Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

In-situ x-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ x ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (0)1, (0)3, (0)5, and (0)8 composite specimens, showed that x ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.

Baaklini, George Y.↗

Nondestructive evaluation tools and experimental studies for monitoring the health of space propulsion systems

An overview is given of background and information on space propulsion systems on both the programmatic and technical levels. Feasibility experimental studies indicate that nondestructive evaluation tools such as ultrasonic, eddy current and x-ray may be successfully used to monitor the life limiting failure mechanisms of space propulsion systems. Encouraging results were obtained for monitoring the life limiting failure mechanisms for three space propulsion systems; the degradation of tungsten arcjet and magnetoplasmadynamic electrodes; presence and thickness of spallable electrically conducting molybdenum films in ion thrusters; and the degradation of the catalyst in hydrazine thrusters.

Generazio, Edward R.↗

Biofilm monitoring coupon system and method of use

An apparatus and method is disclosed for biofilm monitoring of a water distribution system which includes the mounting of at least one fitting in a wall port of a manifold in the water distribution system with a passage through the fitting in communication. The insertion of a biofilm sampling member is through the fitting with planar sampling surfaces of different surface treatment provided on linearly arrayed sample coupons of the sampling member disposed in the flow stream in edge-on parallel relation to the direction of the flow stream of the manifold under fluid-tight sealed conditions. The sampling member is adapted to be aseptically removed from or inserted in the fitting and manifold under a positive pressure condition and the fitting passage sealed immediately thereafter by appropriate closure means so as to preclude contamination of the water distribution system through the fitting. The apparatus includes means for clamping the sampling member and for establishing electrical continuity between the sampling surfaces and the system for minimizing electropotential effects. The apparatus may also include a plurality of fittings and sampling members mounted on the manifold to permit extraction of the sampling members in a timed sequence throughout the monitoring period.

Sauer, Richard L.↗

Operation and performance of the Ciba-Corning 512 coagulation monitor during parabolic flight

The goal was to assess the functionality and evaluate the procedures and operations required to operate the Ciba-Corning 512 Coagulation Monitor during parabolic flight. This monitor determines the clotting characteristics of blood. The analyzer operates by laser detection of the cessation of blood flow in a capillary channel within a test cartridge. Test simulator results were excellent for both pre-and post-flight. In-flight results were not obtained due to the warm-up time required for the simulator. Since this is an electronic function only, the expected results on the simulator would be the same in zero-g.

Gocke, Robyn↗

Structural monitoring of filamentary composites using embedded fiber optics

The feasibility of monitoring overall integrity of structural components made of filamentary composites, by embedding optical fibers between lamina of a composite beam, is investigated using a beam constructed of Kevlar/epoxy cloth with embedded optical fibers aligned with the longitudinal axis of the beam. Phase changes were monitored in three different optical fibers as the composite beam was subjected to pure bending, and the strain response of the fibers was compared to the strain gage readings taken at the surface, showing a strong correlation between the phase change and the applied deformation.

Cashon, John L.↗

Annual Health Monitoring Conference for Space Propulsion Systems, 2nd, Cincinnati, OH, Nov. 14, 15, 1990, Proceedings

This conference discusses health management systems for liquid rocket engines, signal processing of spectroscopic data for engine diagnostic applications, real-time diagnostics of the reusable rocket engine using on-line system identification, and nonlinear parameter estimation for rocket engine health monitoring. Plume diagnostics are considered including discussion on preliminary plume diagnostics on the SSME using video digitization techniques and baseline plume emmissions. The development of a Fabry-Perot Interferometer for rocket engine plumes is also considered. The topic of computational modeling is also discussed, addressing such topics as probabalistic dynamics of material loss in the SSME turbomachinery, state-variable modelling of fluid-dynamics processes, and a model for the SSME high pressure oxidizer turbopump shaft seal system. A discussion of sensor development includes the topics of sensor development for the rocket engine condition monitoring system and the heat flux measurements in SSME turbine blade tester.

Source record↗

Real-time reasoning - The monitoring and control of spacecraft systems

Research concerned with automating the monitoring and control of spacecraft systems is discussed. In particular, the application the Procedural Reasoning System (PRS) to the handling of malfunctions in the Reaction Control System (RCS) of NASAs space shuttle is studied. Unlike traditional monitoring and control systems, PRS is able to reason about and perform complex tasks in a very flexible and robust manner, somewhat in the manner of a human assistant. Using various RCS malfunctions as examples (including sensor faults, leaking components, multiple alarms, and regulator and jet failures), it is shown how PRS manages to combine both goal-directed reasoning and the ability to react rapidly to unanticipated changes in its environment. Some important issues in the design of PRS are reviewed, and future enhancements are indicated.

Georgeff, Michael P.↗

Long-term remote monitoring of salt marsh biomass

Methods developed for monitoring salt-marsh biomass remotedly are considered in the framework of NASA's Biospheric Research Program. Satellite-derived estimates of the aboveground biomass is considered, and it is noted that a long-term program for long-term remote monitoring is only practical if the relationship between biomass and spectral data remains essentially constant from year to year. Emphasis is placed on ground-based sampling, satellite measurements of mean marsh live aboveground biomass, the spatial distribution of biomass within the marsh, and changes in marsh hydrography as seen from a satellite. Linking aboveground and belowground biomass is discussed, as well as the problem with obtaining cloud-free images and measuring dead biomass.

Gross, M. F.↗

Automating security monitoring and analysis for Space Station Freedom's electric power system

Operating a large, space power system requires classifying the system's status and analyzing its security. Conventional algorithms are used by terrestrial electric utilities to provide such information to their dispatchers, but their application aboard Space Station Freedom will consume too much processing time. A novel approach for monitoring and analysis using adaptive pattern techniques is presented. This approach yields an on-line security monitoring and analysis algorithm that is accurate and fast; and thus, it can free the Space Station Freedom's power control computers for other tasks.

Dolce, James L.↗

Plastic scintillator block as photon beam monitor for EGRET calibration

The EGRET (Energetic Gamma Ray Experiment Telescope) detector has been calibrated at SLAC (Stanford Linear Accelerator) and, to a lesser degree, at the MIT Bates Linear Accelerator Center. To monitor the photon beams for the calibration, a plastic scintillator block, 5 cm x 5 cm in cross section, 15 cm in length, and viewed by a single photomultiplier tube, was used for the entire beam energy range of 15 MeV to 10 GeV. The design operation, and method of analysis of the beam intensity are presented. A mathematical framework has been developed to treat the general case of a beam with multiphoton beam pulses and with a background component. A procedure to deal with the fluctuations of the beam intensity over a data-taking period was also developed. The photon beam monitor is physically sturdy, electronically steady, simple to construct, and easy to operate. Its major merits lie in its sheer simplicity of construction and operation and in the wide energy range it can cover.

Lin, Y. C.↗

In-service health monitoring of composite structures

The aerospace industry is witnessing a vast utilization of composites in critical structural applications and anticipates even more use of them in future aircraft. Therefore, a definite need exists for a composite health monitoring expert system to meet today's current needs and tomorrow's future demands. The primary goal for this conceptual health monitoring system is functional reliably for in-service operation in the environments of various composite structures. The underlying philosophy of this system is to utilize proven vibration techniques to assess the structural integrity of a fibrous composite. Statistical methods are used to determine if the variances in the measured data are acceptable for making a reliable decision on the health status of the composite. The flexible system allows for algorithms describing any composite fatigue or damage behavior characteristic to be provided as an input to the system. Alert thresholds and variances can also be provided as an input to this system and may be updated to allow for future changes/refinements in the composite's structural integrity behavior.

Pinto, Gino A.↗

An advanced condition monitoring system for turbopumps

Advanced condition monitoring (ACM) technologies developed for in situ turbomachinery applications are reviewed. The ACM concepts are based on direct in situ hardware monitoring and between-flight inspections, using novel real-time, automated, noncontacting, and nonintrusive sensor and associated electronic technologies.

Cross, George S.↗

Nondestructive evaluation tools and experimental studies for monitoring the health of space propulsion systems

An overview is given of background and information on space propulsion systems on both the programmatic and technical levels. Feasibility experimental studies indicate that nondestructive evaluation tools such as ultrasonic, eddy current and X-ray may be successfully used to monitor the life limiting failure mechanisms of space propulsion systems. Encouraging results were obtained for monitoring the life limiting failure mechanims for three space propulsion systems: the degradation of tungsten arcjet and magnetoplasmadynamic electrodes; presence and thickness of spallable electrically conducting molybdenum films in ion thrusters; and the degradation of the catalyst in hydrazine thrusters.

Generazio, Edward R.↗

In situ X-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ X-ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (O)1, (O)3, (O)5, and (O)8 composite specimens showed that X-ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.

Baaklini, George Y.↗

Monitoring Jupiter's hectometric emission

The feasibility of long-term monitoring of the Jovian hectometric radiation component (nominal range between 0.3 to 3 MHz) is considered. It is recommended that long-term monitoring of Jupiter at frequencies around 1 MHz should be conducted either from a high-orbit earth satellite or from the surface of the moon. Such a program would eventually provide a record of rotation period changes revealing secular variations in the Jovian magnetic field, with a sensitivity much higher than could be achieved from the earth.

Carr, Thomas D.↗

Airplane-Runway-Performance Monitoring System

Airplane-Runway-Performance Monitoring System (ARPMS) increases safety during takeoffs and landings by providing pilots with symbolic "head-up" and "head-down" information pertinent to decisions to continue or abort takeoffs or landings. Provides graphic information concerning where airplane could be stopped. Pilot monitors ground speed and predicted stopping point while looking at actual runway. High potential for incorporation into cockpit environment for entire aerospace community.

Middleton, David B.↗

Television image compression and small animal remote monitoring

It was shown that a subject can reliably discriminate a difference in video image quality (using a specific commercial product) for image compression levels ranging from 384 kbits per second to 1536 kbits per second. However, their discriminations are significantly influenced by whether or not the TV camera is stable or moving and whether or not the animals are quiescent or active, which is correlated with illumination level (daylight versus night illumination, respectively). The highest video rate used here was 1.54 megabits per second, which is about 18 percent of the so-called normal TV resolution of 8.4MHz. Since this video rate was judged to be acceptable by 27 of the 34 subjects (79 percent), for monitoring the general health and status of small animals within their illuminated (lights on) cages (regardless of whether the camera was stable or moved), it suggests that an immediate Space Station Freedom to ground bandwidth reduction of about 80 percent can be tolerated without a significant loss in general monitoring capability. Another general conclusion is that the present methodology appears to be effective in quantifying visual judgments of video image quality.

Haines, Richard F.↗

Real-time earthquake monitoring: Early warning and rapid response

A panel was established to investigate the subject of real-time earthquake monitoring (RTEM) and suggest recommendations on the feasibility of using a real-time earthquake warning system to mitigate earthquake damage in regions of the United States. The findings of the investigation and the related recommendations are described in this report. A brief review of existing real-time seismic systems is presented with particular emphasis given to the current California seismic networks. Specific applications of a real-time monitoring system are discussed along with issues related to system deployment and technical feasibility. In addition, several non-technical considerations are addressed including cost-benefit analysis, public perceptions, safety, and liability.

Source record↗