Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Maximization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Magnetic Resonance Imaging Assessment of Spinal Cord and Cauda Equina Motion in Supine Patients With Spinal Metastases Planned for Spine Stereotactic Body Radiation Therapy

Purpose: To assess motion of the spinal cord and cauda equina, which are critical neural tissues (CNT), which is important when evaluating the planning organ-at-risk margin required for stereotactic body radiation therapy. Methods and Materials: We analyzed CNT motion in 65 patients with spinal metastases (11 cervical, 39 thoracic, and 24 lumbar spinal segments) in the supine position using dynamic axial and sagittal magnetic resonance imaging (dMRI, 3T Verio, Siemens) over a 137-second interval. Motion was segregated according to physiologic cardiorespiratory oscillatory motion (characterized by the average root mean square deviation) and random bulk shifts associated with gross patient motion (characterized by the range). Displacement was evaluated in the anteroposterior (AP), lateral (LR), and superior-inferior (SI) directions by use of a correlation coefficient template matching algorithm, with quantification of random motion measure error over 3 separate trials. Statistical significance was defined according to P<.05. Results: In the AP, LR, and SI directions, significant oscillatory motion was observed in 39.2%, 35.1%, and 10.8% of spinal segments, respectively, and significant bulk motions in all cases. The median oscillatory CNT motions in the AP, LR, and SI directions were 0.16 mm, 0.17 mm, and 0.44 mm, respectively, and the maximal statistically significant oscillatory motions were 0.39 mm, 0.41 mm, and 0.77 mm, respectively. The median bulk displacements in the AP, LR, and SI directions were 0.51 mm, 0.59 mm, and 0.66 mm, and the maximal statistically significant displacements were 2.21 mm, 2.87 mm, and 3.90 mm, respectively. In the AP, LR, and SI directions, bulk displacements were greater than 1.5 mm in 5.4%, 9.0%, and 14.9% of spinal segments, respectively. No significant differences in axial motion were observed according to cord level or cauda equina. Conclusions: Oscillatory CNT motion was observed to be relatively minor. Our results support the importance of controlling bulk patient motion and the practice of applying a planning organ-at-risk margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Toxicity Grade 3 and 4 After Irradiation in Children and Adolescents: Results From the IPPARCA Collaboration

Purpose: In the context of oncologic therapy for children, radiation therapy is frequently indicated. This study identified the frequency of and reasons for the development of high-grade acute toxicity and possible sequelae. Materials and Methods: Irradiated children have been prospectively documented since 2001 in the Registry for the Evaluation of Side Effects After Radiation in Childhood and Adolescence (RiSK) database in Germany and since 2008 in the registry for radiation therapy toxicity (RADTOX) in Sweden. Data were collected using standardized, published forms. Toxicity classification was based on Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. Results: As of June 2013, 1500 children have been recruited into the RiSK database and 485 into the RADTOX registry leading to an analysis population of 1359 patients (age range 0-18). A total of 18.9% (n=257) of all investigated patients developed high-grade acute toxicity (grades 3/4). High-grade toxicity of the bone marrow was documented for 63.8% (n=201) of those patients, oral mucositis for 7.6% (n=24), and dermatitis for 7.6% (n=24). Patients with high-grade acute toxicity received concomitant chemotherapy more frequently (56%) than patients with no or lower acute toxicity (31.5%). In multivariate analyses, concomitant chemotherapy, diagnosis of Ewing sarcoma, and total radiation dose showed a statistically noticeable effect (P≤.05) on acute toxicity, whereas age, concomitant chemotherapy, Hodgkin lymphoma, Ewing sarcoma, total radiation dose, and acute toxicity influenced the time until maximal late toxicity. Conclusions: Generally, high-grade acute toxicity after irradiation in children and adolescence occurs in a moderate proportion of patients (18.9%). As anticipated, the probability of acute toxicity appeared to depend on the prescribed dose as well as concomitant chemotherapy. The occurrence of chronic toxicity correlates with the prior acute toxicity grade. Age seems to influence the time until maximal late toxicity but not the development of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Henri Mondor Procedure of Morbidity and Mortality Review Meetings: Prospective Registration of Clinical, Dosimetric, and Individual Radiosensitivity Data of Patients With Severe Radiation Toxicity

Purpose: After radiation therapy (RT), various radiation-induced toxicities can develop in about one-fourth of patients. An international interest in using morbidity and mortality rates to monitor the quality of care and integrate morbidity and mortality review (MMR) meetings into organizations' governance processes has arisen. We report the first results of patients included in our MMR procedure that included biological assays for individual intrinsic radiosensitivity (IIRS). Methods and Materials: Twenty-three patients were prospectively included in the MMR database. Twenty-two were evaluable for IIRS. Prostate (n=10) and breast (n=8) cancers were the most frequent disease types. The total dose delivered, determined according to the type of disease, ranged from 30 to 74 Gy. Our MMR procedure requires strict criteria: patients with unresolved toxicity of grade 3 or higher with availability of clinical (photographic) data, IIRS results obtained from skin biopsy assays, treatment modalities, and follow-up data. The RT technique and dosimetry were reviewed. Results: Our prospective registration of toxicities showed mainly rectitis, occurring in 7 cases, and skin toxicities, occurring in 9. Of the 7 patients with rectitis, 5 received 66 Gy of post-prostatectomy RT with V50 (rectum volume receiving 50 Gy) ranging from 45% to 75% and a mean maximal dose of 66.5 Gy. For dermatitis and cystitis, the mean maximal doses were in the range of classical constraints without any overdosage or dose heterogeneity. No errors were found in the review of treatment planning and positioning. Conversely, all the patients were considered biologically as radiosensitive with genomic instability and ATM (ataxia telangiectasia mutated)-dependent DNA double-strand break repair impairments. Conclusions: The MMR review of files allowed clear answers for patients on the relationship between clinical events and their IIRS. Our procedure has allowed education of all our staff to monitor, identify, and document clinical, physical, and biological aspects of radiation-induced toxicities. Thus we recommend the introduction of the MMR procedure in RT departments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal experimental design for prediction based on push-forward probability measures

Incorporating experimental data is essential for increasing the credibility of simulation-aided decision making and design. This paper presents a method which uses a computational model to guide the optimal acquisition of experimental data to produce data-informed predictions of quantities of interest (QoI). Many strategies for optimal experimental design (OED) select data that maximize some utility that measures the reduction in uncertainty of uncertain model parameters, for example the expected information gain between prior and posterior distributions of these parameters. In this paper, we seek to maximize the expected information gained from the pushforward of an initial (prior) density to the push-forward of the updated (posterior) density through the parameter-to-prediction map. The formulation presented is based upon the solution of a specific class of stochastic inverse problems which seeks a probability density that is consistent with the model and the data in the sense that the push-forward of this density through the parameter-to-observable map matches a target density on the observable data. While this stochastic inverse problem forms the mathematical basis for our approach, we develop a one-step algorithm, focused on push-forward probability measures, that leverages inference-for-prediction to bypass constructing the solution to the stochastic inverse problem. A number of numerical results are presented to demonstrate the utility of this optimal experimental design for prediction and facilitate comparison of our approach with traditional OED.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the economic implications of varied pressure drawdown strategies generated using a real-time, rapid predictive, multi-fidelity model for unconventional oil and gas wells

Experience has suggested that pressure maintenance in hydraulically fractured reservoirs via lower, more sustained production drawdowns may offer improved cumulative recovery and overall resource extraction efficiency compared to more rapid drawdown approaches aimed at generating high initial production. However, given the inherent variability of oil and natural gas markets, operators pursue production strategies that maximize profitability over resource extraction efficiency. This study focuses on evaluating the implications of contrasting pressure drawdown strategies on the long-term production and resulting economics for a real, producing unconventional gas well in the Marcellus Shale of the Appalachian Basin using a techno-economic analysis approach. Our research combines elements of well-specific horizontal well design, production forecasting, equipment sizing and capital cost estimation, operating cost estimation, and revenue and tax calculations. Gas production forecast outlook scenarios were generated under varying pressure drawdowns using two approaches: 1) a novel physics-informed machine learning workflow and 2) traditional reservoir simulation. A discounted cash flow model was used to evaluate the resulting economic implications for each drawdown scenario—generating output for exploring the coupled effect of factors like the timing and volume of gas production, prevailing economic and market conditions for natural gas, and overall estimated ultimate recovery on profitability metrics such as internal rate of return and net present value. Results show that there is potential to maximize the cumulative gas produced in the specific case study well by employing a lower pressure drawdown. Conversely, the greatest profitability is achieved using rapid drawdown as signified by a small, specific subset of our outlook scenarios. On an averaging basis, we find that the combinations of highest cumulative producing and most profitable scenarios occur under lower drawdowns with long (>40 years) producing timeframes, but require higher relative gas price and lower discounting considerations. Further, the machine learning predictive outlooking capability proved effective for enabling rapid generation of a multitude of scenario forecasts. As a result, a variety of prominent example cases could be generated to strike the balance of greater productivity and economic return given their associated producing features and economic conditions when compared to similar producing scenarios—critical insight that offers improved decision support for unconventional oil and gas operations.

42 ENGINEERING↗

Converting polycarbonate and polystyrene plastic wastes intoaromatic hydrocarbons via catalytic fast co-pyrolysis

Thermochemical conversion of plastic wastes is a promising approach to produce alternative energy-based fuels. Herein, we conducted catalytic fast co-pyrolysis of polycarbonate (PC) and polystyrene (PS) to generate aromatic hydrocarbons using HZSM-5 (Zeolite Socony Mobil-5, hydrogen, Aluminosilicate) as a catalyst. The results indicated that employing HZSM-5 in the catalytic conversion of PC facilitated the synthesis of aromatic hydrocarbons in comparison to the non-catalytic run. A competitive reaction between aromatic hydrocarbons and aromatic oxygenates was observed within the studied temperature region, and catalytic degradation temperature of 700 °C maximized the competing reaction towards the formation of targeted aromatic hydrocarbons at the expense of phenolic products. Catalyst type also played a vital role in the catalytic decomposition of PC wastes, and HZSM-5 with different Si/Al molar ratios produced more aromatic hydrocarbons than HY (Zeolite Y, hydrogen, Faujasite). Regarding the effect of Si/Al molar ration in HZSM-5 on the distribution of monocyclic aromatic hydrocarbons (MAHs), a Si/Al molar ratio of 38 maximized benzene formation with an advanced factor of 5.1. Catalytic fast co-pyrolysis of PC with hydrogen-rich plastic wastes including polypropylene (PP), polyethylene (PE), and polystyrene (PS) favored the production of MAHs, and PS was the most effective hydrogen donor with a ~2.5-fold increase. The additive effect of MAHs increased at first and then decreased when the PC percentage was elevated from 30 % to 90 %, achieving the maximum value of 32.4 % at 70 % PC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing t1 noise through rapid scanning

The so-called t 1 noise, which arises due to random instabilities in the spectrometer hardware, remains the primary source of noise that limits the sensitivity of most 2D NMR experiments, particularly in the expanding group of solid-state NMR methods that utilize dipolar-recoupling. Here in this communication we revisit the relationship between the signal intensity and the t 1 noise produced. It is shown that since the latter scales linearly with the signal strength, the use of a conventional relaxation delay of 1.3T 1 may prove far from optimal. In cases where the fluctuations occur on a shorter timescale than the recycle delay, a considerably faster repetition rate should be used to maximize the time sensitivity in a 2D experiment than what is used to maximize the sensitivity in 1D. This is demonstrated with the acquisition of 1 H{ 13 C} Dipolar-mediated Heteronuclear Multiple-Quantum Correlation (D-HMQC) type spectra in which the sensitivity could be nearly doubled by choosing a very short relaxation delay corresponding to 0.2T 1 .

2D NMR↗

The effect of helium on cavity swelling in dual-ion irradiated Fe and Fe-10Cr ferritic alloys

We report Ferritic-martensitic (FM) steels for in-vessel components in proposed fusion reactors are expected to suffer from high levels of displacement damage and helium (He) generation by neutron transmutation. However, a thorough understanding of the He synergistic effects on the cavity swelling in FM steels is still not well established. To gain fundamental insights into the He effect on cavity swelling, high purity Fe and Fe-10 wt.% Cr ferritic model alloys were irradiated with 8 MeV Ni ions and co-implanted He ions at 400 to 550 °C up to 30 displacements per atom (dpa) with He implantation rates of 0.1, 10 and 50 appm He/dpa. The current study focuses on the 50 appm He/dpa, 500 °C behavior vs. 0.1 and 10 appm He/dpa. Irradiation-induced defects, including cavities, dislocation loops, and dislocation networks were characterized using transmission electron microscopy (TEM). In the grain interior, a bimodal cavity size distribution was observed in the 10 and 50 appm He/dpa samples, but not for 0.1 appm He/dpa. Cavity swelling was maximized at intermediate He implantation rates of ~10 appm He/dpa for both ion-irradiated Fe and Fe-10Cr alloys. The cavity swelling behavior as a function of He implantation rate appears to be controlled by the He/dpa-dependent variation of cavity sink strengths. Treating small bubbles as biased sinks for interstitial absorption can significantly increase the ratio of biased to unbiased sink strengths (Q) and results in maximized cavity swelling for a Q ratio close to one.

36 MATERIALS SCIENCE↗

Structural and physical properties evolution in the 6H BaRu{sub 1-x}Mn{sub x}O{sub 3} synthesized under high pressure

The 6H BaRu{sub 1-x}Mn{sub x}O{sub 3} with the hexagonal BaTiO{sub 3} structure was synthesized using high-pressure sintering method. It is found that the lattice parameter deviates from Vegard's law at x=0.3 for the solid solutions due to the charge transfer effects at B-site. The substitution of Mn for Ru cations gives rise to the short-range magnetic ordering, due to the disordered arrangement of Ru and Mn cations. The compounds are weak ferromagnetic in the x range 0.05-0.40, with the maximal Curie temperature T{sub c} 175.2 K at x=0.10. They are of spin-glass-like magnetism at lower temperature at x{>=}0.1. With Mn doping, the 6H BaRuO{sub 3} transforms to a semiconductor from the primal metal at x=0.30. The resistance as a function of temperature below about 70 K follows the two-dimensional variable-range hopping conduction mechanism in BaRu{sub 0.50}Mn{sub 0.50}O{sub 3}. - Graphical abstract: The 6H BaRu{sub 1-x}Mn{sub x}O{sub 3} was synthesized using high-pressure sintering. The substitution of Mn for Ru cations gives rise to the short-range magnetic ordering, with the maximal Curie temperature T{sub c} 175.2 K at x=0.10. The compounds are of spin-class magnetism at lower temperature at x{>=}0.05. Mn doping results in the transition from the primal metal to semiconductor at x=0.30.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unusual oxidation states give reversible room temperature magnetocaloric effect on perovskite-related oxides SrFe{sub 0.5}Co{sub 0.5}O{sub 3}

The magnetic properties and the magnetocaloric effect are presented for the perovskite-related oxide SrFe{sub 0.5}Co{sub 0.5}O{sub 3} prepared using electrochemical oxidation. SrFe{sub 0.5}Co{sub 0.5}O{sub 3} exhibits a second order paramagnetic-ferromagnetic transition close to room temperature (T{sub C}=330 K). The maximal magnetic entropy change {Delta}S{sub M}{sup Max} , the maximal adiabatic temperature change {Delta}T{sub ad} and the refrigerant capacity are found to be equal to respectively 4.0 J/kgK, 1.8 K and 258 J/kg while raising the B-field change from 0 to 5 T. - Graphical Abstract: Moderate but reversible magnetocaloric properties are associated with the 2nd order paramagnetic to ferromagnetic phase transition exhibited at 330 K. A metal-like behavior is seen for the first time on the ferromagnetic regime. Highlights: Black-Right-Pointing-Pointer Both Fe{sup 4+} and Co{sup 4+} are stabilized on perovskite-related phase SrFe{sub 0.5}Co{sub 0.5}O{sub 3} using electrochemical oxidation. Black-Right-Pointing-Pointer Its crystallographic structure is cubic. Black-Right-Pointing-Pointer SrFe{sub 0.5}Co{sub 0.5}O{sub 3} is metal-like/ferromagnetic below 330 K Black-Right-Pointing-Pointer SrFe{sub 0.5}Co{sub 0.5}O{sub 3} exhibits magnetocaloric properties associated with the sharp paramagnetic to ferromagnetic phase transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Criteria for extending the operation periods of thermoelectric converters based on IV-VI compounds

The recent energy demands affected by the dilution of conventional energy resources and the growing awareness of environmental considerations, had positioned the research of renewable energy conversion methods in general and of thermoelectric direct conversion of thermal into electrical energies in particular, in the forefront of the currently active applicative sciences. IV-VI thermoelectric compounds (e.g. GeTe, PbTe and SnTe) and their alloys comprise some of the most efficient thermoelectric compositions ever reported. Yet a proper utilization of such materials in practical thermoelectric devices, still requires an overcoming the so-called technological “valley of death”, including among others, transport properties' degradation, due to sublimation of volatile Te rich species, while being subjected to elevated temperatures for long periods of time. In an attempt to establish practical operation criteria for extending the operation periods of such thermoelectric converters, it is currently shown based on thermal gravimetric and metallurgical considerations that such harmful sublimation can be practically bridged over by limiting the maximal operating temperatures to the 410–430 °C range for GeTe rich alloys and to 510–530 °C for PbTe and SnTe rich alloys, depending of the thermoelectric leg's diameter. - Graphical abstract: Evaporation rate in the GeTe and PbTe system showing the measured evaporation rates and the maximal operating temperatures for different compositions. In addition, the microstructure after evaporation is shown for PbTe, TAGS-85, and doped Pb{sub 0.13}Ge{sub 087}Te. Display Omitted - Highlights: • Evaporation rates of GeTe and PbTe based thermoelectric compounds were determined. • A criterion for their maximum operating temperature was established. • The materials showed phase separations and off-stoichiometry compositions.

36 MATERIALS SCIENCE↗

India National Gas Hydrate Program Expedition 02 Summary of Scientific Results: Numerical Simulation of Reservoir Response to Depressurization

The India National Gas Hydrate Program Expedition 02 (NGHP-02) discovered gas hydrate at high saturation in sand reservoirs at several sites in the deepwater Bay of Bengal. To assess the potential response of those deposits to scientific depressurization experiments, comprehensive geologic models were constructed to enable numerical simulation for two sites. Both sites (NGHP-02-09 and NGHP-02-16) feature thick sequences of thinly-interbedded reservoir and non-reservoir facies at sub-seafloor depths less than 300m and sub-sea depths of 2400m or more. These settings pose significant challenges to current modeling capabilities. First, the thinly-interbedded reservoir architecture complicates the determination of basic reservoir parameters from both log and core data due to measurement resolution issues. Secondly, the fine scale variation in sediment properties imparts great contrasts in key parameters over very short distances, creating high gradients at multiple scales and varying orientations that necessitate careful design of high-definition simulation grids. Thirdly, the deposits include internal sources of water, as well as a range of complex boundary conditions, including variable permeability within the overlying mud-rich “seals,” that complicate reservoir depressurization. Lastly, because of the unique combination of great water depth and relatively shallow sub-seafloor depth: models designed to maximize the dissociation rate impose large pressure drawdowns on relatively low-strength sediments. This condition renders the proper evaluation and integration of the geomechanical response to hydrate dissociation critical. In this report, we review the history of gas hydrate reservoir simulation, discuss methods for creating geologic input models, and summarize the key findings and implications of the collaborative NGHP-02 numerical simulation effort. Together, the studies confirm the viability of the modeled accumulations for scientific testing and identify key challenges related to the selection of specific test sites and the design of test wells.

Boswell, Ray↗

Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution • Novel lab-scale XCT data acquisition and data processing methods • 3D characterization of glass-bead mock plastic-bonded-explosive stimulant.

36 MATERIALS SCIENCE↗

Meta-equilibrium transition microstructure for maximum austenite stability and minimum hardness in a Ti-stabilized supermartensitic stainless steel

We report that the maximization of stable reverted austenite at room temperature through inter-critical tempering is a widely used method to reduce hardness in supermartensitic stainless steels. Nevertheless, partial martensitic transformation might occur due to insufficient compositional stabilization. In this work, we conducted a time-resolved triple-step inter-critical tempering, specially designed to obtain maximum austenite stability and minimum hardness through the progressive suppression of the martensitic transformation. The mechanism behind the progressive increase in stable reverted austenite was the generation of a meta-equilibrium state, which imposed a limit in both high temperature austenite reversion and room temperature austenite stabilization. Such limit corresponded to the high temperature volume fraction of austenite, obtained right before cooling from the first cycle. Additionally, this effect was associated to the Ni-rich fresh martensite laths acting as local Ni compositional pockets, providing site-specific austenite reversion; and to the suppression of any additional nucleation at the Ni-poor matrix as the T0 temperature for austenite reversion was strongly increased. The softening mechanism was mainly controlled by the carbon arrest effect by the precipitation of Ti (C, N), which was completed after the first tempering cycle. Nevertheless, maximizing reverted austenite and suppressing fresh martensite at room temperature did not result in additional hardness reductions.

36 MATERIALS SCIENCE↗

Facile preparation of NiS/CdS-t composite photocatalyst for hydrogen evolution from aqueous solution of sulphide/sulphite under visible light

Highlights: ► The nanostructured NiS/CdS photocatalyst was prepared by a facile two-step method. ► After aged for six days, the photocatalyst achieved a maximal rate of H{sub 2} evolution. ► The rate of H{sub 2} evolution on NiS(0.14)/CdS-6 is about 33 times that of CdS-6. - Abstract: The nanostructured NiS/CdS-t (t = aging period in day number) composite photocatalysts were prepared by a facile two-step synthesis method. The photocatalytic activity of H{sub 2} evolution over NiS/CdS could be greatly enhanced by changing the aging period of CdS. The NiS/CdS achieved a maximal rate of H{sub 2} evolution when CdS was aged for 6 days before hydrothermal treatment. It was demonstrated that the composite NiS(0.14)/CdS-6 could achieve a H{sub 2} evolution rate up to 1517 μmol h{sup −1} and show high photocatalytic stability for H{sub 2} evolution under long-term light irradiation. The rate of H{sub 2} evolution on NiS(0.14)/CdS-6 is about 7.5 times that of NiS(0.14)/CdS-3 and 33 times that of CdS-6. The notable improvement can be attributed to the fast electron transfer from CdS to NiS, which is proved by the surface photovoltage spectroscopy and photoluminescent measurements, as well as the increasing percentage of hexagonal-CdS in the mixture of cubic and hexagonal CdS.

36 MATERIALS SCIENCE↗

A cost-effective process to prepare VO{sub 2} (M) powder and films with superior thermochromic properties

Graphical abstract: Combining codeposition and short time post annealing, VO{sub 2} (M) with high quality and excellent phase transition performance is obtained. After mixing the VO{sub 2} powder with acrylic resin, the composite films deposited on glass show superior visible transmission and solar modulation, which can be used as an excellent candidate of low cost smart window in energy saving field. - Highlights: • The VO{sub 2} powder obtained by short time thermolysis method is high purity and crystallinity with superior phase transition performance. • The maximum decreasing efficiency of phase transition temperature is about −30 K/at% with w = 0.4 at%. • After mixing VO{sub 2} powder with acrylic resin, the maximal visible transmission of the composite films is 48% and the transmission modulation at 2000 nm is 37.3% with phase transition temperature of 66.2 °C. • Though the phase transition performance is weakened by tungsten doping, the film prepared by 1.3 at% tungsten doped VO{sub 2} still show superior transmission modulation about 26.4%, which means that it is a potential candidate as smart windows. - Abstract: VO{sub 2} powder with superior phase transition performance was prepared by convenient thermolysis method. The results illustrated that VO{sub 2} powder show high purity and crystallinity. VO{sub 2} particles are transformed from cluster to quasi-sphere with the increase of annealing temperature. The DSC analysis proves that VO{sub 2} show superior phase transition performance around 68 °C. The phase transition temperature can be reduced to 33.5 °C by 1.8 at% tungsten doping. The maximum decreasing efficiency of phase transition temperature is about −30 K/at% with w = 0.4 at%. After mixing VO{sub 2} powder with acrylic resin, the maximal visible transmission of the composite thin films on glass is 48% and the transmission modulation at 2000 nm is 37.3% with phase transition temperature of 66.2 °C. Though the phase transition performance is weakened by tungsten doping, the film prepared by 1.3 at% tungsten doped VO{sub 2} still show superior transmission modulation about 26.4% at 2000 nm, which means that it is a potential candidate as smart windows.

36 MATERIALS SCIENCE↗

Preliminary Results of Helical Tomotherapy in Patients with Complex-Shaped Meningiomas Close to the Optic Pathway

Meningiomas are the most common benign intracranial tumor. Meningiomas close to the optic pathway represent a treatment challenge both for surgery and radiotherapy. The aim of this article is to describe early results of helical tomotherapy treatment in complex-shaped meningiomas close to the optic pathway. Twenty-eight patients were consecutively treated. All patients were immobilized with a thermoplastic head mask and planned with the aid of a magnetic resonance imaging-computed tomography fusion. All treatments included daily image guidance. Pretreatment symptoms and acute toxicity were recorded. Median age was 57.5 years, and 92.8% patients had Eastern Cooperative Oncology Group performance status scale {<=}1. The most common localizations were the sella turcica, followed by the cavernous sinus and the sphenoid. The most common symptoms were derived from cranial nerve deficits. Tomotherapy was administered as primary treatment in 35.7% of patients, as an adjuvant treatment in 32.4%, and as a rescue treatment after postsurgical progression in 32.1% patients. Most patients were either inoperable or Simpson IV. Total dose varied between 5000 and 5400 cGy; fractionation varied between 180 and 200 cGy. Median dose to the planning target volume was 51.7 Gy (range, 50.2-55.9 Gy). Median coverage index was 0.89 (range, 0.18-0.97). Median homogeneity index was 1.05 (range, 1-1.12). Acute transient toxicity was grade 1 and included headache in 35.7% patients, ocular pain/dryness in 28.5%, and radiation dermatitis in 25%. Thus far, with a maximal follow-up of 3 years, no late effects have been seen and all patients have a radiological stabilization of the disease. Helical tomotherapy offered a safe and effective therapeutic alternative for patients with inoperable or subtotally resected complex-shaped meningiomas close to the optic pathway. Acceptable coverage and homogeneity indexes were achieved with appropriate values for maximal doses delivered to the eyes, lenses, and chiasm, despite the proximity of the tumor to these structures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of two intracavitary high-dose-rate brachytherapy devices for irradiating additional and irregularly shaped volumes of breast tissue

The SAVI and Contura breast brachytherapy applicators represent 2 recent advancements in brachytherapy technology that have expanded the number of women eligible for accelerated partial breast irradiation in the treatment of early-stage breast cancer. Early clinical experience with these 2 single-entry, multichannel high-dose-rate brachytherapy devices confirms their ease of use and dosimetric versatility. However, current clinical guidelines for SAVI and Contura brachytherapy may result in a smaller or less optimal volume of treated tissue compared with traditional interstitial brachytherapy. This study evaluates the feasibility of using the SAVI and Contura to irradiate larger and irregularly shaped target volumes, approaching what is treatable with the interstitial technique. To investigate whether additional tissue can be treated, 17 patients treated with the SAVI and 3 with the Contura were selected. For each patient, the planning target volume (PTV) was modified to extend 1.1 cm, 1.3 cm, and 1.5 cm beyond the tumor bed cavity. To evaluate dose conformance to an irregularly shaped target volume, 9 patients treated with the SAVI and 3 with the Contura were selected from the original 20 patients. The following asymmetric PTV margin combinations were assessed for each patient: 1.5/0.3, 1.3/0.3, and 1.1/0.3 cm. For all patients, treatment planning was performed, adopting the National Surgical Adjuvant Breast and Bowel Project guidelines, and dosimetric comparisons were made. The 6-1 and 8-1 SAVI devices can theoretically treat a maximal tissue margin of 1.5 cm and an asymmetric PTV with margins ranging from 0.3 to 1.5 cm. The 10-1 SAVI and Contura can treat a maximal margin of 1.3 cm and 1.1 cm, respectively, and asymmetric PTV with margins ranging from 0.3-1.3 cm. Compared with the Contura, the SAVI demonstrated greater dosimetric flexibility. Risk of developing excessive hot spots increased with the size of the SAVI device. Both the SAVI and Contura appear capable of treating >1.0-cm margins and irregularly shaped PTVs. The 6-1 SAVI device demonstrated the greatest versatility in targeting PTVs approaching what is treatable using the interstitial technique.

61 RADIATION PROTECTION AND DOSIMETRY↗