Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fracture control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Review—The Lithiation/Delithiation Behavior of Si-Based Electrodes: A Connection between Electrochemistry and Mechanics

Silicon is a promising alternative anode material to graphite because of its high gravimetric and volumetric energy densities. However, severe capacity fading is observed in Si electrodes, and it is a result of mechanical changes of Si, such as volume changes, stress or fracture. Furthermore, these mechanical behaviors are strongly coupled with the electrochemistry of the Li-Si alloying reaction in Si-based electrodes, including both thermodynamics and kinetics. Therefore, the electrochemical properties of Si-based electrodes are strongly dependent on the control of the mechanics of Si during lithiation/delithiation. As such, it is very important to understand the correlation between electrochemistry and mechanics. Here, we review lithiation/delithiation behaviors of various types of Si-based electrodes, applying a fundamental understanding of electrochemistry and mechanics and the correlation between them.

25 ENERGY STORAGE↗

Assessing the Geomechanical Response of CO 2 Disposal in Flood Basalt Reservoirs

In this work, we complete a multi-scale investigation of the physical processes governing geologic CO 2 sequestration in basalt reservoirs. This work integrates (i) laboratory measurements of relative permeability in a basalt fracture, (ii) theoretical modeling to understand how relative permeability uncertainty affects geomechanical performance attributes of basalt reservoirs, (iii) outcrop-scale simulation to identify the characteristics of vertical CO 2 flow in a basalt fracture network, and (iv) regional-scale assessment of permeability architecture in the Columbia River Basalt Group (CRBG). These individual studies are combined into a site-scale stochastic model of geologic CO 2 sequestration in the Columbia River Plateau, which shows how bulk and relative permeability variability affects geomechanical reservoir integrity and storage capacity of flood basalt reservoirs. This project resulted in a novel laboratory technique that combines X-ray CT and micro-PET scanning to calculate the relative permeability curves for a horizontal fracture in basalt. We also discovered that permeability on the Columbia River Plateau exhibits directionally-dependent spatial correlation, which our analysis suggests is a result of loading-induced subsidence. This analysis further discovered that permeability in the CRBG may increase at depth due to bending moment stresses. In the context of CO 2 sequestration, this result implies that storage capacity and injectivity may actually increase at depths beyond ~1 km. Our outcrop-scale investigation found that buoyant, free-phase CO 2 tends to accumulate at fracture intersections, which inhibits vertical flow over 10+ year timescales and may facilitate both physical and chemical trapping as fluid mobility decreases. At the site-scale, we find that in flood basalt reservoirs the spatial configuration of reservoir permeability exhibits substantial control on CO 2 injectivity. We utilized known borehole geology from the Wallula Basalt Sequestration Pilot Project to develop 50 equally probable permeability configurations and found that a single injection well operating at 95% of the borehole breakout pressure can deliver 0.12 to 2.0 million metric tons of CO 2 per year (MMT CO 2 per year). This maximum injection rate can support a 1,000 MW gas-fired power plant with a single injection well.

58 GEOSCIENCES↗

Martian surface and crust - Review and synthesis.

The nature of the classical marking of Mars are studied on the basis of Mariner 9 data and some earlier data. The analysis leads to a model of the Martian crust. Evidence for petrologic distinctions between surface materials in dark and light regions is obtained. It is shown that the classical markings are a complex result of three factors: (1) availability of two types of rock material transportable by wind, (2) topographic control of deposition, and (3) prevailing winds producing quasi-permanent preferential deposition patterns. The crust, especially in the Tharsis region, bears strong evidence of mantle-induced uplift of a type existing on earth. Such uplifts have obliterated ancient craters, caused fractures and graben systems, and have resulted in intense volcanism.

Hartmann, W. K.↗

Influence of precracked specimen configuration and starting stress intensity on the stress corrosion cracking of 4340 steel

Since the pioneer work of Brown (1966), precracked specimens and related fracture mechanics analyses have been extensively used to study stress corrosion cracking. Certain questions arose in connection with initial attempts to prepare standardized recommended practices by ASTM Committee G-1 on Corrosion of Metals. These questions were related to adequacy of test control as it pertains to acceptable limits of variability, and to validity of expressions for stress intensity and crack-surface displacements for both specimen configurations. An interlaboratory test program, was, therefore, planned with the objective to examine the validity of KIscc testing for selected specimen configurations, materials,and environmental systems. The results reported in the present paper include details of a single laboratory test program. The program was conducted to determine if the threshold value of stress intensity for onset and arrest of stress corrosion cracking was independent for the two specimen configurations examined.

Lisagor, W. B.↗

Biaxial fatigue properties of thin-walled composite tubes

A testing method for obtaining fatigue and fracture data under biaxial loading and for negative R-ratios is described. Thin-walled tubes of 1-in. outer nominal diameter with a tapered grip section were tested in an Axial-Torsion Servohydraulic Testing Machine with a 463 Data Control Processor at frequencies below 10 Hz up to the 1-million cycle range. Room temperature, uniaxial constant amplitude fatigue data for high temperature cure graphite-epoxy material are presented at R = -0.4 for a (+, - 5 deg) fiber orientation. The fatigue curve is almost horizontal. Tests on (+, - 5 deg) 'SP-328' resulted in failures which predominantly originated in the grip section. Presently, a new specimen design is being tested intended to eliminate cracking in the grip section. Biaxial in-phase loading of (0/+, - 45) tubes of Fiberite graphite-epoxy resulted in much steeper fatigue curves than observed under uniaxial loading.

Krempl, E.↗

Adhesive evaluation of water-soluble LARC-TPI

The water-soluble polyimide, identified as TPI(MTC)/H2O, was evaluated as a high temperature thermoplastic adhesive for bonding Ti-6Al-4V and comparing those results primarily with results reported in earlier work with the polyamic-acid/diglyme material. The lap shear strength test was the primary test performed to evaluate the adhesive before (controls) and after thermal exposure in air at 204 C for up to 5000 hours and after a 72 hour water-boil exposure. Lap shear strengths were determined at RT, 177, 204, and 232 C. The adhesive was also characterized after fracture by determining the glass transition temperature as well as defining the mode of failure by visual observation. In general, the results indicate that the TPI(MTC)/H2O retains high lap shear strengths after thermal exposure but had reduced strengths after the water-boil exposure. All failures were cohesive. The TPI(MTC)/H2O compared very well with previous data reported for the standard polyamic-acid/diglyme LARC-TPI results, and therefore, shows promise as a water-soluble adhesive for use in various applications.

Progar, Donald J.↗

Polymer precursors for ceramic composites

The fiber composite approach to reinforced ceramics provides the possibility of achieving ceramics with high fracture toughness relative to monolithics. Fabrication of ceramic composites, however, demands low processing temperatures to avoid fiber degradation. Formation of complex shapes further requires small diameter fibers as well as techniques for infiltrating the matrix between fibers. Polymers offer low temperature processability, control of rheology not available with ceramic powders, and should serve as precursors to matrix fibers. In recent years, a number of polysilanes and polysilezanes were investigated as potential presursors. A review of candidate polymers is presented, including recent studies of silsesquioxanes.

Hurwitz, Frances I.↗

Adhesive evaluation of water-soluble LARC-TPI

The water-soluble polyimide, identified as TPI(MTC)/H2O, was evaluated as a high temperature thermoplastic adhesive for bonding Ti-6Al-4V and comparing those results primarily with results reported in earlier work with the polyamic-acid/diglyme material. The lap shear strength test was the primary test performed to evaluate the adhesive before (controls) and after thermal exposure in air at 204 C for up to 5000 hours and after a 72 hour water-boil exposure. Lap shear strengths were determined at RT, 177, 204, and 232 C. The adhesive was also characterized after fracture by determining the glass transition temperature as well as defining the mode of failure by visual observation. In general, the results indicate that the TPI(MTC)/H2O retains high lap shear strengths after thermal exposure but had reduced strengths after the water-boil exposure. All failures were cohesive. The TPI(MTC)/H2O compared very well with previous data reported for the standard polyamic-acid/diglyme LARC-TPI results, and therefore, shows promise as a water-soluble adhesive for use in various applications.

Progar, D. J.↗

The Effect of Thin Film Adhesives on Mode II Interlaminar Fracture Toughness in Carbon Fiber Composites with Shape Memory Alloy Inserts

A single sheet of nickel-titanium (NiTi) shape memory alloy (SMA) was introduced within an IM7/8552 polymer matrix composite (PMC) panel in conjunction with multiple thin film adhesives to promote the interfacial bond strength between the SMA and PMC. End notched flexure (ENF) testing was performed in accordance to ASTM D7905 method for evaluation of mode II interlaminar fracture toughness (GIIC) of unidirectional fiber-reinforced polymer matrix composites. Acoustic emissions (AE) were monitored during testing with two acoustic sensors attached to the specimens. The composite panels examined using scanning electron microscopy techniques after part failure. GIIC values for the control composite samples were found to be higher than those of samples with embedded SMA sheets. The presence of adhesives bonded to SMA sheets further diminished the GIIC values. AE values revealed poor bonding of the panels, with little to no signals during testing.

End Notched Flexure↗

Initial Field Testing in the Deep Subsurface for the Thermal Breakout Project for Measuring In Situ Stress

The current state-of-the-art technology for in situ stress measurements involves an integrated approach that combines borehole breakout observations, drilling-induced tensile fractures, and hydraulic fracturing tests (i.e., mini-fracs); however, this methodology has several limitations that often prevent successful in situ stress measurements. One major limitation is that breakouts do not appear in every borehole and are generally a natural occurrence that cannot easily be controlled. Because borehole breakouts are used to measure the maximum horizontal in situ stress magnitude, the absence of borehole breakouts presents a major data gap for in situ stress measurements. As a response to this data gap a new thermal breakout technology is being developed that will provide a method for thermally inducing borehole breakouts and obtaining consistent measurements of the maximum horizontal stress magnitude. This thermal breakout technology involves heating the borehole and increasing the thermoelastic compressive stress in the rock until a breakout develops, which is directly correlated to the maximum horizontal stress magnitude. An initial component of the thermal breakout project involves developing a prototype downhole tool and performing field testing in the deep subsurface. The primary objective of the initial tool development and field testing is to provide a physical proof of concept for the thermal breakout technology. Three thermal breakout field tests were performed at approximately 4850 feet deep in the Sanford Underground Research Facility. Each test was performed in a borehole that had been previously used for overcoring stress measurements. The third and final test successfully created two diametrically opposed breakouts after deploying the thermal breakout tool for approximately 3 hours of continuous heating. Post-analysis of the thermally induced breakouts confirmed that the thermal breakout orientation directly corresponds to the known in situ stress orientation and magnitude.

Voegeli, Sam↗

Microstructure and Mechanical Behavior of Heat-Treated and Thermomechanically Processed TA15 Ti Alloy Composites

For TA15 Ti alloy, which has been widely used to form key load-bearing components in aeronautic and space fields, particular performances and corresponding microstructures are demanded due to various service environments. By applying single-phase field heat treatment, single-phase + two-phase field heat treatments, forging (α + β phase zone) combined with high-temperature aging and dual heat treatment, four types of microstructures, namely the fully lamellar microstructure, basket weave microstructure, two-phase composite microstructure and tri-modal microstructure, were obtained, respectively. And after conducting mechanical property tests for these microstructures, it was found that enhancing the lamellar thickness in the fully lamellar microstructures, reducing the content of equiaxed α phase to about 20% or increasing the content of lamellar phase in the two-phase composite microstructures and controlling the content of equiaxed α phase within 20% in the tri-modal microstructure were beneficial for performance improving. In addition, two-phase and three-phase composite microstructures possessed excellent comprehensive mechanical properties, and fully lamellar microstructures had the highest fracture toughness.

36 MATERIALS SCIENCE↗

Survey of baffle plate samples, specimen machining, and hydrogen measurements

This report outlines preliminary results on the survey and characterization of irradiated baffle plate, baffle former, and flux thimble tube specimens as part of the ongoing investigation into irradiation-induced embrittlement in austenitic stainless steels at ambient (room temperature) conditions. The specimens originated from commercial pressurized water reactor (PWR) components, covering displacement damage doses ranging from approximately 0.065 to 75 dpa. Initial scanning electron microscopy (SEM) surveys revealed that specimen surfaces exhibited fine machining marks and in-service-formed oxide layers on the side surfaces of the analyzed specimens. The oxide layers revealed specific features resembling localized "pitting-like" corrosion. An additional set of specimens representing in-service oxidation is being preserved for future microstructure analysis work. As believed, this will provide additional insights into long-term material degradation in PRWs. Specimen machining challenges emerged due to a complex failure of the electric discharge machining (EDM) system located in hot area. Despite partial restoration, issues persist with the EDM’s secondary power supply, necessitating the exploration of alternative EDM or computer numerical control (CNC) machining approaches to facilitate tensile specimen preparation. Currently, low speed saw cutting is in progress to prepare specimens for hydrogen measurements and general microstructure analysis. The near-term goals include completing tensile specimen machining for advanced mechanical testing and characterizing fracture mechanisms, and stress-corrosion cracking testing, ultimately aiming to identify and mitigate the ambient-condition intergranular cracking through targeted post-irradiation annealing strategies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation of Flow in Multi-Scale Porous Media Using the Lattice Boltzmann Method on Quadtree Grids

Abstract The unified lattice Boltzmann model is extended to the quadtree grids for simulation of fluid flow through porous media. The unified lattice Boltzmann model is capable of simulating flow in porous media at various scales or in systems where multiple length scales coexist. The quadtree grid is able to provide a high-resolution approximation to complex geometries, with great flexibility to control local grid density. The combination of the unified lattice Boltzmann model and the quadtree grids results in an efficient numerical model for calculating permeability of multi-scale porous media. The model is used for permeability calculation for three systems, including a fractured system used in a previous study, a Voronoi tessellation system, and a computationally-generated pore structure of fractured shale. The results are compared with those obtained using the conventional lattice Boltzmann model or the unified lattice Boltzmann model on rectangular or uniform square grid. It is shown that the proposed model is an accurate and efficient tool for flow simulation in multi-scale porous media. In addition, for the fractured shale, the contribution of flow in matrix and fractures to the overall permeability of the fractured shale is studied systematically.

Earth Sciences↗

Ion and laser microprobes applied to the measurement of corrosion produced hydrogen on a microscopic scale.

Use of an ion microprobe and a laser microprobe to measure concentrations of corrosion-produced hydrogen on a microscopic scale. Hydrogen concentrations of several thousand ppm were measured by both analytical techniques below corroded and fracture surfaces of hot salt stress corroded titanium alloy specimens. This extremely high concentration compares with only about 100 ppm hydrogen determined by standard vacuum fusion chemical analyses of bulk samples. Both the ion and laser microprobes were used to measure hydrogen concentration profiles in stepped intervals to substantial depths below the original corroded and fracture surfaces. For the ion microprobe, the area of local analysis was 22 microns in diameter and for the laser microprobe, the area of local analysis was about 300 microns in diameter. The segregation of hydrogen below fracture surfaces supports a previously proposed theory that corrosion-produced hydrogen is responsible for hot salt stress corrosion embrittlement and cracking of titanium alloys. These advanced analytical techniques suggest great potential for many areas of stress corrosion and hydrogen embrittlement research, quality control, and field inspection of corrosion problems. For example, it appears possible that a contour map of hydrogen distribution at notch roots and crack tips could be quantitatively determined. Such information would be useful in substantiating current theories of stress corrosion and hydrogen embrittlement.

Gray, H. R.↗

Flexible backbone aromatic polyimide adhesives

Continuing research at Langley Research Center on the synthesis and development of new inexpensive flexible aromatic polyimides as adhesives has resulted in a material identified as LARC-F-SO2 with similarities to polyimidesulfone, PISO2, and other flexible backbone polyimides recently reported by Progar and St. Clair. Also prepared and evaluated was an endcapped version of PISO2. These two polymers were compared with LARC-TPI and LARC-STPI, polyimides research in our laboratory and reported in the literature. The adhesive evaluation, primarily based on lap shear strength (LSS) tests at RT, 177 C and 204 C, involved preparing adhesive tapes, conducting bonding studies and exposing lap shear specimens to 204 C air for up to 1000 hrs and to a 72-hour water boil. The type of adhesive failure as well as the Tg was determined for the fractured specimens. The results indicate that LARC-TPI provides the highest LSSs. LARC-F-SO2, LARC-TPI and LARC-STPI all retain their strengths after thermal exposure for 1000 hrs and PISO2 retains greater than 80 percent of its control strengths. After a 72-hr water boil exposure, most of the four adhesive systems showed reduced strengths for all test temperatures although still retaining a high percentage of their original strength (greater than 60 percent) except for one case. The predominant failure type was cohesive with no significant change in the Tgs.

Progar, Donald J.↗

Flexible backbone aromatic polyimide adhesives

Continuing research at Langley Research Center on the synthesis and development of new inexpensive flexible aromatic polyimides as adhesives has resulted in a material identified as LARC-F-SO2 with similarities to polyimidesulfone, PISO2, and other flexible backbone polyimides recently reported by Progar and St. Clair. Also prepared and evaluated was an endcapped version of PISO2. These two polymers were compared with LARC-TPI and LARC-STPI, polyimides research in our laboratory and reported in the literature. The adhesive evaluation, primarily based on lap shear strength (LSS) tests at RT, 177 C and 204 C, involved preparing adhesive tapes, conducting bonding studies and exposing lap shear specimens to 204 C air for up to 1000 hrs and to a 72-hour water boil. The type of adhesive failure as well as the Tg was determined for the fractured specimens. The results indicate that LARC-TPI provides the highest LSSs. LARC-F-SO2, LARC-TPI and LARC-STPI all retain their strengths after thermal exposure for 1000 hrs and PISO2 retains greater than 80 percent of its control strengths. After a 72-hr water boil exposure, most of the four adhesive systems showed reduced strengths for all test temperatures although still retaining a high percentage of their original strength (greater than 60 percent) except for one case. The predominant failure type was cohesive with no significant change in the Tgs.

Progar, Donald J.↗

Slow Crack Growth of Boron Nitrides for Electric Propulsion Components

The Deep Space Gateway requires thruster systems to maintain spatial position. One control system being considered involves Hall thrusters. Historically, Hall thruster discharge channels have used several grades of hot-pressed hexagonal boron nitride. This study compliments data presented at ICACC (International Conference and Expo on Advanced Ceramics and Composites) 2018 and investigates the fracture toughness and slow crack growth parameters of several commercially available boron nitride grades including HP, M, M26, and Shapal Hi-M. The prior work revealed that some grades of BN absorb water and change strength thus presenting a philosophical conundrum on crack growth test methods. Advantages of different test methods will be discussed. The grades selected for this study are of interest because their available billet size is sufficient for Hall thruster discharge channels, or because they have heritage in Hall thruster applications. Ultimately, the data will be used to perform material selection, system design and reliability analyses.

Ceramics↗

Evaluation of photon irradiation treatment upon calcium content of ribs of Wistar rats using micro-XRF

Therapeutic doses of radiation have been shown to have deleterious consequences on bone health. Among the treatment strategies used for breast cancer treatment, the most used are radiotherapy and chemotherapy. Radiotherapy may be given to destroy the cancer cells using high-dose x-rays. Protocols vary considerably, but generally whole body irradiation totals from 10 to 15 Gy, whereas local therapy totals from 40 to 70 Gy. In clinical practice, the quantitative evaluation of bone tissue relies on measurements of bone mineral density values, which are closely associated with the risk of osteoporotic fracture. Improved survivorship rates of cancer patients receiving radiotherapy increase the importance of understanding the mechanisms and long-term effects of radiation-induced bone loss. In this work, we investigated the variation on calcium distribution in ribs of female Wistar rats (Rattus norvegicus) submitted to photon irradiation with a single dose of 20 Gy. The determination of the calcium distribution was performed using synchrotron radiation microfluorescence (SR-{mu}XRF) at the X-ray Fluorescence beamline at Brazilian Synchrotron Light Laboratory (LNLS). Animals were irradiated using the linear accelerator Varian registered (CLINAC 2100) at the University Centre for Cancer Control of the State University of Rio de Janeiro (CUCC/UERJ). The total dose delivered was 20 Gy. The animals were about three months old and weighting about 200g. They were distributed into two groups (seven per group): control (did not receive any treatment) and irradiated (submitted to irradiation procedure) groups. Results showed that calcium content decreased within the dorsal ribs of rats submitted to radiotherapy in comparison to the control group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗