Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

9 Li($\textit{d,p}$) reaction as a specific probe of 10 Li, the paradigm of parity-inverted nuclei around the $\textit{N}$ = 6 closed shell

In this work, we show, within the framework of renormalized nuclear field theory and of the induced reaction surrogate formalism, that the highly debated 10 Li structure, studied in a recent high statistics 9 Li ($\textit{d,p}$) 10 Li one-neutron transfer experiment, is consistent with, or better, requires, the presence of a virtual 1/2 + state of similar single-particle strength than that of the 1/2 – resonance at 0.45 ± 0.03 MeV. Based on continuum spectroscopy self-energy techniques, we find that the physical mechanism responsible for parity inversion in $^{10}_3$Li is the same as that at the basis of the similar phenomenon observed in $^{11}_4$Be and as that needed in 11 Li to have an important $\textit{s}$-wave ground-state component. In particular the strong dynamical coupling between the $s_{1/2}$ and the $d_{5/2}$ states, mediated by the quadrupole vibration of the core 9 Li. A phenomenon which also affects the strength distribution of the $d_{5/2}$ state, in particular, in the energy range of 3–4.5 MeV. Furthermore, this mechanism is also consistent with the (normal) sequence of the $1_{p_{1/2}}$ and $2_{s_{1/2}}$ levels in the $\textit{N}$ = 7 isotones $^{12}_5$B and $^{13}_6$C. The main aim of the present Rapid Communication is that of treating structure and reactions on equal footing and in a common language. In other words, the calculation of the 9 Li ($\textit{d,p}$) 10 Li reaction as a single conceptual step from individual single-particle motion and collective vibrations to absolute double differential cross sections of renormalized virtual and resonant final states, which can be directly compared with experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An invertible seven-dimensional Dirichlet cell characterization of lattices

Characterization of crystallographic lattices is an important tool in structure solution, crystallographic database searches and clustering of diffraction images in serial crystallography. Characterization of lattices by Niggli-reduced cells (based on the three shortest non-coplanar lattice vectors) or by Delaunay-reduced cells (based on four non-coplanar vectors summing to zero and all meeting at obtuse or right angles) is commonly performed. The Niggli cell derives from Minkowski reduction. The Delaunay cell derives from Selling reduction. All are related to the Wigner–Seitz (or Dirichlet, or Voronoi) cell of the lattice, which consists of the points at least as close to a chosen lattice point as they are to any other lattice point. The three non-coplanar lattice vectors chosen are here called the Niggli-reduced cell edges. Starting from a Niggli-reduced cell, the Dirichlet cell is characterized by the planes determined by 13 lattice half-edges: the midpoints of the three Niggli cell edges, the six Niggli cell face-diagonals and the four body-diagonals, but seven of the lengths are sufficient: three edge lengths, the three shorter of each pair of face-diagonal lengths, and the shortest body-diagonal length. These seven are sufficient to recover the Niggli-reduced cell.

Chemistry↗

Farm-level Interactions Study of a Novel Tri-port Soft-switching Medium-Voltage String Inverter (MVSI) based Large-scale PV-Plus-Storage Farms

A medium-voltage photovoltaic power conversion unit supported by battery based on a novel topology of soft switching solid state transformer is presented in this paper. It can reduce the Levelized Cost of Energy (LCOE) of PVS farm in an extended degree. However, its capability to provide grid-support services, such as frequency response, reactive power support, etc, have not been demonstrated. A series/parallel combination of these modules form a large 20 MVA solar farm. To validate them with reduced computation burden, a small-signal model of MVSI is firstly derived and validated in this paper. The model has been validated to match the full-switch model in both steady-state and dynamic conditions. Next, a farm-level simulation based on the proved small-signal model was implemented to demonstrate grid-support services. Real irradiation date from NREL is used to show the operational capabilities of the system. As a result, the overall farm is simulated based on MATLAB/Simulink domain to check the performance for various cases namely: power transfer from dc-ac side, reactive power support during grid voltage sag and utilization of battery during grid voltage disturbance or partial shading over PV panels.

14 SOLAR ENERGY↗

Experimental Results for an Inverter Integrated with A High-Speed Surface Permanent Magnet External Rotor Motor

This work presents the prototyping and testing of a high-speed outer rotor surface permanent magnet motor. The motor employs non-heavy rare-earth permanent magnets and operates at a rated speed of 6,666 rpm. In-slot ceramic heat exchangers are used to cool the windings. The external rotor configuration provides substantial space within the stator bore, which is used for power electronics integration. This integration introduces several design and thermal management challenges that are discussed in the paper. The machine has been prototyped and tested under various operating conditions, and both simulation and experimental results are presented.

Rallabandi, Vandana [ORNL] (ORCID:0000000236241901↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

Electric Power Industry Challenges Due to Increasing Shares of Inverter-Based Resources in Power Systems

The large-scale integration of variable renewable energy technologies around the world is forcing electric power systems into an unprecedented transition. This paper reports on power grid modernization and reliability issues related to the planning and operation of power systems with high levels of variable renewable energy. The contents of this paper stem from recent qualitative research in the form of a summary of an industry survey. The technical feedback from the interviewed 37 industry experts helped us identify 12 key areas of potential concern, which are discussed throughout this paper.

power system operation↗