Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Neutron Detection Gamma Ray Sensitivity Criteria

The shortage of 3He has triggered the search for effective alternative neutron detection technologies for national security and safeguards applications. Any new detection technology must satisfy two basic criteria: (1) it must meet a neutron detection efficiency requirement, and (2) it must be insensitive to gamma-ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this paper to define measureable gamma ray sensitivity criteria for neutron detectors. Quantitative requirements are specified for: intrinsic gamma ray detection efficiency and gamma ray absolute rejection. The ratio GARRn is defined, and it is proposed that the requirement for neutron detection be 0.9 < GARRn < 1.1 at a 10 mR/h exposure rate. An example of results from a 3He based neutron detector are provided showing that this technology can meet the stated requirements. Results from tests of some alternative technologies are also reported.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uranium Removal from Seawater by Means of Polyamide 6 Fibers Directly Grafted with Diallyl Oxalate through a Single-Step, Solvent-Free Irradiation Process

In order to test the effectiveness of oxalate-based polymeric adsorbents in the recovery of uranium from seawater, diallyl oxalate (DAOx) was grafted onto nylon 6 fabrics by exposing the fabric, immersed in pure liquid DAOx or in a surfactant-stabilized dispersion of DAOx in water, to electron beam or gamma radiation. Following drying and weighing to determine the degree of grafting (DoG), the presence of oxalate in the fabrics was verified using XPS. Zeta potential measurements showed the fabric surfaces to be negatively charged. The fabrics were tested by rotating them for 7 days in a rotary agitator with actual seawater spiked with 0.2 or 1.0 mg∙L -1 uranium. The fraction of uranium in the solution which was removed due to uptake on the fabrics was found to rise with increasing DoG at both uranium concentrations. EDS measurements were used to map the distribution of adsorbed uranium on the polymeric fibers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Magnetic Particle-Based Immunoassay of Phosphorylated p53 Using Protein-Cage Templated Lead Phosphate and Carbon Nanospheres for Signal Amplification

Phosphorylated p53 at serin 15 (phospho-p53-15) is a potential biomarker of Gamma-radiation exposure. In this paper, we described a new magnetic particles (MPs)-based electrochemical immunoassay of human phospho-p53-15 using carbon nanospheres (CNS) and protein-cage templated lead phosphate nanoparticles for signal amplification. Greatly enhanced sensitivity was achieved by three aspects: 1) The protein-cage nanoparticle (PCN) and p53-15 signal antibody (p53-15 Ab2) are linked to CNS (PCNof each apoferritin; 3) MPs capture a large amount of primary antibodies. Using apoferritin templated metallic phosphate instead of enzyme as label has the advantage of eliminating the addition of mediator or immunoreagents and thus makes the immunoassay system simpler. The subsequent stripping voltammetric analysis of the released lead ions were detected on a disposable screen printed electrode. The response current was proportional to the phospho-p53-15 concentration in the range of 0.02 to 20 ng mL-1 with detection limit of 0.01 ng mL-1. This method shows a good stability, reproducibility and recovery.

Environmental Molecular Sciences Laboratory↗

Gamma-radiolytic stability of new methylated TODGA derivatives for minor actinide recycling

The stability against gamma radiation of MeTODGA (methyl tetraoctyldiglycolamide) and Me2TODGA (dimethyl tetraoctyldiglycolamide), derivatives from the well-known extractant TODGA (N,N,N',N';-tetraoctyldiglycolamide), were studied and compared. Solutions of MeTODGA and Me2TODGA in alkane diluents were subjected to 60Co γ-irradiation in the presence and absence of nitric acid and analyzed using LC-MS to determine their rates of radiolytic concentration decrease, as well as to identify radiolysis products. The results of product identification from three different laboratories are compared and found to be in good agreement. The diglycolamide (DGA) concentrations decreased exponentially with increasing absorbed dose. The MeTODGA degradation rate constants (dose constants) were uninfluenced by the presence of nitric acid, but the acid increased the rate of degradation for Me2TODGA. The degradation products formed by irradiation are also initially produced in greater amounts in acid-contacted solution, but products may also be degraded by continued radiolysis. As a result, the identified radiolysis products suggest that the weakest bonds are those in the diglycolamide center of these molecules.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comprehensive dosimetry for seven exposure sources at the earliest US uranium processing facility

Mallinckrodt Chemical Works (MCW) was the earliest uranium processing facility in the United States, beginning in 1942. The 2,514 workers included in the epidemiologic study were exposed to external gamma radiation, medical x-rays, internal radiation from intakes of pitchblende ore and its extracted radionuclides (mainly uranium isotopes and radium-226), and ambient levels of radon and its progeny [1].

Ellis, Elizabeth↗

Gamma ray spectroscopy at high energy and high time resolution at JET

In fusion plasmas gamma ray emission is caused by reactions of fast particles, such as fusion alpha particles, with impurities. Gamma ray spectroscopy at JET has provided valuable diagnostic information on fast fuel as well as fusion product ions. Improvements of these measurements are needed to fully exploit the flux increase provided by future high power experiments at JET and ITER. Limiting aspects are, for instance, the count rate capability due to a high neutron/gamma background combined with slow detector response and a modest energy resolution due to the low light yield of the scintillators. This paper describes the solutions developed for achieving higher energy resolution, signal to background, and time resolution. The detector design is described based on the new BrLa{sub 3} scintillator crystal. The paper will focus on hardware development, including a photomultiplier tube capable of stable operation at counting rate as high as 1 MHz, the magnetic shielding, and the fast digital data acquisition system.

36 MATERIALS SCIENCE↗

Search for VHE {gamma}-ray emission in the vicinity of selected pulsars of the Northern Sky with VERITAS

It is generally believed that pulsars dissipate their rotational energy through powerful winds of relativistic particles. Confinement of these winds leads to the formation of luminous pulsar wind nebulae (PWNe) seen across the electromagnetic spectrum in synchrotron and inverse Compton emission. Recently, many new detections have been produced at the highest energies by Very High Energy (VHE){gamma}-ray observations, identifying PWNe as among the most common sources of galactic VHE {gamma}-ray emission. We report here on the preliminary results of a search for VHE {gamma}-ray emission towards a selection of energetic and/or close pulsars in the Northern hemisphere in the first year of operations of the full VERITAS array.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-dependent absorption of very high-energy gamma-rays from the Galactic center by pair-production

Very high energy (VHE) gamma-rays have been detected from the direction of the Galactic center. The H.E.S.S. Cherenkov telescopes have located this {gamma}-ray source with a preliminary position uncertainty of 8.5'' per axis (6'' statistic+6'' sytematic per axis). Within the uncertainty region several possible counterpart candidates exist: the Super Massive Black Hole Sgr A*, the Pulsar Wind Nebula candidate G359.95-0.04, the Low Mass X-Ray Binary-system J174540.0-290031, the stellar cluster IRS 13, as well as self-annihilating dark matter. It is experimentally very challenging to further improve the positional accuracy in this energy range and therefore, it may not be possible to clearly associate one of the counterpart candidates with the VHE-source. Here, we present a new method to investigate a possible link of the VHE-source with the near environment of Sgr A*(within approximately 1000 Schwarzschild radii). This method uses the time- and energy-dependent effect of absorption of VHE {gamma}-rays by pair-production (in the following named pair-eclipse) with low-energy photons of stars closely orbiting the SMBH Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a High-Average-Power Compton Gamma Source for Lepton Colliders

Gamma-({gamma}{sup -}) ray beams of high average power and peak brightness are of demand for a number of applications in high-energy physics, material processing, medicine, etc. One of such examples is gamma conversion into polarized positrons and muons that is under consideration for projected lepton colliders. A {gamma}-source based on the Compton backscattering from the relativistic electron beam is a promising candidate for this application. Our approach to the high-repetition {gamma}-source assumes placing the Compton interaction point inside a CO{sub 2} laser cavity. A laser pulse interacts with periodical electron bunches on each round-trip inside the laser cavity producing the corresponding train of {gamma}-pulses. The round-trip optical losses can be compensated by amplification in the active laser medium. The major challenge for this approach is in maintaining stable amplification rate for a picosecond CO{sub 2}-laser pulse during multiple resonator round-trips without significant deterioration of its temporal and transverse profiles. Addressing this task, we elaborated on a computer code that allows identifying the directions and priorities in the development of such a multi-pass picosecond CO{sub 2} laser. Proof-of-principle experiments help to verify the model and show the viability of the concept. In these tests we demonstrated extended trains of picosecond CO{sub 2} laser pulses circulating inside the cavity that incorporates the Compton interaction point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards combining in-beam {gamma}-ray and conversion electron spectroscopy

The SAGE spectrometer will combine a segmented Si-detector with a Ge-detector array aiming to take the simultaneous in-beam {gamma}-ray and conversion electron spectroscopy to the next level. It will be coupled with the GREAT focal plane spectrometer and the RITU gas-filled recoil separator at the accelerator laboratory of the University of Jyvaeskylae, Finland. Its high efficiency and resolution will open the door to a new era of complete spectroscopy directed, amongst others, at the study of superheavy nuclei aiming to investigate the properties of the next spherical proton shell above Z = 82.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel LaBr{sub 3} based {gamma}-ray detection array for use at RIBF

With the RI Beam Factory at RIKEN being on the cusp to deliver the world's most intense radioactive ion beams at relativistic energies, a new {gamma}-ray detection array has been proposed to exploit the new experimental possibilities coming along with it. The material LaBr{sub 3}(Ce) possesses an unprecedentedly high intrinsic energy resolution for scintillators of {approx_equal}2% at 1.3 MeV and is therefore well suited for high-resolution in-beam {gamma}-ray experiments at relativistic energies. To minimize Doppler effects, the total array will comprise of up to one thousand individual crystals. It is intended to place the array around the secondary target area of the large acceptance fragment separator BigRIPS and use it either in a stand-alone mode or in addition to a reconfigured DALI2 array. Alternatively, the array will be used in a different configuration for stopped beam, delayed {gamma}-ray decay experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The new PGAA installation at the FRM II

At the new research reactor FRM II in Garching near Munich the beam guide with the highest cold neutron flux is dedicated to Prompt Gamma-ray Activation Analysis (PGAA) and related neutron capture experiments. We have designed a partially ballistic form of the neutron guide with the aim of concentrating the cold neutrons at the target position of the PGAA experiment. The cold neutron flux with a mean energy of only 1.83 meV was measured about 10.5 cm far from the second exit window and reached intensity of 1.7x10{sup 10} n/cm{sup 2} s at a 2 mmx2 mm gold foil. The PGAA installation is now prepared for three different kinds of measurements--standard PGAA, Neutron Tomography of small samples and position sensitive PGAA, or PGAI for short. We have also measured {gamma}{gamma} coincidences in {sup 77}Ge. In this paper, we want to introduce the PGAA facility, show the diversity of the recently performed experiments and discuss further possibilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The New Position Sensitive Triple Cluster Detector For AGATA

The first triple cluster detector was successfully assembled for the next generation high-resolution gamma-ray spectrometer: the Advanced Gamma Tracking Array AGATA. The core part of the detector consists of three encapsulated, 36-fold segmented, high-purity germanium detectors (HPGe) which are operated in a common cryostat. All 111 energy channels are equipped with cold FETs. They provide best energy resolution of core and segment signals. The observable energy range of the Ge detectors was extended up to 100 MeV by applying a time over threshold technique with the newly developed AGATA preamplifiers. Energy resolution for high energetic {gamma}-rays above 10 MeV is measured to be comparable with values obtained with the standard pulse height technique. Detailed cross-talk investigations were performed in order to improve position dependent pulse shape information. For the Ge detectors and its analog preamplifier circuitry a low cross-talk level was determined which compares well with the expected calculated contributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism for low-etching resistance and surface roughness of ArF photoresist during plasma irradiation

ArF excimer laser lithography was introduced to fabricate nanometer-scale devices and uses chemically amplified photoresist polymers including photoacid generators (PAGs). Because plasma-etching processes cause serious problems related to the use of ArF photoresists, such as line-edge roughness and low etching selectivity, we have to understand the interaction between plasma and ArF photoresist polymers. Investigating the effects of surface temperature and the irradiation species from plasma, we have found that ion irradiation by itself did not drastically increase the roughness or etching rate of ArF photoresist films unless it was combined with ultraviolet/vacuum ultraviolet (UV/VUV) photon irradiation. The structures of ArF photoresist polymers were largely unchanged by ion irradiation alone but were destroyed by combinations of ion and UV/VUV-photon irradiation. Our results suggested that PAG-mediated deprotection induced by UV/VUV-photon irradiation was amplified at surface temperatures above 100 deg. C. The etching rate and surface roughness of plasma-etched ArF photoresists are affected by the irradiation species and surface temperature during plasma etching. UV/VUV-photon irradiation plays a particularly important role in the interaction between plasma and ArF photoresist polymers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma-Ray Tracking Detectors: Physics Opportunities and Status of GRETINA/GRETA

Gamma-ray tracking detectors using highly segmented germanium detectors will give higher efficiency, better peak-to-total ratio and much higher position resolution than current generation of detectors. Particularly, the capability of reconstructing the position of the interaction with millimeters resolution is needed to fully exploit the physics opportunities provided by the next generation radioactive beam facilities. This paper presents the basic concepts of tracking, examples of physics opportunities, and the status of the project GRETA/GRETINA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing inertial confinement fusion gamma ray physics (invited)

The gamma reaction history (GRH) diagnostic is a multichannel, time-resolved, energy-thresholded {gamma}-ray spectrometer that provides a high-bandwidth, direct-measurement of fusion reaction history in inertial confinement fusion implosion experiments. 16.75 MeV deuterium+tritium (DT) fusion {gamma}-rays, with a branching ratio of the order of 10{sup -5}{gamma}/(14 MeV n), are detected to determine fundamental burn parameters, such as nuclear bang time and burn width, critical to achieving ignition at the National Ignition Facility. During the tritium/hydrogen/deuterium ignition tuning campaign, an additional {gamma}-ray line at 19.8 MeV, produced by hydrogen+tritium fusion with a branching ratio of unity, will increase the available {gamma}-ray signal and may allow measurement of reacting fuel composition or ion temperature. Ablator areal density measurements with the GRH are also made possible by detection of 4.43 MeV {gamma}-rays produced by inelastic scatter of DT fusion neutrons on {sup 12}C nuclei in the ablating plastic capsule material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digital method for separation and reconstruction of pile-up events in germanium detectors

The problem of pulse pile-up is very often encountered in precise measurements of {gamma}-rays using germanium detectors. The standard method of treating the pile-up events is to identify and reject them using an appropriate electronic system. Digital acquisition techniques now allow the recording of waveforms of pile-up events that can be analyzed and the contributing single pulses recovered, rather than simply tolerating the losses associated with pile-up. In this paper, a method for the off-line digital processing of pile-up events from germanium detectors is demonstrated. The method is based on an appropriate fitting of the detector signals, shaped with a suitable digital pulse shaper. It is shown that the method is able to recover the pile-up events with good accuracy even when the constituent signals are in close proximity. The method is very useful for {gamma}-ray spectroscopy in nuclear physics experiments, where the low intensity signals can be lost due to the pile-up in a high-rate environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗