A prototype quantitative film scanner for radiochromic film dosimetry

We have developed a high resolution, quantitative, two-dimensional optical film scanner for use with a commercial high sensitivity radiochromic film (RCF) for measuring single fraction external-beam radiotherapy dose distributions. The film scanner was designed to eliminate artifacts commonly observed in RCF dosimetry. The scanner employed a stationary light source and detector with a moving antireflective glass film platen attached to a high precision computerized X-Y translation stage. An ultrabright red light emitting diode (LED) with a peak output at 633 nm and full width at half maximum (FWHM) of 16 nm was selected as the scanner light source to match the RCF absorption peak. A dual detector system was created using two silicon photodiode detectors to simultaneously measure incident and transmitted light. The LED light output was focused to a submillimeter (FWHM 0.67 mm) spot size, which was determined from a scanning knife-edge technique for measuring Gaussian optical beams. Data acquisition was performed with a 16-bit A/D card in conjunction with commercial software. The linearity of the measured densities on the scanner was tested using a calibrated neutral-density step filter. Sensitometric curves and three IMRT field scans were acquired with a spatial resolution of 1 mm for both radiographic film and RCF. The results were compared with measurements taken with a commercial diode array under identical delivery conditions. The RCF was rotated by 90 deg. and rescanned to study orientation effects. Comparison between the RCF and the diode array measurements using percent dose difference and distance-to-agreement criteria produced average passing rates of 99.0% using 3%/3 mm criteria and 96.7% using 2%/2 mm criteria. The same comparison between the radiographic film and diode array measurements resulted in average passing rates 96.6% and 91.6% for the above two criteria, respectively. No measurable light-scatter or interference scanner artifacts were observed. The RCF rotated by 90 deg. showed no measurable orientation effect. A scan of a 15x15 cm{sup 2} area with 1 mm resolution required 22 min to acquire. The LED densitometer provides an accurate film dosimetry system with 1 mm or better resolution. The scanner eliminates the orientation dependence of RCF dosimetry that was previously reported with commercial flatbed scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Workshop on Biological Science Opportunities Provided by the APS Upgrade

Synchrotron-based macromolecular X-ray crystallography (MX) is the primary method for determining the structure of biological molecules including proteins, nucleic acids, complexes, and large assemblies at high resolution (e.g., 95% of all new Protein Data Bank [PDB] deposits in 2017). The Advanced Photon Source (APS), which is the largest and the most productive light source for MX, will be upgraded to a multi-bend achromat lattice (the Advanced Photon Source Upgrade — APS-U) that will deliver the ultimate diffraction-limited X-ray source with radically transformative MX capabilities. The specific advantages of the APS-U X-ray source include (1) increased brightness allowing delivery of intense beams with dimensions of 1-μm or less, resulting in a 100-fold improvement in signal-to-noise, (2) increased brightness at high energy (especially for energies of 12 keV-40 keV commonly used in MX) that can be exploited to reduce primary radiation damage, and (3) low-convergence X-ray beams that will be essential for the study of large macromolecular complexes at high resolution. A workshop on “Biological Science Opportunities Provided by the APS Upgrade” was organized at Argonne National Laboratory on August 18-20, 2018, to discuss the biological science opportunities offered by the unique new capabilities of the APS-U and how the broad structural biology community could best exploit them. The APS-U takes place in a context where advances in X-ray free-electron laser (XFEL) sources and cryo-electron microscopy (cryo-EM) have added to the constellation of techniques and propelled structural biology in new directions. Synergies exist between these different technologies and it is essential to develop enabling technologies that exploit the unique, world-leading, and synergistic characteristics of each light source to boost capabilities for producing leading-edge biological research for U.S. Department of Energy (DOE) missions in energy and environment, and National Institutes of Health (NIH) missions in human health.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinoform optics applied to X-ray photon correlation specroscopy

Moderate-demagnification higher-order silicon kinoform focusing lenses have been fabricated to facilitate small-angle X-ray photon correlation spectroscopy (XPCS) experiments. The geometric properties of such lenses, their focusing performance and their applicability for XPCS measurements are described. It is concluded that one-dimensional vertical X-ray focusing via silicon kinoform lenses significantly increases the usable coherent flux from third-generation storage-ring light sources for small-angle XPCS experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RF CONTROL OF HIGH QL SUPERCONDUCTING CAVITIES

In the last 20 years the requirements for RF Control have increased as the target use has broadened from electron/ion accelerators for Nuclear and Particle Physics to light sources such as Free Electron Lasers. The increasing requirement of cavity field control to meet the spectral and jitter performance specifications for light sources has led system designers to a more rigorous approach in designing the RF controls. Design attention must be applied not only to the hardware and control algorithms but also to the overall accelerating system to meet performance and cost requirements. As an example, cavity QL in Energy Recovery Linacs (ERL) must be optimized such that the RF controls can accommodate the lowest possible RF power given the background cavity microphonics. This paper presents the status and future directions of high QL superconducting RF control systems.

43 PARTICLE ACCELERATORS↗

Calculations of synchrotron radiation emission in the transverse coherent limit

We present approximations for the synchrotron radiation emission for low emittance light sources, which provide a connection between user needs and the electron beam parameters. The results and calculations are a consequence of the phase coherence in the emission from the electrons. We derive the remarkable result that if the electron beam is energetic enough, the emitted flux is independent of the photon energy, electron beam energy, or bending radius in the transverse coherent limit. Similarly the brightness is identical for all machines at a given current.

43 PARTICLE ACCELERATORS↗

A theory of photometric stereo for a class of diffuse non-Lambertian surfaces

A theory of photometric stereo is proposed for a large class of non-Lambertian reflectance maps. The authors review the different reflectance maps proposed in the literature for modeling reflection from real-world surfaces. From this, they obtain a mathematical class of reflectance maps to which the maps belong. They show that three lights can be sufficient for a unique inversion of the photometric stereo equation for the entire class of reflectance maps. They also obtain a constraint on the positions of light sources for obtaining this solution. They investigate the sufficiency of three light sources to estimate the surface normal and the illuminant strength. The issue of completeness of reconstruction is addressed. They shown that if k lights are sufficient for a unique inversion, 2k lights are necessary for a complete inversion.

Tagare, Hemant D.↗

Ultraintense X-Ray Induced Ionization, Dissociation, and Frustrated Absorption in Molecular Nitrogen

Sequential multiple photoionization of the prototypical molecule N{sub 2} is studied with femtosecond time resolution using the Linac Coherent Light Source (LCLS). A detailed picture of intense x-ray induced ionization and dissociation dynamics is revealed, including a molecular mechanism of frustrated absorption that suppresses the formation of high charge states at short pulse durations. The inverse scaling of the average target charge state with x-ray peak brightness has possible implications for single-pulse imaging applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Two Dimensional Integration of Ring Cavity Surface Emitting Quantum Cascade Lasers

The continual improvements over the last fifteen years have made quantum cascade lasers reliable and versatile light sources in the mid infrared and the terahertz spectral regions. In this work we present our latest results regarding the implementation of these light sources for forming broad band emitting two-dimensional laser arrays. A spectral tuning range of 180 cm{sup -1} around the centered wavelength of 8.2 {mu}m could be shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-microradian Surface Slope Metrology with the ALS Developmental Long Trace Profiler

Development of X-ray optics for 3rd and 4th generation X-ray light sources with a level of surface slope precision of 0.1-0.2 {micro}rad requires the development of adequate fabrication technologies and dedicated metrology instrumentation and methods. Currently, the best performance of surface slope measurement has been achieved with the NOM (Nanometer Optical Component Measuring Machine) slope profiler at BESSY (Germany) [1] and the ESAD (Extended Shear Angle Difference) profiler at the PTB (Germany) [2]. Both instruments are based on electronic autocollimators (AC) precisely calibrated for the specific application [3] with small apertures of 2.5-5 mm in diameter. In the present work, we describe the design, initial alignment and calibration procedures, the instrumental control and data acquisition system, as well as the measurement performance of the Developmental Long Trace Profiler (DLTP) slope measuring instrument recently brought into operation at the Advanced Light Source (ALS) Optical Metrology Laboratory (OML). Similar to the NOM and ESAD, the DLTP is based on a precisely calibrated autocollimator. However, this is a reasonably low budget instrument used at the ALS OML for the development and testing of new measuring techniques and methods. Some of the developed methods have been implemented into the ALS LTP-II (slope measuring long trace profiler [4]) which was recently upgraded and has demonstrated a capability for 0.25 {micro}rad surface metrology [5]. Performance of the DLTP was verified via a number of measurements with high quality reference mirrors. A comparison with the corresponding results obtained with the world's best slope measuring instrument, the BESSY NOM, proves the accuracy of the DLTP measurements on the level of 0.1-0.2 {micro}rad depending on the curvature of a surface under test. The directions of future work to develop a surface slope measuring profiler with nano-radian performance are also discussed.

47 OTHER INSTRUMENTATION↗

Facility Designed and Built to Investigate the Combined Effects of Contaminant and Atomic Oxygen on a Light-Transmitting Surface

A need exists to investigate changes in the transparency of a light-transmitting surface during simultaneous exposure to a contaminant and an atomic oxygen (AO) flux. This mechanism may be responsible for the degradation of the light-transmitting surfaces of both photovoltaic cells and photodiodes currently in use on many low-Earth-orbit spacecraft. To address this need, researchers from the Electro-Physics Branch of the NASA Glenn Research Center at Lewis Field built such a test system within their AO beam facility. This facility produces an effective AO flux of 1.4 10(exp 16) atoms/sq cm/sec and contains a three-axis positioning system that provides the motion capability necessary for test operations. During testing, a target surface is held directly within the AO beam and close to two contaminant effusion cells. The effusion cells are shielded from the AO beam, and the outgassing contaminant is constrained to move across the target surface when heat is applied to either of the reservoirs. A light source is periodically moved over the target surface, and the transmitted light intensity is checked with a photodiode located below the target. This light source is also periodically checked with a separate photodiode, which is protected from contamination and AO exposure, to allow adjustments necessary to maintain a consistent light intensity.

Sechkar, Edward A.↗

Evaluation of expanded uncertainties in luminous intensity and illuminance calibrations

Detector-based calibrating methods and expressions for calculation of photometric uncertainties related to uncertainties in the calibrations of luminous intensity of a light source, illuminance responsivity of a photometer head, and calibration factors of an illuminance meter are discussed. These methods permit luminous intensity calibrations of incandescent light sources, luminous responsivity calibrations of photometer heads, and calibration factors of illuminance meters to be carried out with relative expanded uncertainties (with a level of confidence of 95.45%) of 0.4%, 0.4%, and 0.6%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam dynamics simulations of the transverse-to-longitudinal emittance exchange proof-of-principle experiment at the Argonne Wakefield Accelerator

Transverse-to-longitudinal emittance exchange has promising applications in various advanced acceleration and light source concepts. A proof-of-principle experiment to demonstrate this phase space manipulation method is currently being planned at the Argonne Wakefield Accelerator. The experiment focuses on exchanging a low longitudinal emittance with a high transverse horizontal emittance and also incorporates room for possible parametric studies e.g. using an incoming flat beam with tunable horizontal emittance. In this paper, we present realistic start-to-end beam dynamics simulation of the scheme, explore the limitations of this phase space exchange.

43 PARTICLE ACCELERATORS↗

Demonstration of Complete Recycling Processes of Reversible Epoxies Using Solar Energy Conversion

Reversible epoxies using the Diels–Alder chemistry enables recycling processes through depolymerizing the polymer at higher temperature and then repolymerizing upon cooling. Compared to conventional bulk heating, photothermal heating can save time and resource and, consequently, reduce costs to reach an elevated temperature for recycling processes of the reversible epoxies. In previous studies, self‐healing of cracks and reattachments of two broken pieces have been presented using a laser; however, recycling of a sample as a whole is not feasible by using such a point light source. Herein, complete recycling processes are demonstrated utilizing an area light source, i.e., sunlight. Reversible epoxies are incorporated with carbon black and refractory plasmonic titanium nitride nanoparticles (NPs). Under concentrated (10 times) sunlight, they can generate sufficient heat (≈140 °C) to completely liquefy, reprocess, and reshape the samples multiple times. Recycling processes are validated by evaluation of mechanical properties for each cycle. Using an integrated experimental and theoretical approach, photothermal performance is investigated in terms of the dispersion and loading of photothermal NPs in the matrix, as well as the sample thickness. In this study, an insight is provided into the design of polymer/photothermal nanomaterial composites which can be sustainably recycled using abundant solar energy.

14 SOLAR ENERGY↗

Fast dynamic aperture optimization with forward-reversal integration

A fast dynamic aperture (DA) optimization method for storage rings has been developed through the use of reversal integration. Even if dynamical systems have an exact reversal symmetry, a numerical forward integration differs from its reversal. For a chaotic trajectory, cumulative round-off errors are scaled, which results in an exponential growth on the difference. The exponential effect is a generic chaos indicator which represents the sensitivity of the chaotic motion to its initial condition. The chaos indicator of the charged particle motion can be obtained by comparing the forward integrations of particle trajectories with corresponding reversals, a.k.a. “backward integrations.” The indicator is observable even through short-term particle tracking simulations. Therefore, adopting it as an objective function could speed up optimization. Finally, the DA of the National Synchrotron Light Source II storage ring, and another test diffraction-limited light source ring, were optimized using this method for the purpose of demonstration.

43 PARTICLE ACCELERATORS↗

Evaluation of an LED Simulator for Single- and Multi-Junction PV Cell Performance Testing

We present the evaluation of a solar simulator comprising a Light Emitting Diode (LED) array as its light source. While multiple applications can be envisioned for such a light source, here we focus on its use for performance testing of solar cells at Standard Test Conditions. With this in mind, we present characterization of the spatial uniformity of the irradiance and its temporal stability as well as the spectral range and spectral class. For a multisource simulator, the spectral uniformity across the test plane should also be evaluated and we discuss a method for performing this evaluation that is well suited to a solar cell performance testing application. One major advantage of this simulator is the ability to easily adjust the spectral output as needed in multijunction PV cell measurements and we also discuss this application here.

LED↗

NSLS-II Booster Survey and Alignment Systems

This section outlines the survey and alignment requirements and the technology and tools for achieving the NSLS-II equipment positioning goals. The required alignment tolerances are defined primarily by the physics requirements of the accelerator. The tight tolerances dictated by the physics requirements are an order of magnitude tighter than the tolerances of second generation light sources (NSLS) and on level with those at third generation light sources (Soleil, Diamond). These extraordinary position requirements necessitate a concerted R&D engineering effort to identify and develop the survey methodology needed to meet these requirements. As of this date, the methodology is still evolving to balance cost and time constraints while still maintaining the integrity of the survey and alignment systems. State-of-the art equipment including Laser Trackers and Laser Arms have been purchased and used extensively in the pursuit of meeting the NSLS-II survey tolerances. No new technology will need to be developed to meet the alignment requirements but new techniques will be pursued and developed. Survey and alignment provides the foundation for positioning the beam-guiding magnet structures in all 6 degrees of freedom within the required tolerances. Although the tools and instrumentation available for this task have changed over the years and faster and more accurate measurements are possible, only limited control of the environmental conditions is possible. This ultimately sets an upper limit for the achievable measurement and subsequent control network accuracy. At the same time, the control of environmental variables (temperature, humidity) will be fully taken advantage of during the building of NSLS-II , opening up the possibility of ever-increasing accuracy unheard of only five years ago.

42 ENGINEERING↗

NSLS-II Booster Survey and Alignment Systems

This section outlines the survey and alignment requirements and the technology and tools for achieving the NSLS-II equipment positioning goals. The required alignment tolerances are defined primarily by the physics requirements of the accelerator. The tight tolerances dictated by the physics requirements are an order of magnitude tighter than the tolerances of second generation light sources (NSLS) and on level with those at third generation light sources (Soleil, Diamond). These extraordinary position requirements necessitate a concerted R&D engineering effort to identify and develop the survey methodology needed to meet these requirements. As of this date, the methodology is still evolving to balance cost and time constraints while still maintaining the integrity of the survey and alignment systems. State-of-the art equipment including Laser Trackers and Laser Arms have been purchased and used extensively in the pursuit of meeting the NSLS-II survey tolerances. No new technology will need to be developed to meet the alignment requirements but new techniques will be pursued and developed.

36 MATERIALS SCIENCE↗

System and method that suppresses intensity fluctuations for free space high-speed optical communication

A high-speed (Gbps), free space optical communication system is based on spectral encoding of radiation from a wide band light source, such as a laser. By using partially coherent laser beams in combination with a relatively slow photosensor, scintillations can be suppressed by orders of magnitude for distances of more than 10 km. To suppress the intensity fluctuations due to atmospheric turbulence, a source with partial transverse coherence in combination with slow response time photodetector is used. Information is encoded in the spectral domain of a wideband optical source by modulation of spectral amplitudes. A non-coherent light source with wide spectrum (an LED, for example) may be used for high-speed communication over short (less than about a mile) distances.

47 OTHER INSTRUMENTATION↗