Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Control-oriented core-SOL-divertor model to address integrated burn and divertor control challenges in ITER

The real-time regulation of a burning plasma’s temperature and density, or burn control, will be necessary to produce high fusion power in future tokamaks like ITER. This is made more challenging due to the plasma’s nonlinear characteristics and the interdependence between the core-plasma and edge-plasma regions. For example, a raising plasma temperature leads to increasing reactivity and therefore to more alpha-particle heating, which further increases temperature. Furthermore, a raise of the fusion power increases the heat flow through the scrape-off-layer (SOL), which can compromise the integrity of the divertor without proper safeguards. For control design, a model-based approach is attractive because it can directly incorporate the nonlinear, coupled, burning-plasma dynamics into the design. To facilitate this design approach, a control-oriented core-SOL-divertor (CSD) model is presented in this work. In this CSD model, a core-plasma model captures the nonlinear dynamics of the core’s density and temperature, and a SOL-divertor model defines the plasma conditions at the separatrix and divertor including the heat load on the target plates. The core-plasma and SOL-divertor models are coupled through the exchange of various variables. In particular, the SOL-divertor model yields the separatrix temperature and the influx of recycled particles into the core-plasma. Further, these variables influence the power and particle balances captured by the core-plasma model. In return, the core-plasma model determines the intensity of the heat and particles fluxes across the separatrix, and this outflow strongly impacts the SOL-divertor model. Therefore, the power and density of the core-plasma, which can be readily modulated through external heating systems and pellet injection, can be viewed as control knobs for the SOL-divertor region in addition to the gas puffing. In simulations of the CSD model, it is demonstrated how external actuation can be utilized to meet burn control and divertor control objectives simultaneously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Models implemented in the methodological approach to design the initial STEP first wall contour

The official Spherical Tokamak for Energy Production mission aims to demonstrate the ability to generate net electricity from fusion with the STEP Prototype Power plant. One of the key technological and engineering challenges in fusion power plants is managing the loads on the first wall within acceptable limits. Therefore, the conceptual design development of the STEP Prototype Power plant needs to be based on load estimates derived using legitimate plasma physics assumptions through dynamic and flexible tools. The current design foresees the STEP main chamber first wall to withstand steady-state heat loads of up to ~1 MW/m 2 , excluding critical regions expected to receive higher heat loads such as the baffle regions approaching the divertors. These critical areas will require ad hoc assessments and will be designed with the presence of limiters. This article focuses on the models and methodology adopted for designing the 2-D poloidal contour of the STEP first wall, based on the anticipated charged particle and radiation heat loads during normal operation. Firstly, the models adopted for calculating the charged particle and radiation heat loads are introduced. The first model is validated through benchmarking against the particle tracing code SMARDDA, while the second model is verified by comparing it with data from the MAST-U experiment. Secondly, the model used to design the 2-D first wall contour according to the heat loads is explained. We acknowledge that this preliminary design stage assumes certain simplifications, notably an axisymmetric geometry, for computational efficiency and clarity in presentation. It is understood that subsequent design phases will address the complexities of real-world engineering, including non-axisymmetric effects, transient plasma scenarios, and the impact of disruptions on the first wall design. Finally, an automatic procedure based on these models is presented for defining the 2-D poloidal contour of the STEP first wall to minimize heat loads, taking into account the need to radiate most of the alpha-particle and auxiliary heating power. Here, by providing an overview of the models, methodology, and an automatic procedure, this paper contributes to the design process of the STEP first wall, addressing the engineering challenges associated with fusion power plant development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

TEAMER: Crossflow Turbine Fairing Geometry Optimization - Report and CFD Modeling Files

The dataset includes computational fluid dynamics (CFD) models and simulation files for crossflow turbines as well as a detailed project report. The report documents the project undertaken by the Ocean Renewable Power Company (ORPC) to design and optimize a modular fairing for the Modular RivGen Marine Hydrokinetic (MHK) turbine, which enhances the efficient deployment and operation of turbine arrays. The project focused on optimizing the hydrodynamic performance of the fairing using CFD, with an emphasis on two key geometric parameters: the fairing's cross-sectional shape and the spacing between the rotor and the fairing. The analysis aimed to maximize net power output while also assessing discretized loading to evaluate ultimate and fatigue loads on the turbine components. The numerical modeling was conducted using both the commercial CFD software Star-CCM+ and the open-source code openFOAM, with the latter utilizing the actuator line library, turbinesFOAM. This dual-code approach was intended to increase confidence in the results and demonstrate the viability of using open-source tools for high-fidelity marine energy modeling. This dataset includes all necessary files for actuator line simulations in openFOAM, as well as 2D blade-resolved CFD results, along with Python and Java scripts for setting up and post-processing simulations.

16 TIDAL AND WAVE POWER↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review—Development of Highly Active and Durable Hybrid Compressive Platinum Lattice Catalysts for Polymer Electrolyte Membrane Fuel Cells: Mathematical Modeling and Experimental Work

This review provides a comprehensive overview on the development of highly active and durable platinum catalysts with ultra-low Pt loadings for polymer electrolyte membrane fuel cells (PEMFCs) through a combined mathematical modeling and experimental work. First, simulation techniques were applied to evaluate the validity of the Tafel approximation for the calculation of the mass activity (MA) and specific activity (SA). A one-dimensional agglomeration model was developed and solved to understand the effects of exchange current density, porosity, agglomerate size, Nafion ® film thickness, and Pt loading on the MA and SA. High porosity (> 60%) and agglomerations at high Pt loadings cause the loss of the Tafel approximation and consequently the decrease in MA and SA. A new structure parameter was introduced to estimate the real porous structure using the fractal theory. The volumetric catalyst density was corrected by the fractal dimension (measured by Hg porosimetry), which gave a good agreement with the experimental values. The loading-dependent Tafel equation was then derived, which contains both the utilization and the non-linear scaling factor. Second, activated carbon composite support (ACCS) with optimized surface area, porosity, pore size, and pore size distribution was developed. The hydrophilic/hydrophobic ratio, structural properties (amorphous/crystalline ratio), and the number of active sites were optimized through metal-catalyzed pyrolysis. Stability of ACCS and Pt/ACCS were evaluated using an accelerated stress test (AST). The results indicated that Pt/ACCS showed no significant loss of MA and power density after 5,000 cycles at 1.0–1.5 V, while the commercial Pt/C catalysts showed drastic losses of MA and power density. Finally, monolayers of compressed Pt (core–shell-type Pt 3 Co 1 ) catalysts were structured by diffusing Co atoms (previously embedded in ACCS) into Pt. Compressive Pt lattice (Pt * ) catalysts were synthesized through an annealing procedure developed at the University of South Carolina (USC). The Pt * /ACCS catalyst showed high initial power density (rated) of 0.174 g Pt kW −1 and high stability (24 mV loss) at 0.8 A cm −2 after 30,000 cycles (0.6–1.0 V). The outstanding performance of Pt * /ACCS is due to the synergistic effect of ACCS and compressive Pt * lattice.

25 ENERGY STORAGE↗

Calibration of cloud and aerosol related parameters for solar irradiance forecasts in WRF-solar

Model parameters are a major source of uncertainty in numerical weather prediction. Recently, the Weather Research and Forecasting model with Solar extensions (WRF-Solar) has been upgraded by enhancing the treatment of sub-grid scale cloud and aerosols with augmentations of a sub-grid scale cloud scheme (CLD3) and an upgraded aerosol-aware Thompson-Eidhammer scheme (TE14). However, the value of model parameters associated with these parameterizations are assigned based on limited measurements or theoretical calculations. Calibrating the most sensitive parameters has the potential to improve solar irradiance predictions. Here, we adopted a multiobjective surrogate-based optimization (SBO) framework to calibrate nine parameters used in CLD3 and TE14 that lead to the largest sensitivity in simulated irradiance. The normalized mean-absolute-error (NMAE) of global horizontal irradiance (GHI) and direct normal irradiance (DNI) are minimized by calibrating WRF-Solar over two regions including the Southern Great Plains (SGP) and Central California, in order to focus on parameter calibration under cloudy conditions with different aerosol loading. The results show that generalized linear model (GLM)-based surrogate models approximate physical models well, particularly when the third order and three-way interaction terms are considered. The SBO framework efficiently searches the parameter space for optimal solutions with less computational costs than directly calibrating the physical model. We first calibrate CLD3 parameters over the less-polluted SGP region. Optimized CLD3 parameters alone result in NMAE reduction by 14% for the site-mean and up to 33% for individual cases over the SGP region. With further calibration of TE14 parameters over the Central California during active fire periods, the optimized parameters lead to over 20% reductions of NMAE. Our investigation reveals, however, that optimizing TE14 has a limited impact on irradiance simulations under less-polluted conditions in the SGP.

14 SOLAR ENERGY↗

ARC disruption physics and strategy

Commonwealth Fusion Systems (CFS) plans to operate a tokamak power plant called ARC in the early 2030s. Tokamak plasmas have stability limits that, if crossed, lead to a rapid termination of the plasma, referred to as a disruption. Disruptions pose a melt risk to the first wall resulting from thermal and non-thermal particle heat fluxes, and an electromagnetic loading risk on all metal components within the equilibrium coils. A comprehensive set of models is used herein to provide an assessment of both mitigated and unmitigated ARC disruption loads. A preliminary massive gas injection system is baselined and a runaway electron mitigation coil option is proposed to close possible gaps in the baseline. It is predicted that all ARC disruption loads are within a factor of 2 of the disruption loads in SPARC, a tokamak presently under construction by CFS, and therefore SPARC provides an opportunity to calibrate models, test solutions and inform the design of ARC. The goal for ARC is disruption-free operation, however, the pragmatic design target is to withstand one mitigated disruption per day, and to restart the plasma following mitigation in tens of seconds without interrupting the power output. Unmitigated disruptions must be rare, and experience with unmitigated disruption impacts in SPARC will better define what rare means. The implications of this strategy for plasma disruptivity and disruption prediction are discussed, and operating the ARC scenario on SPARC is expected to refine the ARC final design and operational plan.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sugar loading is not required for phloem sap flow in maize plants

We report phloem transport of photoassimilates from leaves to non-photosynthetic organs, such as the root and shoot apices and reproductive organs, is crucial to plant growth and yield. For nearly 90 years, evidence has been generally consistent with the theory of a pressure-flow mechanism of phloem transport. Central to this hypothesis is the loading of osmolytes, principally sugars, into the phloem to generate the osmotic pressure that propels bulk flow. Here we used genetic and light manipulations to test whether sugar import into the phloem is required as the driving force for phloem sap flow. Using carbon-11 radiotracer, we show that a maize sucrose transporter1 (sut1) loss-of-function mutant has severely reduced export of carbon from photosynthetic leaves (only ~4% of the wild type level). Yet, the mutant remarkably maintains phloem pressure at ~100% and sap flow speeds at ~50–75% of those of wild type. Potassium (K+) abundance in the phloem was elevated in sut1 mutant leaves. Fluid dynamic modelling supports the conclusion that increased K+ loading compensated for decreased sucrose loading to maintain phloem pressure, and thereby maintained phloem transport via the pressure-flow mechanism. Furthermore, these results suggest that sap flow and transport of other phloem-mobile nutrients and signalling molecules could be regulated independently of sugar loading into the phloem, potentially influencing carbon–nutrient homoeostasis and the distribution of signalling molecules in plants encountering different environmental conditions.

36 MATERIALS SCIENCE↗

Multi-scale experimental study of creep-fatigue failure initiation in a 709 Stainless Steel alloy using high resolution digital image correlation. Final report

This report discusses the efforts made towards the multi-scale study of the creep-fatigue response of stainless steel 709. Multiple experimental techniques, including digital image correlation (DIC) and electron backscatter diffraction (EBSD), were used in assessing the evolution of damage accumulation during fatigue, creep-fatigue, and thermomechanical fatigue of alloy 709. The role of microstructural features, hold times, temperature, and loading profiles were quantified and the interchangeability of temperature and time was investigated. Finally, a thermomechanical fatigue model was shown to predict well the failure of samples with varying loading profiles. Results indicate that strain accumulation in 709 steel happens primarily near grain boundaries (GBs) with the strains around GBs being inversely proportional to their measured residual burgers vector. Furthermore, hot-spots for strain accumulation were shown to be the locations of eventual microcrack nucleation. The introduction of hold times to the periodic loading cycle increases the damage accumulation rate and thus shortens the fatigue life of samples–this was true for both room temperature and high temperature. Thermomechanical cycling was shown to have little effect on the end life of samples, with the damage accumulation rate for in-phase and out-of-phase cycling being similar to isothermal fatigue. The interchangeability of time and temperature was shown to be possible within the studied load, time, and temperature ranges, since deformation mechanisms driving strain accumulation did not change with temperature (up to 650°C). The Neu-Sehitoglu thermomechanical fatigue model, with constants obtained from the literature and in part from our experimental results, was applied to predict failure of isothermal creep-fatigue samples. The main objectives of this work were to:(a) Perform high-resolution digital image correlation measurements (HiDIC) for alloy 709; (b) Quantify and assess damage accumulation at the microstructure under fatigue, TMF, and creep-fatigue conditions of 709; (c) Study of the role of hold times, i.e., adding a creep component, to: Room temperature cycling, High temperature cycling, Failure; (d) Study the mechanisms of thermomechanical fatigue in this alloy; (e) Investigate the existence of a time-temperature interchangeability criterion to aid in accelerated creep-fatigue testing; (f) Establish the validity of a combined creep-fatigue model for life prediction for 709. This report is structured with each subsequent section detailing the efforts, results, and conclusions related to each of the objectives described, mostly in chronological order.

36 MATERIALS SCIENCE↗

Achieving high rate performance in hybrid pristine-recycled cathodes using model-informed electrode designs

Direct recycling lithium-ion battery cathodes, a process that retains the engineered oxide structures from end-of-life materials, presents a cost-effective and energy-efficient alternative to other battery recycling methods. However, while direct-recycled cathodes have demonstrated performance comparable to that of pristine materials at low cycling rates, their high-rate performance remains uncertain. Morphology changes in cathode particles, a main mode of degradation, directly impact rate performance by limiting surface kinetics and solid-phase diffusion. If direct recycling processes do not sufficiently restore pristine-like morphologies, the recycled materials may retain structural defects that hinder high-rate performance. The present work uses a physics-based pseudo-2D model to simulate hybrid electrodes with pristine and artificially “aged/recycled” NMC materials to investigate potential impacts of incorporating performance-limited aged cathode materials into cells. The study highlights how differences in transport and kinetic properties can influence rate capabilities in mixed electrodes — particularly in high-loading cells in high-demand applications. However, model results also reveal a possible mitigation strategy via dual-layer electrode architectures with lower-performing materials positioned near the current collector. Simulations of 4.0 mAh cm −2 cells cycled at 4C using a dual-layer architecture provided approximately 5%–30% more capacity in constant-current protocols compared to homogeneously blended electrode architectures with the same loadings and mixed-material compositions. These findings highlight the importance of strategic electrode design in minimizing potential performance losses and facilitating the integration of recycled materials into high-performance batteries, advancing sustainable and cost-effective battery manufacturing.

25 ENERGY STORAGE↗

Developing Near Optimal Control Sequences for Chiller Plants with Water-side Economizers: A Case Study in a Warm and Marine Climate

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the optimization of those controls is limited. It is possible to maximize energy savings by developing near-optimal control sequences, which are dependent on several factors such as the load profile. To address these gaps, we first identify an advanced control sequence and three key control parameters for chiller plants with WSE. Next, optimizations are performed to minimize energy consumption for seven combinations of control parameters. A chiller plant with WSE system in a warm and marine climate is studied and two load profiles are considered. The system and controls are modeled using the Modelica Buildings library. The results show optimizing the selected control parameters can reduce energy consumption by up to 11% depending on the load profile. Specifically, optimizing the cooling tower efficiency threshold in the condenser water reset control can significantly reduce energy savings for the variable load profile by efficiently shifting the load from the cooling tower to the chiller. This paper provides practical guidance for developing near-optimal control sequences for chiller plant with WSE systems considering impacts such as the load profile.

chiller plant↗

Nanoparticle O–H Bond Dissociation Free Energies from Equilibrium Measurements of Cerium Oxide Colloids

A novel equilibrium strategy for measuring the hydrogen atom affinity of colloidal metal oxide nanoparticles is presented. Reactions between oleate-capped cerium oxide nanoparticle colloids (nanoceria) and organic proton-coupled electron transfer (PCET) reagents are used as a model system. Nanoceria redox changes, or hydrogen loadings, and overall reaction stoichiometries were followed by both 1 H NMR and X-ray absorption near-edge spectroscopies. Furthermore, these investigations revealed that, in many cases, reactions between nanoceria and PCET reagents reach equilibrium states with good mass balance. Each equilibrium state is a direct measure of the bond strength, or bond dissociation free energy (BDFE), between nanoceria and hydrogen. Further studies, including those with larger nanoceria, indicated that the relevant bond is a surface O–H. Thus, we have measured surface O–H BDFEs for nanoceria—the first experimental BDFEs for any nanoscale metal oxide. Remarkably, the measured CeO–H BDFEs span 13 kcal mol –1 (0.56 eV) with changes in the average redox state of the nanoceria colloid. Possible chemical models for this strong dependence are discussed. We propose that the tunability of ceria BDFEs may be important in explaining its effectiveness in catalysis. More generally, metal oxide BDFEs have been used as predictors of catalyst efficacy that, traditionally, have only been accessible by computational methods. These results provide important experimental benchmarks for metal oxide BDFEs and demonstrate that the concepts of molecular bond strength thermochemistry can be applied to nanoscale materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the mechanical behavior of a Nb 3 Sn superconducting coil during a quench: Two-dimensional finite element analysis of a quench heater protected magnet

New high-field accelerator magnets based on $Nb_3Sn$ superconductors are pushing the boundaries of magnet design and quench protection towards new limits. While their large stored energies and current densities result in a very challenging scenario for magnet protection, their great electromagnetic forces create also new requirements in terms of magnet design and stress management techniques. Furthermore, the strain sensitivity of $Nb_3Sn$ cables turns the electro-mechanical limits of the conductor into a parameter of the highest importance, where conductor degradation becomes a critical aspect in magnet operation. The coupling of all the above-mentioned considerations during quench is a case of special interest that adds further complexity to the design of $Nb_3Sn$ magnets. The objective of this paper is to provide a complete two-dimensional investigation of the coil and magnet structure mechanics during a quench event. Here, the analysis is performed using a combination of finite element codes that provide the necessary input for the mechanical study. The core of the modelling strategy relies on a thermal-electric model, whose results are directly used as loads in the mechanical simulation. In doing so, the stress evolution during and after a quench is obtained. We focus for this time in the analysis of a quench heater protected magnet, where dynamic effects are of less importance in contrast to other protection systems like CLIQ.

43 PARTICLE ACCELERATORS↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

A comparative study on deep learning models for condition monitoring of advanced reactor piping systems

Advanced nuclear reactors offer innovative applications due to their portability, reliability, resiliency, and high capacity factors. To operate them on a wider scale, reducing maintenance life-cycle costs while ensuring their integrity is essential. Autonomous operations in advanced nuclear reactors using augmented Digital Twin (DT) technology can serve as a cost-effective solution by increasing awareness about the system’s health. A key component of nuclear DT frameworks is the condition monitoring of safety systems, such as piping-equipment systems, which involves acquiring and monitoring the plant’s sensor data. Here, this research proposes a condition monitoring methodology utilizing deep learning algorithms, such as multilayer perceptions (MLP) and convolutional neural networks (CNNs), to detect degradation and its severity in nuclear piping-equipment systems. Sensor signals are processed to obtain the power spectral density and the Short-Time Fourier transform, and feature extraction methodologies are proposed to develop degradation-sensitive data repositories. The performance of MLP, one-dimensional (1D) CNN, and 2D CNN within the proposed condition monitoring framework is compared using a finite element model of a 3D piping system subjected to seismic loads as the application case study. Various approaches, such as dropout, k-Fold validation, regularization, and early stopping of training the network, are investigated to avoid overfitting the models to the input sensor data. The predictive capability and computational capacity of the deep learning algorithms are also compared to detect degradation in the Z-pipe system of the Experimental Breeder Reactor II (EBRII). The Z-pipe system is subjected to harmonic excitations that represent normal operating loads, such as pump-induced vibrations. The findings of the study indicate that the proposed artificial intelligence (AI)-driven condition monitoring framework demonstrates superior prediction accuracies with a 2D CNN, whereas the MLP exhibits higher computational efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗