SU-G-TeP2-01: Can EPID Based Measurement Replace Traditional Daily Output QA On Megavoltage Linac?

Purpose: To investigate the long term stability and viability of using EPID-based daily output QA via in-house and vendor driven protocol, to replace conventional QA tools and improve QA efficiency. Methods: Two Varian TrueBeam machines (TB1&TB2) equipped with electronic portal imaging devices (EPID) were employed in this study. Both machines were calibrated per TG-51 and used clinically since Oct 2014. Daily output measurement for 6/15 MV beams were obtained using SunNuclear DailyQA3 device as part of morning QA. In addition, in-house protocol was implemented for EPID output measurement (10×10 cm fields, 100 MU, 100cm SID, output defined over an ROI of 2×2 cm around central axis). Moreover, the Varian Machine Performance Check (MPC) was used on both machines to measure machine output. The EPID and DailyQA3 based measurements of the relative machine output were compared and cross-correlated with monthly machine output as measured by an A12 Exradin 0.65cc Ion Chamber (IC) serving as ground truth. The results were correlated using Pearson test. Results: The correlations among DailyQA3, in-house EPID and Varian MPC output measurements, with the IC for 6/15 MV were similar for TB1 (0.83–0.95) and TB2 (0.55–0.67). The machine output for the 6/15MV beams on both machines showed a similar trend, namely an increase over time as indicated by all measurements, requiring a machine recalibration after 6 months. This drift is due to a known issue with pressurized monitor chamber which tends to leak over time. MPC failed occasionally but passed when repeated. Conclusion: The results indicate that the use of EPID for daily output measurements has the potential to become a viable and efficient tool for daily routine LINAC QA, thus eliminating weather (T,P) and human setup variability and increasing efficiency of the QA process.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-03: Efficient Data Collection of Continuous 2D and Discrete Relative Dosimetric Data for Annual LINAC QA Using TrueBeam Developer Mode and a 1D Scanning Tank

Purpose: To develop a method to exploit real-time dynamic machine and couch parameter control during linear accelerator (LINAC) beam delivery to facilitate efficient performance of TG-142 suggested, Annual LINAC QA tests. Methods: Varian’s TrueBeam Developer Mode (Varian Medical Systems, Palo Alto, CA) facilitates control of Varian’s TrueBeam LINAC via instructions provided in Extensible Markup Language (XML) files. This allows machine and couch parameters to be varied dynamically, in real-time, during beam delivery. Custom XML files were created to allow for the collection of (1) continuous Tissue Maximum Ratios (TMRs), (2) beam profiles, and (3) continuous output factors using a 1D-scanning tank. TMRs were acquired by orienting an ionization chamber (IC) at isocenter (depth=25cm) and synchronizing a depth scan towards the water surface while lowering the couch at 1mm/s. For beam profiles, the couch was driven laterally and longitudinally while logging IC electrometer readings. Output factors (OFs) where collected by continually varying field sizes (4×4 to 30×30-cm{sup 2}) at a constant speed of 6.66 mm/s. To validate measurements, comparisons were made to data collected using traditional methods (e.g. 1D or 3D tank). Results: All data collecting using the proposed methods agreed with traditionally collected data (TMRs within 1%, OFs within 0.5% and beam profile agreement within 1% / 1mm) while taking less time to collect (factor of approximately 1/10) and with a finer sample resolution. Conclusion: TrueBeam developer mode facilitates collection of continuous data with the same accuracy as traditionally collected data with a finer resolution in less time. Results demonstrate an order of magnitude increase in sampled resolution and an order of magnitude reduction in collection time compared to traditional acquisition methods (e.g. 3D scanning tank). We are currently extending this approach to perform other TG-142 tasks.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-FG-201-01: 18-Month Clinical Experience of a Linac Daily Quality Assurance (QA) Solution Using Only EPID and OBI

Purpose: To describe the clinical use of a Linear Accelerator (Linac) DailyQA system with only EPID and OBI. To assess the reliability over an 18-month period and improve the robustness of this system based on QA failure analysis. Methods: A DailyQA solution utilizing an in-house designed phantom, combined EPID and OBI image acquisitions, and a web-based data analysis and reporting system was commissioned and used in our clinic to measure geometric, dosimetry and imaging components of a Varian Truebeam Linac. During an 18-month period (335 working days), the Daily QA results, including the output constancy, beam flatness and symmetry, uniformity, TPR20/10, MV and KV imaging quality, were collected and analyzed. For output constancy measurement, an independent monthly QA system with an ionization chamber (IC) and annual/incidental TG51 measurements with ADCL IC were performed and cross-compared to Daily QA system. Thorough analyses were performed on the recorded QA failures to evaluate the machine performance, optimize the data analysis algorithm, adjust the tolerance setting and improve the training procedure to prevent future failures. Results: A clinical workflow including beam delivery, data analysis, QA report generation and physics approval was established and optimized to suit daily clinical operation. The output tests over the 335 working day period cross-correlated with the monthly QA system within 1.3% and TG51 results within 1%. QA passed with one attempt on 236 days out of 335 days. Based on the QA failures analysis, the Gamma criteria is revised from (1%, 1mm) to (2%, 1mm) considering both QA accuracy and efficiency. Data analysis algorithm is improved to handle multiple entries for a repeating test. Conclusion: We described our 18-month clinical experience on a novel DailyQA system using only EPID and OBI. The long term data presented demonstrated the system is suitable and reliable for Linac daily QA.

60 APPLIED LIFE SCIENCES↗

Numerical Simulation of Measurements during the Reactor Physical Startup at Unit 3 of Rostov NPP

The results of numerical calculations and measurements of some reactor parameters during the physical startup tests at unit 3 of Rostov NPP are presented. The following parameters are considered: the critical boron acid concentration and the currents from ionization chambers (IC) during the scram system efficiency evaluation. The scram system efficiency was determined using the inverse point kinetics equation with the measured and simulated IC currents. The results of steady-state calculations of relative power distribution and efficiency of the scram system and separate groups of control rods of the control and protection system are also presented. The calculations are performed using several codes, including precision ones.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutrino tomography of the Earth with ORCA detector

Abstract Using PREM as a reference model for the Earth density distribution we investigate the sensitivity of ORCA detector to deviations of the Earth (i) outer core (OC) density, (ii) inner core (IC) density, (iii) total core density, and (iv) mantle density, from their respective PREM densities. The analysis is performed by studying the effects of the Earth matter on the oscillations of atmospheric $$\nu _{\mu }$$ ν μ , $$\nu _e$$ ν e , $${\bar{\nu }}_\mu $$ ν ¯ μ and $${\bar{\nu }}_e$$ ν ¯ e . We present results which illustrate the dependence of the ORCA sensitivity to the OC, IC, core and mantle densities on the type of systematic uncertainties used in the analysis, on the value of the atmospheric neutrino mixing angle $$\theta _{23}$$ θ 23 , on whether the Earth mass constraint is implemented or not, and on the way it is implemented, and on the type – with normal ordering (NO) or inverted ordering (IO) – of the light neutrino mass spectrum. We show, in particular, that in the “most favorable” NO case of implemented Earth mass constraint, “minimal” systematic errors and $$\sin ^2\theta _{23}=0.58$$ sin 2 θ 23 = 0.58 , ORCA can determine, e.g., the OC (mantle) density at $$3\sigma $$ 3 σ C.L. after 10 years of operation with an uncertainty of (− 18%)/+ 15% (of (− 6%)/+ 8%). In the “most disfavorable” NO case of “conservative” systematic errors and $$\sin ^2\theta _{23}=0.42$$ sin 2 θ 23 = 0.42 , the uncertainty on OC (mantle) density reads (− 43%)/+ 39% ((− 17%/+ 20%), while for for $$\sin ^2\theta _{23} = 0.50$$ sin 2 θ 23 = 0.50 and 0.58 it is noticeably smaller: (− 37)%/+ 30% and (− 30%)/+ 24% ((− 13%)/+ 16% and (− 11%/+ 14%)). We find also that the sensitivity of ORCA to the OC, core and mantle densities is significantly worse for IO neutrino mass spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and Properties of Advanced Internal Magnesium Infiltration (AIMI) Processed MgB2 Wires

The development, processing, properties, and formation mechanisms of Advanced Internal Magnesium Infiltration (AIMI) MgB2 wires are discussed against a background of the related and original processes, Internal-Magnesium-Diffusion (IMD) and Magnesium-Reactive-Liquid-Infiltration (Mg-RLI). First reviewed are the formation, properties and applications of Mg-RLI bulks as basis for discussions of Mg-RLI-processed and IMD-processed wires. The transition from Mg-RLI- and IMD- to AIMI wires is explained, and the relative performances of powder-in-tube (PIT), IMD and AIMI wires are summarized in the form of an iso-Je diagram of Jc,nb versus Anb/ATOT in which ATOT, Anb, Jc,nb, and Je are, respectively, the wire s cross-sectional area, the area inside the chemical barrier, the critical current (Ic) normalized to Anb, and Ic normalized to ATOT. After the details of AIMI wire fabrication selection of starting powders, dopants, and reaction heat treatments are introduced the report goes on to describe in detail the development of high performance AIMI wires: layer Jcs, fill factors, Jes, and the effects of wire size, multifilamentarization, doping with C, and co-doping with C and Dy2O3. The two-stage mechanism of layer formation in AIMI wires is discussed: first the reactive infiltration of liquid Mg into a porous B pack, a process that terminates with the formation of a dense MgB2 layer; second the slow diffusion of Mg into any remaining B through that MgB2 layer. The report concludes with a brief general discussion of anisotropy, current percolation, and the Jc field dependence of MgB2 wires.

Collings, Prof Edward William↗

Synthesis of highly water soluble tetrabenzoporphyrins and their application toward photodynamic therapy

Novel tetraaryl-(pyridinium-4-yl)-tetrabenzoporphyrins have been successfully synthesized via a Heck-based sequence reaction. These tetrabenzoporphyrins were substituted with eight pyridyl groups at the fused benzene rings. Methylation of the pyridyl groups with methyl iodide afforded highly water soluble tetrabenzoporphyrins carrying eight ionic groups. The extended π-conjugation broadened and red-shifted the absorption band of these porphyrins to 650–750 nm. Furthermore, these cationic tetrabenzoporphyrins showed non-toxicity in the dark up to 100 uM. High phototoxicity with IC 50 values lower than 18 μM were obtained for these tetrabenzoporphyrins.

DFT calculation photosensitizer↗

Design of a Novel Information System for Semi-Automated Management of Cybersecurity in Industrial Control Systems

There is an urgent need in many critical infrastructure sectors, including the energy sector, for attaining detailed insights into cybersecurity features and compliance with cybersecurity requirements related to their Operational Technology (OT) deployments. Frequent feature changes of OT devices interfere with this need, posing a great risk to customers. One effective way to address this challenge is via a semi-automated cyber-physical security assurance approach, which enables verification and validation of the OT device cybersecurity claims against actual capabilities, both pre- and post-deployment. To realize this approach, this paper presents new methodology and algorithms to automatically identify cybersecurity-related claims expressed in natural language form in ICS device documents. Here, we developed an identification process that employs natural language processing (NLP) techniques with the goal of semi-automated vetting of detected claims against their device implementation. We also present our novel NLP components for verifying feature claims against relevant cybersecurity requirements. The verification pipeline includes components such as automated vendor identification, device document curation, feature claim identification utilizing sentiment analysis for conflict resolution, and reporting of features that are claimed to be supported or indicated as unsupported. Our novel matching engine represents the first automated information system available in the cybersecurity domain that directly aids the generation of ICS compliance reports.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Development of Sensors and Sensing Technology for Hydrogen Fuel Cell Vehicle Applications

One related area of hydrogen fuel cell vehicle (FCV) development that cannot be overlooked is the anticipated requirement for new sensors for both the monitoring and control of the fuel cell's systems and for those devices that will be required for safety. Present day automobiles have dozens of sensors on-board including those for IC engine management/control, sensors for state-of-health monitoring/control of emissions systems, sensors for control of active safety systems, sensors for triggering passive safety systems, and sensors for more mundane tasks such as fluids level monitoring to name the more obvious. The number of sensors continues to grow every few years as a result of safety mandates but also in response to consumer demands for new conveniences and safety features. Some of these devices (e.g. yaw sensors for dynamic stability control systems or tire presure warning RF-based devices) may be used on fuel cell vehicles without any modification. However the use of hydrogen as a fuel will dictate the development of completely new technologies for such requirements as the detection of hydrogen leaks, sensors and systems to continuously monitor hydrogen fuel purity and protect the fuel cell stack from poisoning, and for the important, yet often taken for granted, tasks such as determining the state of charge of the hydrogen fuel storage and delivery system. Two such sensors that rely on different transduction mechanisms will be highlighted in this presentation. The first is an electrochemical device for monitoring hydrogen levels in air. The other technology covered in this work, is an acoustic-based approach to determine the state of charge of a hydride storage system.

08 HYDROGEN↗

Energy Exascale Earth System Model v2.0.2

Second patch release of v2.0.0 Changes since v2.0.1 [Important change] Add and update SSP370 and SSP585 cases, add tests, fix use-case files, Change ocean and sea-ice IC for ARRM60to10. [EAM] allow thetaxx as a CAM_TARGET, enable northamericax4v1pg2_WC14to60E2r3 for AMIP, fix ndrop initialization, allow up to 15 history files. [EAMxx] allow use of readnl [EAM-MMF] allow transient SST case for C++ MMF, remove specific task/thread count for ESMT test, modify the variance transport diagnostic, reorg tests, [HOMME] Allow optional sponge layer. [ELM] add 2 land-atm compsets, update FATES to API 17.0.0, allow FATES sp mode, allow ELM harvest to drive FATES harvest, fix memleaks, reduce test build times, modified parameters for miscanthus and switchgrass based on calibration [MPAS-Ocean] turn on ocean BGC in BGC cases, fix interface locations for 60L PHC grid, add mode spec to conservation check streams, allow oRRS18to6v3 grid to run with JRA, update ocean and sea ice ICs for ARRM60to10 (needed for v2), GPU port of thickness tendency, add CMPASO-JRA1p4, [MPAS framework] Add new reproducible global sum module for MPAS components, Add mostRecentAccessTime attribute to streams [MPAS-landice] Update MALI version and Greenland mesh [MPAS-seaice] add single-cell test case, fix BGC restart, Adds omp critical directives for ice warnings seen on cori. [CIME] Fix component namelist creation bugs when NINST>1, add OpenACC, OpenMP and CXX GPU tests, fix nonBFB tests, stop using config_compilers, reduce ELM test build times with shared executable, update OpenMPI on Chrysalis. fix baseline handling, provenance handling with update to cime6.0.33, also use component-specific config_pes files and add the ones from master [Machine updates] cori modules after maint, Chrysalis to OpenMPI-4.1.3 [run_e3sm] replace default case name and group. [Externals] update SCORPIO to 1.3.2

ECP↗

Variability in Wind Energy Generation across the Contiguous United States

ERA5 provides high-resolution, high-quality hourly wind speeds at 100 m and is a unique resource for quantifying temporal variability in likely wind-derived power production across the United States. Gross capacity factors (CF) in seven independent system operators (ISOs) are estimated using the location and rated power of each wind turbine, a simplified power curve, and ERA5 output from 1979 to 2018. Excluding the California ISO, the marginal probability of a calm (zero power production) is less than 0.1 in any ERA5 grid cell. When a calm occurs, the mean co-occurrence across wind-turbine-containing grid cells ranges from 0.38 to 0.39 for ISOs in the Midwest and central plains [Midcontinent (or Midwest) ISO (MISO), Southwest Power Pool (SPP), and the Electric Reliability Council of Texas (ERCOT) region], increasing to 0.54–0.58 for ISOs in the eastern United States [Pennsylvania–New Jersey–Maryland interconnection (PJM), New York ISO (NYISO), and New England ISO (NEISO)]. Periods with low gross CF have a median duration of ≤6 h, except in California, and are most likely during summer. Additionally, gross CF exhibit highest variance at periods of 1 day in ERCOT and SPP; on synoptic scales in MISO, NEISO, and NYISO; and on interannual time scales in PJM. This implies differences in optimal strategies for ensuring resilience of supply. Theoretical scenarios show adding wind energy capacity near existing wind farms is advantageous even in areas with high existing installed capacity (IC), while expanding into areas with lower IC is more beneficial to reducing ramps and the probability of gross CF falling below 20%. These results emphasize the benefits of large balancing areas and aggregation in reducing wind power variability and the likelihood of wind droughts.

17 WIND ENERGY↗

High-Speed Multiplexed Spatiotemporally Resolved Measurements of Exhaust Gas Recirculation Dynamics in a Multi-Cylinder Engine Using Laser Absorption Spectroscopy

The need for more environmentally friendly and efficient energy conversion is of paramount importance in developing and designing next-generation internal combustion (IC) engines for transportation applications. One effective solution to reducing emissions of mono-nitrogen oxides (NO x ) is exhaust gas recirculation (EGR), which has been widely implemented in modern vehicles. However, cylinder-to-cylinder and cycle-to-cycle variations in the charge-gas uniformity can be a major barrier to optimum EGR implementation on multi-cylinder engines, and can limit performance, stability, and efficiency. Precise knowledge and fine control over the EGR system is thus crucial, particularly for optimizing advanced engine concepts such as reactivity controlled compression ignition (RCCI). An absorption-based laser diagnostic was developed to study spatiotemporal charge-gas distributions in an IC engine intake manifold in real-time. The laser was tuned to an absorption band of carbon dioxide (CO 2 ), a standard exhaust-gas marker, near 2.7 µm. The sensor was capable of probing four separate measurement locations simultaneously, and independently analyzing EGR fraction at speeds of 5 kHz (1.2 crank-angle degree (CAD) at 1 k RPM) or faster with high accuracy. Lastly, the probes were used to study spatiotemporal EGR non-uniformities in the intake manifold and ultimately promote the development of more efficient and higher performance engines.

33 ADVANCED PROPULSION SYSTEMS↗

Investigation of the effects of turbulence modeling on the prediction of compression-ignition combustion unsteadiness

Adverse effects of global warming due to the greenhouse gas emissions is changing the actual paradigm for the use energy resources. In the absence of a mid-term solution for reducing these emissions in transportation, internal combustion (IC) engines are going to coexist in the social spheres in the foreseeable future. Therefore, the study of other IC engine-related problems remains relevant to ensuring the health of the society. In this investigation, a numerical methodology for comprehensive understanding of Noise, Vibration and Harshness in internal combustion engines is proposed. Due to its inherent complexity and lack of awareness, the main objective is to evaluate the impact of the turbulence modeling framework on the in-cylinder acoustic field recreation. Modal decomposition methods have been applied to isolate the coherent flow structures and to analyze how they change with the turbulence approach. Results demonstrate that the choice of the turbulence model is a critical aspect for noise modeling. Unsteady Reynolds-Averaged Navier-Stokes schemes predict a raw estimation of the internal acoustic field with the added value of being computationally less expensive. However, the use of more complex turbulence approaches such us large eddy simulation offers an accurate prediction of the acoustic structures and their cyclic dispersion.

Broatch, A.↗

Evaluating the Rate of Upgrade to Invasive Breast Cancer and/or Ductal Carcinoma In Situ Following a Core Biopsy Diagnosis of Non-classic Lobular Carcinoma In Situ

Background: A diagnosis of non-classic lobular carcinoma in situ (NC-LCIS) encompasses a variety of lesions with poorly characterized natural history. We evaluated upgrade rates and factors associated with upgrade to malignancy following a core biopsy diagnosis of NC-LCIS, and its natural history. Methods: Upon Institutional Review Board approval, pathology databases were searched for NC-LCIS core biopsy diagnoses (carcinoma in situ [CIS], CIS with ductal and lobular features [CIS/DLF], pleomorphic LCIS [P-LCIS], variant LCIS [V-LCIS], LCIS with necrosis). Cases with available core and excision pathology were included, while cases with concurrent ipsilateral invasive carcinoma (IC), ductal carcinoma in situ (DCIS), and/or atypical ductal hyperplasia were excluded. Results: Overall, 121 NC-LCIS cases were identified from 1998 to 2017. We excluded 46 cases with concurrent cancer; 75 patients with 76 NC-LCIS core biopsy diagnoses followed by excision formed our study cohort. Median age was 56 years (range 41–83), and all imaging findings were classified as Breast Imaging Reporting and Data System 4; calcifications were the most common biopsy indication (80%). Excision yielded malignancy in 27 (36%) patients (IC 17, 63%; DCIS alone 10, 37%). We were unable to identify radiologic or pathologic features predictive of upgrade. Of 49 pure NC-LCIS cases, 15 (31%) had mastectomy, 9 (18%) had excision and radiation, and 25 (51%) had excision alone. At a median follow-up of 58 months (range 1–224), 1/25 (4%) patients with excision alone developed ipsilateral DCIS 14 months later. Conclusions: In this series of NC-LCIS, 36% of cases were upgraded, supporting routine excision. We were unable to identify predictors of upgrade. Among 25 patients with pure NC-LCIS, only one patient developed a future ipsilateral cancer. Further study of the natural history of NC-LCIS is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects on Human Non-Small Lung Cancer Cell growth of Cu(II), Au(III) and Re(I) Complexes Containing N-donor Pyridyl Ligands: A Senior Undergraduate Research Project

Hands-on synthetic laboratory experiences are critically important for undergraduate chemistry majors. A senior undergraduate research experience at the College of Wooster is presented in the current work. The inorganic complexes [Cu(phenan) 2 (NO 3 ) 2 ] (1; phenan = phenanthridine) and [Au(phenan)Cl 3 ](2) were prepared by metallation of the phenan ligand in a 1:1 CH 3 OH/CH 2 Cl 2 mixture at room temperature. Complex 1 is a new inorganic coordination compound. The structures were confirmed by X-ray crystallography. Complex 1 reveals a distorted octahedral geometry around the central Cu (II) metal ion. In complex 2, the Au(III) atom exhibits a square planar geometry. In addition, we investigated [Cu(dmeobpy)(H 2 O) 2 ][NO 3 ] 2 (3; dmeobpy = 4,4’-dimethoxy-2,2’-bipyridine), [Cu(bap)(NO 3 ) 2 ](4; bap = 2,6-bis(azaindole)pyridine) and [Re(CO) 3 (dmeobpy)Cl] (5). The cytoxocities of 1-5, phenan, dmeobpy, bap and cisplatin were evaluated against several human non-small cell lung cancer cell lines (NCI-H1975, HCC827, NCI-H460, and NCI-A549). Compound 1 exhibited modest antitumor activity against the HCC827 cell line, with an IC 50 value of 19 µM. Compound 3 exhibits lower cytotoxic activity than 1. Finally, the cytotoxic activity of complex 5 (IC 50 < 11 µM) is significantly greater than 1 and 3 against the H1975 cancer cell line.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel, ;Double-Clamp; Binding Mode for Human Heme Oxygenase-1 Inhibition

The development of heme oxygenase (HO) inhibitors is critical in dissecting and understanding the HO system and for potential therapeutic applications. We have established a program to design and optimize HO inhibitors using structure-activity relationships in conjunction with X-ray crystallographic analyses. One of our previous complex crystal structures revealed a putative secondary hydrophobic binding pocket which could be exploited for a new design strategy by introducing a functional group that would fit into this potential site. To test this hypothesis and gain further insights into the structural basis of inhibitor binding, we have synthesized and characterized 1-(1H-imidazol-1-yl)-4,4-diphenyl-2-butanone (QC-308). Using a carbon monoxide (CO) formation assay on rat spleen microsomes, the compound was found to be {approx}15 times more potent (IC{sub 50} = 0.27{+-}0.07 {mu}M) than its monophenyl analogue, which is already a potent compound in its own right (QC-65; IC{sub 50} = 4.0{+-}1.8 {mu}M). The crystal structure of hHO-1 with QC-308 revealed that the second phenyl group in the western region of the compound is indeed accommodated by a definitive secondary proximal hydrophobic pocket. Thus, the two phenyl moieties are each stabilized by distinct hydrophobic pockets. This 'double-clamp' binding offers additional inhibitor stabilization and provides a new route for improvement of human heme oxygenase inhibitors.

59 BASIC BIOLOGICAL SCIENCES↗

An increased extraction energy booster complex for the Jefferson Lab electron ion collider

The proposed Jefferson Lab Electron Ion Collider (JLE-IC) envisions an ion complex composed of an ion linac, two booster synchrotrons and a collider ring. The evolv-ing design of the JLEIC booster required an increase in the extraction energy of the booster from 8 to 12.1 GeV kinetic energy, necessitating two machines instead of one. The decision was also made to switch to warm magnets, thus increasing the total radius of the 8 GeV booster. With the second booster being the same size as the collider rings. In this work we present the new designs for JLE-IC?s Low Energy Booster (LEB) and High Energy Boost-er (HEB).

Nissen, Edith↗

Research, Development and Demonstration of Micro-CHP System for Residential Applications

ECR International and its joint venture company, Climate Energy, are at the forefront of the effort to deliver residential-scale combined heat and power (Micro-CHP) products to the USA market. Part of this substantial program is focused on the development of a new class of steam expanders that offers the potential for significantly lower costs for small-scale power generation technology. The heart of this technology is the scroll expander, a machine that has revolutionized the HVAC refrigerant compressor industry in the last 15 years. The liquid injected cogeneration (LIC) technology is at the core of the efforts described in this report, and remains an excellent option for low cost Micro-CHP systems. ECR has demonstrated in several prototype appliances that the concept for LIC can be made into a practical product. The continuing challenge is to identify economical scroll machine designs that will meet the performance and endurance requirements needed for a long life appliance application. This report describes the numerous advances made in this endeavor by ECR International. Several important advances are described in this report. Section 4 describes a marketing and economics study that integrates the technical performance of the LIC system with real-world climatic data and economic analysis to assess the practical impact that different factors have on the economic application of Micro-CHP in residential applications. Advances in the development of a working scroll steam expander are discussed in Section 5. A rigorous analytical assessment of the performance of scroll expanders, including the difficult to characterize impact of pocket to pocket flank leakage, is presented in Section 5.1. This is followed with an FEA study of the thermal and pressure induced deflections that would result from the normal operation of an advanced scroll expander. Section 6 describes the different scroll expanders and test fixtures developed during this effort. Another key technical challenge to the development of a long life LIC system is the development of a reliable and efficient steam generator. The steam generator and support equipment development is described in Section 7. Just one year ago, ECR International announced through its joint venture company, Climate Energy, that it was introducing to the USA market a new class of Micro-CHP product using the state-of-the-art Honda MCHP gas fired internal combustion (IC) engine platform. We now have installed Climate Energy Micro-CHP systems in 20 pilot demonstration sites for the 2005/2006 heating season. This breakthrough success with IC engine based systems paves the way for future advanced steam cycle Micro-CHP systems to be introduced.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗