Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Direction-dependent localization errors in SPECT images

Purpose: Single photon emission computed tomography (SPECT) is being investigated for imaging inside radiation therapy treatment rooms to localize biological targets. Here, computer simulations were used to analyze locational and directional dependencies in localization errors and to assess the effects of spatial resolution modeling and observer normalization on localization performance. Methods: SPECT images of the XCAT phantom, containing 12 hot tumors, were reconstructed with detector response function compensation (DRC) and without DRC (nDRC). Numerical observers were forced to select the most suspicious tumor location, using normalized cross correlation (NXC) or un-normalized cross correlation (XC), from 3 cm diameter search volumes that each contained only one tumor. For each tumor site, localization was optimized as a function of the iteration number and postreconstruction smoothing. Localization error, the distance between true and estimated tumor positions, was calculated across the ensembles of 80 images. Direction-dependent localization bias and precision were estimated from the image ensemble. Results: For the six superficial tumors in close proximity to the detector trajectory, mean localization errors were <2 mm and were lowest or comparable using DRC-NXC, though differences from DRC-XC and nDRC-NXC were not statistically significant. DRC-NXC did provide statistically significantly better localization than nDRC-XC for five of these six tumors. At the other six sites where attenuation was more severe and the distance was generally greater between the tumor and detector, DRC typically did not show better localization than nDRC. Observer normalization improved the localization substantially for a tumor near the hotter heart. Localization errors were anisotropic and dependent on tumor location relative to the detector trajectory. Conclusions: This computer-simulation study compared localization performance for normalized and un-normalized numerical observers, which were used to estimate tumor positions in SPECT images, reconstructed with and without DRC. For tumors localized to <2 mm on average, which are good candidates for SPECT-guided radiation therapy, localization performance typically improved by compensating for the detector response function and by using a normalized observer. The observed direction-dependent localization errors have important implications for radiation therapy and are relevant to SPECT imaging in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation study of fast ion losses associated with the rotating n = 1 resonant magnetic perturbations in KSTAR

In this work we describe a simulation framework for testing the fast ion loss mechanism associated with the experimentally observed beam ion losses when an externally applied toroidally rotating perturbed magnetic field is used to control edge localized modes in the KSTAR tokamak. The simulations reproduce the key qualitative features of neutral beam injection (NBI) ion detection by a fast ion loss detector. The NBI ion losses in the simulation mainly occur for passing particles due to orbit stochastization, which is caused by orbit resonance with the 3D field perturbations. The relative toroidal angle of NBI ion deposition to the orbit island determines the radial path of the particles between confinement or loss. The fast ion loss quantity depends on the toroidal angle rotation of the 3D field with respect to the beam deposition position. The averaged transport of toroidal canonical angular momentum reveals that linear and nonlinear resonance of the NBI ions within the 3D field are the main factors determining fast ion transport and loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of a geometric deep learning pipeline for HL-LHC particle tracking

The Exa.TrkX project has applied geometric learning concepts such as metric learning and graph neural networks to HEP particle tracking. Exa.TrkX’s tracking pipeline groups detector measurements to form track candidates and filters them. The pipeline, originally developed using the TrackML dataset (a simulation of an LHC-inspired tracking detector), has been demonstrated on other detectors, including DUNE Liquid Argon TPC and CMS High-Granularity Calorimeter. This paper documents new developments needed to study the physics and computing performance of the Exa.TrkX pipeline on the full TrackML dataset, a first step towards validating the pipeline using ATLAS and CMS data. The pipeline achieves tracking efficiency and purity similar to production tracking algorithms. Crucially for future HEP applications, the pipeline benefits significantly from GPU acceleration, and its computational requirements scale close to linearly with the number of particles in the event.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of Phonon Physics in the CDMS Detector Monte Carlo

The SuperCDMS collaboration is a dark matter search effort aimed at detecting the scattering of WIMP dark matter from nuclei in cryogenic germanium targets. The CDMS Detector Monte Carlo (CDMS-DMC) is a simulation tool aimed at achieving a deeper understanding of the performance of the SuperCDMS detectors and aiding the dark matter search analysis. We present results from validation of the phonon physics described in the CDMS-DMC and outline work towards utilizing it in future WIMP search analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Sensitivity Analysis of Neutron Multiplicity Counting Statistics Using First-Order Perturbation Theory and Application to a Subcritical Plutonium Metal Benchmark

It is frequently important to estimate the uncertainty and sensitivity of measured and computed detector responses in subcritical experiments and simulations. These uncertainties arise from the physical construction of the experiment, uncertainties in the transport parameters, and counting uncertainties. Perturbation theory enables sensitivity analysis (SA) and uncertainty quantification on integral quantities like detector responses. Here the aim of our work is to apply SA to the statistics of subcritical neutron multiplicity counting distributions. Current SA methods have only been applied to mean detector responses and the keff eigenvalue. For multiplicity counting experiments, knowledge of the higher-order counting moments and their uncertainties are essential for a complete SA. We apply perturbation theory to compute the sensitivity of neutron multiplicity counting moments to arbitrarily high order. Each moment is determined by solving an adjoint transport equation with a source term that is a function of the adjoint solutions for lower-order moments. This enables moments of arbitrarily high order to be sequentially determined, and it shows that each moment is sensitive to the uncertainties of all lower-order moments. To close our SA of the moments, we derive forward transport equations that are functions of the forward flux and lower-order moment adjoint fluxes. We verify our calculations for the first three moments by comparison with multiplicity counting measurements of a subcritical plutonium metal sphere. For the first three moments, the most influential parameters are ranked, and the validity of first-order perturbation theory is demonstrated by examining the series truncation error. This enables a detailed SA of subcritical multiplicity counting measurements of fissionable material based on transport theory.

42 ENGINEERING↗

P-Type Silicon Strip Sensors for the new CMS Tracker at HL-LHC

The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs for the future outer tracker at the CMS experiment. Based on these results, the collaboration has chosen to use n-in-p type silicon sensors and focus further investigations on the optimization of that sensor type. This paper describes the main measurement results and conclusions that motivated this decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid argon TPC signal formation, signal processing and reconstruction techniques

This document describes a reconstruction chain that was developed for the ArgoNeuT and MicroBooNE experiments at Fermilab. These experiments study accelerator neutrino interactions that occur in a Liquid Argon Time Projection Chamber. Reconstructing the properties of particles produced in these interactions benefits from the knowledge of the micro-physics processes that affect the creation and transport of ionization electrons to the readout system. A wire signal deconvolution technique was developed to convert wire signals to a standard form for hit reconstruction, to remove artifacts in the electronics chain and to remove coherent noise. A unique clustering algorithm reconstructs line-like trajectories and vertices in two dimensions which are then matched to create of 3D objects. In conclusion, these techniques and algorithms are available to all experiments that use the LArSoft suite of software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cavallo's multiplier for in situ generation of high voltage

Here, a classic electrostatic induction machine, Cavallo's multiplier, is suggested for in situ production of very high voltage in cryogenic environments. The device is suitable for generating a large electrostatic field under conditions of very small load current. Operation of the Cavallo multiplier is analyzed, with quantitative description in terms of mutual capacitances between electrodes in the system. A demonstration apparatus was constructed, and measured voltages are compared to predictions based on measured capacitances in the system. The simplicity of the Cavallo multiplier makes it amenable to electrostatic analysis using finite element software, and electrode shapes can be optimized to take advantage of a high dielectric strength medium such as liquid helium. A design study is presented for a Cavallo multiplier in a large-scale, cryogenic experiment to measure the neutron electric dipole moment.

47 OTHER INSTRUMENTATION↗

Optimization of in-line phase contrast particle image velocimetry using a laboratory x-ray source

Phase contrast particle image velocimetry (PIV) using a laboratory x-ray microfocus source is investigated using a numerical model. Phase contrast images of 75 {mu}m air bubbles, embedded within water exhibiting steady-state vortical flow, are generated under the paraxial approximation using a tungsten x-ray spectrum at 30 kVp. Propagation-based x-ray phase-contrast speckle images at a range of source-object and object-detector distances are generated, and used as input into a simulated PIV measurement. The effects of source-size-induced penumbral blurring, together with the finite dynamic range of the detector, are accounted for in the simulation. The PIV measurement procedure involves using the cross-correlation between temporally sequential speckle images to estimate the transverse displacement field for the fluid. The global error in the PIV reconstruction, for the set of simulations that was performed, suggests that geometric magnification is the key parameter for designing a laboratory-based x-ray phase-contrast PIV system. For the modeled system, x-ray phase-contrast PIV data measurement can be optimized to obtain low error (<0.2 effective pixel of the detector) in the system with magnification lying in the range between 1.5 and 3. For large effective pixel size (>15 {mu}m) of the detector, high geometric magnification (>2.5) is desired, while for large source size system (FWHM > 30 {mu}m), low magnification (<1.5) would be suggested instead. The methods developed in this paper can be applied to optimizing phase-contrast velocimetry using a variety of laboratory x-ray sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization Simulations for a Gamma-Ray Calibration Standard for a Cyclic Neutron Activation Analysis Pneumatic System at the Penn State Breazeale Reactor

For new experimental setups, the initial testing and calibrations can be expensive and time consuming without prior optimization. However, these issues can be mitigated using realistic modeling and simulation studies of the proposed system a priori. Specifically, an experiment can be performed virtually using realistic simulations and the expected results evaluated to inform adjustments of the experimental setup to achieve optimum results. At the Penn State Breazeale Reactor, a new pneumatic transfer system has been developed for the detection and characterization of short-lived fission fragments to enhance and complement existing nuclear data. The system accomplishes this task by transporting samples cyclically between an assortment of gamma-ray/neutron detectors and the reactor-core vicinity with sub-second transit times. The measured neutron flux paired with simulations of detector response using Geant4 and a custom module for estimating cascade summing effects and corrections were used to select sample-material masses for system characterization. With the optimized sample masses, an experimental counting plan for characterizing the repeatability of the newly developed pneumatic system was developed. Finally, the predictions made with these simulations allowed for optimization of the irradiation sample characteristics and gamma-ray detection system.

cyclic neutron activation, gamma-ray spectroscopy↗

Simulating NMIS Imaging and Fission-Mapping Measurements

The Nuclear Materials Identification System (NMIS) detects and characterizes fissile and nonfissile materials using time correlations between a time-tagged source and one or more detectors. The first fieldable configuration of dedicated hardware and software was developed in the 1990s. In its original configuration, the measurement system consisted of a time-tagged source and two to four detectors. Measurements with this configuration were easily simulated using a single Monte Carlo run. The present measurement configuration is far more complex than the original. The source is now divided into multiple neutron cones; significantly more detectors are included; and the source, detectors, and object being interrogated can all be moved during the measurement to capture different views of the object. In addition to the hardware changes, the software can now reconstruct high-resolution tomographs of the 14 MeV neutron attenuation coefficients and fission sites inside the object. This work shows how a complex measurement of an object that consists of both fissile and nonfissile parts can be simulated by using multiple input decks and combining the resulting output into the desired format. The results of this simulation were then reconstructed using the imaging and fission-mapping software used with measurements. These reconstructions are consistent with the original model, thus validating the simulation method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of the Liquid Argon Scattering Experimental Discrepancies Using Simulation

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Proton Assembly Building at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS’s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced photo multiplier. With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.; Fermilab]↗

WE-G-204-05: Relative Object Detectability Evaluation of a New High Resolution A-Se Direct Detection System Compared to Indirect Micro-Angiographic Fluoroscopic (MAF) Detectors

Purpose: To evaluate the task specific imaging performance of a new 25µm pixel pitch, 1000µm thick amorphous selenium direct detection system with CMOS readout for typical angiographic exposure parameters using the relative object detectability (ROD) metric. Methods: The ROD metric uses a simulated object function weighted at each spatial frequency by the detectors’ detective quantum efficiency (DQE), which is an intrinsic performance metric. For this study, the simulated objects were aluminum spheres of varying diameter (0.05–0.6mm). The weighted object function is then integrated over the full range of detectable frequencies inherent to each detector, and a ratio is taken of the resulting value for two detectors. The DQE for the 25µm detector was obtained from a simulation of a proposed a-Se detector using an exposure of 200µR for a 50keV x-ray beam. This a-Se detector was compared to two microangiographic fluoroscope (MAF) detectors [the MAF-CCD with pixel size of 35µm and Nyquist frequency of 14.2 cycles/mm and the MAF-CMOS with pixel size of 75µm and Nyquist frequency of 6.6 cycles/mm] and a standard flat-panel detector (FPD with pixel size of 194µm and Nyquist frequency of 2.5cycles/mm). Results: ROD calculations indicated vastly superior performance by the a-Se detector in imaging small aluminum spheres. For the 50µm diameter sphere, the ROD values for the a-Se detector compared to the MAF-CCD, the MAF-CMOS, and the FPD were 7.3, 9.3 and 58, respectively. Detector performance in the low frequency regime was dictated by each detector’s DQE(0) value. Conclusion: The a-Se with CMOS readout is unique and appears to have distinctive advantages of incomparable high resolution, low noise, no readout lag, and expandable design. The a-Se direct detection system will be a powerful imaging tool in angiography, with potential break-through applications in diagnosis and treatment of neuro-vascular disease. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Muon Neutrino Charged Current Events in an Off-Axis Horn-Focused Neutrino Beam Using the NOvA Prototype Detector

The NOνA is a long base-line neutrino oscillation experiment. It will study the oscillations between muon and electron neutrinos through the Earth. NOνA consists of two detectors separated by 810 km. Each detector will measure the electron neutrino content of the neutrino (NuMI) beam. Differences between the measurements will reveal details about the oscillation channel. The NOνA collaboration built a prototype detector on the surface at Fermilab in order to develop calibration, simulation, and reconstruction tools, using real data. This 220 ton detector is 110 mrad off the NuMI beam axis. This off-axis location allows the observation of neutrino interactions with energies around 2 GeV, where neutrinos come predominantly from charged kaon decays. During the period between October 2011 and April 2012, the prototype detector collected neutrino data from 1.67 × 10 20 protons on target delivered by the NuMI beam. This analysis selected a number of candidate charged current muon neutrino events from the prototype data, which is 30% lower than predicted by the NOνA Monte Carlo simulation. The analysis suggests that the discrepancy comes from an over estimation of the neutrino flux in the Monte Carlo simulation, and in particular, from neutrinos generated in charged kaon decays. The ratio of measured divided by the simulated flux of muon neutrinos coming from charged kaon decays is: 0.70 +0.108 -0.094 . The NOνA collaboration may use the findings of this analysis to introduce a more accurate prediction of the neutrino flux produced by the NuMI beam in future Monte Carlo simulations.

43 PARTICLE ACCELERATORS↗

Dark matter directional detection: comparison of the track direction determination

Several directional techniques have been proposed for a directional detection of Dark matter, among others anisotropic crystal detectors, nuclear emulsion plates, and low-pressure gaseous TPCs. The key point is to get access to the initial direction of the nucleus recoiling due to the elastic scattering by a WIMP. In this article, we aim at estimating, for each method, how the information of the recoil track initial direction is preserved in different detector materials. We use the SRIM simulation code to emulate the motion of the first recoiling nucleus in each material. We propose the use of a new observable, D , to quantify the preservation of the initial direction of the recoiling nucleus in the detector. We show that in an emulsion mix and an anisotropic crystal, the initial direction is lost very early, while in a typical TPC gas mix, the direction is well preserved.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of nuclear effects in neutrino-argon interactions using generalized kinematic imbalance variables with the MicroBooNE detector

We present a set of new generalized kinematic imbalance variables that can be measured in neutrino scattering. These variables extend previous measurements of kinematic imbalance on the transverse plane and are more sensitive to modeling of nuclear effects. We demonstrate the enhanced power of these variables using simulation and then use the MicroBooNE detector to measure them for the first time. We report flux-integrated single- and double-differential measurements of charged-current muon neutrino scattering on argon using a topology with one muon and one proton in the final state as a function of these novel kinematic imbalance variables. These measurements allow us to demonstrate that the treatment of charged current quasielastic interactions in genie version 2 is inadequate to describe data. As a result, they reveal tensions with more modern generator predictions particularly in regions of phase space where final state interactions are important.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integration of a Fire Detector into a Spacecraft

A detector sensitive to only the ultraviolet radiation emitted by flames has been selected as the basic element of the NASA Skylab fire detection system. It is sensitive to approximately 10(exp -12)W of radiation and will detect small flames at distances in excess of 3m. The performance of the detector was verified by experiments in an aircraft flying zero-gravity parabolas to simulate the characteristics of a fire which the detector must sense. Extensive investigation and exacting design was necessary to exclude all possible sources of false alarms. Optical measurements were made on all the spacecraft windows to determine the amount of solar radiation transmitted. The lighting systems and the onboard experiments also were appraised for ultraviolet emissions. Proton-accelerator tests were performed to determine the interaction of the Earth's trapped radiation belts with the detectors and the design of the instrument was modified to negate these effects.

Linford, R. M. F.↗