Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MOTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Motional Squeezing for Trapped Ion Transport and Separation

Transport, separation, and merging of trapped ion crystals are essential operations for most large-scale quantum computing architectures. In this Letter, we develop a theoretical framework that describes the dynamics of ions in time-varying potentials with a motional squeeze operator, followed by a motional displacement operator. Using this framework, we develop a new, general protocol for trapped ion transport, separation, and merging. We show that motional squeezing can prepare an ion wave packet to enable transfer from the ground state of one trapping potential to another. Here, the framework and protocol are applicable if the potential is harmonic over the extent of the ion wave packets at all times. As illustrations, we discuss two specific operations: changing the strength of the confining potential for a single ion and separating same-species ions with their mutual Coulomb force. Both of these operations are, ideally, free of residual motional excitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of Multimode Motional Quantum States in a Trapped Ion System

Trapped atomic ions are a versatile platform for studying interactions between spins and bosons by coupling the internal states of the ions to their motion. Measurement of complex motional states with multiple modes is challenging, because all motional state populations can only be measured indirectly through the spin state of ions. Here we present a general method to determine the Fock state distributions and to reconstruct the density matrix of an arbitrary multimode motional state. Further, we experimentally verify the method using different entangled states of multiple radial modes in a five-ion chain. This method can be extended to any system with Jaynes-Cummings-type interactions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Raman Sideband Cooling of Molecules in an Optical Tweezer Array to the 3D Motional Ground State

Ultracold polar molecules are promising for quantum information processing and searches for physics beyond the standard model. Laser cooling to ultracold temperatures is an established technique for trapped diatomic and triatomic molecules. Further cooling of the molecules to near the motional ground state is crucial for reducing various dephasings in quantum and precision applications. In this work, we demonstrate Raman sideband cooling (RSC) of CaF molecules in optical tweezers to near their motional ground state, with average motional occupation quantum numbers of n ¯ x = 0.16 ( 12 ) , n ¯ y = 0.17 ( 17 ) (radial directions), and n ¯ z = 0.22 ( 16 ) (axial direction), and a 3-D motional-ground-state probability of 54 ± 18 % of the molecules that survive the RSC. This process paves the way to increase molecular coherence times in optical tweezers for robust quantum computation and simulation applications. Published by the American Physical Society 2024

Physics↗

HIL Testbed and Motion Control Strategy for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) was proposed in recent years to increase system efficiency of high power mobile machines and to reap the benefits of electrification without the need for large electric machines. It uses a set of common pressure rails to provide the majority of power hydraulically and small electric motors to modulate that power for precise control. This paper presents the development of a Hardware-in-the-loop (HIL) test-bed for testing motion control strategies for the HHEA. Precise motion control is important for off-road vehicles whose utility requires the machine being dexterous and performing tasks exactly as commanded. Motion control for the HHEA is challenging due to its intrinsic use of discrete pressure rail switches to minimize system efficiency or to keep the system within the torque capabilities of the electric motor. The motion control strategy utilizes two different controllers: a nominal passivity based back-stepping controller used in between pressure rail switches and a transition controller used to handle the event of a pressure rail switch. In this paper, the performance of the nominal control under various nominal and rail switching scenarios is experimentally evaluated on the HIL testbed.

33 ADVANCED PROPULSION SYSTEMS↗

Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Software-controlled, highly automated intrafraction prostate motion correction with intrafraction stereographic targeting: System description and clinical results

Purpose: A new system for software-controlled, highly automated correction of intrafraction prostate motion,'' intrafraction stereographic targeting'' (iSGT), is described and evaluated. Methods: At our institute, daily prostate positioning is routinely performed at the start of treatment beam using stereographic targeting (SGT). iSGT was implemented by extension of the SGT software to facilitate fast and accurate intrafraction motion corrections with minimal user interaction. iSGT entails megavoltage (MV) image acquisitions with the first segment of selected IMRT beams, automatic registration of implanted markers, followed by remote couch repositioning to correct for intrafraction motion above a predefined threshold, prior to delivery of the remaining segments. For a group of 120 patients, iSGT with corrections for two nearly lateral beams was evaluated in terms of workload and impact on effective intrafraction displacements in the sagittal plane. Results: SDs of systematic ({Sigma}) and random ({sigma}) displacements relative to the planning CT measured directly after initial SGT setup correction were <0.5 and <0.8 mm, respectively. Without iSGT corrections, effective {Sigma} and {sigma} for the 11-min treatments would increase to {Sigma}{sub eff} < 1.1 mm and {sigma}{sub eff} < 1.2 mm. With the iSGT procedure with an action level of 4 mm, effective positioning errors were reduced to {Sigma}{sub eff} < 0.8 mm and {sigma}{sub eff} < 1.0 mm, with 23.1% of all fractions requiring a correction. Computer simulations demonstrated that with an action level of 2 mm, the errors would have been reduced to {Sigma}{sub eff} < 0.6 mm and {sigma}{sub eff} < 0.7 mm, requiring corrections in 82.4% of the fractions. Because iSGT is highly automated, the extra time added by iSGT is <30 s if a correction is required. Conclusions: Without increasing imaging dose, iSGT successfully reduces intrafraction prostate motion with minimal workload and increase in fraction time. An action level of 2 mm is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality control procedures for dynamic treatment delivery techniques involving couch motion

In this study, the authors introduce and demonstrate quality control procedures for evaluating the geometric and dosimetric fidelity of dynamic treatment delivery techniques involving treatment couch motion synchronous with gantry and multileaf collimator (MLC). Tests were designed to evaluate positional accuracy, velocity constancy and accuracy for dynamic couch motion under a realistic weight load. A test evaluating the geometric accuracy of the system in delivering treatments over complex dynamic trajectories was also devised. Custom XML scripts that control the Varian TrueBeam™ STx (Serial #3) axes in Developer Mode were written to implement the delivery sequences for the tests. Delivered dose patterns were captured with radiographic film or the electronic portal imaging device. The couch translational accuracy in dynamic treatment mode was 0.01 cm. Rotational accuracy was within 0.3°, with 0.04 cm displacement of the rotational axis. Dose intensity profiles capturing the velocity constancy and accuracy for translations and rotation exhibited standard deviation and maximum deviations below 3%. For complex delivery involving MLC and couch motions, the overall translational accuracy for reproducing programmed patterns was within 0.06 cm. The authors conclude that in Developer Mode, TrueBeam™ is capable of delivering dynamic treatment delivery techniques involving couch motion with good geometric and dosimetric fidelity.

60 APPLIED LIFE SCIENCES↗

SU-D-18A-01: Tumor Motion Tracking with a Regional Deformable Registration Model for Four Dimensional Radiation Treatment of Lung Cancer

Purpose: To develop a tumor motion model from four-dimensional computed tomography (4DCT) of thoracic patients and demonstrate its impact on 4D radiation therapy simulation. Methods: A regional deformable image registration algorithm was introduced to extract tumor motion out of patient's breathing cycle. The gross target volume (GTV) was manually delineated on a selected phase of 4DCT and a subregion with 10mm margin supplemented to the GTV was created on the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). Together with 4DCT the structures were exported into an inhouse research platform. A free form B-Spline deformable registration was carried out to map the subregion to other respiratory phases. The displacement vector fields were employed to propagate GTV contours with which the center of mass (CoM) of the GTV was computed for each breathing phase of 4DCT. The resultant GTV motion and its volumetric shape are utilized to facilitate 4D treatment planning. Five lung cancer patients undergoing stereotactic body radiation therapy were enrolled and their 4DCT sets were included in the study. Results: Application of the algorithm to five thoracic patients indicates that clinically satisfactory outcomes were achievable with a spatial accuracy better than 2mm for GTV contour propagation between adjacent phases, and 3mm between opposite phases. The GTV CoM was found to be in the range of 2.0mm through 2.5cm, depending upon the tumor location. Compared to the traditional whole image based registration, the computation of the regional model was found to be an order of magnitude more efficient. Conclusion: A regional deformable registration model was implemented to extract tumor motion. It will have widespread application in 4D radiation treatment planning in the future to maximally utilize the available spatial-tempo information.

60 APPLIED LIFE SCIENCES↗

SU-E-I-51: Use of Blade Sequences in Cervical Spine MR Imaging for Eliminating Motion, Truncation and Flow Artifacts

Purpose: To assess the efficacy of the BLADE technique to eliminate motion, truncation, flow and other artifacts in Cervical Spine MRI compared to the conventional technique. To study the ability of the examined sequences to reduce the indetention and wrap artifacts, which have been reported in BLADE sagittal sequences. Methods: Forty consecutive subjects, who had been routinely scanned for cervical spine examination using four different image acquisition techniques, were analyzed. More specifically, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0:non-visualization; 1:poor; 2:average; 3:good; 4:excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). Results: Based on the findings of the quantitative analysis, the ReCON values of the CSF (cerebrospinal fluid)/SC (spinal cord) between TIRM SAG and TIRM SAG BLADE were found to present statistical significant differences (p<0.001). Regarding motion and truncation artifacts, the T2 TSE SAG BLADE was superior compared to the T2 TSE SAG and the T2 TIRM SAG BLADE was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM SAG BLADE eliminated more artifacts compared to the T2 TIRM SAG. Conclusion: The use of BLADE sequences in cervical spine MR examinations appears to be capable of potentially eliminating motion, pulsatile flow and trancation artifacts. Furthermore, BLADE sequences are proposed to be used in the standard examination protocols based on the fact that a significantly improved image quality could be achieved.

60 APPLIED LIFE SCIENCES↗

SU-E-J-63: Estimating the Effects of Respiratory Motion On Dose Heterogeneity for ITV-Based Treatments

Purpose: To quantify the relationship between the amount of dose heterogeneity in a treatment plan that uses an internal target volume (ITV) to account for respiratory motion and the true amount of heterogeneity in the dose delivered to the tumor contained within that ITV. Methods: We develop a convolution-based framework for calculating dose delivered to a tumor moving inside an ITV according to a common sinusoid-based breathing model including asymmetry. We model the planned ITV dose distribution as a centrally peaked analytic function approximating the profile of clinical stereotactic body radiotherapy treatments. Expressions for the minimum and maximum dose received by the tumor are derived and evaluated for a range of clinically relevant parameters. Results of the model are validated with phantom measurements using an ion chamber array. Results: An analytic expression is presented for the maximum and minimum doses received by the tumor relative to the planned ITV dose. The tumor dose heterogeneity depends solely on the ratio of tumor size to ITV size, the peak dose in the planned ITV dose distribution, and the respiratory asymmetry parameter. Under the assumptions of this model, using a typical breathing asymmetry parameter and a dose distribution with a fixed size ITV covered by the 100% line and with a 130% hotspot, the maximum dose to the tumor varies between 113%–130%, and the minimum dose varies between 100%–116% depending on the amount of tumor motion. Conclusion: This modeling exercise demonstrates the interplay between motion and dose heterogeneity. Tumors that exhibit large amounts of respiratory motion relative to their size will receive a more homogeneous dose and a larger minimum dose than would be inferred from the ITV dose distribution. This effect is not captured in current clinical treatment planning methods unless 4D dose calculation techniques are used. This work was partially supported by a Varian Medical Systems research grant.

60 APPLIED LIFE SCIENCES↗

SU-E-J-74: Impact of Respiration-Correlated Image Quality On Tumor Motion Reconstruction in 4D-CBCT: A Phantom Study

Purpose: To investigate the effects of scanning parameters and respiratory patterns on the image quality for 4-dimensional cone-beam computed tomography(4D-CBCT) imaging, and assess the accuracy of computed tumor trajectory for lung imaging using registration of phased 4D-CBCT imaging with treatment planning-CT. Methods: We simulated a periodic and non-sinusoidal respirations with various breathing periods and amplitudes using a respiratory phantom(Quasar, Modus Medical Devices Inc) to acquire respiration-correlated 4D-CBCT images. 4D-CBCT scans(Elekta Oncology Systems Ltd) were performed with different scanning parameters for collimation size(e.g., small and medium field-of-views) and scanning speed(e.g., slow 50°·min{sup −1}, fast 100°·min{sup −1}). Using a standard CBCT-QA phantom(Catphan500, The Phantom Laboratory), the image qualities of all phases in 4D-CBCT were evaluated with contrast-to-noise ratio(CNR) for lung tissue and uniformity in each module. Using a respiratory phantom, the target imaging in 4D-CBCT was compared to 3D-CBCT target image. The target trajectory from 10-respiratory phases in 4D-CBCT was extracted using an automatic image registration and subsequently assessed the accuracy by comparing with actual motion of the target. Results: Image analysis indicated that a short respiration with a small amplitude resulted in superior CNR and uniformity. Smaller variation of CNR and uniformity was present amongst different respiratory phases. The small field-of-view with a partial scan using slow scan can improve CNR, but degraded uniformity. Large amplitude of respiration can degrade image quality. RMS of voxel densities in tumor area of 4D-CBCT images between sinusoidal and non-sinusoidal motion exhibited no significant difference. The maximum displacement errors of motion trajectories were less than 1.0 mm and 13.5 mm, for sinusoidal and non-sinusoidal breathings, respectively. The accuracy of motion reconstruction showed good overall agreement with the 4D-CBCT image quality results only using sinusoidal breathings. Conclusion: This information can be used to determine the appropriate acquisition parameters of 4D-CBCT imaging for registration accuracy and target trajectory measurements in a clinical setting.

60 APPLIED LIFE SCIENCES↗

SU-E-J-172: A Quantitative Assessment of Lung Tumor Motion Using 4DCT Imaging Under Conditions of Controlled Breathing in the Management of Non-Small Cell Lung Cancer (NSCLC) Using Stereotactic Body Radiation Therapy (SBRT)

Purpose: To study breathing related tumor motion amplitudes by lung lobe location under controlled breathing conditions used in Stereotactic Body Radiation Therapy (SBRT) for NSCLC. Methods: Sixty-five NSCLC SBRT patients since 2009 were investigated. Patients were categorized based on tumor anatomic location (RUL-17, RML-7, RLL-18, LUL-14, LLL-9). A 16-slice CT scanner [GE RT16 Pro] along with Varian Realtime Position Management (RPM) software was used to acquire the 4DCT data set using 1.25 mm slice width. Images were binned in 10 phases, T00 being at maximum inspiration ' T50 at maximum expiration phase. Tumor volume was segmented in T50 using the CT-lung window and its displacement were measured from phase to phase in all three axes; superiorinferior, anterior-posterior ' medial-lateral at the centroid level of the tumor. Results: The median tumor movement in each lobe was as follows: RUL= 3.8±2.0 mm (mean ITV: 9.5 cm{sup 3}), RML= 4.7±2.8 mm (mean ITV: 9.2 cm{sup 3}), RLL=6.6±2.6 mm (mean ITV: 12.3 cm{sup 3}), LUL=3.8±2.4 mm (mean ITV: 18.5 cm{sup 3}), ' LLL=4.7±2.5 mm (mean ITV: 11.9 cm{sup 3}). The median respiratory cycle for all patients was found to be 3.81 ± 1.08 seconds [minimum 2.50 seconds, maximum 7.07 seconds]. The tumor mobility incorporating breathing cycle was RUL = 0.95±0.49 mm/s, RML = 1.35±0.62 mm/s, RLL = 1.83±0.71 mm/s, LUL = 0.98 ±0.50 mm/s, and LLL = 1.15 ±0.53 mm/s. Conclusion: Our results show that tumor displacement is location dependent. The range of motion and mobility increases as the location of the tumor nears the diaphragm. Under abdominal compression, the magnitude of tumor motion is reduced by as much as a factor of 2 in comparison to reported tumor magnitudes under conventional free breathing conditions. This study demonstrates the utility of abdominal compression in reducing the tumor motion leading to reduced ITV and planning tumor volumes (PTV)

60 APPLIED LIFE SCIENCES↗

SU-E-J-199: Evaluation of Motion Tracking Effects On Stereotactic Body Radiotherapy of Abdominal Targets

Purpose: To evaluate the effects of respiratory motion on the delivered dose distribution of CyberKnife motion tracking-based stereotactic body radiotherapy (SBRT) of abdominal targets. Methods: Four patients (two pancreas and two liver, and all with 4DCT scans) were retrospectively evaluated. A plan (3D plan) using CyberKnife Synchrony was optimized on the end-exhale phase in the CyberKnife's MultiPlan treatment planning system (TPS), with 40Gy prescribed in 5 fractions. A 4D plan was then created following the 4D planning utility in the MultiPlan TPS, by recalculating dose from the 3D plan beams on all 4DCT phases, with the same prescribed isodose line. The other seven phases of the 4DCT were then deformably registered to the end-exhale phase for 4D dose summation. Doses to the target and organs at risk (OAR) were compared between 3D and 4D plans for each patient. The mean and maximum doses to duodenum, liver, spinal cord and kidneys, and doses to 5cc of duodenum, 700cc of liver, 0.25cc of spinal cord and 200cc of kidneys were used. Results: Target coverage in the 4D plans was about 1% higher for two patients and about 9% lower in the other two. OAR dose differences between 3D and 4D varied among structures, with doses as much as 8.26Gy lower or as much as 5.41Gy higher observed in the 4D plans. Conclusion: The delivered dose can be significantly different from the planned dose for both the target and OAR close to the target, which is caused by the relative geometry change while the beams chase the moving target. Studies will be performed on more patients in the future. The differences of motion tracking versus passive motion management with the use of internal target volumes will also be investigated.

60 APPLIED LIFE SCIENCES↗

SU-E-J-268: Is It Necessary to Account for Organs at Risk Respiratory Induced Motion Effects in Radiotherapy Planning with Tumor Tracking?

Purpose: The objective of this study was to evaluate the necessity to account for the organs at risk (OARs) respiratory induced motion in addition to the tumor displacement when planning a radiotherapy treatment that accounts for tumor motion. Methods: For 18 lung cancer patients, conformational radiotherapy treatment plans were generated using 3 different CT volumes: the two extreme respiratory phases corresponding to either the full inspiration (plan 1) or expiration (plan 3), as well as a manually deformed phase consisting in full inspiration combined with the full expiration tumor location (plan 2) simulating a tumor tracking plan without addressing OARs motion. Treatment plans were initially created on plan 1 and then transferred to plan 2 and 3 which represent respectively the tumor displacement only and the whole anatomic variations due to breathing. The dose coverage and the dose delivered to the OARs were compared using conformational indexes and generalized equivalent uniform dose. Results: The worst conformational indexes were obtained for plans with all anatomic deformations (Table 1) with an underestimation of the 95% isodose spreading on healthy tissue compared to plans considering the tumor displacement only. Furthermore, mean doses to the OARs when accounting for all the anatomic changes were always higher than those associated with the tumor displacement only: the mean difference between these two plans was 1±1.37 Gy (maximum of 3.8 Gy) for the heart and 1.4±1.42 Gy (maximum of 4.1 Gy) for the lung in which the tumor was located (Figure 1). Conclusion: OARs deformations due to breathing motion should be included in the treatment planning in order to avoid unnecessary OARs dose and/or allow for a tumor dose escalation. This is even more important for treatments like stereotactic radiation therapy which necessitates a high precision ballistic and dose control.

60 APPLIED LIFE SCIENCES↗

SU-E-T-163: Evaluation of Dose Distributions Recalculated with Per-Field Measurement Data Under the Condition of Respiratory Motion During IMRT for Liver Cancer

Purpose: The dose distributions within the real volumes of tumor targets and critical organs during internal target volume-based intensity-modulated radiation therapy (ITV-IMRT) for liver cancer were recalculated by applying the effects of actual respiratory organ motion, and the dosimetric features were analyzed through comparison with gating IMRT (Gate-IMRT) plan results. Methods: The 4DCT data for 10 patients who had been treated with Gate-IMRT for liver cancer were selected to create ITV-IMRT plans. The ITV was created using MIM software, and a moving phantom was used to simulate respiratory motion. The period and range of respiratory motion were recorded in all patients from 4DCT-generated movie data, and the same period and range were applied when operating the dynamic phantom to realize coincident respiratory conditions in each patient. The doses were recalculated with a 3 dose-volume histogram (3DVH) program based on the per-field data measured with a MapCHECK2 2-dimensional diode detector array and compared with the DVHs calculated for the Gate-IMRT plan. Results: Although a sufficient prescription dose covered the PTV during ITV-IMRT delivery, the dose homogeneity in the PTV was inferior to that with the Gate-IMRT plan. We confirmed that there were higher doses to the organs-at-risk (OARs) with ITV-IMRT, as expected when using an enlarged field, but the increased dose to the spinal cord was not significant and the increased doses to the liver and kidney could be considered as minor when the reinforced constraints were applied during IMRT plan optimization. Conclusion: Because Gate-IMRT cannot always be considered an ideal method with which to correct the respiratory motional effect, given the dosimetric variations in the gating system application and the increased treatment time, a prior analysis for optimal IMRT method selection should be performed while considering the patient's respiratory condition and IMRT plan results.

60 APPLIED LIFE SCIENCES↗

SU-E-T-538: Does Abdominal Compression Through Prone Patient Position Reduce Respiratory Motion in Lung Cancer Radiotherapy?

Purpose: This study assesses the effect of physiological abdominal compression from prone positioning by comparing respiratory-induced tumor movements in supine and prone positions. Methods: 19 lung cancer patients underwent repeated supine and prone free-breathing 4DCT scans. The effect of patient position on motion magnitude was investigated for tumors, lymph nodes (9 cases), and subgroups of central (11 cases), peripheral (8 cases) and small peripheral tumors (5 cases), by evaluating the population average excursions, absolute and relative to a carina-point. Results: Absolute motion analysis: In prone, motion increased by ~20% for tumors and ~25% for lymph nodes. Central tumors moved more compared to peripheral tumors in both supine and prone (~22%, and ~4% respectively). Central tumors movement increased by ~12% in prone. For peripheral tumors the increase in prone position was ~25% (~40% and 29% changes on along RL and AP directions). Motion relative to carina-point analysis: Overall, tumor excursions relative to carina-point increased by ~17% in prone. Lymph node relative magnitudes were lower by ~4%. Likewise, the central tumors moved ~7% less in prone. The subgroup of peripheral tumors exhibited increased amplitudes by ~44%; the small peripheral tumors had even larger relative displacements in prone (~46%). Conclusion: Tumor and lymph node movement in the patient population from this study averaged to be higher in prone than in supine position. Results from carina analysis also suggest that peripheral tissues have more physiologic freedom of motility when placed in the prone position, regardless of size. From these observations we should continue to avoid prone positioning for all types of primary lung tumor, suggesting that patients should receive radiotherapy for primary lung cancer in supine position to minimize target tissue mobility during normal respiratory effort. Further investigation will include more patients with peripheral tumors to validate our observations.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-T-02: Can Pre-Treatment 4DCT-Based Motion Margins Estimates Be Trusted for Proton Radiotherapy?

Purpose: Radiotherapy motion margins are generated using pre-treatment 4DCT data. The purpose of this study is to assess if pre-treatment 4DCT is sufficient in proton therapy to provide accurate estimate of motion margins. A dosimetric assessment is performed comparing pre-treatment margins with daily-customized margins. Methods: Gold fiducial markers implanted in lung tumors of patients were used to track the tumor. A spherical tumor of diameter 20 mm is inserted into a realistic digital respiratory phantom, where the tumor motion is based on real patient lung tumor trajectories recorded over multiple days. Using “Day 1” patient data, 100 ITVs were generated with 1 s interval between consecutive scan start times. Each ITV was made up by the union of 10 tumor positions obtained from 6 s scan time. Two ITV volumes were chosen for treatment planning: ITVmean-σ and ITVmean+σ. The delivered dose was computed on i) 10 phases forming the planning ITV (“10-phase” - simulating dose calculation based on 4DCT) and ii) 50 phantoms produced from 100 s of data from any other day with tumor positions sampled every 2 s (“dynamic” - simulating the dose that would actually be delivered). Results: For similar breathing patterns between “Day 1” and any other “Day N(>1)”, the 95% volume coverage (D95) for “dynamic” case was 8.13% lower than the “10-phase” case for ITVmean+σ. For breathing patterns that were very different between “Day 1” and any other “Day N(>1)”, this difference was as high as 24.5% for ITVmean-σ. Conclusion: Proton treatment planning based on pre-treatment 4DCT can lead to under-dosage of the tumor and over-dosage of the surrounding tissues, because of inadequate estimate of the range of motion of the tumor. This is due to the shift of the Bragg peak compared to photon therapy in which the tumor is surrounded by an electron bath.

60 APPLIED LIFE SCIENCES↗

MO-G-BRF-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - Sensitivity of PET-Based Texture Features to Respiratory Motion in Non-Small Cell Lung Cancer (NSCLC)

Purpose: PET-based texture features are used to quantify tumor heterogeneity due to their predictive power in treatment outcome. We investigated the sensitivity of texture features to tumor motion by comparing whole body (3D) and respiratory-gated (4D) PET imaging. Methods: Twenty-six patients (34 lesions) received 3D and 4D [F-18]FDG-PET scans before chemo-radiotherapy. The acquired 4D data were retrospectively binned into five breathing phases to create the 4D image sequence. Four texture features (Coarseness, Contrast, Busyness, and Complexity) were computed within the the physician-defined tumor volume. The relative difference (δ) in each measure between the 3D- and 4D-PET imaging was calculated. Wilcoxon signed-rank test (p<0.01) was used to determine if δ was significantly different from zero. Coefficient of variation (CV) was used to determine the variability in the texture features between all 4D-PET phases. Pearson correlation coefficient was used to investigate the impact of tumor size and motion amplitude on δ. Results: Significant differences (p<<0.01) between 3D and 4D imaging were found for Coarseness, Busyness, and Complexity. The difference for Contrast was not significant (p>0.24). 4D-PET increased Busyness (∼20%) and Complexity (∼20%), and decreased Coarseness (∼10%) and Contrast (∼5%) compared to 3D-PET. Nearly negligible variability (CV=3.9%) was found between the 4D phase bins for Coarseness and Complexity. Moderate variability was found for Contrast and Busyness (CV∼10%). Poor correlation was found between the tumor volume and δ for the texture features (R=−0.34−0.34). Motion amplitude had moderate impact on δ for Contrast and Busyness (R=−0.64− 0.54) and no impact for Coarseness and Complexity (R=−0.29−0.17). Conclusion: Substantial differences in textures were found between 3D and 4D-PET imaging. Moreover, the variability between phase bins for Coarseness and Complexity was negligible, suggesting that similar quantification can be obtained from all phases. Texture features, blurred out by respiratory motion during 3D-PET acquisition, can be better resolved by 4D-PET imaging with any phase.

60 APPLIED LIFE SCIENCES↗