Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Effect of net surface charge on particle sizing and material recognition by using phase Doppler anemometry

By taking net surface charge into consideration, the scattering field of particles illuminated by dual laser beams of phase Doppler anemometry (PDA) is computed based on Mie's theory, and the effect of net surface charge on the phase-diameter relationship and the phase ratio is studied. It is found that the phase-diameter relationship and the relationship between the phase ratio and the refractive index of charged particles could be significantly different from those of uncharged particles, which would lead to errors in particle sizing and the measurement of refractive indices. A method of recognizing charged particles and determining the value of their surface conductivity, which is related to net surface charge, is proposed by utilizing the effect of net surface charge on the measurement of refractive indices using PDA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing warm atmospheric boundary layer over land by combining Raman and Doppler lidar measurements

PBL plays a critical role in the atmosphere by transferring heat, moisture, and momentum. The warm PBL has a distinct diurnal cycle including daytime convective mixing layer (ML) and nighttime residual layer developments. Thus, for PBL characterization and process study, simultaneous determinations of PBL height (PBLH) and ML height (MLH) are necessary. Here, new approaches are developed to provide reliable PBLH and MLH to characterize warm PBL evolution. The approaches use Raman lidar (RL) water vapor mixing ratio (WVMR) and Doppler lidar (DL) vertical velocity measurements at the Southern Great Plains (SGP) atmospheric observatory, which was established by the Atmospheric Radiation Measurement (ARM) user facility. Compared with widely used lidar aerosol measurements for PBLH, WVMR is a better trace for PBL vertical mixing. For PBLH, the approach classifies PBL water vapor structures into a few general patterns, then uses a slope method and dynamic threshold method to determine PBLH. For MLH, wavelet analysis is used to re-construct 2-D variance from DL vertical wind velocity measurements according to the turbulence eddy size to minimize the impacts of gravity wave and eddy size on variance calculations; then, a dynamic threshold method is used to determine MLH. Remotely-sensed PBLHs and MLHs are compared with radiosonde measurements based on the Richardson number method. Good agreements between them confirm that the proposed new algorithms are reliable for PBLH and MLH characterization. The algorithms are applied to warm seasons’ RL and ML measurements at the SGP site for five years to study warm season PBL structure and processes. The weekly composited diurnal evolutions of PBLHs and MLHs in warm climate were provided to illustrate diurnal and seasonal PBL evolutions. This reliable PBLH and MLH dataset will be valuable for PBL process study, model evolution, and PBL parameterization improvement.

54 ENVIRONMENTAL SCIENCES↗

Physiological impact of nanoporous acupuncture needles: Laser Doppler perfusion imaging in healthy volunteers

Recently, porous acupuncture (PA), which is anodized to increase its surface area for higher stimulation intensity, was developed and showed significantly improved therapeutic effects with more comfort as compared with original acupuncture (OA) in vivo. However, the impact of PA on the change of local blood flow as well as its efficacy and acceptability has not yet been confirmed in a clinical trial. In a randomized, controlled crossover clinical trial, we investigated the effects of PA on the change in local blood flow using laser Doppler perfusion imaging and considered the sensation of pain intensity and discomfort severity using a visual analogue scale (VAS) to explore its physiological impact and the possibility of PA in clinical use. Twenty-one healthy participants were randomly treated with PA or OA on one side of Zusanli (ST36) and each participant served as his or her own control. Baseline local blood flow and galvanic skin response (GSR) were obtained for 5 min and acupuncture interventions were subsequently performed. Next, local blood flow and GSR were subsequently obtained for 10 min after insertion, 10 min after manipulation, and 5 min after the withdrawal of acupuncture. At the end of the experiment, participants were asked to indicate the sensation of pain intensity at each session of insertion, retention, manipulation, and withdrawal as well as the overall pain intensity and discomfort severity. PA significantly increased the local blood flow as compared with OA and there was no significant difference in GSR between patients treated with PA versus OA in each phase of insertion and manipulation. No significant difference in pain intensity or discomfort severity was found during manipulation, retention, or withdrawal of acupuncture. These results indicate that PA increases local blood flow, which can be closely related to the observed enhanced performance, without any associated discomfort or pain, suggesting its applicability in clinical practice.

59 BASIC BIOLOGICAL SCIENCES↗

CROCUS Urban Canyons - Space Science and Engineering Center (SPARC) Doppler lidar data

This is the netCDF format output from the Halo Photonics Streamline XR Doppler lidar that was deployed next to the Space Science and Engineering Center (SPARC) trailer at the University of Illnois-Chicago greenhouse parking lot during CROCUS Urban Canyons. The purpose of collecting this dataset is to provide vertical and horizontal wind profiles for studying the characteristics of turbulence over the urban canyon of Chicago. This data contains the radial velocity, intensity, and backscatter from the vertical profile, range height indicator, and sector scans that were performed over both Intensive Operating Period 1 and 2 of CROCUS Urban Canyons. There are four different types of files: * The Range Height Indicator (RHI) files contain scans that are along a constant azimuth, spanning the entire hemisphere of elevation values above the surface. * The Velocity Azimuth Display (VAD) files contain the raw radial velocity data from the 6-beam, 60 degree scans. * The User1 files contain stacked Plan Position Indicator scans over a 45 degree quadrant over downtown Chicago. * The Stare files contain vertically pointing scans. These are standard netCDF files that can be opened using xarray. The VAD scans can be processed from their raw radial velocities to horizontal wind speeds with the Atmospheric data Community Toolkit (https://arm-doe.github.io/ACT/).

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC WINDS↗

Acoustic Doppler Current Profiler Surveys of Velocity Downstream of Albeni Falls Dam

The U.S. Army Corps of Engineers (USACE), Seattle District, is studying the potential to locate fish bypass systems at Albeni Falls Dam. The USACE requested Pacific Northwest National Laboratory (PNNL) to survey velocity magnitude and direction in the dam tailrace. The empirical data collected will be used to support future numerical modeling, physical modeling, and evaluation of fish bypass system alternatives. In May 2010, PNNL conducted velocity surveys of the Albeni Falls Dam using a boat-mounted acoustic Doppler current profiler. The surveys were conducted over three days (May 25 through 27). During the survey period, total river discharge at the dam varied between 30.2 and 31.0 kcfs. A small amount of spill discharge, 2 kcfs, was present on two days (May 26 and 27). This report presents data plots showing measured velocity direction and magnitude averaged over the entire depth and over 5-ft depth increments from 5 to 30 ft.

13 HYDRO ENERGY↗

Experimental Study of Microparticle Adhesion and Resuspension with Laser Doppler Vibrometry

Microparticle adhesion and resuspension were studied where Laser Doppler Vibrometry, digital microscopy, and high speed imaging were used to characterize the rate of microparticle resuspension due to mechanical impulse forces. The effects of capillary condensation, particle size, electrostatic adhesion, and van der Waals forces were quantified. The effects of inter-particle cohesive bonds on aggregate-surface adhesion were also observed and quantified. These observations suggest clusters of biological spores may resist resuspension forces due to internal energy dissipation. Experimental methods developed here can be directly applied to trace detection and remediation of chemical, biological, radiological, nuclear, and explosive materials (CBRNE) and are recommended for studying spore resuspension. Semi-empirical relationships presented in this work can also be integrated into existing hazard prediction and assessment capability tools to incorporate the effects of resuspension in computational models. Lastly, this work constitutes a validation data set for discrete element models (DEM) developed at Sandia National Laboratories which could be used to model microparticle adhesion and resuspension.

Hubbard, Joshua Allen↗

Testing for the Photon Doppler Broadening Data Sampling Bug in MCNP5/X

MCNP5/X has the capability to perform photon Doppler broadening to incorporate the effect of bound electrons on photon scattering. This effect is generally important if energy spectra or detector responses are desired for photons in the tens to hundreds of keY energy range. In the Fall of 2011, a diligent MCNP user noticed that the sampling routines in MCNP were inconsistent with t he data for sampling which atomic shell t he electron is bound. The data are provided in probability density function (PDF) format, whereas MCNP sampled the data as if they are in a cumulative density function (CDF) format, leading to erroneous results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Doppler Velocimetry of Current Driven Spin Helices in a Two-Dimensional Electron Gas

Spins in semiconductors provide a pathway towards the development of spin-based electronics. The appeal of spin logic devices lies in the fact that the spin current is even under time reversal symmetry, yielding non-dissipative coupling to the electric field. To exploit the energy-saving potential of spin current it is essential to be able to control it. While recent demonstrations of electrical-gate control in spin-transistor configurations show great promise, operation at room temperature remains elusive. Further progress requires a deeper understanding of the propagation of spin polarization, particularly in the high mobility semiconductors used for devices. This dissertation presents the demonstration and application of a powerful new optical technique, Doppler spin velocimetry, for probing the motion of spin polarization at the level of 1 nm on a picosecond time scale. We discuss experiments in which this technique is used to measure the motion of spin helices in high mobility n-GaAs quantum wells as a function of temperature, in-plane electric field, and photoinduced spin polarization amplitude. We find that the spin helix velocity changes sign as a function of wave vector and is zero at the wave vector that yields the largest spin lifetime. This observation is quite striking, but can be explained by the random walk model that we have developed. We discover that coherent spin precession within a propagating spin density wave is lost at temperatures near 150 K. This finding is critical to understanding why room temperature operation of devices based on electrical gate control of spin current has so far remained elusive. We report that, at all temperatures, electron spin polarization co-propagates with the high-mobility electron sea, even when this requires an unusual form of separation of spin density from photoinjected electron density. Furthermore, although the spin packet co-propagates with the two-dimensional electron gas, spin diffusion is strongly suppressed by electron-electron interactions, leading to remarkable resistance to diffusive spreading of the drifting pulse of spin polarization. Finally, we show that spin helices continue propagate at the same speed as the Fermi sea even when the electron drift velocity exceeds the Fermi velocity of 107 cm s -1 .

36 MATERIALS SCIENCE↗

Documentation and Instructions for Running Two Python Scripts that Aid in Setting up 3D Measurements using the Polytec 3D Scanning Laser Doppler Vibrometer

Sandia National Laboratories has recently purchased a Polytec 3D Scanning Laser Doppler Vibrometer for vibration measurement. This device has proven to be a very nice tool for making vibration measurements, and has a number of advantages over traditional sensors such as accelerometers. The non-contact nature of the laser vibrometer means there is no mass loading due to measuring the response. Additionally, the laser scanning heads can position the laser spot much more quickly and accurately than placing an accelerometer or performing a roving hammer impact. The disadvantage of the system is that a significant amount of time must be invested to align the lasers with each other and the part so that the laser spots can be accurately positioned. The Polytec software includes a number of nice tools to aid in this procedure; however, certain portions are still tedious. Luckily, the Polytec software is readily extensible by programming macros for the system, so tedious portions of the procedure can be made easier by automating the process. The Polytec Software includes a WinWrap (similar to Visual Basic) editor and interface to run macros written in that programming language. The author, however, is much more proficient in Python, and the latter also has a much larger set of libraries that can be used to create very complex macros, while taking advantage of Python’s inherent readability and maintainability.

47 OTHER INSTRUMENTATION↗

Anomaly Detection In Additively Manufactured Parts Using Laser Doppler Vibrometery

Additively manufactured parts are susceptible to non-uniform structure caused by the unique manufacturing process. This can lead to structural weakness or catastrophic failure. Using laser Doppler vibrometry and frequency response analysis, non-contact detection of anomalies in additively manufactured parts may be possible. Preliminary tests show promise for small scale detection, but more future work is necessary.

42 ENGINEERING↗

Doppler Lidar Wind Value-Added Product

Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

54 ENVIRONMENTAL SCIENCES↗

Photonic-Doppler-Velocimetry, Paraxial-Scalar Diffraction Theory and Simulation

In this report I describe current progress on a paraxial, scalar-field theory suitable for simulating what is measured in Photonic Doppler Velocimetry (PDV) experiments in three dimensions. I have introduced a number of approximations in this work in order to bring the total computation time for one experiment down to around 20 hours. My goals were: to develop an approximate method of calculating the peak frequency in a spectral sideband at an instant of time based on an optical diffraction theory for a moving target, to compare the ‘measured’ velocity to the ‘input’ velocity to gain insights into how and to what precision PDV measures the component of the mass velocity along the optical axis, and to investigate the effects of small amounts of roughness on the measured velocity. This report illustrates the progress I have made in describing how to perform such calculations with a full three dimensional picture including tilted target, tilted mass velocity (not necessarily in the same direction), and small amounts of surface roughness. With the method established for a calculation at one instant of time, measured velocities can be simulated for a sequence of times, similar to the process of sampling velocities in experiments. Improvements in these methods are certainly possible at hugely increased computational cost. I am hopeful that readers appreciate the insights possible at the current level of approximation.

42 ENGINEERING↗

Remote Sensing of Complex Flows by Doppler Wind Lidar: Issues and Preliminary Recommendations

Remote sensing of winds using lidar has become popular and useful in the wind energy industry. Extensive experience has been gained with using lidar for applications including land-based and offshore resource assessment, plant operations, and turbine control. Prepared by members of International Energy Agency Task 32, this report describes the state of the art in the use of Doppler wind lidar for resource assessment in complex flows. The report will be used as input for future recommended practices on this topic.

17 WIND ENERGY↗

Doppler Broadening Resonance Correction for Free-gas Scattering in MCNP6.2

The traditional treatment for epithermal neutron scattering in continuous-energy Monte Carlo codes is the free-gas scattering model with the scattering cross-section assumed constant in energy. Ouislomen and Sanchez demonstrated in 1991 that scattering resonances can cause significant departures from the free-gas model, and Becker proposed a correction to the Monte Carlo free-gas scattering model in 2009. Becker’s Doppler Broadening Resonance Correction was tested in mcnp5 in 2011 and recently implemented in mcnp6.2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photonic Doppler Velocimetry for Valve Analysis and Surveillance

This study is an experimental evaluation to measure and surveil the velocity of stainless steel (Carpenter 455) pistons within a forged 21-6-9 stainless steel valve body. The velocity of the piston “stroke” will be identified using Photonic Doppler Velocimetry (PDV). The piston velocity will be the measured variable of interest. The outcome of this testing series provides further understanding to whether the extracted piston velocity can provide enough information to determine valve integrity. PDV has been identified as a diagnostic of interest as it can detect surface motion at high speeds with reliable accuracy. Through preliminary studies conducted with velocity interferometer system for any reflector (VISAR), the velocity of the piston is expected to stroke with a speed of 135 m/s. The PDV technique is much more reliable and repeatable than the VISAR technique because of its high-speed precision and accuracy, so it will not only validate the preliminary data, but also provide a testing technique that is capable of being used in future valve qualification efforts. The initial testing was completed using valves that were assembled per qualified procedures in a pristine condition. These initial tests were conducted to provide baseline data. This baseline data was then compared to data collected from valves where man-made defects were introduced. These defects are discussed in later sections. Lastly, actuators used to operate the valves were loaded with varied amounts of high explosives to identify if velocity is a function of the amount of explosive in an actuator. These parameters were adjusted to conclusively determine and identify if PDV can be used as a method to assess valve integrity. It was concluded through the testing discussed in this paper that in fact, PDV is capable of measuring the differences in piston velocities based on varied parameters. As far as understanding the PDV accuracy of the measured differences, this is ongoing and will have to be assessed in continued testing series.

42 ENGINEERING↗

Magnetic Field Vector Measurements Using Doppler-Free Saturation Spectroscopy

Experimentally measuring the magnetic-field vector topology in low-cost fusion-concept devices will provide critical information required to optimize and accelerate the development of those concepts for economical fusion energy. The magnetic-field measurement techniques most commonly used in modern tokamaks, i.e., beam-emission spectroscopy and optical emission spectroscopy, are not suitable below 5000 Gauss due to a lack of sensitivity. To diagnose magnetic field relevant to some of the ARPA-E-supported fusion concepts (50 to 1000 Gauss), a novel approach is required. Doppler-free saturation spectroscopy (DFSS) is a pump/probe laser-based technique and has been successfully demonstrated in the laboratory to provide a magnetic-field measurement accuracy of <10 Gauss. DFSS is implemented to obtain ultra-high-resolution spectra at a localized point in space. The spectral data is then fit to the Schrödinger equation for determination of the magnetic-field vector. To obtain the magnetic-field topology, the measurement spatial location is scanned over the desired region of space by steering the DFSS pump laser beam. The goal of this project is to assemble and commission a portable DFSS diagnostic capable of 2-D magnetic-field vector measurements utilizing the Hα spectral line profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photon Doppler Velocimetry to Spatially Resolve Plasma Density in a Power Flow Gap

The understanding of power flow plasmas is important as we look towards next generation pulsed power (NGPP) as current losses could prohibit the goals of that facility. Therefore, it is important to have accurate diagnostics of the plasma parameters on the current machines, which can be used to help inform and improve simulations. Having these plasma parameters will help validate models and simulations to provide confidence when they are expanded to conditions relevant to NGPP. One important plasma parameter that can be measured is the electron density, which can be measured by photonic Doppler velocimetry (PDV). A PDV system has several key advantages over other interferometers by measuring relatively low densities (> 1 × 10 15 cm -2 ) with both spatial and temporal resolution. Experiments were performed on the Mykonos pulsed power machine, which is a 1 MA sub scale machine in which recent platforms have been developed to explore current densities relevant to the inner magnetically insulated transmission line (MITL) on the Z machine. Experiments were performed on two different platforms, the thin foil platform and the Mykonos parallel plate platform (MP3). In addition, a combination of both single-point and multi-point measurements were used. The single-point measurements proved to be very promising, providing a clear increase in density at about 70 ns into the current rise on thin foil experiments up to about 5 × 10 17 cm -3 before the probe stopped providing signal. While we did also see returns from multi-point measurements on both platforms, the signals were not as easy to interpret due to strong background effects. However, they do show initial promise for this diagnostic to measure density at several points across a 1 mm gap. These measurements provide insights in how to improve the diagnostic so that it can provide useful information on power flow relevant experiments.

47 OTHER INSTRUMENTATION↗

A Study of Pulse-Doppler Radar Pulse Repetition Frequency

Measurements of both long ranges and high velocities pose a contradiction to a pulse-Doppler radar, driving the desired Pulse Repetition Frequency (PRF) in different directions. Often, making one of the measurements unambiguous will make the other ambiguous. The PRF can be adjusted to trade ambiguities in range and velocity, subject to well-defined limits. Various regions of the radar’s operating characteristics in range-velocity space have come to be termed Low-PRF, Medium-PRF, and High-PRF. Selecting a radar operating point, chiefly its PRF, will not only characterize ambiguities that are generated, but also blind ranges and blind velocities. Techniques to mitigate ambiguities and blind regions do exist, allowing substantial extension of the discernable ranges and velocities to the radar.

47 OTHER INSTRUMENTATION↗