SEARCH · Engineering Papers
Results for “INNOVATION”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution
The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.
An Innovative Tool for Intraoperative Electron Beam Radiotherapy Simulation and Planning: Description and Initial Evaluation by Radiation Oncologists
Purpose: Intraoperative electron beam radiation therapy (IOERT) involves a modified strategy of conventional radiation therapy and surgery. The lack of specific planning tools limits the spread of this technique. The purpose of the present study is to describe a new simulation and planning tool and its initial evaluation by clinical users. Methods and Materials: The tool works on a preoperative computed tomography scan. A physician contours regions to be treated and protected and simulates applicator positioning, calculating isodoses and the corresponding dose-volume histograms depending on the selected electron energy. Three radiation oncologists evaluated data from 15 IOERT patients, including different tumor locations. Segmentation masks, applicator positions, and treatment parameters were compared. Results: High parameter agreement was found in the following cases: three breast and three rectal cancer, retroperitoneal sarcoma, and rectal and ovary monotopic recurrences. All radiation oncologists performed similar segmentations of tumors and high-risk areas. The average applicator position difference was 1.2 {+-} 0.95 cm. The remaining cancer sites showed higher deviations because of differences in the criteria for segmenting high-risk areas (one rectal, one pancreas) and different surgical access simulated (two rectal, one Ewing sarcoma). Conclusions: The results show that this new tool can be used to simulate IOERT cases involving different anatomic locations, and that preplanning has to be carried out with specialized surgical input.
Initial Feasibility and Clinical Implementation of Daily MR-Guided Adaptive Head and Neck Cancer Radiation Therapy on a 1.5T MR-Linac System: Prospective R-IDEAL 2a/2b Systematic Clinical Evaluation of Technical Innovation
This prospective study is, to our knowledge, the first report of daily adaptive radiation therapy (ART) for head and neck cancer (HNC) using a 1.5T magnetic resonance imaging-linear accelerator (MR-linac) with particular focus on safety and feasibility and dosimetric results of an online rigid registration-based adapt to position (ATP) workflow.
Strategic Training in Transdisciplinary Radiation Science for the 21st Century (STARS21): 15-Year Evaluation of an Innovative Research Training Program
To evaluate the 15-year impact of a transdisciplinary research training program for graduate students, postdoctoral fellows, and clinical trainees focused on radiation science, entitled Strategic Training in Transdisciplinary Radiation Science for the 21st Century (STARS21) with a primary objective to build capacity in radiation research.
An innovative zinc oxide-coated zeolite adsorbent for removal of humic acid
Not Available
An innovative radial gradient material design using hot isostatic pressing for applications in extreme environments
Functionally graded materials (FGMs) are highly advanced continuous or discontinuous structures whose structural and material properties vary along a singular geometric dimension either in the axial or radial direction. Here, the radial gradient FGM design makes for an optimal structural design to incorporate a bi-metallic structure with a copper-based high entropy alloy (Cu-HEA) with good mechanical properties and high irradiation resistance, and Chromium (Cr) with great corrosion resistance. This study focuses on the experimental design of a metal powder loading mechanism to fabricate a bi-metallic radial gradient structure using Cu-HEA and 99.9 % pure Cr metal powders. The powder loading strategy uses custom-designed concentric cylindrical dividers to separate the individual compositions. Two benchtop trial runs were performed for design optimization. The optimized design was then implemented to eventually load the HEA and Cr powders for consolidation via powder metallurgy hot isostatic pressing (PM-HIP). The electron microscopy analysis reveals the successful fabrication of the radial gradient structure with the chemical mapping analysis, demonstrating the gradual composition shift from the HEA at the center to the pure-Cr at the periphery via a three-step gradient.
Innovation, Impact, and Strategic Importance of Alpha-Emitting Radionuclides
Not Available
Application of the radiating divertor approach to innovative tokamak divertor concepts
Not Available
Innovative Chemicals and Materials from Bacterial Aromatic Catabolic Pathways
Not Available
Advancing electrochemical impedance analysis through innovations in the distribution of relaxation times method
Electrochemical impedance spectroscopy (EIS) is a key tool across various scientific disciplines, including energy sciences, chemistry, and biology, enabling the analysis of electrochemical systems. However, conventional methods for interpreting EIS data are often complex and model dependent. The distribution of relaxation times (DRT) offers a non-parametric approach that simplifies the interpretation process by providing a timescale interpretation of EIS data. This article provides a comprehensive review of current methods for DRT inversion. Additionally, a survey of practitioners highlights key challenges in the field. Here, the findings underscore the need for standardized DRT analysis and benchmarks, as well as the development of automated analysis tools. These advancements would improve the usability and interpretability of EIS data. Ultimately, implementing these improvements could not only propel the field forward but also expand the application of DRT in scientific research by making it accessible to a broader range of researchers, including those without specialized expertise in programming or statistics.
Recent developments in competition and innovation for regulated electric utilities
The electric utility industry is currently undergoing substantial evolution. Here, recent technological advancements, as well as changing customer demands, are expanding the number and type of electric utility grid services and product offerings to end-use customers.
Cooperation and the emergence of maritime clusters in the Atlantic: Analysis and implications of innovation and human capital for blue growth
Not Available
Innovative methodology for the synthesis of Ba-M hexaferrite BaFe{sub 12}O{sub 19} nanoparticles
Graphical abstract: Transmission electron microscope images for the BaFe12O19. - Highlights: • BaFe{sub 12}O{sub 19}nanoparticles were prepared in single-phase from organometallic precursors. • BaFe{sub 12}O{sub 19} possesses small size 65 nm, H{sub C} = 3695 Oe and M{sub s} = 58 emu/g. • This method of preparation could be extended in the synthesis of other metal oxide nanoparticles. - Abstract: In this piece of work, high quality and homogeneity, barium hexaferrite (BaM) BaFe{sub 12}O{sub 19} nanoparticles were prepared from organometallic precursors for the 1st time. This method is based on the formation of supramolecular crystal structure of Ba[Fe(H{sub 3}NCH{sub 2}CH{sub 2}NH{sub 3})]Cl{sub 7}·8H{sub 2}O. The crystal structure, morphology and magnetic properties of BaFe{sub 12}O{sub 19} at two different annealing temperatures namely 1000 °C and 1200 °C were investigated using X-ray diffraction, transmission electron microscope TEM and vibrating sample magnetometry (VSM). The results show that monophasic nanoparticles of hexaferrites were obtained. Nanoparticles of crystallite size 40–50 nm distinguished by narrow distribution and excellent homogeneity were obtained with superior magnetic properties which suggested single-domain particles of Ba-M hexaferrite.
TENDL: Complete Nuclear Data Library for Innovative Nuclear Science and Technology
The TENDL library is now established as one of the major nuclear data libraries in the world, striving for completeness and quality of nuclear data files for all isotopes, evaluation methods, processing and applied performance. To reach this status, some basic principles have been applied which sets it apart from other libraries: reproducible dedicated evaluations when differential data are available, through determination of nuclear models implemented in TALYS and their parameters, completeness (with or without experimental data), format and processing standardization, automation of production and reproducibility. In this paper, we will outline how such an approach has become a reality, and recall some of the past successes since the first TENDL release in 2008. Next, we will demonstrate the performance of the latest TENDL releases for different application fields, as well as new approaches for uncertainty quantification based on Bayesian inference methods and possible differential and integral adjustments. Also, current limitations of the library performances due to modelling and needs for new and more precise experimental data will be outlined.
Tests of innovative photon detectors and integrated electronics for the large-area CLAS12 ring-imaging Cherenkov detector
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab. Its aim is to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and a densely packed and highly segmented photon detector. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). Extensive tests have been performed on Hamamatsu H8500 and novel flat multi-anode photomultipliers under development and on various types of silicon photomultipliers. A large scale prototype based on 28 H8500 MA-PMTs has been realized and tested with few GeV/c hadron beams at the T9 test-beam facility of CERN. In addition a small prototype was used to study the response of customized SiPM matrices within a temperature interval ranging from 25 down to –25 °C. The preliminary results of the individual photon detector tests and of the prototype performance at the test-beams are here reported.