Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Coherent X-ray Diffraction Imaging of Zeolite Microcrystals

We measured coherent x-ray diffraction (CXD), an emerging technique to obtain three-dimensional internal and external images of crystals, on ZSM-5 zeolite microcrystals to get internal density distribution and to map deformation field of strain. The experiments were performed at the beamline 34-ID-C in Advanced Photon Source at Argonne National Laboratory in the US. The CXD patterns of ZSM-5 zeolite microcrystals with sizes of 2 {mu}m by monochromatic coherent x-rays with energy of 9 keV were obtained under continuously surrounding and Bragg conditions as a function of temperature. The oversampled diffraction patterns are inverted to obtain three-dimensional images of the shapes and internal strain fields of zeolite microcrystals using phase retrieval algorithms of error reduction and a hybrid input-output method. The internal density and strain distribution as a function of temperature are discussed.

36 MATERIALS SCIENCE↗

Optimization study for non-standard interaction search in a neutrino factory

We study the optimization of a neutrino factory with respect to non-standard neutral current neutrino interactions. We discuss the muon energy, baselines, and oscillation channels as degrees of freedom. We consider all possible non-standard parameters, and include their complex phases. We identify the impact of the different parameters on the golden, silver, and disappearance channels. We come to the conclusion that, even in the presence of non-standard interactions, the performance of the neutrino factory hardly profits from a silver channel detector. We demonstrate that the IDS-NF setup is close to optimal even if non-standard interactions are considered. We find that one very long baseline is a key component in the search for non-standard interactions, in particular for epsilon{sub m}u{sub t}au{sup m} and epsilon{sub t}au{sub t}au{sup m}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Injection/Extraction Studies for the Muon FFAG

The non-scaling fixed field alternating gradient (NS-FFAG) ring is a candidate muon accelerator in the Neutrino Factory complex according to the present baseline, which is currently being addressed by the International Design Study (IDS-NF). In order to achieve small orbit excursion, motivated by magnet cost reduction, and small time of flight variation, dictated by the need to use high RF frequency, lattices with a very compact cell structure and short straight sections are required. The resulting geometry dictates very difficult constraints on the injection/extraction systems. Beam dynamics in the non-scaling FFAG is studied using codes capable of correctly tracking with large transverse amplitude and momentum spread. The feasibility of injection/extraction is studied and various implementations focusing on minimization of kicker/septum strength are presented. Finally the parameters of the resulting kicker magnets are estimated.

43 PARTICLE ACCELERATORS↗

On near detectors at a neutrino factory

The geometric effects of the beam in near detectors at a neutrino factory are discussed. The refined systematics treatment, including cross section errors, flux errors and background uncertainties, is compared with the IDS-NF one. Different near detector setups are included. We also probe their effects both at the measurements of standard neutrino oscillation parameters and constraints of the non-standard neutrino interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE MAGNETOHYDRODYNAMIC RESPONSE OF LIQUID OXYGEN: EXPERIMENTATION AND SIMULATION

Experimental and theoretical studies have been conducted to establish the basic understanding and predictive capability for the dynamics of a liquid oxygen (LOX) slug subjected to magnetic fields within a solenoid. The electrically-pulsed solenoids around a 1.9 mm ID quartz tube were capable of producing up to 1.1 T when immersed in liquid nitrogen. The slug dynamics were measured by pressure changes in a closed volume on both sides of the slug. A theoretical model was developed which balances the magnetic, viscous, and pressure forces into a single equation of motion. The model was applied to a one-dimensional discretized algorithm that solved the coupled multiphysics problem of the Navier-Stokes and Maxwell's equations. The simulation and experimental results established LOX as a good candidate in a magnetic fluid system without moving parts for cryogenic applications.

36 MATERIALS SCIENCE↗

An Innovative Transponder-Based Interferometric Radar for Vibration Measurements

Ground-based radar interferometry has recently emerged as an innovative technology of remote sensing, able to accurately measure the static or dynamic displacement of several points of a structure. This technique in the last couple of years has been applied to different types of structures, such as bridges, towers and chimneys. This paper presents a prototype system developed by IDS, originally aimed at measuring the structural vibrations of helicopter rotor blades, based on an interferometric technique and constituted by combination of a radar sensor and a series of transponders installed on the target structure. The main advantages of this solution with respect to conventional interferometric radars, are related to the increased spatial resolution of the system, provided by the possibility to discriminate different transponders installed within the same resolution cell of the radar sensor, and to the reduction of the ambient noise (e.g. multi-path) on the radar measurement. The first feature allows the use of the microwave technology even on target areas with limited dimensions, such as industrial facilities, while the second aspect may extend the use of radar interferometric systems to complex scenarios, where multi-reflections are expected due to the presence of natural targets with high reflectivity to the radar signal. In the paper, the system and its major characteristics are first described; subsequently, application to the measurement of ambient vibration response of a lab set-up is summarized. Then the data acquired on a rotating mock-up are reported and analyzed to identify natural frequencies and mode shapes of the investigated structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Status of the Taiwan Photon Source

NSRRC has been operating a 1.5 GeV synchrotron light source, the Taiwan Light Source (TLS), for over 15 years and has established a large user community. For the future development of synchrotron radiation research in Taiwan, a feasibility study report to construct a 3.0 GeV low-emittance storage ring, the Taiwan Photon Source (TPS), was issued in July 2005. The government approval of the TPS project was obtained in December 2007 and the machine will be built at current site of NSRRC. The project has progressed steadily since and reached several major milestones now: the architect firm has finished the site plan and civil design, the accelerator design has been fixed, and purchase of long-lead items begins its course. The TPS storage ring has a circumference of 518.4 meters with a concentric booster of 496.8 meters. The storage ring adopted a 24-cell double-bend structure with a 1.6 nm-rad natural emittance. There are six 12-m and eighteen 7-m ID straights. For user research, five new beamlines have been selected for the Phase I operations: the micro protein crystallography, the materials sub-micron diffraction, the inelastic soft x-ray scattering, the coherent x-ray scattering, and the nano probe beamlines. The civil construction is getting ready to start. The commissioning of the TPS storage ring is targeted for 2013.

43 PARTICLE ACCELERATORS↗

A panoply of insertion devices at SOLEIL for a wide spectral range and flexible polarisation

The SOLEIL storage ring presents a very high fraction of its circumference dedicated to accommodate Insertion Devices (ID). Over the 25 presently planned insertion devices presenting a large variety of systems, 16 have been already installed and commissioned in September 2009. The UV-VUV region is covered with electromagnetic devices, offering tuneable polarisations. An electromagnet/permanent magnet undulator using copper sheets coils for fast switching of the helicity is under construction. 13 APPLE-II type undulators, with period ranging from 80 down to 36 mm, provide photons in the 0.1-10 keV region, some of them featuring tapering or quasi-periodicity. Five U20 in vacuum undulators cover typically the 3-30 keV range whereas an in vacuum wiggler, with compensation of the magnetic forces via adequate springs will cover the 10-50 keV spectral domain. R and D on cryogenic in-vacuum undulator is also under progress. A magnetic chicane using permanent magnet dipoles has also been designed in order to accommodate two canted undulators on the same straight section. A wiggler dedicated to slicing (production of femto second long pulses) is also being designed, its radiation will also serve for an X-ray beamline.

43 PARTICLE ACCELERATORS↗

Confocal Microscope Alignment of Nanocrystals for Coherent Diffraction Imaging

We have installed and tested an Olympus LEXT confocal microscope at the 34-ID-C beamline of the Advanced Photon Source (APS). The beamline is for Coherent X-ray Diffraction (CXD) experiments in which a nanometre-sized crystal is aligned inside a focussed X-ray beam. The microscope was required for three-dimensional (3D) sample alignment to get around sphere-of-confusion issues when locating Bragg peaks in reciprocal space. In this way, and by use of strategic sample preparations, we have succeeded in measuring six Bragg peaks from a single 200 nm gold crystal and obtained six projections of its internal displacement field. This enables the clear identification of stacking-fault bands within the crystal. The confocal alignment method will allow a full determination of the strain tensor provided three or more Bragg reflections from the same crystal are found.

43 PARTICLE ACCELERATORS↗

Visible Light Diagnostics at SPEAR3

The visible light diagnostic beam line at SPEAR3 utilizes dipole radiation extracted through an ID exit port to evaluate electron beam properties at a variety of diagnostic end-stations. The unfocused SR light is collected 17 m from the source point by a 150 mm diameter, f = 2 m lens and optically relayed to the appropriate station. For transverse imaging, an image-intensified PiMax camera with 2 ns gate allows measurement of fast beam dynamics for either the stored beam or the injected beam. For these applications the visible light is switched into either a standard symmetric-lens transport line or a beam-shaping transport line equipped with cylindrical lenses and a rotating mirror to sweep the beam image across the camera photocathode. A separate two slit stellar-interferometer branch line can resolve the diffraction-limited vertical beam height down to about 10 {mu}m. For longitudinal charge profile measurements, the light is switched to a Hamamatsu C5680 streak camera with net system resolution of {approx}2.5 ps rms. In this paper we outline the main photon beam transport line, review the SR beam properties and describe measurement capabilities at each diagnostic station.

43 PARTICLE ACCELERATORS↗

Amino Acids Profiles in Biological Media

An accurate analytical method was developed to determine amino acids in some biological specimens by GC/MS technique. Stable isotopes provide useful tools for a variety of studies, offering ideal internal standards in quantitative information. Isotopic dilution gas chromatography--mass spectrometry (ID-GC/MS) is the techniques used for quantitative analysis of compounds labeled with stable isotopes. A Trace DSQ Thermo Finnigan quadrupole mass spectrometer coupled with a Trace GC was used. Amino acids were separated on a Rtx-5 MS capillary column, 30 mx0.25 mm, 0.25 {mu}m film thickness, using a temperature program from 50 deg. C, 1 min, 6 deg. C/min at 100 deg. C, 4 deg. C/min at 200 deg. C, 20 deg. C/min at 300 deg. C, (3 min). The transfer line temperature was 250 deg. C, the injector temperature 200 deg. C and ion source temperature 250 deg. C; splitter: 10:1. Electron energy was 70 eV and emission current, 100 {mu}A. The amino acids were purified on a Dowex 50W-W8 exchange resin and were derivatized in a procedure following two steps to obtain trifluoroacetyl butyl esters. The identification of amino acids was obtained by using NIST library but also by using amino acid standards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CAST: An Inspiring Axion Helioscope ala Sikivie

CAST is a data taking axion helioscope using a recycled LHC test magnet, CERN's detector technology and cryogenics expertise. An imaging X-ray telescope improves substantially the detection sensitivity and axion-ID. Massive axion-like particles of the Kaluza-Klein type were first introduced to explain the paradox of the hot corona, which is even hotter at locations overlying magnetic spots. This is suggesting that the CAST detection principle might be at work there, but being somehow modified and performing better. Remarkably, the density profile of the Sun allows for resonance crossing (m{sub axion}c{sup 2{approx_equal}}h{omega}{sub plasma}), which axion helioscopes are aiming to reach. The restless Sun favours this occasionally even further. Then, such processes can give rise to a chimera of converted axions or the like, making the Sun appear, within known physics, as mysterious and unpredictable as it is. CAST axion limits were used to conclude also for the hidden sector paraphotons. This is then suggestive for novel helioscopes for exotica like paraphotons, chameleons, etc. Pierre Sikivie's pioneering idea was to use a magnetic field as a catalyst to transform particles from the dark sector to ours, and vice versa.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Classical Yang-Mills Mechanics: Instant vs. Light-cone Form

Two different forms of relativistic dynamics, the instant and the light-cone form, for the pure SU(2) Yang-Mills field theory in 4-dimensional Minkowski space are examined under the supposition that the gauge fields depend on the time evolution parameter only. The obtained under that restriction of gauge potential space homogeneity mechanical matrix model, sometimes called Yang-Mills classical mechanics, is systematically studied in its instant and light-cone form of dynamics using the Dirac's generalized Hamiltonian approach. In the both cases the constraint content of the obtained mechanical systems is found. In contrast to its well-known instant-time counterpart the light-cone version of SU(2) Yang-Mills classical mechanics has in addition to the constraints generating the SU(2) gauge transformations the new first and second class constraints also. On account of all of these constraints a complete reduction in number of the degrees of freedom is performed. In the instant form of dynamics it is shown that after elimination of the gauge degrees of freedom from the classical SU(2) Yang-Mills mechanics the resulting unconstrained system represents the ID{sub 3} Euler-Calogero-Moser model with a certain external fourth-order potential, whereas in the light-cone form it is argued that the classical evolution of the unconstrained degrees of freedom is equivalent to a free one-dimensional particle dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microfabrication of controlled-geometry samples for the laser-heated diamond-anvil cell using focused ion beam technology

The pioneering of x-ray diffraction with in situ laser heating in the diamond-anvil cell has revolutionized the field of high-pressure mineral physics, expanding the ability to determine high-pressure, high-temperature phase boundaries and equations of state. Accurate determination of high-pressure, high-temperature phases and densities in the diamond-anvil cell rely upon collinearity of the x-ray beam with the center of the laser-heated spot. We present the development of microfabricated samples that, by nature of their design, will have the sample of interest in the hottest portion of the sample. We report initial successes with a simplified design using a Pt sample with dimensions smaller than the synchrotron-based x-ray spot such that it is the only part of the sample that absorbs the heating laser ensuring that the x-rayed volume is at the peak hotspot temperature. Microfabricated samples, synthesized using methods developed at The Ohio State University's Mineral Physics Laboratory and Campus Electron Optics Facility, were tested at high P-T conditions in the laser-heated diamond-anvil cell at beamline 16 ID-B of the Advanced Photon Source. Pt layer thicknesses of {le} 0.8 {micro}m absorb the laser and produce accurate measurements on the relative equations of state of Pt and PtC. These methods combined with high-purity nanofabrication techniques will allow for extension by the diamond-anvil cell community to multiple materials for high-precision high-pressure, high-temperature phase relations, equations of state, melting curves, and transport properties.

43 PARTICLE ACCELERATORS↗

Density profile sensitivity study of ASDEX Upgrade ICRF Antennas with the TOPICA code

During operation of the ASDEX Upgrade (AUG) ion cyclotron radio frequency (ICRF) system, Tungsten (W)-coated poloidal limiters and structures connected along magnetic field lines to the antenna can be sources of W, which is attributed to sputtering by ions accelerated in radio frequency (RF) sheaths. In order to analyze and optimize the ICRF antenna performance, accurate and efficient simulation tools are necessary. TOPICA code was developed for analysis of ICRF antenna systems with plasma loading conditions modeled with ID FELICE code. This paper presents an initial comparative analysis of two AUG ICRF antennas for a set of model plasma density profiles (with varying density gradient and antenna cut-off distance). The antennas are presently installed in AUG and differ in that one was partially optimized using HFSS code to reduce E{sub ||} near fields. Power transferred to plasma and sheath driving RF potentials are computed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of KSTAR 170 GHz, 1 MW Electron Cyclotron Heating and Current Drive System

A 170 GHz Electron Cyclotron Heating and Current Drive (ECH/CD) system on KSTAR is designed to launch total 2.4 MW of power for up to 300 sec into the plasma. At present the first 1 MW ECH/CD system is under installation and commissioning for 2011 KSTAR campaign. The 170 GHz, 1 MW, 300 sec gyrotron and the matching optics unit (MOU) will be provided from JAEA under collaboration between NFRI and JAEA. The transmission line consists of MOU and 70 m long 63.5 mm ID corrugated waveguides with the eight miter bends. The 1 MW, 10 sec launcher is developed based on the existing two-mirror front-end launcher in collaboration with Princeton Plasma Physics Laboratory and Pohang University of Science and Technology, and is installed on the low field side in the KSTAR equatorial plane. The mirror pivot is located at 30 cm below from the equatorial plane. 3.6 MVA power supply system is manufactured and now is under commissioning to meet the triode gun operation of JAEA gyrotron. The power supply consists of 66 kV/55 A cathode power supply, mode-anode system, and 50 kV/160 mA body power supply. In this paper, the current status of KSTAR 170 GHz, 1 MW ECH/CD system will be presented as well as the experimental plan utilizing 170 GHz new ECH/CD system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Capillary Absorption Spectrometer for Stable Carbon Isotope Ratio (13C/12C) Analysis in Very Small Samples

A capillary absorption spectrometer (CAS) suitable for IR laser isotope analysis of small CO{sub 2} samples is presented. The system employs a continuous-wave (cw) quantum cascade laser to study nearly adjacent rovibrational transitions of different isotopologues of CO{sub 2} near 2307 cm{sup -1} (4.34 {mu}m). This initial CAS system can achieve relative isotopic precision of about 10 ppm {sup 13}C, or {approx}1{per_thousand} (per mil in delta notation relative to Vienna Pee Dee Belemnite) with 20-100 picomoles of entrained sample within the hollow waveguide for CO{sub 2} concentrations {approx}400 to 750 ppm. Isotopic analyses of such gas fills in a 1-mm ID hollow waveguide of 0.8 m overall physical path length can be carried out down to {approx}2 Torr. Overall {sup 13}C/{sup 12}C ratios can be calibrated to {approx}2{per_thousand} accuracy with diluted CO{sub 2} standards. A novel, low-cost method to reduce cw-fringing noise resulting from multipath distortions in the hollow waveguide is presented, which allows weak absorbance features to be studied at the few ppm level (peak-to-rms) after 1,000 scans are co-added in {approx}10 sec. The CAS is meant to work directly with converted CO{sub 2} samples from a Laser Ablation-Catalytic-Combustion (LA CC) micro-sampler to provide {sup 13}C/{sup 12}C ratios of small biological isolates with spatial resolutions {approx}50 {mu}m.

47 OTHER INSTRUMENTATION↗