Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Synergy of Coupled Kink and Tearing Modes in Fast Ion Transport

One aspect of the interaction between fast ions and magnetohydrodynamic (MHD) instabilities is the fast ion transport. Coupled kink and tearing MHD instabilities have also been reported to cause fast ion transport. Recently, the ''kick" model has been developed to compute the evolution of the fast ion distribution from the neutral beam injection using instabilities as phase space resonance sources. The goal of this paper is to utilize the kick model to understand the physics of fast ion transport caused by the coupled kink and tearing modes. Soft X-ray diagnostics are used to identify the mode parameters in NSTX. The comparison of neutron rates measured and computed from time-dependent TRANSP simulation with the kick model shows the coupling of kink and tearing mode is important in determination of the fast ion transport. The numerical scan of the mode parameters shows that the relative phase of the kink and tearing modes and the overlapping of kink and tearing mode resonances in the phase space can affect the fast ion transport, suggesting that the synergy of the coupled modes may be causing the fast ion transpor

Energetic Particles↗

Integrated photonic structures for photon-mediated entanglement of trapped ions

Trapped atomic ions are natural candidates for quantum information processing and have the potential to realize or improve quantum computing, sensing, and networking. These applications often require the collection of individual photons emitted from ions into guided optical modes, in some cases for the production of entanglement between separated ions. Proof-of-principle demonstrations of such photon collection from trapped ions have been performed using high-numerical-aperture lenses or cavities and single-mode fibers, but integrated photonic elements in ion-trap structures offer advantages in scalability and manufacturability over traditional optics. In this paper we analyze structures monolithically fabricated with an ion trap for collecting ion-emitted photons, coupling them into waveguides, and manipulating them via interference. We calculate geometric limitations on collection efficiency for this scheme, simulate a single-layer grating that shows performance comparable to demonstrated free-space optics, and discuss practical fabrication and fidelity considerations. Based on this analysis, we conclude that integrated photonics can support scalable systems of trapped ions that can distribute quantum information via photon-mediated entanglement.

Knollmann, Felix W.↗

A new center for heavy ion research

Progress in cancer therapy with ions heavier than protons, i.e., helium, carbon, oxygen and neon, requires research and development capability. Ion research activity, however, is limited from the absence of U.S. accelerator facilities offering ion beams for therapy – placing the U.S. significantly behind Europe and Asia. With dramatic advances in beam delivery and compact accelerators, the potential exists to create a facility that can play a leadership role in particle therapy and ion-based research. This paper announces summary details of a new center for ion therapy research under construction in Waco, TX, in collaboration with recognized accelerator entities both academic and industrial. The advanced accelerator technologies will produce beams for both clinical and research applications, offering a complete range of ions, intensities and energies required by the medical community, including the capability to perform ultra-high dose irradiation (FLASH) research. FLASH, a recent research initiative, which has the potential of reducing cancer treatment toxicities, is an important if not critical capability for a competitive research center – requiring beam intensities well beyond those provided by current medical accelerators. Building a state-of-the-art cancer research center within a comprehensive facility will provide the resources to promote ion therapy in the U.S, including, preclinical/clinical trials and protocols between modalities, and also support broad ion R&D.

43 PARTICLE ACCELERATORS↗

Considering Factors for Ion Concentrations in Precipitation at the Savannah River Site

Precipitation was collected from three different areas on the Savannah River Site during 2021. The precipitation was analyzed for concentrations of 29 different ions and compared with data on factors such as wind speed, wind direction, rain drop sizes, and more. The 2021 ion concentrations were also compared to the ion concentrations from previous years at the site as well as from Santee National Wildlife Refuge which is nearby. The historical ion concentrations data was gathered from the National Atmospheric Deposition Program. Scatter plots and correlation coefficients were used to identify what factors may have the greatest impact on ion concentration in rainwater. The data generally followed the same trends with a few notable outliers. There initially seemed to be a strong correlation between the mean diameter and some ion concentrations as both increased in July. However, ion concentrations in different areas were related to different wind directions, thus spatial variability must be considered. These factors, spatial variability of atmospheric particles and wind direction, impact concentrations of ions in precipitation.

54 ENVIRONMENTAL SCIENCES↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Product ion distributions using H 3 O + proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS): mechanisms, transmission effects, and instrument-to-instrument variability

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) using hydronium ion (H3O+) ionization is widely used for the measurement of volatile organic compounds (VOCs) both indoors and outdoors. H3O+ ionization, as well as the associated chemistry in an ion–molecule reactor, is known to generate product ion distributions (PIDs) that include other product ions besides the proton-transfer product. We present a method, using gas-chromatography pre-separation, for quantifying PIDs from PTR-MS measurements of nearly 100 VOCs of different functional types including alcohols, ketones, aldehydes, acids, aromatics, organohalides, and alkenes. We characterize instrument configuration effects on PIDs and find that reactor reduced electric field strength (E/N), ion optic voltage gradients, and quadrupole settings have the strongest impact on measured PIDs. Through an interlaboratory comparison of PIDs measured from calibration cylinders, we characterized the variability of PID production from the same model of PTR-MS across seven participating laboratories. Product ion variability was generally smaller (e.g., < 20 %) for ions with larger contributions to the PIDs (e.g., > 0.30) but less predictable for product ions formed through O2+ and NO+ reactions. We present a publicly available library of H3O+ PTR-MS PIDs that will be updated periodically with user-provided data for the continued investigation into instrument-to-instrument variability of PIDs.

Link, Michael F. (ORCID:0000000218412455)↗

Observing one-divalent-metal-ion-dependent and histidine-promoted His-Me family I-PpoI nuclease catalysis in crystallo

Metal-ion-dependent nucleases play crucial roles in cellular defense and biotechnological applications. Time-resolved crystallography has resolved catalytic details of metal-ion-dependent DNA hydrolysis and synthesis, uncovering the essential roles of multiple metal ions during catalysis. The histidine-metal (His-Me) superfamily nucleases are renowned for binding one divalent metal ion and requiring a conserved histidine to promote catalysis. Many His-Me family nucleases, including homing endonucleases and Cas9 nuclease, have been adapted for biotechnological and biomedical applications. However, it remains unclear how the single metal ion in His-Me nucleases, together with the histidine, promotes water deprotonation, nucleophilic attack, and phosphodiester bond breakage. By observing DNA hydrolysis in crystallo with His-Me I-PpoI nuclease as a model system, we proved that only one divalent metal ion is required during its catalysis. Moreover, we uncovered several possible deprotonation pathways for the nucleophilic water. Interestingly, binding of the single metal ion and water deprotonation are concerted during catalysis. Our results reveal catalytic details of His-Me nucleases, which is distinct from multi-metal-ion-dependent DNA polymerases and nucleases.

59 BASIC BIOLOGICAL SCIENCES↗

Experiment S026: Ion wake measurement

Measurements of the ion-wake and electron-wake structure and other perturbations of the ambient medium produced by the Gemini spacecraft in orbit are reported. Thruster firings in the TDA-south configuration produced a decrease in the observed ion flux to the outboard ion sensor, an apparent increase in the ion flux to the inboard ion sensor, and an enhanced electron concentration to the outboard electron sensor. Visual inspection of strip-chart data was indicative that definitive wake-cone angles could be determined. It also was apparent for many cases that the electron distribution followed the ion depletion effects; this was indicative that the wake was a plasma, not an ion wake. Analysis of the data from the GATV orbits was indicative that electron and ion temperatures were higher than was estimated. The high electron temperature accounted for the sensor saturation observed during the mission. This temperature measurement was 0.3 electron volt at a 200-n. mi. altitude during daytime conditions. Spacecraft wake structure has been observed as far as 100 feet from the vehicle.

Medved, D. B.↗

Spacecraft ion beam noise effects

An estimate of the antenna noise temperature and the uplink signal-to-noise ratio has been made for Bremsstrahlung radiation emitted by a spacecraft ion beam; a worst-case situation in which the spacecraft antenna is located in the exit plane of the ion beam and directed at varying angles into the ion beam is assumed. Numerical results of the antenna noise temperature versus antenna pointing angle are given for a typical set of ion beam and antenna pattern parameters. The uplink signal-to-noise ratio due to the ion beam noise alone is given in terms of a critical range in AU at which a typical ranging transmission is received with S/N = 0 db. The effects of the ion beam divergence angle and antenna distance on the ion beam are also presented. Results of the study show typical increases in the antenna noise temperature of about 0.2 K and critical ranges of the order of 3-5 AU. An ion engine thus generally introduces an undetectable level of noise into a spacecraft receiver.

Anenberg, G. L.↗

The electron heating rate and ion chemistry in the thermosphere above Wallops Island during the solar eclipse of 7 March 1970.

Measurement of the N2 concentration and temperature, the ion composition and concentrations, and the electron temperature up to 290 km about 30 and 5 min before totality during the Mar. 7, 1970, eclipse. The rockets traveled similar trajectories, thus permitting the purely temporal changes between flights to be resolved. The neutral temperature and N2 concentration changed little, but the electron temperature decreased by as much as 20% in the lower F region. The ion concentration decreased by about 30% in the F region and about 50% in the E region, with little change in relative ion composition. The electron cooling rates decreased by a factor of 6 in the lower F region, approximately in proportion to the change in the visible solar disk. A smaller than expected decrease in the cooling rate below 150 km between the two flights indicates a hardening of the solar spectrum and suggests a significant heat contribution from the solar corona near totality. The ion composition measurements were consistent with solutions of the ion continuity equations. A proper fit required a factor-of-three enhancement of the flux below 200 A, an amount also consistent with the electron heat balance analysis. Reactions involving the minor ions N(+) and N2(+) were found to be important for the ion chemistry of the major ions O2(+) and NO(+), especially at the time of eclipse.-

Brace, L. H.↗

Suprathermal ion detector results from Apollo missions.

This paper reviews briefly the knowledge of the ion environment of the moon as obtained from the Apollo Lunar Surface Experiments Package, Suprathermal Ion Detector Experiment. Topics to be discussed include: an interplanetary shock as seen from the lunar surface; bow shock and magnetosheath ions; magnetotail plasma seen during a magnetic disturbance; suprathermal ions seen during passage of the sunset and sunrise terminators; and ions associated with neutral gas clouds in the vicinity of the moon, and in particular the low energy mono-energetic spectrum of these ions. It is believed that these low energy spectra and some terminator ions can be explained by ion acceleration by the interplanetary electric field. This paper serves as catalog to references to these and other related phenomena.

Freeman, J. W., Jr.↗

Heavy ion plasma confinement in an RF quadrupole trap

The confinement of an electron free plasma in a pure quadrupole RF electric trap was considered. The ultimate goal was to produce a large density of mercury ions, in order to realize a trapped ion frequency standard using the hyperfine resonance of 199 Hg(+) at 40.7 GHz. An attempt was made to obtain an iodine plasma consisting of equal numbers of positive and negative ions of atomic iodine, the positive iodine ions, being susceptible to charge-exchange with mercury atoms, will produce the desired mercury ions. The experiment showed that the photoproduction of ions pairs in iodine using the necessary UV radiation occurs with a small cross-section, making it difficult to demonstrate the feasibility of space charge neutralization in a quadrupole trap. For this reason it was considered expedient to choose thallium iodide, which has a more favorable absorption spectrum (in the region of 2000 to 2100 A). The results indicate that, although the ionic recombination is a serious limiting factor, a considerable improvement can be obtained in practice for the density of trapped ions, with a considerable advantage in lifetimes for spectroscopic purposes. The ion pair formation by photoionization is briefly reviewed.

Schermann, J.↗

Behaviour of ion velocity distributions for a simple collision model

Calculation of the ion velocity distributions for a weakly ionized plasma subjected to crossed electric and magnetic fields. An exact solution to Boltzmann's equation has been obtained by replacing the Boltzmann collision integral with a simple relaxation model. At altitudes above about 150 km, where the ion collision frequency is much less than the ion cyclotron frequency, the ion distribution takes the shape of a torus in velocity space for electric fields greater than 40 mV/m. This shape persists for one to two hours after application of the electric field. At altitudes where the ion collision and cyclotron frequencies are approximately equal (about 120 km), the ion velocity distribution is shaped like a bean for large electric field strengths. This bean-shaped distribution persists throughout the lifetime of ionospheric electric fields. These highly non-Maxwellian ion velocity distributions may have an appreciable affect on the interpretation of ion temperature measurements.

St-Maurice, J.-P.↗

The measurement of cold ion densities in the plasma trough

The cold ion density in the plasma trough region is an important fundamental parameter in the currently proposed mechanisms to describe magnetospheric dynamics. Direct in situ measurements of the cold ion density are generally difficult owing to uncertainties in vehicle potentials and ion temperatures. It is shown that the light ion mass spectrometer from Ogo 5 was very successful in acquiring these data and that vehicle potentials appear not to have been a prohibitive factor. The cold ion plasma trough data show a great deal of variability, indicating a strong dependence on the state of the convection electric field; consequently, average values of cold ion densities in the plasma trough may be significantly different from the actual time-dependent values. The local time plot of plasma trough densities at L = 7 for data acquired over a 1-year period shows the anticipated increase in cold ion density during the daytime and the expected decrease in cold ion density during dusk and early nighttime.

Harris, K. K.↗

The 15 cm mercury ion thruster research 1975

Doubly charged ion current measurements in the beam of a SERT II thruster are shown to introduce corrections which bring its calculated thrust into close agreement with that measured during flight testing. A theoretical model of doubly charged ion production and loss in mercury electron bombardment thrusters is discussed and is shown to yield doubly-to-singly charged ion density ratios that agree with experimental measurements obtained on a 15 cm diameter thruster over a range of operating conditions. Single cusp magnetic field thruster operation is discussed and measured ion beam profiles, performance data, doubly charged ion densities, and discharge plasma characteristics are presented for a range of operating conditions and thruster geometries. Variations in the characteristics of this thruster are compared to those observed in the divergent field thruster and the cusped field thruster is shown to yield flatter ion beam profiles at about the same discharge power and propellant utilization operating point. An ion optics test program is described and the measured effects of grid system dimensions on ion beamlet half angle and diameter are examined. The effectiveness of hollow cathode startup using a thermionically emitting filament within the cathode is examined over a range of mercury flow rates and compared to results obtained with a high voltage tickler startup technique. Results of cathode plasma property measurement tests conducted within the cathode are presented.

Wilbur, P. J.↗

Scanning-electron-microscopy observations and mechanical characteristics of ion-beam-sputtered surgical implant alloys

An electron bombardment ion thruster was used as an ion source to sputter the surfaces of orthopedic prosthetic metals. Scanning electron microscopy photomicrographs were made of each ion beam textured surface. The effect of ion texturing an implant surface on its bond to bone cement was investigated. A Co-Cr-W alloy and surgical stainless steel were used as representative hard tissue implant materials to determine effects of ion texturing on bulk mechanical properties. Work was done to determine the effect of substrate temperature on the development of an ion textured surface microstructure. Results indicate that the ultimate strength of the bulk materials is unchanged by ion texturing and that the microstructure will develop more rapidly if the substrate is heated prior to ion texturing.

Weigand, A. J.↗

Substorm generated fluxes of heavy ions at the geostationary orbit

Measurements of heavy energetic heavy ions present in the vicinity of the geostationary orbit of the ATS-6 satellite, taken with the aid of a solid-state detector telescope, are reported and analyzed. Data extracted from a single fairly isolated injection event (June 18, 1974) are examined: ions of Z not below 6 and energy above 4.0 MeV; energization of these heavy ions in the magnetosphere during substorm events; comparison of the heavy ion intensity and proton intensity; ratio of intensity of carbon ions and oxygen ions. The heavy ions are identified with oxygen for the most part. The heavy-ion spectrometer is described.

Fritz, T. A.↗

Mechanical properties of ion-beam-textured surgical implant alloys

An electron-bombardment Hg ion thruster was used as an ion source to texture surfaces of materials used to make orthopedic and/or dental prostheses or implants. The materials textured include 316 stainless steel, titanium-6% aluminum, 4% vanadium, and cobalt-20% chromium, 15% tungsten. To determine the effect of ion texturing on the ultimate strength and yield strength, stainless steel and Co-Cr-W alloy samples were tensile tested to failure. Three types of samples of both materials were tested. One type was ion-textured (the process also heats each sample to 300 C), another type was simply heated to 300 C in an oven, and the third type was untreated. Stress-strain diagrams, 0.2% offset yield strength data, total elongation data, and area reduction data are presented. Fatigue specimens of ion textured and untextured 316 stainless steel and Ti-6% Al-4% V were tested. Included as an ion textured sample is a Ti-6% Al-4% V sample which was ion machined by means of Ni screen mask so as to produce an array of 140 mu m x 140 mu m x 60 mu m deep pits. Scanning electron microscopy was used to characterize the ion textured surfaces.

Weigand, A. J.↗