Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Intensive Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Airborne LiDAR to Improve Canopy Fuels Mapping for Wildfire Modeling

Increasing conflict between wildfire and the built environment has increased the need for more up-to-date and finer resolution canopy fuels data to improve wildfire modeling and associated risk forecasts. The US Forest Service and US Department of the Interior’s LANDFIRE product, which provides 30-m resolution canopy fuels data for the entire US, is one of the most widely used sources of fuels data. However, the last complete mapping effort for LANDFIRE is based on 2016 conditions, and subsequent updates reflect disturbances 1-2 years behind the release year. Airborne systems equipped with Light Detection and Ranging (LiDAR) sensors can be deployed to actively sense canopy structure and estimate canopy fuels data (cover, height, base height, bulk density) at finer resolutions. Canopy base height (CBH) and canopy bulk density (CBD) are difficult to measure both in the field and in LiDAR point clouds. Still, they are important for accurately modeling crown fires, which are often intense and difficult to contain. Additionally, point cloud datasets are large, and calculations require efficient utilization of computational resources. To address these challenges, we are working on an approach that uses openly available National Ecological Observatory Network (NEON) airborne LiDAR data, with calculations processed in the R programming language and parallelized through the lidR package. CBH and CBD are often derived from tree height, diameter at breast height, and species-specific allometries using the Fire and Fuels Extension of the Forest Vegetation Simulator (FFE-FVS). We aim to test if airborne LiDAR can estimate CBH and CBD without the use of empirical equations. Reliable estimates of canopy fuels data directly from airborne LiDAR could streamline quick, fine-resolution updates for use in wildfire behavior models.

54 ENVIRONMENTAL SCIENCES↗

Undersizing of aged African biomass burning aerosol by an ultra-high-sensitivity aerosol spectrometer

The ultra-high-sensitivity aerosol spectrometer (UHSAS) differs from most other optical particle spectrometers by using a high-power infrared (IR) laser to detect small particles and reduce the sizing ambiguity due to the non-monotonicity of scattering with particle size. During the NASA ORACLES project (ObseRvations of Aerosols above CLouds and their intEractionS) over the southeast Atlantic Ocean, the UHSAS clearly undersized particles in the biomass burning plume extending from southern Africa. Since the horizontal and vertical extent of the plume was vast, the NASA P-3B research aircraft often flew through a fairly uniform biomass burning plume for periods exceeding 30 min, sufficient time to explore the details of the UHSAS response by selecting single particle sizes with a differential mobility analyzer (DMA) and passing them to the UHSAS. This was essentially an in-flight calibration of the UHSAS using the particles of interest. Two modes of responses appeared. Most particles were undersized by moderate amounts, ranging from not at all for 70 nm aerosols to 15 % for 280 nm particles. Mie scattering calculations show that composition-dependent refractive index of the particles cannot explain the pattern. Heating of brown carbon or tarballs in the beam causing evaporation and shrinking of the particles is the most plausible explanation, though mis-sizing due to non-sphericity cannot be ruled out. A small fraction (10 %–30 %) of the particles were undersized by 25 % to 35 %. Those were apparently the particles containing refractory black carbon. Laboratory calibrations confirm that black carbon is drastically undersized by the UHSAS, because particles heat to their vaporization point and shrink. A simple empirical correction equation was implemented that dramatically improves agreement with DMA distributions between 100 and 500 nm. It raised the median particle diameter by 18 nm, from 163 to 181 nm, during the August 2017 deployment and by smaller amounts during deployments with less intense pollution. Calculated scattering from UHSAS size distributions increased by about 130 %, dramatically improving agreement with scattering measured by nephelometers. The correction is only valid in polluted instances; clean marine boundary layer and free troposphere aerosols behaved more like the calibration spheres. We were unable to directly test the correction between 500 and 1000 nm, though aerodynamic particle sizer (APS) data appear to show that the correction is poor at the largest diameters, which is no surprise as the composition of those particles is likely to be quite different than that of the accumulation mode. This adds to the evidence that UHSAS data must be treated cautiously whenever the aerosol may absorb infrared light. Similar corrections may be required whenever brown carbon aerosol is present.

54 ENVIRONMENTAL SCIENCES↗

ACE-ENA: Best Estimate Aerosol Size Distribution by airborne measurements

These data were collected during the Aerosol and Cloud Experiments in the Eastern North Atlantic field campaign as part of ARM Aerial Facility deployment (ACE-ENA, https://www.arm.gov/research/campaigns/aaf2017ace-ena). The ARM Aerial Facility Gulfstream-1 was deployed at Lajes Air Base (IATA: TER, ICAO: LPLA), on Terceira Island in the Azores, Portugal, for the two Intensive Observation Periods from June 20 through July 22, 2017 (IOP#1) and from January 11 through February 22, 2018 (IOP#2). The G-1 aircraft performed 20+19 research flights over the ARM Eastern North Atlantic (ENA) site and Atlantic Ocean to measure atmospheric turbulence, cloud water content and drop size distributions, aerosol precursor gases, aerosol chemical composition and size distributions. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 4 sensors: two aerosol spectrometers (FIMS and PCASP) and two cloud probes (CAS and FCDP). Aerosol chemical composition, measured by the Aerodyne High Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS), was used to estimate aerosol refractive index (RI) required for correction of the equivalent optical size into geometric size.

54 ENVIRONMENTAL SCIENCES↗

The Effect of Environmental Factors on Total Arsenic Accumulation in Sarcodia suiae, Rhodophyta

Little is known about the effects of environmental factors on total arsenic (TAs) accumulation in marine Rhodophyta. The effects of five environmental factors (temperature, light intensity, pH, exposure duration, and phosphate) at various As(III) concentrations were investigated in Sarcodia suiae. The highest TAs accumulations were recorded at 25°C, a luminance of 80 µmol photons m{sup −2} s{sup −1}, and a pH of 8. TAs uptake increased significantly over time. However, a higher phosphate concentration reduced TAs accumulation. These data show that the extent of TAs accumulation depends on various environmental factors. Hence, our results suggest a potential in arsenic recovery process in wastewater treatments. S. suiae may provide a new means of reducing levels of arsenic in contaminated water and may be used as a potential Rhodophyta model for investigating other types of heavy metal pollution in future.

54 ENVIRONMENTAL SCIENCES↗

Development of the Experimental Setup Dedicated for Alpha, Gamma and Electron Spectroscopy of Heavy Nuclei at FLNR JINR

Various types of reactions and identification techniques were applied in the investigation of formation cross sections and decay properties of transuranium elements. The fusion--evaporation reactions with heavy targets, recoil--separation techniques and identification of nuclei by the parent--daughter generic coincidences with the known daughter-nuclei after implantation into position--sensitive detectors were the most successful tools for production and identification of the heaviest elements known presently. This technique may be further improved and presently it may be very promising for the identification of new elements, search for new isotopes and measurement of new decay data for the known nuclei.At the Flerov Laboratory of Nuclear Reactions (JINR, Dubna), investigations of the complete fusion reactions leading to the synthesis of heavy and superheavy nuclei with the use of heavy ion beams from a powerful U400 cyclotron have been an important part of the experimental program. It is planned to upgrade U400 cyclotron of the FLNR, to deliver beams with higher intensities and smooth variation of energies.New experimental set up, the velocity filter, is now developing for synthesis and studies of the decay properties of heavy nuclei. At the focal plane of the separator GABRIELA set up (alpha,beta,gamma detectors array) will be installed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The AXEAP2 program for K β X-ray emission spectra analysis using artificial intelligence

The processing and analysis of synchrotron data can be a complex task, requiring specialized expertise and knowledge. Our previous work addressed the challenge of X-ray emission spectrum (XES) data processing by developing a standalone application using unsupervised machine learning. However, the task of analyzing the processed spectra remains another challenge. Although the non-resonant K β XES of 3 d transition metals are known to provide electronic structure information such as oxidation and spin state, finding appropriate parameters to match experimental data is a time-consuming and labor-intensive process. Here, a new XES data analysis method based on the genetic algorithm is demonstrated, applying it to Mn, Co and Ni oxides. This approach is also implemented as a standalone application, Argonne X-ray Emission Analysis 2 ( AXEAP2 ), which finds a set of parameters that result in a high-quality fit of the experimental spectrum with minimal intervention. AXEAP2 is able to find a set of parameters that reproduce the experimental spectrum, and provide insights into the 3 d electron spin state, 3 d –3 p electron exchange force and K β emission core-hole lifetime.

36 MATERIALS SCIENCE↗

X-ray Spectral Analysis for Void Fraction Measurement

X-ray attenuation technique has been widely used in two-phase flow measurement. In general, an x-ray system measures the overall attenuation of the two-phase mixture existing between an x-ray source and a detector. One can obtain the void fraction from the intensity of the attenuated x-ray beam and known attenuation coefficients of each phase. Fig. 1 shows a schematic of the line detector system developed at Virginia Tech, and the reconstructed image of a sample slug bubble. The system is capable of obtaining high-resolution (100 {mu}m or less) x-ray images of two-phase flow at a frame rate exceeding 1000 Hz. Note that the intensity of the image can be converted into the line-averaged void fraction data measured by each detector pixel. Typical x-ray systems do not resolve the energy spectrum. Instead, they only measure the total energy deposited in the detector during the exposure period. However, the x-ray source generated from x-ray tubes present polychromatic characteristics. The attenuation coefficient and detector efficiency strongly depend on the energy of x-ray photons. In relation to this, this paper presents the spectral characteristics of a typical x-ray system used for void fraction measurement in two-phase flows. The photon-energy-dependent efficiency of the detector is determined by a calibration test. (authors)

42 ENGINEERING↗

WE-D-9A-02: Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration

Purpose: The anatomical changes that occur between the simulation CT and daily cone-beam CT (CBCT) are investigated using an automated landmark-guided deformable image registration (LDIR) algorithm with simultaneous intensity correction. LDIR was designed to be accurate in the presence of tissue intensity mismatch and heavy noise contamination. Method: An auto-landmark generation algorithm was used in conjunction with a local small volume (LSV) gradient matching search engine to map corresponding landmarks between the CBCT and planning CT. The LSVs offsets were used to perform an initial deformation, generate landmarks, and correct local intensity mismatch. The landmarks act as stabilizing controlpoints in the Demons objective function. The accuracy of the LDIR algorithm was evaluated on one synthetic case with ground truth and data of ten head and neck cancer patients. The deformation vector field (DVF) accuracy was accessed using a synthetic case. The Root mean square error of the 3D canny edge (RMSECE), mutual information (MI), and feature similarity index metric (FSIM) were used to access the accuracy of LDIR on the patient data. The quality of the corresponding deformed contours was verified by an attending physician. Results: The resulting 90 percentile DVF error for the synthetic case was within 5.63mm for the original demons algorithm, 2.84mm for intensity correction alone, 2.45mm using controlpoints without intensity correction, and 1.48 mm for the LDIR algorithm. For the five patients the mean RMSECE of the original CT, Demons deformed CT, intensity corrected Demons CT, control-point stabilized deformed CT, and LDIR CT was 0.24, 0.26, 0.20, 0.20, and 0.16 respectively. Conclusion: LDIR is accurate in the presence of multimodal intensity mismatch and CBCT noise contamination. Since LDIR is GPU based it can be implemented with minimal additional strain on clinical resources. This project has been supported by a CPRIT individual investigator award RP11032.

60 APPLIED LIFE SCIENCES↗

Exploring cosmic origins with CORE: Survey requirements and mission design

Future observations of cosmic microwave background (CMB) polarisation have the potential to answer some of the most fundamental questions of modern physics and cosmology, including: what physical process gave birth to the Universe we see today? What are the dark matter and dark energy that seem to constitute 95% of the energy density of the Universe? Do we need extensions to the standard model of particle physics and fundamental interactions? Is the ΛCDM cosmological scenario correct, or are we missing an essential piece of the puzzle? In this paper, we list the requirements for a future CMB polarisation survey addressing these scientific objectives, and discuss the design drivers of the COREmfive space mission proposed to ESA in answer to the "M5" call for a medium-sized mission. The rationale and options, and the methodologies used to assess the mission's performance, are of interest to other future CMB mission design studies. COREmfive has 19 frequency channels, distributed over a broad frequency range, spanning the 60–600 GHz interval, to control astrophysical foreground emission. The angular resolution ranges from 2' to 18', and the aggregate CMB sensitivity is about 2 μK∙arcmin. The observations are made with a single integrated focal-plane instrument, consisting of an array of 2100 cryogenically-cooled, linearly-polarised detectors at the focus of a 1.2-m aperture cross-Dragone telescope. The mission is designed to minimise all sources of systematic effects, which must be controlled so that no more than 10 -4 of the intensity leaks into polarisation maps, and no more than about 1% of E-type polarisation leaks into B-type modes. COREmfive observes the sky from a large Lissajous orbit around the Sun-Earth L2 point on an orbit that offers stable observing conditions and avoids contamination from sidelobe pick-up of stray radiation originating from the Sun, Earth, and Moon. The entire sky is observed repeatedly during four years of continuous scanning, with a combination of three rotations of the spacecraft over different timescales. With about 50% of the sky covered every few days, this scan strategy provides the mitigation of systematic effects and the internal redundancy that are needed to convincingly extract the primordial B-mode signal on large angular scales, and check with adequate sensitivity the consistency of the observations in several independent data subsets. COREmfive is designed as a "near-ultimate" CMB polarisation mission which, for optimal complementarity with ground-based observations, will perform the observations that are known to be essential to CMB polarisation science and cannot be obtained by any other means than a dedicated space mission. It will provide well-characterised, highly-redundant multi-frequency observations of polarisation at all the scales where foreground emission and cosmic variance dominate the final uncertainty for obtaining precision CMB science, as well as 2' angular resolution maps of high-frequency foreground emission in the 300–600 GHz frequency range, essential for complementarity with future ground-based observations with large telescopes that can observe the CMB with the same beamsize.

79 ASTRONOMY AND ASTROPHYSICS↗

21 cm Power Spectrum Analysis of North Celestial Pole Observations with the Tianlai Dish Pathfinder Array

The Tianlai Dish Pathfinder Array (TDPA) is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization Universe as a means of measuring large-scale cosmic structure. Using nine nights of observations targeting the North Celestial Pole field, totaling approximately 107 hr of integration time, we analyze data in the frequency range 700–800 MHz (corresponding to redshift z ∼ 0.9). We do the data format conversion, radio frequency interference flagging, calibration, imaging and point source subtraction, and foreground removal via Singular Value Decomposition. The spherically averaged power spectrum Δ 2 (k) is obtained. Furthermore, this work successfully establishes and validates a comprehensive data analysis framework for the TDPA. We identify key improvements including sky model refinement, increased integration time, and pipeline optimization that will enable future detection of the 21 cm signal through auto-correlation and cross-correlation with optical galaxy surveys.

cosmology: large-scale structure of universe↗

Temperature dependences of the photoluminescence intensities of centers in silicon implanted with erbium and oxygen ions

Low-temperature photoluminescence in n-Cz-Si after the implantation of erbium ions at an elevated temperature and subsequent implantation of oxygen ions at room temperature is studied. So-called X and W centers formed from self-interstitial silicon atoms, H and P centers containing oxygen atoms, and Er centers containing Er{sup 3+} ions are observed in the photoluminescence spectra. The energies of enhancing and quenching of photoluminescence for these centers are determined. These energies are determined for the first time for X and H centers. In the case of P and Er centers, the values of the energies practically coincide with previously published data. For W centers, the energies of the enhancing and quenching of photoluminescence depend on the conditions of the formation of these centers.

36 MATERIALS SCIENCE↗

Comparison of structure, morphology, and leach characteristics of multi-phase ceramics produced via melt processing and hot isostatic pressing

Melt processing of multi-phase ceramic waste forms offers potential advantages over traditional solid-state synthesis methods given both the prevalence of melters currently in use and the ability to reduce the possibility of airborne radionuclide contamination. In this work, multi-phase ceramics with a targeted hollandite composition of Ba 1.0 Cs 0.3 Cr 1.0 Al 0.3 Fe 1.0 Ti 5.7 O 16 were fabricated by melt processing at 1675 °C and hot isostatic pressing (HIP) at 1250 and 1300 °C. X-ray diffraction analysis (XRD) confirmed hollandite as the major phase in all specimens. Zirconolite/pyrochlore peaks and weaker perovskite reflections were observed after melt processing, while HIP samples displayed prominent perovskite peaks and low-intensity zirconolite reflections. Melt processing produced specimens with large (>50 μm) well-defined hollandite grains, while HIP yielded samples with a more fine-grained morphology. Elemental analysis showed “islands” rich in Cs and Ti across the surface of the 1300 °C HIP sample, suggesting partial melting and partitioning of Cs into multiple phases. Photoemission data revealed multiple Cs 3d spin-orbit pairs for the HIP samples, with the lower binding energy doublets likely corresponding to Cs located in more leachable phases. Among all specimens examined, the melt-processed sample exhibited the lowest fractional release rates for Rb and Cs. However, the retention of Sr and Mo was greater in the HIP specimens.

36 MATERIALS SCIENCE↗

CT image construction of a totally deflated lung using deformable model extrapolation

Purpose: A novel technique is proposed to construct CT image of a totally deflated lung from a free-breathing 4D-CT image sequence acquired preoperatively. Such a constructed CT image is very useful in performing tumor ablative procedures such as lung brachytherapy. Tumor ablative procedures are frequently performed while the lung is totally deflated. Deflating the lung during such procedures renders preoperative images ineffective for targeting the tumor. Furthermore, the problem cannot be solved using intraoperative ultrasound (U.S.) images because U.S. images are very sensitive to small residual amount of air remaining in the deflated lung. One possible solution to address these issues is to register high quality preoperative CT images of the deflated lung with their corresponding low quality intraoperative U.S. images. However, given that such preoperative images correspond to an inflated lung, such CT images need to be processed to construct CT images pertaining to the lung's deflated state. Methods: To obtain the CT images of deflated lung, we present a novel image construction technique using extrapolated deformable registration to predict the deformation the lung undergoes during full deflation. The proposed construction technique involves estimating the lung's air volume in each preoperative image automatically in order to track the respiration phase of each 4D-CT image throughout a respiratory cycle; i.e., the technique does not need any external marker to form a respiratory signal in the process of curve fitting and extrapolation. The extrapolated deformation field is then applied on a preoperative reference image in order to construct the totally deflated lung's CT image. The technique was evaluated experimentally using ex vivo porcine lung. Results: The ex vivo lung experiments led to very encouraging results. In comparison with the CT image of the deflated lung we acquired for the purpose of validation, the constructed CT image was very similar. The intensity mean absolute difference between these two images was calculated to be at 1%. Tumor center as well as a number of anatomical fiducial markers were traced in different corresponding slices of the two images. The average misalignment obtained for the constructed CT image was (0.64, 0.39, 0.11) mm, which indicates a very desirable accuracy for lung brachytherapy applications. Conclusions: The image construction accuracy obtained in this research is suitable for intraoperative tasks; e.g., tumor localization and fusing with real time navigation data in lung brachytherapy. These applications involve image registration with intraoperative U.S. images in order to enhance their poor quality. The proposed technique is also useful for preoperative tasks such as planning of lung brachytherapy treatment.

60 APPLIED LIFE SCIENCES↗

Can Applications Recover from fsync Failures?

We analyze how file systems and modern data-intensive applications react to fsync failures. First, we characterize how three Linux file systems (ext4, XFS, Btrfs) behave in the presence of failures. We find commonalities across file systems (pages are always marked clean, certain block writes always lead to unavailability) as well as differences (page content and failure reporting is varied). Next, we study how five widely used applications (PostgreSQL, LMDB, LevelDB, SQLite, Redis) handle fsync failures. Our findings show that although applications use many failure-handling strategies, none are sufficient: fsync failures can cause catastrophic outcomes such as data loss and corruption. Our findings have strong implications for the design of file systems and applications that intend to provide strong durability guarantees.

Computer Science↗

LEPS2: the second Laser-Electron Photon facility at SPring-8

A new project to construct the second beamline for the laser-electron photon beam at SPring-8 (LEPS2) has started. Based on the LEPS experience, the project aims to improve the intensity of the photon beam and to expand the detector acceptance by adopting the BNL-E949 detector, which is a hermetic detector in a large 1 T solenoid magnet. The central region of tracking chambers will be upgraded for the LEPS2. A new LEPS2 experimental building has just been constructed outside the experimental hall of the storage ring. The present status of the development of a frozen-spin polarized HD target is also reported.

43 PARTICLE ACCELERATORS↗

Defining a Metric Space of Host Logs and Operational Use Cases

Host logs, in particular, Windows Event Logs, are a valuable source of information often collected by security operation centers (SOCs). The semi-structured nature of host logs inhibits automated analytics, and while manual analysis is common, the sheer volume makes manual inspection of all logs impossible. Although many powerful algorithms for analyzing time-series and sequential data exist, utilization of such algorithms for most cyber security applications is either infeasible or requires tailored, research-intensive preparations. In particular, basic mathematic and algorithmic developments for providing a generalized, meaningful similarity metric on system logs is needed to bridge the gap between many existing sequential data mining methods and this currently available but under-utilized data source. In this paper, we provide a rigorous definition of a metric product space on Windows Event Logs, providing an embedding that allows for the application of established machine learning and time-series analysis methods. We then demonstrate the utility and flexibility of this embedding with multiple use-cases on real data: (1) comparing known infected to new host log streams for attack detection and forensics, (2) collapsing similar streams of logs into semantically-meaningful groups (by user, by role), thereby reducing the quantity of data but not the content, (3) clustering logs as well as short sequences of logs to identify and visualize user behaviors and background processes over time. Overall, we provide a metric space framework for general host logs and log sequences that respects semantic similarity and facilitates a wide variety of data science analytics to these logs without data-specific preparations for each.

Verma, Miki↗

Series of compositions Bi{sub 2}(M'{sub x}M{sub 1-x}){sub 4}O{sub 9} (M', M=Al, Ga, Fe; 0{<=}x{<=}1) with mullite-type crystal structure: Synthesis, characterization and {sup 18}O/{sup 16}O exchange experiment

Series of compositions Bi{sub 2}(M'{sub x}M{sub 1-x}){sub 4}O{sub 9} with x=0.0, 0.1,..., 1.0 and M'/M=Ga/Al, Fe/Al and Fe/Ga were synthesized by dissolving appropriate amounts of corresponding metal nitrate hydrates in glycerine, followed by gelation, calcination and final heating at 800 {sup o}C for 24 h. The new compositions with M'/M=Ga/Al form solid-solution series, which are isotypes to the two other series M'/M=Fe/Al and Fe/Ga. The XRD data analysis yielded in all cases a linear dependence of the lattice parameters related on x. Rietveld structure refinements of the XRD patterns of the new compounds, Bi{sub 2}(Ga{sub x}Al{sub 1-x}){sub 4}O{sub 9} reveal a preferential occupation of Ga in tetrahedral site (4 h). The IR absorption spectra measured between 50 and 4000 cm{sup -1} of all systems show systematic shifts in peak positions related to the degree of substitution. Samples treated in {sup 18}O{sub 2} atmosphere (16 h at 800 {sup o}C, 200 mbar, 95% {sup 18}O{sub 2}) for {sup 18}O/{sup 16}O isotope exchange experiments show a well-separated IR absorption peak related to the M-{sup 18}O{sub c}-M vibration, where O{sub c} denotes the common oxygen of two tetrahedral type MO{sub 4} units. The intensity ratio of M-{sup 18}O{sub c}/M-{sup 16}O{sub c} IR absorption peaks and the average crystal sizes were used to estimate the tracer diffusion coefficients of polycrystalline Bi{sub 2}Al{sub 4}O{sub 9} (D=2x10{sup -22} m{sup 2}s{sup -1}), Bi{sub 2}Fe{sub 4}O{sub 9} (D=5x10{sup -21} m{sup 2}s{sup -1}), Bi{sub 2}(Ga/Al){sub 4}O{sub 9} (D=2x10{sup -21} m{sup 2}s{sup -1}) and Bi{sub 2}Ga{sub 4}O{sub 9} (D=2x10{sup -20} m{sup 2}s{sup -1}). - Graphical abstract: Fig. Perspective view of the mullite-type Bi{sub 2}(M'{sub x}M{sub 1-x}){sub 4}O{sub 9} unit cell (M', M=Al, Ga, Fe). Display Omitted

36 MATERIALS SCIENCE↗

Sparse recovery of undersampled intensity patterns for coherent diffraction imaging at high X-ray energies

Coherent X-ray photons with energies higher than 50 keV offer new possibilities for imaging nanoscale lattice distortions in bulk crystalline materials using Bragg peak phase retrieval methods. However, the compression of reciprocal space at high energies typically results in poorly resolved fringes on an area detector, rendering the diffraction data unsuitable for the three-dimensional reconstruction of compact crystals. To address this problem, we propose a method by which to recover fine fringe detail in the scattered intensity. This recovery is achieved in two steps: multiple undersampled measurements are made by in-plane sub-pixel motion of the area detector, then this data set is passed to a sparsity-based numerical solver that recovers fringe detail suitable for standard Bragg coherent diffraction imaging (BCDI) reconstruction methods of compact single crystals. The key insight of this paper is that sparsity in a BCDI data set can be enforced by recognising that the signal in the detector, though poorly resolved, is band-limited. This requires fewer in-plane detector translations for complete signal recovery, while adhering to information theory limits. Lastly, we use simulated BCDI data sets to demonstrate the approach, outline our sparse recovery strategy, and comment on future opportunities.

36 MATERIALS SCIENCE↗