Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed power generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Hong-Ou-Mandel interference with a coexisting clock using transceivers for synchronization over deployed fiber

Interference between independently generated photons is a key step towards distributing entanglement over long distances, but it requires synchronization between the distantly-located photon sources. Synchronizing the clocks of such photon sources using coexisting two-way classical optical communications over the same fiber that transports the quantum photonic signals is a promising approach for achieving photon-photon interference over long distances, enabling entanglement distribution for quantum networking using the deployed fiber infrastructure. Here, we demonstrate photon-photon interference by observing the Hong-Ou-Mandel dip between two distantly-located sources: a weak coherent-state source obtained by attenuating the output of a laser and a heralded single-photon source. We achieve a maximum dip visibility of 0.58 +/- 0.04 when the two sources are connected via 4.3 km of deployed fiber. Dip visibilities > 0.5 are nonclassical and a first step towards achieving teleportation over the deployed fiber infrastructure. In our experiment, the classical optical communication is achieved with - 21 dBm of optical signal launch power, which is used to synchronize the clocks in the two independent, distantly-located photon sources. The impact of spontaneous Raman scattering from the classical optical signals is mitigated by appropriate choice of the quantum- and classical-channel wavelengths. All equipment used in our experiment (the photon sources and the synchronization setup) is commercially available. Finally, our experiment represents a scalable approach to enabling practical quantum networking with commercial equipment and coexistence with classical communications in optical fiber.

47 OTHER INSTRUMENTATION↗

EmSense: A High-Resolution Emulated Sensor for Experiments with the Smart Grid and Distributed Ledger Technology

This work involves the development of a device - EmSense (“Emulated Sensor”) - that emulates a high-resolution sensor for a power grid. The device collects raw current and voltage sensor data which derive from ORNL's signature library. This library is a dataset that ORNL curates from many different sources that include power systems from various utilities. The EmSense packages the data from the library in the form of IEC 61850 Sampled Value (SV) packets and then broadcasts these SV packets on the network. In another mode, EmSense can generate artificial sinusoidal data that appears as waveforms for voltage and current signals. EmSense has an internal algorithm for determining the period of a signal based on the data so that the period can be specified as a variable in the IEC 61850 packets. The purpose of EmSense is to allow for experimentation with the Dark Net Infrastructure where a variety of power line sensors must be represented along with their typical communication traffic. The EmSense device was developed in coordination with the software for receiving and processing the packets in the Distributed Ledger Technology (DLT) framework of the DarkNet Project. This receiving software must have a methodology for dealing with information of high velocity, variety, and volume. Experimenting with EmSense facilitates the development of such software. The results showed that the DLT framework and the trust-anchoring approach managed to process a large flow of traffic even with up to six instances of EmSense device broadcasting data. This was achieved without overfilling packet queues in the memory of the actual hardware of the DLT devices or causing the Central Processing Unit (CPU) of the hardware to be overwhelmed. The DLTs were also able to store the data in a compact and useful form for later analysis and archival purposes.

Werth, Aaron↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Physics-Informed Graph Neural Networks for Collaborative Dynamic Reconfiguration and Voltage Regulation in Unbalanced Distribution Systems

Network reconfiguration has long been employed as a strategic approach to minimize power distribution system losses and effectively regulate voltage levels. Tap-changing voltage regulators are also critical for controlling bus voltages, especially in accommodating the increasing integration of distributed energy resources (DERs) with intermittent outputs. This paper introduces novel methodologies to address the challenges of dynamic reconfiguration and optimal tap setting in unbalanced three-phase distribution systems. We propose an approximated mixed-integer quadratically constrained program (MIQCP) to model dynamic reconfiguration, along with a pioneering formulation for voltage regulator (VR) tap-setting based on Special Ordered Set type 1 (SOS1). To mitigate computational complexity, we propose a physics-informed spatial-temporal graph convolutional network (STGCN) with an integrated link classifier. The proposed approach enables efficient solution generation by fixing specific variables in the MIQCP instance and solving the simplified sub-MIP using an MIP solver. Numerical studies demonstrate the superior prediction accuracy of our STGCN model compared to baseline neural network models, resulting in reduced DER curtailment and voltage deviation with shorter computation time.

dynamic reconfiguration↗

Towards Non-Intrusive Real-Time Monitoring of Behind the Meter Residential Distributed Energy Resources

The growing adoption of residential distributed energy resources (DERs) introduces more uncertain variability in power grid operation. More importantly, the residential DERs operate behind customers’ energy meters, and therefore, the utility cannot “directly” monitor them. Prior approaches to enable visibility into behind-the-meter (BTM) DERs either depend on estimations or require intrusive instrumentation on the customer side. To address the critical need for direct real-time monitoring of BTM DERs, in this paper, we propose a novel approach for utility-side direct real-time monitoring of residential BTM DERs. We utilize high-frequency (> 10kHz) conducted electromagnetic interference (EMI) from residential DERs’ grid-tied inverters to monitor their power generation. We discuss the working principle of our approach and present supporting results using three of-the-shelf grid-tied inverters.

14 SOLAR ENERGY↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

DINGO: Digital assistant to grid operators for resilience management of power distribution system

With increasing adverse weather events and disasters, enabling resiliency of the power distribution system (PDS) is becoming increasingly important. Here in this work, resiliency is defined as the systems ability to keep supplying critical loads even with multiple contingencies. Resiliency may depend on: (a) advanced tools to assist operators in situational awareness and decision making with the increasing volume of data generated by the PDS, (b) visualization and ease of interaction with system resources and information, especially during extreme events and resulting human operator stress, and (c) flexible resources and autonomous control. Operators and support engineers need to interact with the system for key information and take action under stress, given the requirement for decisions in a short time. Integrated technological solutions are prevailing steps to support the most appropriate decision during critical times to serve essential loads. In order to meet the required goals, a Real-time Resiliency Monitoring and Operational Decision Support (RT-RMOD) tool have been developed. It supports various functionalities, including real-time monitoring, resilience assessment, and proactive decision support. However, this work makes advanced feature additions to the tool by developing data-enabled resilience management algorithms for (i) outage detection and localization, (ii) Resiliency-metric driven restoration and reconfiguration, and (iii) NLP based digital assistant for operators called DINGO (DIgital assistaNt to Grid Operators) to interact with Advanced Distribution Management System (ADMS) and RT-RMOD. The developed algorithm was validated for multiple cases of weather events using a real-world, off-grid microgrid system modeled in a real-time simulator, sensor data, and software tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient and mechanically-robust organic solar cells based on vertical stratification modulation through sequential blade-coating

Mechanically durable organic solar cells (OSCs) with high efficiency are deemed as the ideal candidate for the power source of the next generation wearable electronic devices. However, the brittle nature of small molecules in most high-efficiency OSCs consisting of polymer and small molecule encourages easy formation of cracks in the photoactive film under deformation. Here, the vertical composition distribution of the active layer has been well optimized through sequential blade coating to realize highly deformable while efficient OSC. The optimized morphology exhibits distinct donor-rich and homogenous region distributed along the vertical direction in the bulk. The donor-rich region provides sufficient chain entanglements and strong interfaces beneficial for mechanical robustness of film, while homogeneously mixed region offers continuous interpenetrating network to maintain high device through-put, resulting in superior efficiency of 14.4% with high crack-onset strain (COS) of 30.5%. This efficiency versus COS combination is much higher than the best combination reported in all polymer systems (COS of 15.9% and efficiency of 11.1%). To the best of our knowledge, it is the highest COS value achieved in polymer-small molecule systems. As a result, the rational control over vertical stratification demonstrated here would guide researchers in the development of innovative wearable electronics.

36 MATERIALS SCIENCE↗

Resilience-Motivated Distribution System Restoration Considering Electricity-Water-Gas Interdependency

A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is maximizing the supply of electricity, water, and gas to critical customers after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. Additionally, the characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to non convex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on an electricity-water-gas integrated system, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Coastal Community Resiliency Enhancement Using Marine Hydrokinetic (MHK) Resources and Networked Microgrids

Enormous challenges are inherent in the operation of modern distribution grids. In particular, distribution feeders can be severely compromised under extreme conditions such as large-scale weather events (e.g., hurricanes, floods, and other types of natural disasters). To combat this problem, they turn to local energy support from distributed energy resources, such as solar and wind, marine hydrolinetic (MHK), and other types of energy. In this report, we investigate the actual characteristics of MHK resources to enhance coastal community resiliency. Two typical types of MHK resources (i.e., wave and tidal resources) illustrate the coastal resilience enhancement framework. By identifying their operational characteristics, such as target time-scales and potential power generation variations, we detail a holistic coastal community resiliency enhancement framework that integrates both optimization and control efforts. The optimization problem is formulated to significantly minimize the power outage time at the critical infrastructures in coastal communities by implementing multiple autonomous and dynamic microgrids around MHK resources. Therefore, during severe power outages caused by natural disasters (e.g., floods, hurricanes), the coastal community load profiles can be satisfied using local MHK resources in each microgrid with limited or no power support from upstream power grids.

16 TIDAL AND WAVE POWER↗

Energy storage emerging: A perspective from the Joint Center for Energy Storage Research

Energy storage is an integral part of modern society. A contemporary example is the lithium (Li)-ion battery, which enabled the launch of the personal electronics revolution in 1991 and the first commercial electric vehicles in 2010. Most recently, Li-ion batteries have expanded into the electricity grid to firm variable renewable generation, increasing the efficiency and effectiveness of transmission and distribution. Important applications continue to emerge including decarbonization of heavy-duty vehicles, rail, maritime shipping, and aviation and the growth of renewable electricity and storage on the grid. This perspective compares energy storage needs and priorities in 2010 with those now and those emerging over the next few decades. The diversity of demands for energy storage requires a diversity of purpose-built batteries designed to meet disparate applications. Advances in the frontier of battery research to achieve transformative performance spanning energy and power density, capacity, charge/discharge times, cost, lifetime, and safety are highlighted, along with strategic research refinements made by the Joint Center for Energy Storage Research (JCESR) and the broader community to accommodate the changing storage needs and priorities. Innovative experimental tools with higher spatial and temporal resolution, in situ and operando characterization, first-principles simulation, high throughput computation, machine learning, and artificial intelligence work collectively to reveal the origins of the electrochemical phenomena that enable new means of energy storage. This knowledge allows a constructionist approach to materials, chemistries, and architectures, where each atom or molecule plays a prescribed role in realizing batteries with unique performance profiles suitable for emergent demands.

Trahey, Lynn↗

Learning-Accelerated ADMM for Distributed DC Optimal Power Flow

We propose a novel data-driven method to accelerate the convergence of Alternating Direction Method of Multipliers (ADMM) for solving distributed DC optimal power flow (DC-OPF) where lines are shared between independent network partitions. Using previous observations of ADMM trajectories for a given system under varying load, the method trains a recurrent neural network (RNN) to predict the converged values of dual and consensus variables. Given a new realization of system load, a small number of initial ADMM iterations is taken as input to infer the converged values and directly inject them into the iteration. We empirically demonstrate that the online injection of these values into the ADMM iteration accelerates convergence by a significant factor for partitioned 14-, 118- and 2848-bus test systems under differing load scenarios. The proposed method has several advantages: it maintains the security of private decision variables inherent in consensus ADMM; inference is fast and so may be used in online settings; RNN-generated predictions can dramatically improve time to convergence but, by construction, can never result in infeasible ADMM subproblems; it can be easily integrated into existing software implementations. While we focus on the ADMM formulation of distributed DC-OPF in this paper, the ideas presented are naturally extended to other distributed optimization problems.

alternating direction method of multipliers↗

Optimal Portfolio Design of Distributed Energy Resources on Puerto Rico Distribution Feeders with Long Outages after Hurricane Maria

This work details a project to design reliable, resilient, and cost-effective networked microgrids considering grid constraints and resilience metrics focused on Puerto Rico distribution feeder locations with long outages after Hurricane Maria. The project consisted primarily of modeling and simulation tasks that accomplished the following objectives: 1. Selected 10 distribution feeder models in vulnerable areas. The sample feeders are geographically distributed across Puerto Rico and vary in length to capture the wide variety of feeders on the island. 2. Determined the optimal location and sizing of distributed energy resources (DERs) on the identified distribution feeders. The systems considered as part of the microgrid solutions were solar photovoltaic (PV), battery energy storage systems (BESS) and distributed fossil fuel generation (DFFG). 3. Estimated the cost-benefit of the proposed DER portfolios. 4. Provided a set of final recommendations that inform decision making on how to do targeted planning analysis for microgrids that can supply energy to critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Environmental Co‐Benefits of Maintaining Native Vegetation With Solar Photovoltaic Infrastructure

Abstract Co‐locating solar photovoltaics with vegetation could provide a sustainable solution to meeting growing food and energy demands. However, studies quantifying multiple co‐benefits resulting from maintaining vegetation at utility‐scale solar power plants are limited. We monitored the microclimate, soil moisture, panel temperature, electricity generation and soil properties at a utility‐scale solar facility in a continental climate with different site management practices. The compounding effect of photovoltaic arrays and vegetation may homogenize soil moisture distribution and provide greater soil temperature buffer against extreme temperatures. The vegetated solar areas had significantly higher soil moisture, carbon, and other nutrients compared to bare solar areas. Agrivoltaics in agricultural areas with carbon debt can be an effective climate mitigation strategy along with revitalizing agricultural soils, generating income streams from fallow land, and providing pollinator habitats. However, the benefits of vegetation cooling effects on electricity generation are rather site‐specific and depend on the background climate and soil properties. Overall, our findings provide foundational data for site preservation along with targeting site‐specific co‐benefits, and for developing climate resilient and resource conserving agrivoltaic systems.

14 SOLAR ENERGY↗