Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

DimaSense™: A Novel Nucleic Acid Detection System

Recently, we developed a suite of methods for the rational design and fabrication of well-defined nanoparticle architectures, including clusters using bio-encoded nanoscale building blocks and layer-by-layer stepwise assembly on a solid support. In particular, the Nano-Assembly platform using Encoded Solid Supports (NAESS) allows for controlled interactions, purification of side products, modularity of design, and the construction of complex nanoparticle architectures. This approach offers several advantages over the current art of designing nanoparticle clusters, which include the high-yield synthesis of desired architectures, a 'plug-and-play' design allowing for the introduction of a variety of sensing modalities, and ease of scalability in high-throughput and synthesis yield. As a utility proof of concept, we implemented our unique cluster fabrication platform to design gold nanoparticle dimers which are linked via a single-stranded DNA oligonucleotide recognition motif. The design of this motif is such that binding of complementary nucleic acids results in specific, selective and rapid dimer dissociation, which can be monitored by dynamic light scattering (DLS). We demonstrated single level mismatch selectivity using this approach. The limit of detection was determined to be 1011 molecules of synthetic target RNA or DNA within 30 minutes of incubation at 33 C. This detection limit is determined by the dimer's concentration which can be probed by currently used standard DLS instruments. We also demonstrated a specific detection of target RNA in a solution containing competing 1,000-fold excess of non-complementary DNA fragments, 10% BSA, and endonucleases. Molecular diagnostic companies, RNA-based technology developers, and personalized medicine companies have applications that could benefit from using DimaSense{trademark}. The technology represents a platform which enables the simple and reasonably inexpensive design and fabrication of highly selective genetic sensors. These sensors operate with very low concentrations of target, can utilize standard instrumentation, produce detection results rapidly, and are robust enough to function in the presence of many competing genetic targets. Many current genetic target detection products/approaches/technologies rely upon methods (such as qPCR) which are more complicated, cumbersome, and costly to perform, and are not well suited to point-of-care diagnostic applications. Several clinical diagnostic applications, particularly point-of-care (POC) diagnostics for infectious diseases, are possible and appear to be a good fit for the technology. In addition, the advent of personalized medicine will create opportunities for molecular diagnostic companies with the capabilities of rapidly and quantitatively detecting nucleic acid sequences. The global POC market was {approx}$7.7B in 2010, with a recent annual growth rate of {approx}7%. A specific disease or disease-class diagnostic would need to be identified before a more meaningful sub-market value could be stated. Additional validation of the technology to show that it displays appropriate performance parameters for a commercial application on 'real world' samples is required for true commercial readiness. In addition, optimization of sensor design parameters, to effect a 10-fold increase in sensitivity, may be required to produce a commercially ready sensor system. These validation and sensor design optimization are estimated to require 3-4 months and {approx}$75k. For an unregulated product to give this sensor system a distinct competitive advantage, 2-3 years of product development and $1.5-3M are likely required. For regulated markets, time to market (through clinic) and cost would depend upon the product.

59 BASIC BIOLOGICAL SCIENCES↗

Revolution in Detection Affairs

The detection of nuclear or radioactive materials for homeland or national security purposes is inherently difficult. This is one reason detection efforts must be seen as just one part of an overall nuclear defense strategy which includes, inter alia, material security, detection, interdiction, consequence management and recovery. Nevertheless, one could argue that there has been a revolution in detection affairs in the past several decades as the innovative application of new technology has changed the character and conduct of detection operations. This revolution will likely be most effectively reinforced in the coming decades with the networking of detectors and innovative application of anomaly detection algorithms.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Primary Water Stress Corrosion Cracks in Nickel Alloy Dissimilar Metal Welds: Detection and Sizing Using Established and Emerging Nondestructive Examination Techniques

The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) as a follow-on to the international cooperative Program for the Inspection of Nickel Alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive evaluation (NDE) techniques to detect and characterize surface-breaking primary water stress corrosion cracks in dissimilar-metal welds (DMW) in bottom-mounted instrumentation (BMI) penetrations and small-bore (≈400-mm diameter) piping components. A series of international blind round-robin tests were conducted by commercial and university inspection teams. Results from these tests showed that a combination of conventional and phased-array ultrasound techniques provided the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in BMIs by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field. The goal of PARENT is to continue the work begun in PINC and apply the lessons learned to a series of open and blind international round-robin tests that will be conducted on a new set of piping components including large-bore (≈900-mm diameter) DMWs, small-bore DMWs, and BMIs. Open round-robin testing will engage universities and industry worldwide to investigate the reliability of emerging NDE techniques to detect and accurately size flaws having a wide range of lengths, depths, orientations, and locations. Blind round-robin testing will invite testing organizations worldwide, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from easy to very difficult to detect and size. This paper presents highlights of PINC and reports on the plans and progress for PARENT round-robin tests.

cracks↗

Localization-Based detection under network losses

We consider a networked system of sensors that measure the intensity of a source amidst background inside a two-dimensional monitoring area. The source intensity decays away from it, and the corresponding sensor measurements are random with a parameter determined by the intensity at sensor location. The detection problem is to infer the presence of a source based on measurements. Under a statistical independence condition, we show that a detection method based on maximum likelihood fuser performs below the individual sensors in presence of network losses. It has been previously shown that the localization of a source using measurements from multiple sensors leads to an improved detection, thereby establishing the effectiveness of a network over single or co-located sensors. We show that the communication losses degrade such network detection performance, particularly to levels below that of a single sensor under heavy losses. Under fairly general conditions on the source intensity decay functions and underlying measurement distributions, we quantify the loss of performance of the localization-based detection as a function of loss rate and packing number of state space. We present simulation and experimental results that illustrate the performance degradations due to network losses in detecting radiation sources.

cyber-physical networks↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy’s National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI’s Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: 1. Run in real-time on the edge (≥ 12 Hz) 2. Classification: Achieve less than 5% false positive detection 3. Classification: Achieve ≥ 95% methane plume detection rate 4. Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Radiation and Electromagnetic Induction Data Fusion for Detection of Buried Radioactive Metal Waste - 12282

At the United States Army's test sites, fired penetrators made of Depleted Uranium (DU) have been buried under ground and become hazardous waste. Previously, we developed techniques for detecting buried radioactive targets. We also developed approaches for locating buried paramagnetic metal objects by utilizing the electromagnetic induction (EMI) sensor data. In this paper, we apply data fusion techniques to combine results from both the radiation detection and the EMI detection, so that we can further distinguish among DU penetrators, DU oxide, and non- DU metal debris. We develop a two-step fusion approach for the task, and test it with survey data collected on simulation targets. In this work, we explored radiation and EMI data fusion for detecting DU, oxides, and non-DU metals. We developed a two-step fusion approach based on majority voting and a set of decision rules. With this approach, we fuse results from radiation detection based on the RX algorithm and EMI detection based on a 3-step analysis. Our fusion approach has been tested successfully with data collected on simulation targets. In the future, we will need to further verify the effectiveness of this fusion approach with field data. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detecting Process Equipment Failures Using Acoustic Data and Machine Learning

Nuclear power plant (NPP) process equipment such as fans, motors, valves, and pumps generate frequent or continuous noise, and deviations from the normal operational sounds made by this equipment can indicate potential issues. These deviations can be identified via automated acoustic anomaly detection, which involves using acoustic sensors (i.e., microphones) alongside detection algorithms to continuously monitor for changes in acoustic signatures. This task is made challenging by the substantial background noise that exists, such as operators opening and closing doors, manipulating valves, and conversing—in addition to typical plant noises. In collaboration with a nuclear power utility partner, this effort assessed the efficacy of acoustic anomaly detection when using a specific acoustic sensor that compresses data into a fixed set of features that are transferable over a standard Internet of Things communication protocol, thereby improving usability but potentially degrading detection performance. Two methods of performing automated acoustic anomaly detection were evaluated: one-class support vector machine (OC-SVM) and isolation forest (iForest). To enable the use of high-quality acoustic data encompassing both normal and anomalous conditions, the study utilized the publicly available Malfunctioning Industrial Machine Investigation and Inspection dataset, which includes real measured acoustic sensor data for a range of equipment types, model numbers, and signal-to-noise ratios (SNRs), along with a benchmark set of detection results. Using this dataset, the methods were tested and then compared against the benchmark results. The results indicated that although the specific acoustic sensor did not enable as rich a feature set extraction, the proposed methods with the limited feature set performed just as well. This provides solid justification for both the methods and the use of the proposed acoustic sensor.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Hyper Spectral Anomaly Detection

Anomaly detection is a common machine learning (ML) task with growing importance in the fields of imaging, quality assurance, and multiple security related disciplines. Anomaly detection is more difficult than traditional machine learning methods due to the inherent unlabeled nature of the datasets. Existing anomaly detection architectures commonly face challenges with explainability, retaining information related to the relational structure of the data, and false positive rates. Hyperspectral Imaging Anomaly Detection (HSI) is a statistical model that employs vertex and edge weighted graphs to preserve the data’s relationships on different topographical scales. The model is able to generalize from anomaly detection in 2D images to novel datasets related to cyber-security. Furthermore, the use of multi-spectral and other filtering methods results in fewer false positives and increases the explainability of model predictions. When applying HSI to cyber-security datasets, we are able to successfully detect malicious activity with a relatively high degree of accuracy.

97 - MATHEMATICS AND COMPUTING↗

Kaluza-Klein Dark Matter: Direct Detection vis-a-vis LHC

We explore the phenomenology of Kaluza-Klein (KK) dark matter in very general models with universal extra dimensions (UEDs), emphasizing the complementarity between high-energy colliders and dark matter direct detection experiments. In models with relatively small mass splittings between the dark matter candidate and the rest of the (colored) spectrum, the collider sensitivity is diminished, but direct detection rates are enhanced. UEDs provide a natural framework for such mass degeneracies. We consider both 5-dimensional and 6-dimensional non-minimal UED models, and discuss the detection prospects for various KK dark matter candidates: the KK photon {gamma}{sub 1} (5D) the KK Z-boson Z{sub 1} (5D) and the spinless KK photon {gamma}{sub H} (6D). We combine collider limits such as electroweak precision data and expected LHC reach, with cosmological constraints from WMAP and the sensitivity of current or planned direct detection experiments. Allowing for general mass splittings, we show that neither colliders, nor direct detection experiments by themselves can explore all of the relevant KK dark matter parameter space. Nevertheless, they probe different parameter space regions and the combination of the two types of constraints can be quite powerful. For example, in the case of {gamma}{sub 1} in 5D UEDs the relevant parameter space will be almost completely covered by the combined LHC and direct detection sensitivities expected in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multichannel waveguides for the simultaneous detection of disease biomarkers

The sensor team at the Los Alamos National Laboratory has developed a waveguide-based optical biosensor that has previously been used for the detection of biomarkers associated with diseases such as tuberculosis, breast cancer, anthrax and influenza in complex biological samples (e.g., serum and urine). However, no single biomarker can accurately predict disease. To address this issue, we developed a multiplex assay for the detection of components of the Bacillus anthracis lethal toxin on single mode planar optical waveguides with tunable quantum dots as the fluorescence reporter. This limited ability to multiplex is still insufficient for accurate detection of disease or for monitoring prognosis. In this manuscript, we demonstrate for the first time, the design, fabrication and successful evaluation of a multichannel planar optical waveguide for the simultaneous detection of at least three unknown samples in quadruplicate. We demonstrate the simultaneous, rapid (30 min), quantitative (with internal standard) and sensitive (limit of detection of 1 pM) detection of protective antigen and lethal factor of Bacillus anthracis in complex biological samples (serum) using specific monoclonal antibodies labeled with quantum dots as the fluorescence reporter.

59 BASIC BIOLOGICAL SCIENCES↗

Light-Duty Vehicle Trip Classification Using One-Class Novelty Detection and Exhaustive Feature Extraction

Travel mode classification within travel survey data sets, especially light-duty vehicle (LDV) trips, is foundational, though nontrivial, to emerging mobility systems, travel behavior analysis, and fuel consumption estimation. Current travel mode detection approaches require well-sampled and balanced data sets with ground truth travel mode labels. The detection approaches are rarely applied and validated on large-scale, real-world data sets, which may not satisfy the dataset requirements. This work proposes an LDV trip detection model as a supplement to current travel mode detection methods, for the case when the training set is highly (and/or completely) unbalanced, to the extent that classical machine-learning approaches become difficult or impossible to deploy. The proposed model uses a novelty detection technique - one-class support vector machines (OCSVMs) - and a novel exhaustive feature extraction (EFE) technique on continuous time series data (i.e., Global Positioning System [GPS] speed profiles) for single-mode trip trajectories. Training and validation of the model are conducted on a large-scale, real-world data set. The proposed method accurately identifies LDV trips from a broad set of multimodal trips by leveraging a wealth of preexisting in-vehicle GPS travel data. Additional sensitivity analysis sheds light on the optimal training size and feature selection, which will benefit applications limited by highly imbalanced data. The paper also discusses performance comparison with regular machine-learning approaches, the model's robustness, and the potential to extend the proposed model to multi-modal trip prediction.

33 ADVANCED PROPULSION SYSTEMS↗

Phosphodiesterase (PDE5) inhibition assay for rapid detection of erectile dysfunction drugs and analogs in sexual enhancement products

Abstract Products marketed as dietary supplements for sexual enhancement are frequently adulterated with phosphodiesterase‐5 (PDE5) inhibitors, which are erectile dysfunction drugs or their analogs that can cause adverse health effects. Due to widespread adulteration, a rapid screening assay was developed to detect PDE5 inhibitors in adulterated products. The assay employs fluorescence detection and is based on measuring inhibition of PDE5 activity, the pharmacological mechanism shared among the adulterants. Initially, the assay reaction scheme was established and characterized, followed by analysis of 9 representative PDE5 inhibitors ( IC 50 , 0.4–4.0 ng mL –1 ), demonstrating sensitive detection in matrix‐free solutions. Next, dietary supplements serving as matrix blanks ( n = 25) were analyzed to determine matrix interference and establish a threshold value; there were no false positives. Finally, matrix blanks were spiked with 9 individual PDE5 inhibitors, along with several mixtures. All 9 adulterants were successfully detected (≤ 5 % false negative rate; n = 20) at a concentration of 1.00 mg g –1 , which is over 5 times lower than concentrations commonly encountered in adulterated products. A major distinction of the PDE5 inhibition assay is the ability to detect adulterants without prior knowledge of their chemical structures, demonstrating a broad‐based detection capability that can address a continuously evolving threat of new adulterants. The PDE5 inhibition assay can analyze over 40 samples simultaneously within 15 minutes and involves a single incubation step and simple data analysis, all of which are advantageous for combating the widespread adulteration of sex‐enhancement products.

Santillo, Michael F.↗

Detecting new physics as novelty — Complementarity matters

Novelty detection is a task of machine learning that aims at detecting novel events without a prior knowledge. In particular, its techniques can be applied to detect unexpected signals from new phenomena at colliders. In this paper, we develop an analysis scheme that exploits the complementarity, originally studied in ref. [1], between isolation-based and clustering-based novelty evaluators. This approach can significantly improve the performance and overall applicability of novelty detection at colliders, which we demonstrate using a variety of two dimensional Gaussian samples mimicking collider events. As a further proof of principle, we subsequently apply this scheme to the detection of two significantly different signals at the LHC featuring a $t\bar{t}γγ$ final state: $t\bar{t}h$, giving a narrow resonance in the diphoton mass spectrum, and gravity-mediated supersymmetry, resulting in broad distributions at high transverse momentum. Compared to existing dedicated searches at the LHC, the sensitivities for detecting both signals are found to be encouraging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Delayed-Phase Cone-Beam CT Improves Detectability of Intrahepatic Cholangiocarcinoma During Conventional Transarterial Chemoembolization

PurposeTo evaluate the detectability of intrahepatic cholangiocarcinoma (ICC) on dual-phase cone-beam CT (DPCBCT) during conventional transarterial chemoembolization (cTACE) compared to that of digital subtraction angiography (DSA) with respect to pre-procedure contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis retrospective study included 17 consecutive patients (10 male, mean age 64) with ICC who underwent pre-procedure CE-MRI of the liver, and DSA and DPCBCT (early-arterial phase (EAP) and delayed-arterial phase (DAP)) just before cTACE. The visibility of each ICC lesion was graded by two radiologists on a three-rank scale (complete, partial, and none) on DPCBCT and DSA images, and then compared to pre-procedure CE-MRI.ResultsOf 61 ICC lesions, only 45.9 % were depicted by DSA, whereas EAP- and DAP-CBCT yielded a significantly higher detectability rate of 73.8 % and 93.4 %, respectively (p < 0.01). Out of the 33 lesions missed on DSA, 18 (54.5 %) and 30 (90.9 %) were revealed on EAP- and DAP-CBCT images, respectively. DSA depicted only one lesion that was missed by DPCBCT due to streak artifacts caused by a prosthetic mitral valve. DAP-CBCT identified significantly more lesions than EAP-CBCT (p < 0.01). Conversely, EAP-CBCT did not detect lesions missed by DAP-CBCT. For complete lesion visibility, DAP-CBCT yielded significantly higher detectability (78.7 %) compared to EAP (31.1 %) and DSA (21.3 %) (p < 0.01).ConclusionDPCBCT, and especially the DAP-CBCT, significantly improved the detectability of ICC lesions during cTACE compared to DSA. We recommend the routine use of DAP-CBCT in patients with ICC for per-procedure detectability and treatment planning in the setting of TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Value of Hybrid Angio-CT in Preoperative Detection and Localization of Insulinomas: A Single-Center Retrospective Study

ObjectiveTo investigate the performance of hybrid angio-CT in preoperative detection and localization for insulinomas.MethodsFifty-four postoperative pathology-confirmed patients from April 2015 to March 2017 were retrospectively reviewed; all patients underwent angio-CT with administration of contrast media in SMA, GDA and SA due to negative, inconclusive or controversial findings by several preoperative diagnostic methods including TAUS, CEUS, EUS, ECT, EMRI and DSA. Surgery was used as gold standard for localization of insulinomas; detection sensitivity and localization accuracy of angio-CT were assessed and compared with other preoperative image options.ResultsFifty-six benign insulinomas (mean diameter, 15.8 mm) in 54 patients (18 men and 36 women) were found according to surgical results; the overall detection sensitivity of TAUS, CEUS, EUS, ECT, EMRI and DSA was 21.4, 78.4, 79.2, 70.0, 79.2 and 72.2%, respectively. The overall localization accuracy was 14.3, 58.8, 68.8, 60.0, 75.0 and 44.4%, respectively. A total of 53 tumors were detected by angio-CT, 51 tumors were accurately located, and the overall detection sensitivity and localization accuracy of angio-CT was 94.4 and 90.7%, which was significantly higher than that of all other preoperative diagnostic methods (p < 0.05). No any serious complications occurred during angio-CT.ConclusionOur study indicates the great potential value of angio-CT in the preoperative detection and localization of insulinomas; angio-CT can be used as a preferred invasive diagnostic method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new method for detecting abrupt changes in the dependence among multivariate hydrological series based on moving cut total correlation

Knowledge of how to define and estimate the dependence among multivariate hydrological series is essential for detecting abrupt changes in the dependence. Here, in this paper, a new method (BMCTC) is proposed to detect all possible abrupt change points in the dependence among multivariate hydrological series. The total correlation estimated by the matrix-based Renyi's alpha-order entropy functional is firstly introduced to define and measure the dependence strength among multivariate hydrological series. Then, the moving cut total correlation (MCTC) sequence is built by the moving window technique, which is used to measure changes in the dependence strength among multivariate hydrological series. Finally, the Bernaola-Galvan algorithm is used to detect all change points of the MCTC sequence. Simulations are performed to compare the effectiveness of BMCTC with Pearson correlation (BMCPC) and Spearman correlation (BMCSC), Cramer-von Mises (CvM) and copula-based likelihood-ratio (CLR). The results show that all change points are detected by BMCTC regardless of the samples size, but wrong change points or no change points are detected by other methods in most cases. BMCTC is applied to detect change points in the dependence among annual runoff, precipitation and sediment discharge series in the Xiliugou and the Kuyehe River, China. It is found that the dependence among runoff, precipitation and sediment discharge changed abruptly in 1980 and 1996 in the Kuyehe River and in 1999 in the Xiliugou River. These changes are mainly caused by human activities such as construction of water conservancy projects and coal mining.

54 ENVIRONMENTAL SCIENCES↗

Spatiotemporal pattern detection, generation, and computation with circuits

Abstract Implementations of neurons, delays, and synapse circuits are presented with simulations. These neural elements are used to create two small spiking neural networks, the Rate-Window and Order-Biased clusters, which are capable of detecting simple two-spike spatiotemporal patterns. A simple pattern detecting network (SPDN) is created by combining the Rate-Window and Order-Biased clusters, where clusters are small spiking neural networks, and its simple pattern detection ability is demonstrated in simulation. The SPDN is used to implement a complex pattern detecting network (CPDN) and its complex pattern detection ability is demonstrated in simulation. Methods for generating arbitrary spatiotemporal patterns are presented. The CPDN and spatiotemporal pattern generation methods are then used to implement a novel spatiotemporal computing paradigm based on detecting and responding to spatiotemporal symbols. A simulation of a spatiotemporal half adder is presented to demonstrate the computing paradigm.

97 - MATHEMATICS AND COMPUTING↗