Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Internal Charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

International Space Station Nickel-Hydrogen Battery On-Orbit Performance

International Space Station (ISS) Electric Power System (EPS) utilizes Nickel-Hydrogen (Ni-H2) batteries as part of its power system to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The batteries are designed to operate at a 35 percent depth of discharge (DOD) maximum during normal operation. Thirty-eight individual pressure vessel (IPV) Ni-H2 battery cells are series-connected and packaged in an Orbital Replacement Unit (ORU). Two ORUs are series-connected utilizing a total of 76 cells to form one battery. The ISS is the first application for low earth orbit (LEO) cycling of this quantity of series-connected cells. The P6 (Port) Integrated Equipment Assembly (IEA) containing the initial ISS high-power components was successfully launched on November 30, 2000. The IEA contains 12 Battery Subassembly ORUs (6 batteries) that provide station power during eclipse periods. This paper will discuss the battery performance data after eighteen months of cycling.

Dalton, Penni↗

Update on International Space Station Nickel-Hydrogen Battery On-Orbit Performance

International Space Station (ISS) Electric Power System (EPS) utilizes Nickel-Hydrogen (Ni-H2) batteries as part of its power system to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The batteries are designed to operate at a 35% depth of discharge (DOD) maximum during normal operation. Thirty-eight individual pressure vessel (IPV) Ni-H2 battery cells are series-connected and packaged in an Orbital Replacement Unit (ORU). Two ORUs are series-connected utilizing a total of 76 cells, to form one battery. The ISS is the first application for low earth orbit (LEO) cycling of this quantity of series-connected cells. The P6 (Port) Integrated Equipment Assembly (IEA) containing the initial ISS high-power components was successfully launched on November 30, 2000. The IEA contains 12 Battery Subassembly ORUs (6 batteries) that provide station power during eclipse periods. This paper will discuss the battery performance data after two and a half years of cycling.

Dalton, Penni↗

Neutron Environment Calculations for Low Earth Orbit

The long term exposure of astronauts on the developing International Space Station (ISS) requires an accurate knowledge of the internal exposure environment for human risk assessment and other onboard processes. The natural environment is moderated by the solar wind, which varies over the solar cycle. The HZETRN high charge and energy transport code developed at NASA Langley Research Center can be used to evaluate the neutron environment on ISS. A time dependent model for the ambient environment in low earth orbit is used. This model includes GCR radiation moderated by the Earth's magnetic field, trapped protons, and a recently completed model of the albedo neutron environment formed through the interaction of galactic cosmic rays with the Earth's atmosphere. Using this code, the neutron environments for space shuttle missions were calculated and comparisons were made to measurements by the Johnson Space Center with onboard detectors. The models discussed herein are being developed to evaluate the natural and induced environment data for the Intelligence Synthesis Environment Project and eventual use in spacecraft optimization.

Clowdsley, M. S.↗

Analytical Ion Thruster Discharge Performance Model

A particle and energy balance model of the plasma discharge in magnetic ring-cusp ion thrusters has been developed. The model follows the original work of Brophy in the development of global 0-D discharge models that utilize conservation of particles into and out of the thruster and conservation of energy into the discharge and out of the plasma in the form of charged particles to the walls and beam and plasma radiation. The present model is significantly expanded over Brophy's original work by including self-consistent calculations of the internal neutral pressure, electron temperature, primary electron density, electrostatic ion confinement (due to the ring-cusp fields), plasma potential, discharge stability, and time dependent behavior during recycling. The model only requires information on the thruster geometry, ion optics performance and electrical inputs such as discharge voltage and currents, etc. to produce accurate performance curves of discharge loss versus mass utilization efficiency. The model has been benchmarked against the NEXIS Laboratory Model (LM) and Development Model (DM) thrusters, and successfully predicts the thruster discharge loss as a function of mass utilization efficiency for a variety of thrusters. The discharge performance model will be presented and results showing ion thruster performance and stability given.

discharge chambers↗

Electrodynamic Dust Shield Technology for Thermal Radiators Used in Lunar Exploration

Two general types of thermal radiators are being considered for lunar missions: coated metallic surfaces and Second Surface Mirrors. Metallic surfaces are coated with a specially formulated white paint that withstands the space environment and adheres well to aluminium, the most common metal used in space hardware. AZ-93 White Thermal Control Paint, developed for the space program, is an electrically conductive inorganic coating that offers thermal control for spacecraft. It is currently in use on satellite surfaces (Fig 1). This paint withstands exposure to atomic oxygen, charged particle radiation, and vacuum ultraviolet radiation form 118 nm to 170 nm while reflecting 84 to 85% of the incident solar radiation and emitting 89-93% of the internal heat generated inside the spacecraft.

Calle, Carlos I.↗

Piezoelectric Charging and Wireless Communication

Modern medicine is undergoing a revolution in the application of new sensor capabilities for aiding in diagnosis of specific conditions and monitoring a variety of informative vital signs. In the past, many of the measurements were limited by what could be accomplished externally. A shift toward in-vivo monitoring for both diagnostic and therapeutic sensing and actuation [1] has created a need for low power electronics, high energy density batteries and methods to successfully power devices embedded in the body. For a review of the field and sensing capabilities see [2]. Recent studies suggest that charging with ultrasound is more efficient at longer transmission distance (> 10cm) than inductive charging [3]. In this manuscript, we discuss the modeling and experimentation that we have accomplished and demonstrate in ultrasonic charging of sensors having the form and fit of in-vivo sensors. The task goal has been to use piezoelectric transducers for wireless communication and powering of sensors internal to the human body with a goal to transmit power levels of 100 W a receiver with receiving area of 3x3 mm2 over a distance of 16 cm equivalent to human body interior. The results suggest that we can transmit power levels that exceed this baseline requirement.

Jackson, Shannon↗

The Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Pre-Flight Planning

The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services (CLPS) initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University (OU), NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of an ESA-provided Exospheric Mass Spectrometer (EMS; including sensor, electronics, controller, power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in a radiofrequency field, then sequentially released to a detector to build a mass spectrum. PITMS was capable of measuring species with a massto-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.

Barbara Cohen↗

Charge density waves on a half-filled decorated honeycomb lattice

Tight binding models like the Hubbard Hamiltonian are most often explored in the context of uniform intersite hopping $\textit{t}$. The electron-electron interactions, if sufficiently large compared to this translationally invariant $\textit{t}$, can give rise to ordered magnetic phases and Mott insulator transitions, especially at commensurate filling. The more complex situation of nonuniform $\textit{t}$ has been studied within a number of situations, perhaps most prominently in multiband geometries where there is a natural distinction of hopping between orbitals of different degree of overlap. In this paper we explore related questions arising from the interplay of multiple kinetic energy scales and electron-phonon interactions. Specifically, we use determinant quantum Monte Carlo (DQMC) to solve the half-filled Holstein Hamiltonian on a “decorated honeycomb lattice,” consisting of hexagons with internal hopping $\textit{t}$ coupled together by $\textit{t'}$. This modulation of the hopping introduces a gap in the Dirac spectrum and affects the nature of the topological phases. Here, we determine the range of $\textit{t/t'}$ values which support a charge density wave phase about the Dirac point of uniform hopping $\textit{t = t'}$, as well as the critical transition temperature $T_c$. The QMC simulations are compared with the results of mean field theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

International Space Station Lithium-Ion Battery Status

When originally launched, the International Space Station (ISS) primary Electric Power System (EPS) used Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate for ten years at a 35 percent depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. For service beyond that period, upgraded Li-Ion Orbital Replacement Units (ORUs) were designed. These are the largest Li-Ion batteries ever utilized for a human rated spacecraft. With the oldest 12 Ni-H2 battery ORUs cycling since September 2006, the first set of six was replaced by Li-Ion batteries in December 2016; the second set of six is planned for replacement in September 2018. This paper will include an overview of the ISS Li-Ion battery system architecture, on-orbit status of the first 6 batteries, start up of the second 6 batteries, and the status of the Li-Ion cell and ORU life cycle testing.

International Space Station↗

Heat generation in electric double layer capacitors with neat and diluted ionic liquid electrolytes under large potential window between 5 and 80 °C

Here, this study investigates the effect of temperature on the heat generation and the associated electrochemical phenomena occurring in IL-based EDLCs. The EDLCs consisted of two identical activated carbon electrodes with neat Pyr14TFSI or Pyr14TFSI diluted in propylene carbonate (PC) as electrolytes. The instantaneous heat generation rate at each electrode was measured by isothermal calorimetry between 5 and 80 °C under constant current cycling and potential window of 2.5 V. First, the instantaneous heat generation rate was similar at each electrode in neat IL. However, it was smaller at the negative electrode in diluted IL and featured endothermic dips growing with increasing temperature > 40 °C due to overscreening effects, ion desolvation, and/or decomposition of PC. The irreversible heat generation was similar in each half-cell and decreased with increasing temperature due to the reduction in internal resistance, particularly with neat IL. The irreversible heat generation exceeded Joule heating in all cases, especially at high temperature and low current. This was attributed to ion desorption and charge redistribution in the porous electrodes. Finally, the reversible heat generation for both electrolytes was larger at the positive than at the negative electrode due to the difference in anion and cation sizes.

25 ENERGY STORAGE↗

Dynamics of Charge Transfer and Multiple Exciton Generation in the Doped Silicon Quantum Dot–Carbon Nanotube System: Density Functional Theory-Based Computation

In this study, we use the Boltzmann transport equation (BE) to study time evolution of a photoexcited state, including phonon-mediated exciton relaxation, multiple exciton generation (MEG), and energy-transfer processes. BE collision integrals are derived using Kadanoff–Baym–Keldysh many-body perturbation theory (MBPT) based on density functional theory (DFT) simulations, including exciton effects. We apply the method to a nanostructured p–n junction composed of a 1 nm hydrogen-terminated Si quantum dot (QD) doped with two phosphorus atoms (Si 36 P 2 H 42 ) adjacent to the (6, 2) single-wall carbon nanotube (CNT) with two chlorine atoms per two unit cells adsorbed to the surface. We find that an initial excitation localized on either the QD or CNT evolves into a transient charge-transfer (CT) state where either electron or hole transfer has taken place. The CT state lifetime is about 40 fs. Also, we study MEG in this system by computing internal quantum efficiency (QE), which is the number of excitons generated from an absorbed photon during relaxation. We predict efficient MEG starting at 3E g ≃ 1.5 eV and with QE reaching QE = 1.65 at about 5E g , where E g ≃ 0.5 eV is the lowest exciton energy, i.e., the gap. However, we find that including energy transfer and MEG effects suppresses CT state generation.

36 MATERIALS SCIENCE↗

Enhancing exciton diffusion by reducing energy disorder in organic solar cells

A highly crystalline, highly emissive, and wide-bandgap polymer AC174 with an extremely small Stokes shift is designed and synthesized in water, and is used to reduce system energetic disorder and increase the exciton diffusion length of the classical PM6:Y6 blend system. AC174 is incompatible with PM6 and Y6, improves molecular packing, and reduces system energetic disorder. The long-range Förster resonance energy transfer between the donor and acceptor is enhanced, and the exciton diffusion constant and exciton lifetime are increased, leading to a longer exciton diffusion length and more efficient exciton dissociation and charge generation. The addition of AC174 simultaneously improves the open-circuit voltage, short-circuit current density (J SC ) and fill factor of PM6:Y6 devices; especially the highest internal quantum efficiency approaches 100%, and the highest J SC is 28.4 mA cm –2 . Ternary devices with 5% AC174 in the donors achieve a power conversion efficiency of 17.2%, higher than those of the parent binary devices based on PM6:Y6 (15.9%) and AC174:Y6 (3.24%).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic and magnetodielectric properties of erbium iron garnet ceramic

An Er{sub 3}Fe{sub 5}O{sub 12} ceramic has been sintered in oxygen atmosphere at 1400 Degree-Sign C for dielectric measurements. Its structural quality at room temperature has been checked by combining transmission electron microscopy and X-ray diffraction. It crystallizes in the cubic space group Ia3d with a = 12.3488(1). The dielectric permittivity ({epsilon} Prime ) and losses (tan {delta}) measurements as a function of temperature reveal the existence of two anomalies, a broad one between 110 K and 80 K, attributed to the Er{sup 3+} spin reorientation, and a second sharper feature at about 45 K associated to the appearance of irreversibility on the magnetic susceptibility curves. In contrast to the lack of magnetic field impact on {epsilon} Prime for the former anomaly, a complex magnetic field effect has been evidenced below 45 K. The isothermal {epsilon} Prime (H) curves show the existence of positive magnetodielectric effect, reaching a maximum of 0.14% at 3 T and 10 K. Its magnitude decreases as H is further increased. Interestingly, for the lowest H values, a linear regime in the {epsilon} Prime (H) curve is observed. From this experimental study, it is concluded that the {epsilon} Prime anomaly, starting above the compensation temperature T{sub c} (75 K) and driven by the internal magnetic field, is not sensitive to an applied external magnetic field. Thus, below 45 K, it is the magnetic structure which is responsible for the coupling between spin and charge in this iron garnet.

36 MATERIALS SCIENCE↗

Palm top plasma focus device as a portable pulsed neutron source

Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

43 PARTICLE ACCELERATORS↗

First principles study of the structural, electronic, and transport properties of triarylamine-based nanowires

We investigate with state of the art density functional theory the structural, electronic, and transport properties of a class of recently synthesized nanostructures based on triarylamine derivatives. First, we consider the single molecule precursors in the gas phase and calculate their static properties, namely (i) the geometrical structure of the neutral and cationic ions, (ii) the electronic structure of the frontier molecular orbitals, and (iii) the ionization potential, hole extraction potential, and internal reorganization energy. This initial study does not evidence any direct correlation between the properties of the individual molecules and their tendency to self-assembly. Subsequently, we investigate the charge transport characteristics of the triarylamine derivatives nanowires, by using Marcus theory. For one derivative we further construct an effective Hamiltonian including intermolecular vibrations and evaluate the mobility from the Kubo formula implemented with Monte Carlo sampling. These two methods, valid respectively in the sequential hopping and polaronic band limit, give us values for the room-temperature mobility in the range 0.1–12 cm{sup 2}/Vs. Such estimate confirms the superior transport properties of triarylamine-based nanowires, and make them an attracting materials platform for organic electronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of respiratory motion on internal radiation dosimetry

Purpose: Estimation of the radiation dose to internal organs is essential for the assessment of radiation risks and benefits to patients undergoing diagnostic and therapeutic nuclear medicine procedures including PET. Respiratory motion induces notable internal organ displacement, which influences the absorbed dose for external exposure to radiation. However, to their knowledge, the effect of respiratory motion on internal radiation dosimetry has never been reported before. Methods: Thirteen computational models representing the adult male at different respiratory phases corresponding to the normal respiratory cycle were generated from the 4D dynamic XCAT phantom. Monte Carlo calculations were performed using the MCNP transport code to estimate the specific absorbed fractions (SAFs) of monoenergetic photons/electrons, the S-values of common positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124), and the absorbed dose of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) in 28 target regions for both the static (average of dynamic frames) and dynamic phantoms. Results: The self-absorbed dose for most organs/tissues is only slightly influenced by respiratory motion. However, for the lung, the self-absorbed SAF is about 11.5% higher at the peak exhale phase than the peak inhale phase for photon energies above 50 keV. The cross-absorbed dose is obviously affected by respiratory motion for many combinations of source-target pairs. The cross-absorbed S-values for the heart contents irradiating the lung are about 7.5% higher in the peak exhale phase than the peak inhale phase for different positron-emitting radionuclides. For {sup 18}F-FDG, organ absorbed doses are less influenced by respiratory motion. Conclusions: Respiration-induced volume variations of the lungs and the repositioning of internal organs affect the self-absorbed dose of the lungs and cross-absorbed dose between organs in internal radiation dosimetry. The dynamic anatomical model provides more accurate internal radiation dosimetry estimates for the lungs and abdominal organs based on realistic modeling of respiratory motion. This work also contributes to a better understanding of model-induced uncertainties in internal radiation dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increase in the internal optical loss with increasing pump current and the output power of quantum well lasers

The operating characteristics of semiconductor quantum-well lasers, calculated with consideration for an increase in the internal optical loss in the waveguide region with increasing pump current, are presented. The condition of global electroneutrality in the structure is used. This condition consists in that the total charge of electrons in the 2D active region (quantum well) and bulk waveguide region (optical confinement layer) is equal to the total charge of holes in these two regions. Good agreement between the calculated and experimentally determined light–current characteristics is obtained.

36 MATERIALS SCIENCE↗

Exploring the Use of Flexible Circuit Boards to the Increase Power Density of a Rotary Triboelectric Nanogenerator

EExpansion on previous triboelectric nanogenerator (TENG) research that investigated a freestanding rotary TENG. The previous prototype used a single printed circuit board (PCB) stator with exposed copper electrodes and an arcylic rotor with vinyl-cut fluorinated ethylene propylene (FEP) wedges. The second generation prototype again used a PCB stator but used a flexible PCB rotor consisting of alternating polyamide and copper wedges. This prototype was assembled in a stacked configuration, with the intent of increasing current output. Results indicated that the internal resistance of the prototype was decreased, allowing for higher current output. However, degradation of the power output was observed, which led to decay testing of the prototypes. To overcome charge decay, a self-exciting design is suggested as further work.

42 ENGINEERING↗