Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flux Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

New Approach to Characterize CO2 and CH4 Emissions over Sacramento, California Using an Airborne Aircraft Measurement

Emission fluxes of carbon dioxide (CO2) and methane (CH4) over Sacramento, California, USA, are estimated using an aircraft equipped with a cavity ring-down greenhouse gas sensor through the Alpha Jet Atmospheric eXperiment (AJAX). To better quantify the emission fluxes over the entire city and two small point sources within the area, we designed flights in a cylindrical pattern and computed the emission fluxes from 9 flights over all seasons using the Kriging method based on Gausss divergence theorem. The concentrations at the downwind side of Sacramento show somewhat persistent patterns among the 9 flights, but the magnitudes and locations of the fluxes vary depending on the individual weather conditions and seasonality on a given flight day. The net emission fluxes tend to be smaller in summer (July) than winter (November). Both trace gas mixing ratios as well as the wind speed and direction show high spatial variability both horizontally and vertically. The local maximum emission fluxes over a landfill and a rice field measured on July 29, 2015, were 2-3 times lower than the maximum measured over the entire city. These low emission fluxes suggest that not only the local source but also the transport of greenhouse gases due to diurnal and seasonal variation in winds have a strong effect on the CO2 and CH4 flux estimation of the both local emissions and city-size emissions. Our results highlight that the aircraft-based approach is effective and useful for capturing city-size emission fluxes and estimating the greenhouse gas emissions and its sources.

airborne↗

Effect of gage size on the measurement of local heat flux

General formulas are derived for determining gage averaging errors of strip-type heat flux meters used in the measurement of one-dimensional heat flux distributions. In addition, a correction procedure is presented which allows a better estimate for the true value of the local heat flux. As an example of the technique, the formulas are applied to the cases of heat transfer to air slot jets impinging on flat and concave surfaces. It is shown that for many practical problems, the use of very small heat flux gages is often unnecessary.

Baumeister, K. J.↗

Miniature Convection Cooled Plug-type Heat Flux Gauges

Tests and analysis of a new miniature plug-type heat flux gauge configuration are described. This gauge can simultaneously measure heat flux on two opposed active surfaces when heat flux levels are equal to or greater than about 0.2 MW/m(sup 2). The performance of this dual active surface gauge was investigated over a wide transient and steady heat flux and temperature range. The tests were performed by radiatively heating the front surface with an argon arc lamp while the back surface was convection cooled with air. Accuracy is about +20 percent. The gauge is responsive to fast heat flux transients and is designed to withstand the high temperature (1300 K), high pressure (15 MPa), erosive and corrosive environments in modern engines. This gauge can be used to measure heat flux on the surfaces of internally cooled apparatus such as turbine blades and combustors used in jet propulsion systems and on the surfaces of hypersonic vehicles. Heat flux measurement accuracy is not compromised when design considerations call for various size gauges to be fabricated into alloys of various shapes and properties. Significant gauge temperature reductions (120 K), which can lead to potential gauge durability improvement, were obtained when the gauges were air-cooled by forced convection.

Liebert, Curt H.↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Flux of high-LET cosmic-ray particles in manned space flight

On the Apollo and Skylab missions the high-energy heavy ion (HZE) flux was measured by means of plastic nuclear track detectors. Measurements involved the fluxes of high linear energy transfer (LET), particles with Z between 6 and 26 incident on astronauts and on several biological experiments. Partial results of these measurements are presented; the effects of shielding and solar modulation are discussed.-

Benton, E. V.↗

Soil surface CO2 fluxes and the carbon budget of a grassland

Measurements of soil surface CO2 fluxes are reported for three sites within the First International Satellite Land Surface Climatology Project (ISLSCP) Field Experiment (FIFE) area, and simple empirical equations are fit to the data to provide predictions of soil fluxes from environmental observations. A prototype soil chamber, used to make the flux measurements, is described and tested by comparing CO2 flux measurements to a 40-L chamber, a 1-m/cu chamber, and eddy correlation. Results suggest that flux measurements with the prototype chamber are consistent with measurements by other methods to within about 20 percent. A simple empirical equation based on 10-cm soil temperature, 0- to 10-cm soil volumetric water content, and leaf area index predicts the soil surface CO2 flux with a rms error of 1.2 micro-mol sq m/s for all three sites. Further evidence supports using this equation to evaluate soil surface CO2 during the 1987 FIFE experiment. The soil surface CO2 fluxes when averaged over 24 hours are comparable to daily gross canopy photosynthetic rates. For 6 days of data the net daily accumulation of carbon is about 0.6 g CO2 sq m/d; this is only a few percent of the daily gross accumulation of carbon by photosynthesis. As the soil became drier in 1989, the net accumulation of carbon by the prairie increased, suggesting that the soil flux is more sensitive to temperature and drought than the photosynthetic fluxes.

Norman, J. M.↗

Sub-Ambient Performance of Potassium Sarcosinate for Direct Air Capture Applications: CO 2 Flux and Viscosity Measurements

Absorption based direct air capture (DAC) technologies have garnered significant interest in recent years due to their scalability, competitive regeneration energy requirements, and low susceptibility to degradation. One of the key advantages of DAC lies in its flexible siting options and the potential to utilize low-value land. However, most of the research in this field has been focused on ambient climate zones (T > 20 °C), overlooking sub-ambient (–30 °C < T < 20 °C) regions, which comprise approximately 70 % of the Earth’s surface. To fully realize the potential of DAC, it is essential to understand how DAC solvents perform in these sub-ambient conditions before any large-scale deployment can be considered. Among DAC solvents of interest, potassium sarcosinate (K-SAR) has emerged as a promising candidate due to its high CO 2 capacity, fast uptake kinetics, compatibility with contactor packing materials, low volatility, good thermal and oxidative stability, and competitive regeneration energy requirements compared to current industry standards. This paper characterizes the CO 2 flux and viscosity of K-SAR at sub-ambient conditions and explores the potential of using ethylene glycol and triethylene glycol as additives to prevent solvent freezing in DAC applications. For 1 M K-SAR, the CO 2 flux ranges between 1.3 × 10 -5 and 8.0 × 10 -5 mol m –2 s –1 across a temperature range of –5 °C to 45 °C. Ethylene glycol is shown to effectively suppress the freezing point of K-SAR below –30 °C with volumetric loadings of the additive as low as 0.1. Here, a reaction model was developed to predict the CO 2 flux for 1 M K-SAR at different temperatures, demonstrating good agreement between experimental and theoretical fluxes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar Neutrino Observations at the Sudbury Neutrino Observatory

The Sudbury Neutrino Observatory (SNO) is a 1000-tonne heavy water Cherenkov detector. Its usage of \dto as target allows the simultaneous measurements of the $\nu_e$ flux from $^8$B decay in the Sun and the total flux of all active neutrino species through the charged-current and the neutral-current interactions on the deuterons. Assuming the standard $^{8}$B shape, the $\nu_e$ component of the $^{8}$B solar neutrino flux is measured to be $\phi_e = 1.76^{+0.05}_{-0.05}{(stat.)}^{+0.09}_{-0.09} {(syst.)} x 10^6 {\rm cm}^{-2} {\rm s}^{-1}$ for a kinetic energy threshold of 5 MeV. The non-\nue component is found to be Φ μτ $\= 3.41^{+0.45}_{-0.45}{(stat.)}^{+0.48}_{-0.45} {(syst.)} x 10^6 {\rm cm}^{-2} {\rm s}^{-1}$. This $5.3\sigma$ difference provides strong evidence for $\nu_{e}$ flavor transformation in the solar neutrino sector. The total active neutrino flux is measured with the neutral-current reaction at a neutrino energy threshold of 2.2 MeV. This flux is determined to be $\phi_{NC} = 5.09^{+0.44}_{-0.43}{(stat.)}^{+0.46}_{-0.43} {(syst.)} x 10^6 {\rm cm}^{-2} {\rm s}^{-1}$, and is consistent with solar model predictions. Assuming an undistorted $^8$B spectrum, the night minus day rate is 14.0$\pm$6.3(stat.)$^{+1.5}_{-1.4}$(sys.)\% of the average rate in the charged-current channel. If the total active neutrino flux is constrained to have no asymmetry, the night-day asymmetry in the $\nu_e$ flux is found to be 7.0$\pm$4.9(stat.)$^{+1.3}_{1.2}$(sys.)\%. A global analysis of all the available solar neutrino data in terms of matter-enhanced oscillations of two active flavors strongly favors the Large Mixing Angle (LMA) solution.

Poon, A. W. P.↗

Measurement of the fluxes of galactic cosmic ray H-2 and He-3 in 1972 - 1973

If a nearby source of low-energy helium is present, which has traversed a relatively small amount of matter and thus has not caused the production of a significant amount of H-2 or He-3, then these abundance ratios will be suppressed, particularly at low energies. This seems to be the most likely explanation for low ratios.

Teegarden, B. J.↗

Environmental charging effects monitors for operational satellites

A set of three instruments has been developed that can provide early detection of potentially dangerous geomagnetic substorm conditions, and monitor the spacecraft response. The set consists of three instruments: (1) a 'surface voltage sensor' that measures the characteristic energy of collected electrons or ions from +100 to -20,000 volts; (2) a 'nanoammeter' or logarithmic current density sensor that measures local electron flux by measuring currents from 10 to the -9th to 10 to the -5th A; and (3) a 'transient events counter' that counts the spurious pulses from electrostatic discharges that are coupled into the spacecraft wiring harness. Performance characteristics, specifications, and application of these instruments are discussed.

Sturman, J. C.↗

Experimental evaluation of self-calibrating cavity radiometers for use in earth flux radiation balance measurements from satellites

A method for evaluating out-of-field response of wide-field, earth-viewing satellite radiometers is described. The equipment which simulates the earth and space consists of a central blackbody surrounded by a cooled ring. The radiometric and orbital considerations are discussed. Some test results for prototype ERBE cavity sensors are included. This presentation is restricted to longwave radiative transfer

Hickey, J. R.↗

A Concept for the Inclusion of Analytical and Computational Capability in Existing Systems for Measurement of Neutron Flux

For approximately two decades, efforts have been sponsored by NASA's Marshall Space Flight Center to make possible high-speed, automated classification and quantification of constituent materials in various harsh environments. MSFC, along with the Air Force/Arnold Engineering Development Center, has led the work, developing and implementing systems that employ principles of emission and absorption spectroscopy to monitor molecular and atomic particulates in gas plasma of rocket engine flow fields. One such system identifies species and quantifies mass loss rates in H2/O2 rocket plumes. Other gases have been examined and the physics of their detection under numerous conditions were made a part of the knowledge base for the MSFC/USAF team. Additionally, efforts are being advanced to hardware encode components of the data analysis tools in order to address real-time operational requirements for health monitoring and management. NASA has a significant investment in these systems, warranting a spiral approach that meshes current tools and experience with technological advancements. This paper addresses current systems - the Optical Plume Anomaly Detector (OPAD) and the Engine Diagnostic Filtering System (EDIFIS) - and discusses what is considered a natural progression: a concept for migrating them towards detection of high energy particles, including neutrons and gamma rays. The proposal outlines system development to date, basic concepts for future advancements, and recommendations for accomplishing them.

Patrick, Clinton↗

Concept for Inclusion of Analytical and Computational Capability in Optical Plume Anomaly Detection (OPAD) for Measurement of Neutron Flux

Researchers are working on many konts to make possible high speed, automated classification and quantification of constituent materials in numerous environments. NASA's Marshall Space Flight Center has implemented a system for rocket engine flow fields/plumes; the Optical Plume Anomaly Detection (OPAD) system was designed to utilize emission and absorption spectroscopy for monitoring molecular and atomic particulates in gas plasma. An accompanying suite of tools and analytical package designed to utilize information collected by OPAD is known as the Engine Diagnostic Filtering System (EDIFIS). The current combination of these systems identifies atomic and molecular species and quantifies mass loss rates in H2/O2 rocket plumes. Additionally, efforts are being advanced to hardware encode components of the EDIFIS in order to address real-time operational requirements for health monitoring and management. This paper addresses the OPAD with its tool suite, and discusses what is considered a natural progression: a concept for migrating OPAD towards detection of high energy particles, including neutrons and gamma rays. The integration of these tools and capabilities will provide NASA with a systematic approach to monitor space vehicle internal and external environment.

Patrick, M. Clinton↗