Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional simulations of ion dynamics in an Electron Cyclotron Resonance Ion Source

We present a three-dimensional simulation of the ion dynamics in an electron cyclotron resonance ion source. Ion trajectories in the min-B field of the source are calculated taking ion-ion and electron-ion collisions into account. The electrons are not tracked but considered as a neutralizing background with a Maxwell-Boltzmann velocity distribution. Some applications of the code are discussed, e.g., the calculated charge-state and phase-space distributions of extracted ion beams and the ionization dynamics in the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques

Purpose: The goal of this study is to determine a method for Monte Carlo (MC) characterization of the miniature electronic brachytherapy x-ray sources (MEBXS) and to set dosimetric parameters according to TG-43U1 formalism. TG-43U1 parameters were used to get optimal designs of MEBXS. Parameters that affect the dose distribution such as anode shapes, target thickness, target angles, and electron beam source characteristics were evaluated. Optimized MEBXS designs were obtained and used to determine radial dose functions and 2D anisotropy functions in the electron energy range of 25-80 keV. Methods: Tungsten anode material was considered in two different geometries, hemispherical and conical-hemisphere. These configurations were analyzed by the 4C MC code with several different optimization techniques. The first optimization compared target thickness layers versus electron energy. These optimized thicknesses were compared with published results by Ihsan et al.[Nucl. Instrum. Methods Phys. Res. B 264, 371-377 (2007)]. The second optimization evaluated electron source characteristics by changing the cathode shapes and electron energies. Electron sources studied included; (1) point sources, (2) uniform cylinders, and (3) nonuniform cylindrical shell geometries. The third optimization was used to assess the apex angle of the conical-hemisphere target. The goal of these optimizations was to produce 2D-dose anisotropy functions closer to unity. An overall optimized MEBXS was developed from this analysis. The results obtained from this model were compared to known characteristics of HDR {sup 125}I, LDR {sup 103}Pd, and Xoft Axxent electronic brachytherapy source (XAEBS) [Med. Phys. 33, 4020-4032 (2006)]. Results: The optimized anode thicknesses as a function of electron energy is fitted by the linear equation Y ({mu}m) = 0.0459X (keV)-0.7342. The optimized electron source geometry is obtained for a disk-shaped parallel beam (uniform cylinder) with 0.9 mm radius. The TG-43 distribution is less sensitive to the shape of the conical-hemisphere anode than the hemispherical anode. However, the optimized apex angle of conical-hemisphere anode was determined to be 60 deg. For the hemispherical targets, calculated radial dose function values at a distance of 5 cm were 0.137, 0.191, 0.247, and 0.331 for 40, 50, 60, and 80 keV electrons, respectively. These values for the conical-hemisphere targets are 0.165, 0.239, 0.305, and 0.412, respectively. Calculated 2D anisotropy functions values for the hemispherical target shape were F(1 cm, 0 deg.) = 1.438 and F(1 cm, 0 deg.) = 1.465 for 30 and 80 keV electrons, respectively. The corresponding values for conical-hemisphere targets are 1.091 and 1.241, respectively. Conclusions: A method for the characterizations of MEBXS using TG-43U1 dosimetric data using the MC MCNP4C has been presented. The effects of target geometry, thicknesses, and electron source geometry have been investigated. The final choices of MEBXS design are conical-hemisphere target shapes having an apex angle of 60 deg. Tungsten material having an optimized thickness versus electron energy and a 0.9 mm radius of uniform cylinder as a cathode produces optimal electron source characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Free electron terahertz wave radiation source with two-section periodical waveguide structures

We analyze a free electron terahertz wave radiation source with two-section periodical waveguide structure (PWS), where the first section (section-I) is used to pre-modulate the electron beam and the second section (section-II) is for terahertz wave generation. By means of theoretical analysis and numerical simulations, we demonstrate that the starting current density of the beam-wave interaction in section-II can be significantly reduced provided that the operation frequency is the harmonic of electron beam's pre-modulation frequency. This kind of source can generate relatively high power terahertz wave radiation but only need moderate beam current density. And it may have great potential application in developing the compact and high power terahertz wave radiation source.

07 ISOTOPE AND RADIATION SOURCES↗

First results from the new RIKEN superconducting electron cyclotron resonance ion source (invited)

The next generation heavy ion accelerator facility, such as the RIKEN radio isotope (RI) beam factory, requires an intense beam of high charged heavy ions. In the past decade, performance of the electron cyclotron resonance (ECR) ion sources has been dramatically improved with increasing the magnetic field and rf frequency to enhance the density and confinement time of plasma. Furthermore, the effects of the key parameters (magnetic field configuration, gas pressure, etc.) on the ECR plasma have been revealed. Such basic studies give us how to optimize the ion source structure. Based on these studies and modern superconducting (SC) technology, we successfully constructed the new 28 GHz SC-ECRIS, which has a flexible magnetic field configuration to enlarge the ECR zone and to optimize the field gradient at ECR point. Using it, we investigated the effect of ECR zone size, magnetic field configuration, and biased disk on the beam intensity of the highly charged heavy ions with 18 GHz microwaves. In this article, we present the structure of the ion source and first experimental results with 18 GHz microwave in detail.

43 PARTICLE ACCELERATORS↗

Jupiter's magnetotail as the source of interplanetary Jovian MeV electrons observed at earth

The source of interplanetary Jovian MeV electron enhancements observed at earth is found to be Jupiter's magnetotail. If an average solar wind speed of 400 km/sec is assumed, the main region of emission extends from about 1.0 AU downstream from Jupiter to about 2.0 AU beyond the planet. (If a value of 350 km/sec is assumed, it extends from about 0.4 AU to about 1.2 AU.) Individual 'active' zones are about 0.2 AU in length. It is proposed that interplanetary magnetic field line connection with the tail is the mechanism providing the Jovian electrons observed at earth.

Pesses, M. E.↗

On the role of electron energy distribution function in double frequency heating of electron cyclotron resonance ion source plasmas

Double frequency heating (DFH) is a tool to improve the output of highly charged ions particularly from modern electron cyclotron resonance ion source installations with very high RF-frequencies. In order to gain information on the DFH-mechanism and on the role of the lower injected frequency we have carried out a series of dedicated experiments where we have put emphasis on the creation of a discrete resonance surface also for this lower frequency. Our well-established method of inserting an emissive MD (metal-dielectric) liner into the plasma chamber of the source is used in these experiments as a tool of investigation. In this way, the electron temperature and density for both ECR zones is increased in a controlled manner, allowing conclusions on the role of the change of the electron-energy-distribution function with and without DFH.

43 PARTICLE ACCELERATORS↗

Electron distributions in the inner Jovian magnetosphere: Voyager 1 observations

Using several improvements in the analysis of the observations of the Low Energy Charged Particle (LECP) experiment on Voyager 1, electron phase space densities in the inner Jovian magnetosphere (5 - 10 R(sub J) were first calculated at constant first and second invariants (represented by mu and K, respectively), based on the LECP measurements. The calculated electron phase space density profiles show that in the inner Jovian magnetosphere there exist evident time and longitude variations, energetic electron injections, and present radial transport and distributed losses. To study the radial and pitch angle diffusions of Jovian electrons, we have calculated the phase space densities in the K-L space. It is found that the electron population in the inner Jovian magnetosphere seems to consist of two components: electrons radially diffusing from a main external source and electrons generated from local sources. The radially diffusing electrons have a relatively time stationary and isotropic distribution, while the locally created electrons mainly concentrate around the equatorial plane and have relatively lower energies, in comparison with the inward diffusing electrons. Consequently, the sources of precipitation losses to the ionosphere must be primarily electrons transported from outer sources, and the major precipitations occur in the inner magnetosphere (L less than 7.5 R(sub J). In the inner Jovian magnetosphere (L = 5 to approximately 10 R(sub J)) it is estimated that for electrons with magnetic moment mu = 300 MeV/G, the diffusion coefficient D is roughly 10(exp -8) to approximately 10(exp -6) R(exp 2)(sub J)/s, and the lifetime against the diffusion losses is of the order of 10(exp 4) to approximately 10(exp 6) s.

Ye, G.↗

Patient-Specific Monte Carlo-Based Dose-Kernel Approach for Inverse Planning in Afterloading Brachytherapy

Purpose: Brachytherapy planning software relies on the Task Group report 43 dosimetry formalism. This formalism, based on a water approximation, neglects various heterogeneous materials present during treatment. Various studies have suggested that these heterogeneities should be taken into account to improve the treatment quality. The present study sought to demonstrate the feasibility of incorporating Monte Carlo (MC) dosimetry within an inverse planning algorithm to improve the dose conformity and increase the treatment quality. Methods and Materials: The method was based on precalculated dose kernels in full patient geometries, representing the dose distribution of a brachytherapy source at a single dwell position using MC simulations and the Geant4 toolkit. These dose kernels are used by the inverse planning by simulated annealing tool to produce a fast MC-based plan. A test was performed for an interstitial brachytherapy breast treatment using two different high-dose-rate brachytherapy sources: the microSelectron iridium-192 source and the electronic brachytherapy source Axxent operating at 50 kVp. Results: A research version of the inverse planning by simulated annealing algorithm was combined with MC to provide a method to fully account for the heterogeneities in dose optimization, using the MC method. The effect of the water approximation was found to depend on photon energy, with greater dose attenuation for the lower energies of the Axxent source compared with iridium-192. For the latter, an underdosage of 5.1% for the dose received by 90% of the clinical target volume was found. Conclusion: A new method to optimize afterloading brachytherapy plans that uses MC dosimetric information was developed. Including computed tomography-based information in MC dosimetry in the inverse planning process was shown to take into account the full range of scatter and heterogeneity conditions. This led to significant dose differences compared with the Task Group report 43 approach for the Axxent source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser-IORT: a laser-driven source of relativistic electrons suitable for Intra-Operative Radiation Therapy of tumors

In a recent experiment [1] a high efficiency regime of stable electron acceleration to kinetic energies ranging from 10 to 40 MeV has been achieved. The main parameters of the electron bunches are comparable with those of bunches provided by commercial Radio-Frequency based Linacs currently used in Hospitals for Intra-Operative Radiation Therapy (IORT). IORT is an emerging technique applied in operating theaters during the surgical treatment of tumors. Performances and structure of a potential laser-driven Hospital accelerator are compared in detail with the ones of several commercial devices. A number of possible advantages of the laser based technique are also discussed.

43 PARTICLE ACCELERATORS↗

Development of Tandem, Double-Focusing, Electron Impact, Gas Source Mass Spectrometer for Measurement of Rare Double-Substituted Isotoplogues in Geochemistry

This project culminated in construction and delivery of the world’s first large-radius gas-source isotope ratio mass spectrometer that permits unparalleled analyses of the stable isotopic composition of methane gas. The instrument, referred to as the “Panorama” and installed at UCLA in March 2015, can now be used to determine the relative abundances of rare isotopic species of methane that serve as tracers of temperature of formation and/or subsequent processing of gas. With this technology we can begin to delineate different sources and sinks of methane isotopically in ways not possible until now.

47 OTHER INSTRUMENTATION↗

Study of Ion Generation by a ps-laser for External Injection into Electron Beam Ion Source

We investigated ion generation from Al, Ti, Cu, Nb and Ta target elements by a picosecond-laser in the range of 10 11 – 10 13 W/cm 2 power densities at the target surface. A ps-laser with 1.27 mJ maximum energy within a 8 ps pulse and repetition rate up to 400 Hz has been used to generate a laser-ablated plasma. Dependencies of ion current vs time, total charge of registered ions as well as ion kinetic energy distributions are characterized using a Faraday cup. Significant difference in ion current dynamics between first, second and following shots onto the same target spot was found for all five target elements. The total charge of ions registered by the Faraday cup increase linearly with increasing laser pulse energy and are almost independent on the target element and number of shots onto the same target spot for all five target elements studied. Target craters have been examined using a commercially available microscope (Nikon Eclipse LV150) and crater cross section areas were found to be in the range of 0.0076 – 0.0172 mm 2 within the first five shots onto the same target spot for different target elements. A linear dependence of crater cross section square on laser pulse energy has been observed for the Ta target. Ion energy distributions for all target elements have a plateau or a slight peak in the energy range of 10 - 100 eV and long low-intensity energy tail up to tens of keV.

43 PARTICLE ACCELERATORS↗

Electron-bombardment ion source operation using various gases.

Description of a modified flight-type SERT II ion thruster operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was found to be similar to that obtained previously with mercury. Mass spectrometer data indicated that xenon could be operated efficiently with no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor, but some future performance improvements may be realizable.

Byers, D. C.↗