Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Computational Analysis of Artificial Gravity as a Possible Countermeasure to Spaceflight Induced Bone Loss

During exploration class missions, such as to asteroids and Mars, astronauts will be exposed to reduced gravity for extended periods. Data has shown that astronauts lose bone mass at a rate of 1% to 2% a month in microgravity, particularly in lower extremities such as the proximal femur. Exercise countermeasures have not completely eliminated bone loss from long duration spaceflight missions, which leaves astronauts susceptible to early onset osteoporosis and greater risk of fracture. Introduction of the Advanced Resistive Exercise Device and other large exercise devices on the International Space Station (ISS), coupled with improved nutrition, has further minimized bone loss. However, unlike the ISS, exploration vehicles will have very limited volume and power available to accommodate such capabilities. Therefore, novel concepts like artificial gravity systems are being explored as a means to provide sufficient load stimulus to the musculoskeletal system to mitigate bone changes that may lead to early onset osteoporosis and increased risk of fracture. Currently, there is minimal data available to drive further research and development efforts to appropriately explore such options. Computational modeling can be leveraged to gain insight on the level of osteoprotection that may be achieved using artificial gravity produced by a spinning spacecraft or centrifuge. With this in mind, NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone both for gravitational unloading condition and the equivalent of 1g daily load stimulus. Using this model, it is possible to simulate vBMD changes in trabecular and cortical bone under different gravity conditions. In this presentation, we will discuss our preliminary findings regarding if and how artificial gravity may be used to mitigate spaceflight induced bone loss.

Mulugeta, L.↗

Mobilization Protocols for Hybrid Sensors for Environmental AOP Sampling (HySEAS) Observations

The protocols presented here enable the proper mobilization of the latest-generation instruments for measuring the apparent optical properties (AOPs) of aquatic ecosystems. The protocols are designed for the Hybrid Sensors for Environmental AOP Sampling (HySEAS) class of instruments, but are applicable to the community of practice for AOP measurements. The protocols are organized into eleven sections beyond an introductory overview: a) cables and connectors, b) HySEAS instruments, c) platform preparation, d) instrument installation, e) cable installation, f) test deployment, g) test recovery, h) maintenance, i) shipping, j) storage, and k) smallboat operations. Each section concentrates on documenting how to prevent the most likely faults, remedy them should they occur, and accomplishing both with the proper application of a modest set of useful tools. Within the twelve sections, there are Socratic exercises to stimulate thought, and the answers to these exercises appear in Appendix A. Frequently asked questions (FAQs) are summarized in a separate section after the answers to the exercises in Appendix B. For practitioners unfamiliar with the nautical terms used throughout this document plus others likely encountered at sea, an abbreviated dictionary of nautical terms appears in Appendix C. An abbreviated dictionary of radiotelephone terms is presented in Appendix D. To ensure familiarity with many of the tools that are presented, Appendix E provides a description of the tools alongside a thumbnail picture. Abbreviated deployment checklists and cable diagrams are provided in Appendix F. The document concludes with an acknowledgments section, a glossary of acronyms, a definition of symbols, and a list of references.

Mobilizarion↗

Miniature Biometric Sensor Project

Heart rate monitoring (HRM) is a critical need during exploration missions. Unlike the four separate systems used on ISS today, the single HRM system should perform as a diagnostic tool, perform well during exercise or high level activity, and be suitable for use during EVA. Currently available HRM technologies are dependent on uninterrupted contact with the skin and are prone to data drop-out and motion artifact when worn in the spacesuit or during exercise. Here, we seek an alternative to the chest strap and electrode based sensors currently in use on ISS today. This project aims to develop a single, high performance, robust biosensor with focused efforts on improved heart rate data quality collection during high intensity activity such as exercise or EVA.

Falker, John↗

Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits Magnetic Pulse which is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat to beat comparison between the current ISS standard and CS2.Upon Bluetooth(Registered Trademark) validation aboard ISS, down select of a new BT_HRM for operational use will be made.

Buxton, Roxanne E.↗

Bluetooth Heart Rate Monitors For Spaceflight

Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits magnetic pulse that is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat-to-beat comparison between the current ISS standard and CS2. Upon Bluetooth validation aboard ISS, the research team will down select a new BT_HRM for operational use.

Buxton, R. E.↗

Effects of Zoledronate and Mechanical Loading during Simulated Weightlessness on Bone Structure and Mechanical Properties

Space flight modulates bone remodeling to favor bone resorption. Current countermeasures include an anti-resorptive drug class, bisphosphonates (BP), and high-force loading regimens. Does the combination of anti-resorptives and high-force exercise during weightlessness have negative effects on the mechanical and structural properties of bone? In this study, we implemented an integrated model to mimic mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hindlimb unloading (HU). Our working hypothesis is that CL combined with ZOL in the HU model induces additive structural and mechanical changes. Thirty-two C57BL6 mice (male,16 weeks old, n8group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45gkg), or saline vehicle, prior to experiment. The right tibia was axially loaded in vivo, 60xday to 9N in compression, repeated 3xweek during HU. During the application of compression, secant stiffness (SEC), a linear estimate of slope of the force displacement curve from rest (0.5N) to max load (9.0N), was calculated for each cycle once per week. Ex vivo CT was conducted on all subjects. For ex vivo mechanical properties, non-CL left femurs underwent 3-point bending. In the proximal tibial metaphysis, HU decreased, CL increased, and ZOL increased the cancellous bone volume to total volume ratio by -26, +21, and +33, respectively. Similar trends held for trabecular thickness and number. Ex vivo left femur mechanical properties revealed HU decreased stiffness (-37),and ZOL mitigated the HU stiffness losses (+78). Data on the ex vivo Ultimate Force followed similar trends. After 3 weeks, HU decreased in vivo SEC (-16). The combination of CL+HU appeared additive in bone structure and mechanical properties. However, when HU + CL + ZOL were combined, ZOL had no additional effect (p0.05) on in vivo SEC. Structural data followed this trend with ZOL not modulating trabecular thickness in CL + NAHU mice. In summary, our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. Based on these results, we conclude that, at the structural and stiffness level, zoledronate treatment during simulated spaceflight does not impede the skeletal response to axial compression. In contrast to our hypothesis, our data show that zoledronate confers no additional mechanical or structural benefit beyond those gained from cyclical loading.

Mechanical Loading↗

Does Simulated Weightlessness Alter the Methylation Status of Gene Promoters During Bone Remodeling?

The skeleton interacts with its environment in a way that resembles a mechanostat - through a controlled process of bone remodeling, namely local formation and resorption, to maintain a healthy structure. During weightlessness, astronauts lose structure in weight-bearing bones due to decreased formation by osteoblasts and increased resorption by osteoclasts. In contrast, increased mechanical loading through exercise targets bone remodeling to remove and repair microdamage, improving structural integrity. In fact, recent advances in astronaut exercise regimens have prevented the deleterious changes in skeletal structure during spaceflight. However, knowledge of the molecular underpinnings of the skeletal response to spaceflight and to mechanical stimulation is limited. We propose that epigenetic modification, specifically DNA methylation, may influence osteoblast differentiation and activity during spaceflight and exercise. We hypothesize that simulated weightlessness hypermethylates pro-osteoblastogenic gene promoters and decreases expression of osteoblastogenic genes. Oppositely, we hypothesize that mechanical loading hypomethylates pro-osteoblastogenic gene promoters and increases expression of osteoblastogenic genes.

Stevick, Rebecca J.↗

Temporal Changes in Astronauts’ Muscle and Cardiorespiratory Physiology Pre-, In-, and Post-Spaceflight

NASA’s vision for future exploration missions depends on the ability to protect astronauts’ health and safety for performance of Extravehicular Activity (EVA), and to allow astronauts to safely egress from vehicles in a variety of landing scenarios (e.g. water landing upon return to Earth and undefined planetary/lunar landings). Prolonged exposure to spaceflight results in diminished tolerance to prolonged physical activity, decreased cardiac and sensorimotor function, and loss of bone mineral density, muscle mass, and muscle strength. For over 50 years exercise has been the primary countermeasure against these physiologic decrements during spaceflight, and while the resulting protection is adequate for ISS missions (i.e., Soyuz landing, microgravity EVAs), there is little information regarding time-course changes in muscle and aerobic performance. As spaceflight progresses towards longer exploration missions and vehicles with less robust exercise capabilities compared to ISS, countermeasures will need to be combined and optimized to protect crew health and performance across all organ systems over the course of exploration missions up to 3 years in duration. This will require a more detailed understanding of the dynamic effects of spaceflight on human performance. Thus, the focus of this study is quantifying decrements in physical performance over different mission durations, and to provide detailed information on the physiological rational for “why” and “when” observed changes in performance occur. The research proposed will temporally profile changes in astronauts’ cardiorespiratory fitness, muscle mass, strength, and endurance over spaceflight missions of 2 months, 6 months, and up to 1 year in duration. Additionally, an extrapolation model will provide predictions for changes associated with exploration missions 2-3 years in duration. To accomplish these objectives astronauts will be asked to participate in pre, in, post-flight measurement of muscle performance, muscle size, cardiorespiratory fitness and submaximal performance capabilities, as well as non-invasive assessment of cerebral and muscle oxygenation and perfusion (Table 1). Additionally, ambulatory and in-flight exercise, nutrition, and sleep will be monitored using a variety of commercial technologies and in-flight assessment tools. Significance: Our detailed testing protocol will provide valuable information for describing how and when spaceflight-induced muscle and aerobic based adaptations occur over the course of spaceflight missions up to and beyond 1 year. This information will be vital in the assessment as to whether humans can be physically ready for deep space exploration such as Mars missions with current technology, or if additional mitigation strategies are necessary.

Downs, M. E.↗

Evidence-based Approach to Establish Space Suit Carbon Dioxide Limits

A literature survey was conducted to assess if published data (evidence) could help inform a space suit carbon dioxide (CO2) limit. The search identified more than 120 documents about human interaction with elevated CO2. Until now, the guiding philosophy has been to drive space suit CO2 as low as reasonably achievable. NASA’s EVA Office requested an evidencebased approach to support a new generation of exploration-class extravehicular activity (EVA) space suits. Specific literature data about CO2 are not available for EVA in microgravity because EVA is an operational activity and not a research platform. However, enough data from groundbased research are available to facilitate a consensus of expert opinion on space suit CO2 limits. The compilation of data in this report can answer many but not all concerns about the consequences of hypercapnic exercise in a space suit. Inspired partial pressure of CO2 (PICO2) and not dry-gas partial pressure of CO2 (PCO2) is the appropriate metric for hypercapnic dose to establish space suit CO2 limits. The reduction of inspired gas partial pressures by saturation of the inspired gases with water vapor at 37°C is a significant factor under conditions of hypobaric space suit operation. Otherwise healthy EVA astronauts will exhibit wide variability in responses to acute hypercapnia while at rest and during exercise. What is clear from the literature is the absence of prospective (objective) accept or reject criteria for CO2 exposure in general, and no such criteria exist for operating a space suit. There is no absolute “Gold Standard” for an acceptable acute hypercapnic limit, just a gradual decrease in performance as CO2 increases. Acceptable CO2 exposure limits are occupation, situation (learned or novel tasks), and personspecific. Investigators who measured hypercapnic physiology rarely correlated those changes to neurocognitive symptoms, and those that measured hypercapnic neurocognition rarely correlated those changes with physiology. Some answers about changes in neurocognition and functional EVA performance during hypercapnic exercise in a space suit await new research.

Conkin, Johnny↗

Probability of Decompression Sickness and Venous Gas Emboli from 49 NASA Hypobaric Chamber Tests with Reference to Exploration Atmosphere

Introduction: Decompression sickness (DCS) is a complex biophysical event; it combines human perception of pain, for instance, and the presence of a gas phase in the tissues. Living tissues are complex and dynamic. Micronuclei and later bubbles may or may not form given what appears to be the same conditions. Even when bubbles grow, symptoms may or may not develop under what appears to be the same conditions. Therefore, at this time it is appropriate to consider DCS as a probabilistic rather than a deterministic event. Methods: Probabilistic models about hypobaric DCS and venous gas emboli (VGE) require a large amount of quality research data, a definition of decompression dose using physical and physiologic variables, and a flexible analytical approach that can quantify the association between each outcome and all covariates of interest (assuming independence between DCS and VGE) and then ultimately be extended to acknowledge dependencies between DCS and VGE. Our DCS and VGE data are from 1,031 hypobaric decompressions from 1983 to 2016. A total of 577 humans participated in 49 hypobaric chamber tests to evaluate denitrogenation procedures used by astronauts in the Space Shuttle and International Space Station programs. We defined decompression dose as the ratio of computed nitrogen tension in a theoretical 360-minute half-time compartment to ambient pressure, which accounts for denitrogenation and exposure pressure as well as explanatory variables such as age, sex, body mass index, and the presence or absence of ambulation as part of exercise at the exposure pressure. A parametric survival model, using a log-logistic distribution, was used to quantify the time to development of DCS, VGE, and Grade IV VGE. Results: Our survival estimates are applicable to simple hypobaric decompressions, such as depressurizations in 5 to 30 minutes to exposure pressures between 4 and 10 pounds per square inch absolute (psia) and after minutes to hours of denitrogenation, either under resting or exercise conditions to accelerated denitrogenation. The regressions are applicable to exposures between 2 to 6 hours and under conditions of ambulation or no ambulation as part of exercise at the test pressure. We estimate that an exposure to 4.3 psia with simulated extravehicular activity (EVA) that includes ambulation after equilibration to the exploration atmosphere at 8.2 psia with a 34% oxygen atmosphere will result in 3.1% DCS (1.8% to 5.2 95% confidence interval), 23.2% VGE (16.7 to 31.2%), and 8.5% Grade IV VGE (4.7 to 14.7%) in equal samples of men and women exposed for 6 hours. Discussion: Probabilistic models for DCS, VGE, and Grade IV VGE can be used to inform those that plan future EVAs. Their applications are useful to quantify the risk of DCS and VGE in astronauts that perform EVAs in low-pressure space suits while in space or while exploring the surfaces of the moon or Mars.

Johnny Conkin↗

Monitoring Biomarkers for Muscular Atrophy Using an Electrochemical Chip for Astronaut Space Health

Skeletal muscle atrophy is a serious health problem for astronauts in long-duration space flight under microgravity conditions. Preventative measures against muscle atrophy require specific exercise and dietary regimens. Preemptive measurements to improve treatment have the potential to streamline these regimens, decreasing their daily footprint and increasing astronaut quality of life. The objective of our proposed project is to (1) develop a fully integrated disposable microelectrode array chip (with the size of a stamp) that can be interfaced with a handheld electronic system for simultaneous detection of the a panel of biomarkers to monitor the progression of skeletal muscle atrophy due to disuse under microgravity in long-duration spaceflights; and (2) use such quantitative information to guide the combined countermeasures of physical exercise and pharmaceuticals (i.e. specific protease inhibitors) so that the intensity, duration and frequency of exercise can be reduced. Note: The presentation includes voice commentary and plays best as a slide show. The voice begins once the presentation starts, and only requires the user to click to the next slide each time. With a run time of ~15 mins.

Biosensor↗

Monitoring Biomarkers for Muscular Atrophy using an Electronic Chip for Astronaut Health

Skeletal muscle atrophy is a serious health problem for astronauts in long-duration space flight under microgravity conditions. Preventative measures against muscle atrophy require specific exercise and dietary regimens. Preemptive measurements to improve treatment have the potential to streamline these regimens, decreasing their daily footprint and increasing astronaut quality of life. The objective of our proposed project is to (1) develop a fully integrated disposable microelectrode array chip (with the size of a stamp) that can be interfaced with a handheld electronic system for simultaneous detection of the a panel of biomarkers to monitor the progression of skeletal muscle atrophy due to disuse under microgravity in long-duration spaceflights; and (2) use such quantitative information to guide the combined countermeasures of physical exercise and pharmaceuticals (i.e. specific protease inhibitors) so that the intensity, duration and frequency of exercise can be reduced.

Biosensing↗

Habitable Working and Living Spaces in the Deep Space Science Vessel

The Deep Space Science Vessel (DSSV) is a conceptual design of a very large spacecraft intended as a mobile microgravity science platform. It represents an effort to conceptualize the systems and internal architectures needed to support a forty-eight-person crew for multi-year missions throughout the inner solar system and potentially beyond. The general arrangement of the DSSV is a modular spacecraft. Considering only the pressurized, habitable elements, the DSSV includes two large pressurized modules (Hab and Lab) docked together along with eight smaller node modules completing the habitable configuration. The Hab and Lab modules are docked side by side, with the longitudinal axes parallel to each other and a single docking port connecting them. A node module is docked to each dome on the Hab and Lab modules, such that the two small node modules on each end of the large Hab and Lab domes are docked both to each other and to the Hab and Lab. This creates a “racetrack” translation path on the interior. The other four node modules are docked at the center of the Hab and Lab modules, two on each side, creating another “racetrack” translation path perpendicular to the first one. The DSSV has a generally vertical orientation. Within the Hab and Lab modules the decks are perpendicular to the longitudinal axis. The node modules are oriented with their longitudinal axes perpendicular to those of the Hab and Lab modules, so the nodes have a horizontal internal orientation. Decks are numbered one through nine, with decks two and eight representing the “top” and “bottom” domes of the Hab and Lab modules. The Hab Module decks encompass the ship’s galley, crew quarters, waste, hygiene, portions of crew exercise, and group recreation. The Lab Module contains food production facilities, the life science lab, the ship’s infirmary, the physical science lab, and the maintenance and fabrication workshop. The Node Modules serve a number of different functions. The two Exercise Nodes are docked to deck five of both the Hab and Lab modules and contain most of the aerobic and resistive exercise devices. Also docked to deck five but on the opposite side of the Hab and Lab modules are the Observation Deck and Space Café. These two node modules provide social gathering space for small numbers of crew. The Mission Operations Node is on deck nine directly above the Galley and contains spacecraft monitoring and commanding capabilities. Docked to it is the EVA Operations Node, which contains suit maintenance and storage. (The airlock is a separate, external element docked to the EVA Operations Node.) The Subsystems Node is on deck one beneath the maintenance and fabrication workshop. Docked to it is the Stowage Node. This node does not house DSSV primary stowage, but is a staging point where stowage brought in from logistics modules can be sorted, unpacked, or repacked as needed prior to distribution to the appropriate sections of the spacecraft.

Deep Space Habitat↗

Increased Rates of Hip and Spine Fractures in Astronauts are Associated with Longer Spaceflight Durations

Given the accelerated declines in bone mineral density reported in US astronauts serving on the International Space Station, there is a possibility that a prolonged exposure to spaceflight could put astronauts at increased fracture risk during subsequent planetary explorations or after return to Earth. To date, there have been no fractures in astronauts during spaceflight. Recently-reported data from a flight study suggested that intake of the bisphosphonate alendronate combined with resistive exercise (on the Advanced Resistive Exercise Device – ARED) preserved more astronauts at their preflight skeletal status after a ~6-mos spaceflight than with ARED exercise alone. However, there is low acceptance of alendronate, or the recommended zoledronic acid, to suppress in-flight bone loss largely due to concern for unintended medication side effects and a perceived absence of astronaut fractures that can be directly attributable to spaceflight exposure. Hence, a recent survey of all astronaut fractures was analyzed to assess whether the rate of postflight fractures could be associated with extended spaceflight exposures. The fracture survey was of 262 astronauts across 8433.6 person-years (PY) and grouped according to previous exposure to a “Long Duration (LD)” spaceflight (3 mos or greater, but typically 6-mos). The number of fractures was modeled using count regression adjusting for i) the repeated measures within individuals across the groups, ii) the differing length of surveillance for each individual and iii) age at start of surveillance for each of the groups. Astronaut Group by Spaceflight Exposure #Individuals PY Covered No Exposure to Spaceflight 262 1882.7 No Exposure to LD spaceflight “Non-LD” 232 6121.3 Exposure to LD spaceflight 42 429.6 Analysis revealed an increased rate of hip and spine fractures for surveillance periods compared between LD Exposure and Non-LD Exposure: Hip – Relative Rate: 3.4 (95%CI: 1.0, 12.0); Spine– Relative Rate: 3.4 (95%CI: 1.0, 11.6). For all other skeletal sites, rates of fracture were similar for LD and Non-LD exposures. Data comparisons were conducted between groups of astronauts to preclude the interpretation of greater physical activity in astronauts as a contributing factor to fracture rates. This analysis of fracture data is the first report associating postflight hip and spine fractures in astronauts with exposure to extended duration spaceflights. Further analyses integrating co-morbidities for bone loss are planned.

skeleton↗

Assessment of Individualizing lactobacillus plantarum Supplementation with Precision Health to Preserve Muscle Health in Astronauts During Long Duration Spaceflight

Muscle atrophy is an unfortunate reality seen after spending time in microgravity. Decreases in muscle strength, size, and endurance can negatively impact mission productivity and increase the risk of injury in astronauts. In preparing for long-duration spaceflight aboard future orbiting stations and interplanetary vessels, supplementation with lactobacillus plantarum has been suggested as a possible countermeasure for crew members. Early clinical trials have shown the probiotic to improve muscle strength, endurance, and associated biomarkers, even without significant physical exercise by influencing the gut-muscle-axis. While current onboard exercise protocols have significantly helped limit degradation (as seen below), individualized implementation of this supplement could not only add another layer of protection but also protect against inadequate exercise equipment on future missions due to payload constraints

Precision Health↗

Recent Improvements and Verification of A Full Body Model in Opensim

BACKGROUND: The dynamic feasibility [1,2] criterion, that the subject’s Center of Pressure (COP) be located within the Base of Support (BOS) which outlines the feet, has aided in assessing the stability of human motion recorded on earth while performing the recorded tasks in lunar gravity or as countermeasures exercises on a vibration isolation and stabilization system in microgravity. The convex hull of the BOS on the platform under the subject’s feet was estimated using virtual markers on the feet of the scaled subject model. The COP was calculated using the ground reaction forces and moments determined from motion capture data with biomechanical modeling tools [3]. Occasionally, large-amplitude oscillatory spikes or “artifacts” were observed in the subject’s linear and angular momentum derivatives, affecting some COP data derived from motion capture. The purpose of this investigation was to assess and improve the accuracy of model scaling and BOS estimation as well as to determine the efficacy of model adjustments in mitigating artifacts influencing motion capture-derived ground reaction force and COP results. METHODS: To aid evaluation of proposed process and model updates, motion capture data were collected for two subjects during unit test and range of motion trials, lunar tasks, and countermeasures exercise motions. Markers were added to the full body Plug-in Gait marker set [4] during data collection. New markers were placed on the front, back, sides, and top of the head to improve scaling using distances between marker pairs. Medial elbow markers were added to stabilize the upper arm during OpenSim Inverse Kinematics (IK) [5]. Finally, markers were added on the outer edge of the heels and on the outside edges of the first and last toes on each foot. These additional foot markers were made available to test new automated foot scaling techniques and to calculate the error between the subject’s estimated and recorded BOS. The modified unscaled OpenSim Full Body Rajagopal Model [6,7] was adjusted using some previously investigated techniques [8] to mitigate rapid shifts in joint angles occurring during IK, as these were found to cause the spike artifacts observed in subsequent stages of analysis. Since OpenSim models use Euler angles and rotation sequences, the arm axes of rotation were adjusted, and the pelvis order of rotation was changed to minimize the likelihood of encountering “gimbal lock” during common human motion. The model clavicle, arm, elbow, wrist, pelvis, and ankle angle limits were adjusted to better accommodate the full human range of motion seen in exercise and lunar data. The shoulder joint center was calculated using a “pivoting” algorithm [9], and both shoulder joint center and upper arm markers were included during IK to provide additional shoulder stability on a case-by-case basis. The quality of IK results was assessed by three criteria: minimizing error between recorded motion capture markers and model markers, checking for reasonable rates of change in joint angles between fames (i.e., no IK artifacts), and ensuring the absence of spikes in the inertial forces and angular momentum derivatives calculated using a custom OpenSim plugin [10]. RESULTS: The additional markers placed on the subject during data collection allowed the head and feet to be scaled more accurately using distances between new marker pairs. Scaling with BOS markers placed on the subject and removing the limit on subtalar angle resulted in more accurate BOS determination. Unrealistically large changes in joint angles between frames could be reduced by including clavicle, sternum, and medial elbow markers during IK. In cases with large arm ranges of motion, results could be further improved by running IK using medial elbow and virtual shoulder joint center markers. Model adjustments significantly improved the IK results affecting COP calculation and increased the accuracy of BOS estimation.

C A Bell↗

Preliminary Results Cycling GEOS-JEDI with GSI-based Background Errors

The first phase of transitioning the NASA GMAO GEOS atmospheric data assimilation capabilities to JEDI involves the replacement of the Grid-point Statistical Interpolation (GSI) with a corresponding JEDI analysis. This includes taking JEDI's Unified Observation Operator (UFO), its underlying dependencies, and the JEDI solver that enables a hybrid 4DEnVar strategy similar to what is used in the current GEOS-GSI system. Variational analysis involves at least two main components associated with the observation and background cost function terms. The first is directly related to the UFO, which is being carefully validated in a joint collaboration between GMAO and NCEP to demonstrate consistency with corresponding observations usage in GSI. The second component is the background term, which in a hybrid system involves the ability to set up both a climatologically-based term and an ensemble-based term. JEDI provides the means to implement both terms through its BUMP component. Use of BUMP would require a complete re-tune of both climatological and ensemble, which is a non-trivial exercise we would prefer to avoid. As an alternative, the work here studies the results of interfacing the GSI-background error capability (GSIBEC) into JEDI through SABER. With this, the exact same background error covariance formulation used in GSI can be employed in JEDI without need for re-tuning. This brief summary covers the work done to interface GSIBEC into JEDI and shows preliminary results where the background error covariances of the control (GEOS-GSI) and experiment (GEOS-JEDI) are identical in corresponding cycling experiments. The cycling exercise is obviously preliminary and so much can be expected from GEOS-JEDI when compared to GEOS-GSI. There is still a number of features that need closer attention and although in some cases in principle ready to cycle have been intentionally either turned off or not fully exercised (e.g., VarBC is applied but not cycled). Other features are still pending implementation, one such example is the implementation of the Tangent Linear Normal Mode Constraint. Still, results are quite encouraging as hopefully the discussion here illustrates.

Ricardo Todling↗

Assessment of the Performance of the Atmospheric Correction Algorithm MAJA for Sentinel-2 Surface Reflectance Estimates

The correction of atmospheric effects on optical remote sensing products is an essential component of Analysis Ready Data (ARD) production lines. The MAJA processor aims at providing accurate time series of surface reflectances over land for satellite missions, such as Sentinel-2, Venμs, and Landsat 8. The Centre d’Études Spatiales de la Biosphère (CESBIO) and the Centre National d’Études Spatiales (CNES) share a common effort to maintain, validate, and improve the MAJA processor, using state-of-the-art ground measurement sites, and participating in processor inter-comparisons, such as the Atmospheric Correction Intercomparison Exercise (ACIX). While contributing to the second ACIX-II Land validation exercise, it was found that the candidate MAJA dataset could not adequately be compared to the main reference dataset. MAJA reflectances were corrected for adjacency and topography effects while the reference dataset was not, excluding MAJA from a part of the performance metrics of the exercise. The first part of the following study aims at providing complementary performance assessment to ACIX-II by reprocessing MAJA surface reflectances without adjacency nor topographic correction, allowing for an un-biased full resolution comparison with the reference Sentinel-2 dataset. The second part of the study consists of validating MAJA against surface reflectance measurements time series of up to five years acquired at three automated stations. Both approaches provide extensive insights on the quality of MAJA Sentinel-2 Level 2 products.

ROSAS↗