Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Prototype solar heating and cooling systems including potable hot water

Progress is reviewed in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water. The system consisted of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Source record↗

Comminty Geothermal: Planning and Design of a Heating and Cooling System in Framingham, Massachusetts

These reports, plans, and drawings review the achievements of Home Energy Efficiency Team (HEET) and its partners to plan and design a network of interconnected ground-source heat pump systems, or geothermal network, in an area encompassing multiple environmental justice (EJ) neighborhoods in the City of Framingham, MA. The materials provided in this dataset include, a) stakeholder and design best practices, b) study on optimal method to interconnect geothermal loops, c) guidelines for monitoring and metering, d) operations and maintenance plans, e) permitting guidelines and f) 10-day driller tutorial curriculum. These materials can guide the efficient and ethical design of future geothermal networks nationwide. The capacity of the system is estimated at 217 tons and is designed to provide 100% of heating and cooling needs for the buildings connected to the loop. In this project, 80 boreholes are used as the main thermal resources, the distribution system (or loop) consists of 0.61 miles of an 8-inch single-pipe at ambient temperature, with the capacity to connect 44 buildings, including 13 apartment buildings from the Framingham Housing Authority, one transitional home, one school building and 29 single family homes. While Framingham already has a geothermal network loop that is currently in the commissioning stage, our proposed project is unique because it is the first utility-led expansion loop (2nd loop) project that will connect to an adjacent existing geothermal loop (1st loop) in a pre-existing neighborhood. Both the 1st and 2nd loops are being installed, owned and operated by Eversource Energy, the utility Deployment Partner.

15 GEOTHERMAL ENERGY↗

AUXILIARY FEEDWATER REHEATING TO MITIGATE PRIMARY AND SECONDARY SIDE THERMAL STRESSORS

A consequence of operating steam cycles under time varying loads, is the variability of the feedwater temperature entering the bottom of the steam generators. This variability is a direct result of changes in turbine impulse pressure and subsequently turbine tap pressures in response to the load changes, with a reduction in feed temperature during periods of low turbine demand. These fluctuations over time will increase thermal cycling and threaten the integrity of the tube bundle as well as other components in the feed system. Sensible heat, TES systems have been shown to be an effective load management strategy allowing nuclear reactor systems to operate at effectively 100% full power while storing excess thermal energy for recovery later. A byproduct of the TES system is the availability of large amounts of low grade waste heat that can be used for ancillary applications, including auxiliary feed heating during periods of low turbine demand. The addition of an auxiliary feed heater at the end of the traditional feed train can minimize feed temperature variations during periods of low turbine demand, reducing the effects of thermal cycling and increasing overall thermodynamic efficiency. This paper discusses the design, operation and control strategies for an auxiliary feed water system as an integral component of a coupled Thermal Energy Storage system and Integral Pressurized Water Reactor. The impact on system performance, particularly as it affects reactor dynamic response and reductions in thermal cycling will be addressed. In addition to the improved thermal efficiency, a benefit of this approach is the relocation of thermal stressors from the reactor coolant system to more easily managed Balance of Plant systems

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Conceptual Machine Learning Strategy for Maintenance of Molten Salt Heat Exchanger

This report addresses the requirements of Milestone M3.2 Define maintenance scenarios and benchmarks. Development of digital twins (DT) for molten salt reactor (MSR) components is crucial for reducing operating and maintenance costs (O&M) and ensuring commercial viability of these reactors. Our focus is on development of DT for MSR primary system heat exchanger (HX), a critical component, the fault in which can reduce operating efficiency and force reactor shutdown. We are investigating feasibility of a conceptual DT of HX consisting of internal distributed temperature sensing with fiber optics and machine learning (ML) algorithms to detect and localize faults.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technology Solutions Case Study: Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast, Devens and Easthampton, Massachusetts

Transformations, Inc., has extensive experience building high-performance homes - production and custom - in a variety of Massachusetts locations and uses mini-split heat pumps (MSHPs) for space conditioning in most of its homes. The use of MSHPs for simplified space-conditioning distribution provides significant first-cost savings, which offsets the increased investment in the building enclosure. In this project, the U.S. Department of Energy Building America team Building Science Corporation evaluated the long-term performance of MSHPs in 8 homes during a period of 3 years. The work examined electrical use of MSHPs, distributions of interior temperatures and humidity when using simplified (two-point) heating systems in high-performance housing, and the impact of open-door/closed-door status on temperature distributions.

BSC↗

Helicon edge heating in Proto-MPEX: Azimuthally resolved RF modeling

The Material Plasma Exposure eXperiment (MPEX) is a linear device under construction at ORNL. MPEX employs a variety of heating systems, including a helicon antenna, which is the subject of this work. Lacking a resonant absorption mechanism, as tokamaks have, modeling the RF power absorption in such antennas requires detailed consideration of cold collisional physics. Previous modeling of the heating in this antenna was done exclusively in 2D, assuming axisymmetry and a single azimuthal mode number m = 1⁠. In this study, we introduce a fully 3D model. By including the full 3D physics, with its self-consistent geometry-imposed azimuthal spectrum, we are able to reproduce the experimentally observed transition from edge heating to core heating.

Tierens, Wouter [Oak Ridge National Laboratory (OR↗

Turning Gas into Greens

Scientists from Cook College, Rutgers University, and Stevens Institute of Technology conducted studies to create an experimental greenhouse that uses methane from decomposing trash to fuel a system that makes food. Biogasses created by the anaerobically decomposing trash are necessary to fulfill the energy needs of this revolutionary greenhouse. The primary emission, methane, is piped to the greenhouse boiler and used to fuel the hot water heating system. Thus far, the use of biogas has drastically reduced the operating costs of the greenhouse, eliminating the need for non-renewable fuels. The biogas will also generate electricity for the greenhouse in the near future. The plants are irrigated with recycled plant nutrients such as nitrogen, phosphorus, potassium, calcium, and magnesium. These nutrients are delivered through hydroponics, the cultivation of plants in a nutrient solution rather than in soil. High-pressure sodium lamps augment the natural light, thereby boosting production and reducing cropping time. A total of 16 hours of light are provided to the crop each day, year-round. It only takes about 90 days for a seed to germinate and produce a tomato harvest. Not only is the food produced faster, the manual labor needed for the upkeep of the plants is also drastically reduced.

Source record↗

System design and installation for RS600 programmable control system for solar heating and cooling

Procedures for installing, operating, and maintaining a programmable control system which utilizes a F8 microprocessor to perform all timing, control, and calculation functions in order to customize system performance to meet individual requirements for solar heating, combined heating and cooling, and/or hot water systems are described. The manual discusses user configuration and options, displays, theory of operation, trouble-shooting procedures, and warranty and assistance. Wiring lists, parts lists, drawings, and diagrams are included.

Source record↗

Three dimensional numerical investigation of gravitational and solutal effects in a cylindrical cell

Three-dimensional numerical computations of natural convection in a cylindrical ampoule (L/R = 4) are presented for a Ga-doped Ge melt. The ampoule is maintained at isothermal end conditions, and the g vector is oriented at an angle gamma with the cylinder axis. Detailed velocity, temperature, and concentration field distributions are presented for different gravity levels and a range of inclination angles (gamma between 0 and 180 deg). For terrestrial conditions, complex, multicellular flow is found to occur for gamma between 0 and 180 deg. The strong convection results in significant isotherm distortions and enhanced heat transfer. As the gravity level is reduced to 0.001 g(0), the overall convection strength decays but the 3D multicellular flow persists, causing appreciable mass transfer. For a further reduction in the gravity level to 0.00001 g(0), the system thermo/solutal characteristics are close to a purely diffusive behavior. Flow and thermal and solutal distributions are presented in the principal, orthogonal, and cross sectional planes, and the average system heat and mass transfer are calculated.

Ramachandran, N.↗

Technology Solutions for New and Existing Homes Case Study: Addressing Multifamily Piping Losses with Solar Hot Water

Sun Light & Power, a San Francisco Bay Area solar design-build contractor, teamed with the U.S. Department of Energy’s Building America partner the Alliance for Residential Building Innovation (ARBI) to study this heat-loss issue. The team added three-way valves to the solar water heating systems for two 40-unit multifamily buildings. In these systems, when the stored solar hot water is warmer than the recirculated hot water returning from the buildings, the valves divert the returning water to the solar storage tank instead of the water heater. This strategy allows solar-generated heat to be applied to recirculation heat loss in addition to heating water that is consumed by fixtures and appliances.

ARBI↗

5-kWe Free-piston Stirling Engine Convertor

The high reliability, long life, and efficient operation of Free-Piston Stirling Engines (FPSEs) make them an attractive power system to meet future space power requirements with less mass, better efficiency, and less total heat exchanger area than other power convertor options. FPSEs are also flexible in configuration as they can be coupled with many potential heat sources and various heat input systems, heat rejection systems, and power management and distribution systems. Development of a 5-kWe Stirling Convertor Assembly (SCA) is underway to demonstrate the viability of an FPSE for space power. The design is a scaled-down version of the successful 12.5-kWe Component Test Power Converter (CTPC) developed under NAS3-25463. The ultimate efficiency target is 25% overall convertor efficiency (electrical power out over heat in). For the single cylinder prototype now in development, cost and time constraints required use of economical and readily available materials (steel versus beryllium) and components (a commercially available linear alternator) and thus lower efficiency. The working gas is helium at 150 bar mean pressure. The design consists of a displacer suspended on internally pumped gas bearings and a power piston/alternator supported on flexures. Non-contacting clearance seals are used between internal volumes. Heat to and from the prototype convertor is done via pumped liquid loops passing through shell and tube heat exchangers. The preliminary and detail designs of the convertor, controller, and support systems (heating loop, cooling loop, and helium supply system) are complete and all hardware is on order. Assembly and test of the prototype at Foster- Miller is planned for early 2008, when work will focus on characterizing convertor dynamics and steady-state operation to determine maximum power output and system efficiency. The device will then be delivered to Auburn University where assessments will include start-up and shutdown characterization and transient response to temperature and load variations. Future activities may include testing at NASA GRC.

Chapman, Peter A.↗

A Procedure for the Design of Air-Heated Ice-Prevention Systems

A procedure proposed for use in the design of air-heated systems for the continuous prevention of ice formation on airplane components is set forth. Required heat-transfer and air-pressure-loss equations are presented, and methods of selecting appropriate meteorological conditions for flight over specified geographical areas and for the calculation of water-drop-impingement characteristics are suggested. In order to facilitate the design, a simple electrical analogue was devised which solves the complex heat-transfer relationships existing in the thermal-system analysis. The analogue is described and an illustration of its application to design is given.

Neel, C. B.↗

Machine Learning Classification of Molten Salt Heat Exchanger Channel Plugging using Synthetic Data

This report addresses the requirements of Milestone M3.4 AI capability to identify and predict maintenance events. Development of digital twins (DT) for molten salt reactor (MSR) components is crucial for reducing operating and maintenance costs (O&M) and ensuring commercial viability of these reactors. Our focus is on development of DT for MSR primary system heat exchanger (HX), a critical component, the fault in which can reduce operating efficiency and force reactor shutdown. We are investigating the feasibility of a conceptual DT of HX consisting of internal distributed temperature sensing with fiber optics and machine learning (ML) algorithms to detect and localize faults. To determine the optimal approach to detection and localization of channel plugging, we benchmark seven different ML models: Logistic Regression, K-Nearest Neighbors (KNN), Gaussian Naïve Bayes, Support Vector Machines (SVM), Decision Tree Classifier, Random Forest Tree Classifier, and Feed-Forward Neural Network. ML algorithms are benchmarked using synthetic HX plugging data generated with computational fluid dynamics COMSOL software, with added brown noise to represent experimental noise. We show that the best performance is obtained with the Decision Tree classifier.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Observation of alpha-particles in recent D–T experiments on JET

The fusion reaction between deuterium and tritium, D(T,n) 4 He is the main source of energy in future thermonuclear reactors. Alpha-particles ( 4 He-ions) born with an average energy of 3.5 MeV transferring energy to the thermal plasma during their slowing down, should provide the self-sustained D–T plasma burn. The adequate confinement of α-particles is essential to provide efficient heating of the bulk plasma and steady burning of a reactor plasma. That is why the fusion-born α-particle studies have been a priority task in the second D–T experiments (DTE2) on the Joint European Torus (JET) to understand the main mechanisms of their slowing down, redistribution and losses and to develop optimal plasma scenarios. JET with Be-wall and W-divertor, enhanced auxiliary heating systems and improved energetic-particle diagnostic capabilities, producing significant population of α-particles, provided the possibility for comprehensive studying of the α-particle behaviour. Selected results of the confined and lost α-particle measurements, evidence of α-particle self-heating and assessments of the fusion performance are presented in this paper giving an opportunity for further modelling and extrapolation to the International Thermonuclear Experimental Reactor and burning plasma reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Experimental Study of the Operating Temperature in a Loop Heat Pipe with Two Evaporators and Two Condensers

This paper presents a comprehensive experimental study of the loop operating temperature in a loop heat pipe (LHP) which has two parallel evaporators and two parallel condensers. In a single evaporator LHP, it is well known that the loop operating temperature is a function of the heat load, the sink temperature and the ambient temperature. The objective of the present study emphasizes on the stability of the loop operating temperature and parameters that affects the loop operation. Tests results show that the loop operating temperature is a function of the total system heat load, sink temperature, ambient temperature, and beat load distribution between the two evaporators. Under most conditions, only one compensation chamber (CC) contains two-phase fluid and controls the loop operating temperature, and the other CC is completely filled with liquid. Moreover, as the test condition changes, control of the loop operating temperature often shifted from one CC to another. In spite of complex interactions between various components, the test loop has demonstrated very robust operation even during fast transients.

Ku, Jentung↗

Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts (Fact Sheet)

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent). The original ventilation design for the project was provided by a local engineer and consisted of a single large heat recovery ventilator (HRV) located in a mechanical room in the basement with a centralized duct system providing supply air to the main living space and exhausting stale air from the single bathroom in each apartment. This design was deemed to be far too costly to install and operate for several reasons: the large central HRV was oversized and the specified flows to each apartment were much higher than the ASHRAE 62.2 rate; an extensive system of ductwork, smoke and fire dampers, and duct chases were specified; ductwork required a significant area of dropped ceilings; and the system lacked individual ventilation control in the apartments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas

A solar heating system designed to supply a major portion of the space and water heating requirements for a restaurant is described. The restaurant has a floor space of approximately 4,650 square feet and requires approximate 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10 to the 6th power Btu/Yr (specified) building heating and hot water heating.

Source record↗