the electron probe propagates down a silicon atom column, it is progressively focused onto the column, resulting in a fourfold increase in the scattered signal at the channeling maximum. This results in an enhancement of the visibility of the SrTiO{sub 3} islands, which is lost if the sample is flipped upside down and the channeling occurs only after the probe scatters off the SrTiO{sub 3} layer. The evolution of the probe wave function calculated by the multislice method accurately predicts the trends in the channeling signal on an absolute thickness scale. We find that while electron channeling enhances the visibility of on-column atoms, it suppresses the contribution from off-column atoms. It can therefore be used as a filter to selectively image the atoms that are most aligned with the atomic columns of the substrate. By using this technique, coherent islands can be distinguished from relaxed islands. For SrTiO{sub 3} films formed in a topotactic reaction on Si(100), we show that only {approx}55% of the SrTiO{sub 3} is aligned with the Si atom columns. The fraction of coherent SrTiO{sub 3} islands on Si(100) can be increased by choosing growth conditions away from equilibrium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Systematic features of defocused images in scanning electron microscopy and nanoscale size measurements

The problems of nanoscale size measurements were considered. The results of full-scale and model experiments with images of backscattered electron-scanning electron microscopy show that all intensity profiles appearing during defocusings intersect at points corresponding to object edges. A physical explanation to the observed effect was proposed. The model validity was confirmed for a rectangular bump. Presumably, the effect makes it possible to avoid the electron micrograph's simulation when comparing images of a measured object with a measure image.

36 MATERIALS SCIENCE↗

Seeing Inside Materials by Aberration-Corrected Electron Microscopy

The recent successful correction of lens aberrations in the electron microscope has improved resolution by more than a factor of two in just a few years, bringing many benefits for the study of materials. These benefits extend significantly beyond enhanced resolution alone. Aberration correction gives higher resolution by allowing the objective lens to have a wider aperture, which also results in a reduced depth of field. This effect can be used to only focus specific sections inside materials for the first time. In this contribution we describe recent results exploiting this capability. Additionally, we show how combining the microscopy data with first-principles theory gives new insights into materials properties. We cover two applications, both involving heavy atoms in a lighter host. The first shows how single Hf atoms can be mapped in three dimensions inside the 1 nm-wide SiO2 region of a high dielectric constant device structure, and how a link to macroscopic device properties results through theoretical calculations. The second example is from the field of nanoscience, where individual Au atoms are imaged inside Si nanowires grown by a vapor-liquid-solid mechanism. The majority of Au atoms are probably injected by the highly energetic electron beam. However, their observed sites and atomic configurations represent at least meta-stable configurations and match well to results from density functional calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Contribution of advanced fluorescence nano microscopy towards revealing mitotic chromosome structure

The organization of chromatin into higherorder structures and its condensation process represent one of the key challenges in structural biology. This is important for elucidating several disease states. To address this long-standing problem, development of advanced imaging methods has played an essential role in providing understanding into mitotic chromosome structure and compaction. Amongst these are two fast evolving fluorescence imaging technologies, specifically fluorescence lifetime imaging (FLIM) and superresolution microscopy (SRM). FLIM in particular has been lacking in the application of chromosome research while SRM has been successfully applied although not widely. Furthermore, both these techniques are capable of providing fluorescence imaging with nanometer information. SRM or "nanoscopy" is capable of generating images of DNA with less than 50 nm resolution while FLIM when coupled with energy transfer may provide less than 20 nm information. Here, we discuss the advantages and limitations of both methods followed by their contribution to mitotic chromosome studies. Furthermore, we highlight the future prospects of how advancements in new technologies can contribute in the field of chromosome science.

59 BASIC BIOLOGICAL SCIENCES↗