Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Evaluation of a novel 4D in vivo dosimetry system

A prototype of a new 4D in vivo dosimetry system capable of simultaneous real-time position monitoring and dose measurement has been developed. The radiation positioning system (RADPOS) is controlled by a computer and combines two technologies: MOSFET radiation detector coupled with an electromagnetic positioning device. Special software has been developed that allows sampling position and dose either manually or automatically in user-defined time intervals. Preliminary tests of the new device include a dosimetric evaluation of the detector in {sup 60}Co, 6 MV, and 18 MV beams and measurements of spatial position stability and accuracy. In addition, the effect of metals and other materials on the performance of the positioning system has been investigated. Results show that the RADPOS system can measure in-air dose profiles that agree, on average, within 3%-5% of diode measurements for the energies tested. The response of the detector is isotropic within 1.6% (1 SD) with a maximum deviation of {+-}4.0% over 360 deg. The maximum variation in the calibration coefficient over field sizes from 6x6 to 25x25 cm{sup 2} was 2.3% for RADPOS probe with the high sensitivity MOSFET and 4.6% for the probe with the standard sensitivity MOSFET. Of the materials tested, only aluminum, lead, and brass caused shifts in the RADPOS read position. The magnitude of the shift varied between materials and size of the material sample. Nonmagnetic stainless steel (Grade 304) caused a distortion of less than 2 mm when placed within 10 mm of the detector; therefore, it can provide a reasonable alternative to other metals if required. The results of the preliminary tests indicate that the device can be used for in vivo dosimetry in {sup 60}Co and high-energy beams from linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probabilistic Impact Assessment and Software Tool Requirements

This research project will address the most pressing uncertainties in modeling and measuring the electric power grid effects of geomagnetic disturbances (GMDs) and the E3 portion of nuclear electromagnetic pulse (EMP). The primary goal is to help decision-makers in the electric power sector have the knowledge and tools they need to most effectively mitigate GMD effects on the North American electric grid, with a secondary focus on EMP response. Primary tasks will involve comprehensive modeling,

24 POWER TRANSMISSION AND DISTRIBUTION↗

Magnetohydrodynamics and Heat Transfer in a Free-Surface, Flowing Liquid Metal Experiment

This thesis examines magnetohydrodynamic (MHD) effects and heat transfer in free-surface, liquid metal flow. The interaction of the flow with the applied magnetic field introduces an anisotropy to the fluid motion, resulting in starkly different behavior depending on the orientation and strength of the applied magnetic field. The transition from a hydrodynamic state to an MHD state was experimentally found to be characterized by the interaction parameter, N = &sigma L B 2 /&rho v0 , crossing above 0.5. The experiment consisted of a channel 1 m in length, up to 16 cm in width and 1 to 2.5 cm in depth situated within an electromagnet capable of producing a uniform magnetic field up to 2.7 kG. The fluid velocity was measured with an array of 25 potential probes that resolved the spanwise velocity profile, while waves on the surface of the metal were monitored via a diagnostic that tracked the motion of a laser beam reflected off of the free surface. Lastly, the temperature response of the fluid was recorded with an array of 32 thermocouples embedded in the bottom of the channel and a mid-wavelength infrared camera used to image the free surface. Three distinct sets of experiments were performed to investigate the effects of the applied magnetic field on the dynamics within the flow, studying: 1) changes to vortices in the wake of a cylinder, 2) behavior of surface fluctuations due to the turbulent flow, and 3) vertical heat transfer resulting from heat deposition on the free surface. The first set of experiments examined the wake of a cylinder inserted into the flow with its axis parallel to the magnetic field. Measurements with the potential probes indicated that vortices in the wake became laminarized as the field was increased due to the alignment of the injected vorticity with the applied field. The second set of experiments showed that surface fluctuations were suppressed at high magnetic fields, but the precise nature of the damping depended on the orientation of the applied field. Lastly, when heat was injected at the free surface via a resistive heater, the temperature response of the fluid was found to vary considerably depending on the strength and direction of the applied field. In all experiments, it was observed that the angle between the vorticity of structures in the flow and the applied magnetic field dictated the macroscopic behavior of the fluid. This work provides the first experimental results of several phenomena associated with free-surface, liquid metal flows in an applied magnetic field. Further, the results have direct implications for proposed flowing liquid metal divertors for fusion reactors, and offer insight into the nature of turbulent MHD flows.

fusion↗

Final Report - Few-Body Studies Using Electromagnetic Interactions

The work discussed here is an extension of work previously funded by U.S. Department of Energy Grant DE-FG02-97ER41025. Measurements of charged pion photoproduction from deuterium using the Laser Electron Gamma Source (LEGS) at the Brookhaven National Laboratory previously made by us, as members of the LEGS Collaboration, resulted in the most interesting result of two decades of work. By measuring the production of a charged pion (π + ) in coincidence with an emitted photon we observed structures in the residual two-nucleon system. These indicated the existence of rare, long-lived states not explicable by standard nuclear theory; they suggested a set of configurations not explicable in terms of a nucleon-nucleon pair. The existence of such “exotic” structures has formed the foundation for most of the work that has ensued. Several measurements at various laboratories have supported, but not proved, the existence of these exotic states. The rarity of these states made their existence undetectable in most previous measurements. Only by observing characteristic signatures of such states (i.e., decay photons), by using very specific kinematics which isolate certain reaction products, or by measuring polarization-dependent observables. During the period of this grant we pursued and made progress on the development of experiments to be performed at the High Intensity Gamma Source (HIGS) of the Tri Universities Nuclear Laboratory (TUNL). Our understanding of photon- and electron-induced nuclear reactions depends on understanding of the basic electron and photon interaction. Recently, the issue of two-photon contributions has arisen in the context of deeply inelastic electron scattering. One way to address this is to measure asymmetries in the Bethe-Heitler ee process. We also made progress in developing the detectors required to measure these asymmetries at HIGS. During the last several years the apparent discrepancy between the size of the proton as measured using electrons and that as measured using muons has received a great deal of attention. Working with colleagues at the Jefferson Laboratory (JLAB) we showed that the apparent discrepancy was almost surely the result of mistakes in the statistical analysis of electron scattering data, that there is almost surely no discrepancy.

43 PARTICLE ACCELERATORS↗

High Q{sup 2} behavior of the electromagnetic form factors in the relativistic hypercentral constituent quark model

The ratio R{sub p} between the electric and magnetic proton form factors has been recently measured at Jefferson Lab up to Q{sup 2}=8.5 GeV{sup 2}. We have extended the calculation of the nucleon form factors with the hypercentral constituent quark model and compared them with the data on R{sub p} and on the Q{sup 2} behavior of the ratio Q{sup 2}F{sub 2}/F{sub 1}. In both cases, the theoretical curves agree with the experimental points.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photoconductive and electro-optic effects in (Cd,Mg)Te single crystals measured in an experiment-on-chip configuration

We present our studies on both photoconductive (PC) and electro-optic (EO) responses of (Cd,Mg)Te single crystals. In an In-doped Cd 0.92 Mg 0.08 Te single crystal, subpicosecond electrical pulses were optically generated via a PC effect, coupled into a transmission line, and, subsequently, detected using an internal EO sampling scheme, all in the same (Cd,Mg)Te material. For photo-excitation and EO sampling, we used femtosecond optical pulses generated by the same Ti:sapphire laser with the wavelength 410 and 820 nm, respectively. The shortest transmission line distance between the optical excitation and EO sampling points was 75 μm. By measuring the transient waveforms at different distances from the excitation point, we calculated the transmission-line complex propagation factor, as well as the THz frequency attenuation factor and the propagation velocity, all of which allowed us to reconstruct the electromagnetic transient generated directly at the excitation point, showing that the original PC transient was subpicosecond in duration with a fall time of ~500 fs. Finally, the measured EO retardation, together with the amount of the electric-field penetration, allowed us to determine the magnitude of the internal EO effect in our (Cd,Mg)Te crystal. The obtained THz-frequency EO coefficient was equal to 0.4 pm/V, which is at the lower end among the values reported for CdTe-based ternaries, due to a twinned structure and misalignment of the tested (Cd,Mg)Te crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoproduction of J/psi and of High Mass e+e- in Ultra-Peripheral Au+Au Collisions at s**(1/2) = 200 GeV

We present the first measurement of photoproduction of J/{psi} and of two-photon production of high-mass e{sup +}e{sup -} pairs in electromagnetic (or ultra-peripheral) nucleus-nucleus interactions, using Au + Au data at {radical}s{sub NN} = 200 GeV. The events are tagged with forward neutrons emitted following Coulomb excitation of one or both Au* nuclei. The event sample consists of 28 events with m{sub e{sup +}e{sup -}} > 2 GeV/c{sup 2} with zero like-sign background. The measured cross sections at midrapidity of d{sigma}/dy (J/{psi} + Xn,y = 0) = 76 {+-} 33(stat) {+-} 11(syst) {mu}b and d{sup 2}{sigma}/dm dy(e{sup +}e{sup -} + Xn, y = 0) = 86 {+-} 23(stat) {+-} 16(syst) {mu}b/(GeV/c{sup 2}) for m{sub e{sup +}e{sup -}} {element_of} [2.0,2.8] GeV/c{sup 2} have been compared and found to be consistent with models for photoproduction of J/{psi} and QED based calculations of two-photon production of e{sup +}e{sup -} pairs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Timing with shower maximum detectors based on pixelated micro-channel plates

Future calorimeters and shower maximum detectors at high luminosity colliders need to be highly radiation resistant and very fast. One exciting option for such a detector is a calorimeter composed of a secondary emitter as the active element. Here, we outline the study and development of a secondary emission calorimeter prototype using micro-channel plates (MCP) as the active element, which directly amplify the electromagnetic shower signal. We also demonstrate the feasibility of using a bare MCP within an inexpensive and robust housing without the need for any photo cathode, which is a key requirement for high radiation tolerance. Test beam measurements of the prototype were performed with 120 GeV primary protons and secondary beams at the Fermilab Test Beam Facility, demonstrating basic calorimetric measurements and precision timing capabilities. Using multiple pixel readout on the MCP, we demonstrate a transverse spatial resolution of 0.8 mm, and time resolution better than 40 ps for electromagnetic showers.

47 OTHER INSTRUMENTATION↗

A large volume uniform plasma generator for the experiments of electromagnetic wave propagation in plasma

A large volume uniform plasma generator is proposed for the experiments of electromagnetic (EM) wave propagation in plasma, to reproduce a 'black out' phenomenon with long duration in an environment of the ordinary laboratory. The plasma generator achieves a controllable approximate uniform plasma in volume of 260 mm Multiplication-Sign 260 mm Multiplication-Sign 180 mm without the magnetic confinement. The plasma is produced by the glow discharge, and the special discharge structure is built to bring a steady approximate uniform plasma environment in the electromagnetic wave propagation path without any other barriers. In addition, the electron density and luminosity distributions of plasma under different discharge conditions were diagnosed and experimentally investigated. Both the electron density and the plasma uniformity are directly proportional to the input power and in roughly reverse proportion to the gas pressure in the chamber. Furthermore, the experiments of electromagnetic wave propagation in plasma are conducted in this plasma generator. Blackout phenomena at GPS signal are observed under this system and the measured attenuation curve is of reasonable agreement with the theoretical one, which suggests the effectiveness of the proposed method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of an Ultrafast Harmonic Resonant RF Kicker

An Energy Recovery Linac (ERL) based multi-turn electron Circulator Cooler Ring (CCR) is envisaged in the proposed Jefferson Lab Electron Ion Collider (JLEIC) to cool the ion bunches with high energy (55 MeV), high current (1.5 A), high repetition frequency (476.3 MHz), high quality magnetized electron bunches. A critical component in this scheme is a pair of ultrafast kickers for the exchange of electron bunches between the ERL and the CCR. The ultrafast kicker should operate with the rise and fall time in less than 2.1 ns, at the repetition rate of ~10s MHz, and should be able to run continuously during the whole period of cooling. These -and-fall time being combined together, are well beyond the state-of-art of traditional pulsed power supplies and magnet kickers. To solve this technical challenge, an alternative method is to generate this high repetition rate, fast rise-and-fall time short pulse continuous waveform by summing several finite number of (co)sine waves at harmonic frequencies of the kicking repetition frequency, and these harmonic modes can be generated by the Quarter Wave Resonater (QWR) based multifrequency cavities. Assuming the recirculator factor is 10, 10 harmonic modes (from 47.63 MHz to 476.3 MHz) with proper amplitudes and phases, plus a DC offset are combined together, a continuous short pulse waveform with the rise-and-fall time in less than 2.1 ns, repetition rate of 47.63 MHz waveform can be generated. With the compact and matured technology of QWR cavities, the total cost of both hardware development and operation can be reduced to a modest level. Focuse on the technical scheme, three main topics will be discussed in this thesis: the synthetization of the kicking pulse, the design and optimization of the deflecting QWR multi-integer harmonic frequency resonator and the fabrication and bench measurements of a half scale copper prototype. In the kicking pulse synthetization part, we begin with the Fourier Series expansion of an ideal square pulse, and get a Flat-Top waveform which will give a uniform kick over the bunch length of the kicked electron bunches, thus the transverse emittance of these kicked electron bunches can be maintained. By using two identical kickers with the betatron phase advance of 180 degree or its odd multiples, the residual kick voltage wave slopes at the unkicked bunch position will be totally cancelled out. Flat-Top waveform combined with two kicker scheme, the transverse emittance of the cooling electron bunches will be conserved during the whole injection, recirculation, and ejection processes. In the cavity design part, firstly, the cavity geometry is optimized to get high transverse shunt impedance thus less than 100 W of RF losses on the cavity wall can be achieved for all these 10 harmonic modes. To support all these 10 harmonic modes, group of four QWRs are adopted with the mode distribution of 5:3:1:1. In the multi-frequency cavities such as the five-mode-cavity and the three-mode-cavity, tunings are required to achieve the design frequencies for each mode. Slight segments of taper design on the inner conductor help to get the frequencies to be exactly on the odd harmonic modes. Stub tuners equal to the number of resonant modes are inserted to the outer conductor wall to compensate the frequency shifts due manufacturing errors and other perturbations during the operation such as the change of the cavity temperature. Single loop couple is designed for all harmonic modes in each cavity. By adjusting its loop size, position and rotation, it is possible to get the fundamental mode critical coupled and other higher harmonic modes slightly over coupled. A broadband circulator will be considered for absorbing the reflected power. Finally in this part, multipole field components due to the asymmetric cylindrical structure around the beam axis of the cavity as well as the beam-induced higher order mode (HOM) issues will be analyzed and discussed in this thesis. A half-scale copper prototype cavity (resonant frequencies from 95.26 MHz to 857.34 MHz) was fabricated to validate the electromagnetic characteristics. With this half scale prototype, the tuning processes of multiple harmonic frequencies, unloaded quality factor measurements of each mode, and bead-pull measurements are performed. The bench measurement results matched well with the simulation results, which have validated our cavity design and construction methods. Finally, a simple mode combining experiment with five separate signal generators was performed on this prototype cavity and the desired fast rise/fall time (1.2 ns), high repetition rate (95.26 MHz) waveform was captured, which finally proved our design of this ultrafast harmonic kicker.

43 PARTICLE ACCELERATORS↗

A Probabilistic Radar Forward Model for Branched Planar Ice Crystals

Polarimetric radar measurements provide information about ice particle growth and offer the potential to evaluate and better constrain ice microphysical models. To achieve these goals, one must map the ice particle physical properties (e.g., those predicted by a microphysical model) to electromagnetic scattering properties using a radar forward model. Simplified methods of calculating these scattering properties using homogeneous, reduced-density spheroids produce large errors in the polarimetric radar measurements, particularly for low-aspect-ratio branched planar crystals. To overcome these errors, an empirical method is introduced to more faithfully represent branched planar crystal scattering using scattering calculations for a large number of detailed shapes. Additionally, estimates of the uncertainty in the scattering properties, owing to ambiguity in the crystal shape given a set of bulk physical properties, are also incorporated in the forward model. To demonstrate the utility of the forward model developed herein, the radar variables are simulated from microphysical model output for an Arctic cloud case. The simulated radar variables from the empirical forward model are more consistent with the observations compared to those from the homogeneous, reduced-density-spheroid model, and have relatively low uncertainty.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the photon identification efficiencies with the ATLAS detector using LHC Run 2 data collected in 2015 and 2016

The efficiency of the photon identification criteria in the ATLAS detector is measured using 36.1 fb 1 to 36.7 fb 1 of pp collision data at √s = 13 TeV collected in 2015 and 2016. The efficiencies are measured separately for converted and unconverted isolated photons, in four different pseudorapidity regions, for transverse momenta between 10 GeV and 1.5 TeV. The results from the combination of three data-driven techniques are compared with the predictions from simulation after correcting the variables describing the shape of electromagnetic showers in simulation for the average differences observed relative to data. Data-to-simulation efficiency ratios are determined to account for the small residual efficiency differences. These factors are measured with uncertainties between 0.5% and 5% depending on the photon transverse momentum and pseudorapidity. The impact of the isolation criteria on the photon identification efficiency, and that of additional soft pp interactions, are also discussed. The probability of reconstructing an electron as a photon candidate is measured in data, and compared with the predictions from simulation. In conclusion, the efficiency of the reconstruction of photon conversions is measured using a sample of photon candidates from Z → μμγ events, exploiting the properties of the ratio of the energies deposited in the first and second longitudinal layers of the ATLAS electromagnetic calorimeter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Silicon Absolute X-Ray Detectors

The responsivity of silicon photodiodes having no loss in the entrance window, measured using synchrotron radiation in the 1.75 to 60 keV range, was compared to the responsivity calculated using the silicon thickness measured using near-infrared light. The measured and calculated responsivities agree with an average difference of 1.3%. This enables their use as absolute x-ray detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report DE-FE0031785 Mohsen Ahmadian, Ph.D. Demonstration of Proof of Concept of a Multiphysics Approach for Real-Time Remote Monitoring of Dynamic Changes in Pressure and Salinity in Hydraulically Fractured Networks

Hydraulic fracturing has evolved into a multistep process with varying flow rates, carrier fluids (e.g., gel or slickwater), proppant loadings, and proppant grain sizes. As a result, primary recovery from a hydraulically fractured tight-oil reservoir is often a tiny fraction of the original oil in place, ranging between 5 and 10%. As stated in the FOA1990, “part of this problem is due to the inability of current well completion processes to effectively stimulate the entire reservoir volume in contact with the wellbore. Innovative technologies are needed that can help improve the effectiveness of reservoir completion methods, maximize stimulated reservoir volumes, and optimize recovery over the entire producing life span of a well”. We first need to enhance the current fracture diagnostic techniques to improve a well-completion design. However, detecting and delineating a subsurface hydraulic fracture is extremely difficult because the induced fracture network is only fractionally propped, and these propped fractures are generally very thin. Microseismic and tiltmeter monitoring techniques can provide information on the fracture extent but provide little or no information on the movement and final distribution of proppant or production fluids. On the other hand, electromagnetic (EM) imaging has shown the capability to monitor proppant distribution throughout the fracture area, especially in the presence of Electrically Active Proppants (EAPs). A previous EM survey of hydraulic fracturing at the Devine Fracture Pilot Site (DFPS) and subsequent EM code developments demonstrated this survey as a robust technique to remotely interrogate the extent of the EAP-filled hydraulic fracture during its propagation. The objectives of the project were threefold: (1) to capitalize on the material properties of an EAP to demonstrate remote monitoring of relative changes in pressure, pressure, and flow that are commonly encountered during production from a hydraulically fractured reservoir; (2) to evaluate EM imaging tools, to achieve Objective 1 in near real-time; and (3) to develop a multi-physics joint inversion approach to precisely predict flow patterns and physiochemical changes within an EAP-filled fracture network. This research project was built upon our previous work at the Devine Test Site managed by the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT-Austin). It also leveraged a significant investment from the Advanced Energy Consortium (AEC) to address the DOE's interest in subsurface flow, containment, and characterization by multiple signals. This three-year and three-month project succeeded in demonstrating the feasibility of a real-time dynamic fluid flow mapping technique at Technology Readiness Level 5 (TRL5) by utilizing a commercially available surface-based Controlled-Source Electromagnetic (CSEM) method (Objectives 1, 2). We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, the observed electric field in our study is influenced by bottomhole pressure, flow rate, and salinity, which is demonstrated by comparing these parameters with the electrical field potentials. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce the whole measured electric field magnitudes. Preliminary estimates showed that including Streaming Potential (SP) in our geophysical model is likely needed to reduce the simulation misfit.

02 PETROLEUM↗

Operation of the CAPRICE electron cyclotron resonance ion source applying frequency tuning and double frequency heating

The properties of the electromagnetic waves heating the electrons of the ECR ion sources (ECRIS) plasma affect the features of the extracted ion beams such as the emittance, the shape, and the current, in particular for higher charge states. The electron heating methods such as the frequency tuning effect and the double frequency heating are widely used for enhancing the performances of ECRIS or even for the routine operation during the beam production. In order to better investigate these effects the CAPRICE ECRIS has been operated using these techniques. The ion beam properties for highly charged ions have been measured with beam diagnostic tools. The reason of the observed variations of this performance can be related to the different electromagnetic field patterns, which are changing inside the plasma chamber when the frequency is varying.

43 PARTICLE ACCELERATORS↗

MEASUREMENT OF COSMIC MICROWAVE BACKGROUND POLARIZATION POWER SPECTRA FROM TWO YEARS OF BICEP DATA

Background Imaging of Cosmic Extragalactic Polarization (BICEP) is a bolometric polarimeter designed to measure the inflationary B-mode polarization of the cosmic microwave background (CMB) at degree angular scales. During three seasons of observing at the South Pole (2006 through 2008), BICEP mapped {approx}2% of the sky chosen to be uniquely clean of polarized foreground emission. Here, we present initial results derived from a subset of the data acquired during the first two years. We present maps of temperature, Stokes Q and U, E and B modes, and associated angular power spectra. We demonstrate that the polarization data are self-consistent by performing a series of jackknife tests. We study potential systematic errors in detail and show that they are sub-dominant to the statistical errors. We measure the E-mode angular power spectrum with high precision at 21 <= l <= 335, detecting for the first time the peak expected at l {approx} 140. The measured E-mode spectrum is consistent with expectations from a LAMBDACDM model, and the B-mode spectrum is consistent with zero. The tensor-to-scalar ratio derived from the B-mode spectrum is r = 0.02{sup +0.31}{sub -0.26}, or r < 0.72 at 95% confidence, the first meaningful constraint on the inflationary gravitational wave background to come directly from CMB B-mode polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon position measure

The positive operator valued measure (POVM) for a photon counting array detector is derived and found to equal photon flux density integrated over pixel area and measurement time. Since photon flux density equals number density multiplied by the speed of light, this justifies theoretically the observation that a photon counting array provides a coarse-grained measurement of photon position. The POVM obtained here can be written as a set of projectors onto a basis of localized states, consistent with the description of photon position in a recent quantum imaging proposal [Tsang, Phys. Rev. Lett. 102, 253601 (2009)]. The wave function that describes a photon counting experiment is the projection of the photon state vector onto this localized basis. Collapse is to the electromagnetic vacuum and not to a localized state, thus violating the textbook rules of quantum mechanics but compatible with the theory of generalized observables and the nonlocalizability of an incoming photon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type. Conclusions: It is concluded that gadolinium based contrast agents, iron oxide particles, and single walled carbon nanotubes have little intrinsic merit as thermoacoustic contrast agents. Simple electrolytes such as saline which yield high contrast based on ionic conductivity provide much higher dielectric contrast per unit solute concentration and are likely to be significantly more effective as contrast agents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗