Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of pencil beam–based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo–based recalculation

This study was conducted to ascertain whether homogeneous target dose planning is suitable for stereotactic body radiotherapy (SBRT) of peripheral lung cancer under appropriate breath-holding. For 20 peripheral lung tumors, paired dynamic conformal arc plans were generated by only adjusting the leaf margin to the planning target volume (PTV) edge for fulfilling the conditions such that the prescription isodose surface (IDS) encompassing exactly 95% of the PTV (PTV D{sub 95}) corresponds to 95% and 80% IDS, normalized to 100% at the PTV isocenter under a pencil beam (PB) algorithm with radiologic path length correction. These plans were recalculated using the x-ray voxel Monte Carlo (XVMC) algorithm under otherwise identical conditions, and then compared. Lesions abutting the parietal pleura or not were defined as edge or island tumors, respectively, and the influences of the target volume and its location relative to the chest wall on the target dose were examined. The median (range) leaf margin required for the 95% and 80% plans was 3.9 mm (1.3 to 5.0) and −1.2 mm (−1.8 to 0.1), respectively. Notably, the latter was significantly correlated negatively with PTV. In the 80% plans, the PTV D{sub 95} was slightly higher under XVMC, whereas the PTV D{sub 98} was significantly lower, irrespective of the dose calculation algorithm used. Other PTV and all gross tumor volume doses were significantly higher, while the lung doses outside the PTV were slightly lower. The target doses increased as a function of PTV and were significantly lower for island tumors than for edge tumors. In conclusion, inhomogeneous target dose planning using smaller leaf margin for a larger tumor volume was deemed suitable in ensuring more sufficient target dose while slightly reducing lung dose. In addition, more inhomogeneous target dose planning using <80% IDS (e.g., 70%) for PTV covering would be preferable for island tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients

The purpose of this study was (1) to evaluate dose to skin between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques for target sites in the head and neck, pelvis, and brain and (2) to determine if the treatment dose and fractionation regimen affect the skin dose between traditional sequential boost and integrated boost regimens for patients with head and neck cancer. A total of 19 patients and 48 plans were evaluated. The Eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, and 5 patients with brain cancer with VMAT and static-field IMRT. The mean skin dose and the maximum dose to a contiguous volume of 2 cm{sup 3} for head and neck plans and brain plans and a contiguous volume of 5 cm{sup 3} for pelvis plans were compared for each treatment technique. Of the 9 patients with head and neck cancer, 3 underwent an integrated boost regimen. One integrated boost plan was replanned with IMRT and VMAT using a traditional boost regimen. For target sites located in the head and neck, VMAT reduced the mean dose and contiguous hot spot most noticeably in the shoulder region by 5.6% and 5.4%, respectively. When using an integrated boost regimen, the contiguous hot spot skin dose in the shoulder was larger on average than a traditional boost pattern by 26.5% and the mean skin dose was larger by 1.7%. VMAT techniques largely decrease the contiguous hot spot in the skin in the pelvis by an average of 36% compared with IMRT. For the same target coverage, VMAT can reduce the skin dose in all the regions of the body, but more noticeably in the shoulders in patients with head and neck and pelvis cancer. We also found that using integrated boost regimens in patients with head and neck cancer leads to higher shoulder skin doses compared with traditional boost regimens.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of various methods for rectum delineation on relative and absolute dose-volume histograms for prostate IMRT treatment planning

Several reports have dealt with correlations of late rectal toxicity with rectal dose-volume histograms (DVHs) for high dose levels. There are 2 techniques to assess rectal volume for reception of a specific dose: relative-DVH (R-DVH, %) that indicates relative volume for a vertical axis, and absolute-DVH (A-DVH, cc) with its vertical axis showing absolute volume of the rectum. The parameters of DVH vary depending on the rectum delineation method, but the literature does not present any standardization of such methods. The aim of the present study was to evaluate the effects of different delineation methods on rectal DVHs. The enrollment for this study comprised 28 patients with high-risk localized prostate cancer, who had undergone intensity-modulated radiation therapy (IMRT) with the prescription dose of 78 Gy. The rectum was contoured with 4 different methods using 2 lengths, short (Sh) and long (Lg), and 2 cross sections, rectum (Rec) and rectal wall (Rw). Sh means the length from 1 cm above the seminal vesicles to 1 cm below the prostate and Lg the length from the rectosigmoid junction to the anus. Rec represents the entire rectal volume including the rectal contents and Rw the rectal volume of the area with a wall thickness of 4 mm. We compared dose-volume parameters by using 4 rectal contour methods for the same plan with the R-DVHs as well as the A-DVHs. For the high dose levels, the R-DVH parameters varied widely. The mean of V{sub 70} for Sh-Rw was the highest (19.4%) and nearly twice as high as that for Lg-Rec (10.4%). On the contrary, only small variations were observed in the A-DVH parameters (4.3, 4.3, 5.5, and 5.5 cc for Sh-Rw, Lg-Rw, Sh-Rec, and Lg-Rec, respectively). As for R-DVHs, the parameters of V{sub 70} varied depending on the rectal lengths (Sh-Rec vs Lg-Rec: R = 0.76; Sh-Rw vs Lg-Rw: R = 0.85) and cross sections (Sh-Rec vs Sh-Rw: R = 0.49; Lg-Rec vs Lg-Rw: R = 0.65). For A-DVHs, however, the parameters of Sh rectal A-DVHs hardly changed regardless of differences in rectal length at all dose levels. Moreover, at high dose levels (V{sub 70}), the parameters of A-DVHs showed less dependence on rectal cross sections (Sh-Rec vs Sh-Rw: R = 0.66; Lg-Rec vs Lg-Rw: R = 0.59). This study showed that A-DVHs were less dependent on the delineation methods than R-DVHs, especially for evaluating the rectal dose at higher dose levels. It can therefore be assumed that, in addition to R-DVHs, A-DVHs can be used for evaluating rectal toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels

The aim of this study is to evaluate the incidental testicular doses during prostate radiation therapy with intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) at different energies. Dosimetric data of 15 patients with intermediate-risk prostate cancer who were treated with radiotherapy were analyzed. The prescribed dose was 78 Gy in 39 fractions. Dosimetric analysis compared testicular doses generated by 7-field intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy with a single arc at 6, 10, and 15 MV energy levels. Testicular doses calculated from the treatment planning system and doses measured from the detectors were analyzed. Mean testicular doses from the intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy per fraction calculated in the treatment planning system were 16.3 ± 10.3 cGy vs 21.5 ± 11.2 cGy (p = 0.03) at 6 MV, 13.4 ± 10.4 cGy vs 17.8 ± 10.7 cGy (p = 0.04) at 10 MV, and 10.6 ± 8.5 cGy vs 14.5 ± 8.6 cGy (p = 0.03) at 15 MV, respectively. Mean scattered testicular doses in the phantom measurements were 99.5 ± 17.2 cGy, 118.7 ± 16.4 cGy, and 193.9 ± 14.5 cGy at 6, 10, and 15 MV, respectively, in the intensity-modulated radiotherapy plans. In the volumetric-modulated arc radiotherapy plans, corresponding testicular doses per course were 90.4 ± 16.3 cGy, 103.6 ± 16.4 cGy, and 139.3 ± 14.6 cGy at 6, 10, and 15 MV, respectively. In conclusions, this study was the first to measure the incidental testicular doses by intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy plans at different energy levels during prostate-only irradiation. Higher photon energy and volumetric-modulated arc radiotherapy plans resulted in higher incidental testicular doses compared with lower photon energy and intensity-modulated radiotherapy plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric-modulated arc therapy (VMAT) for whole brain radiotherapy: not only for hippocampal sparing, but also for reduction of dose to organs at risk

A prospective clinical trial, Radiation Therapy Oncology Group (RTOG) 0933, has demonstrated that whole brain radiotherapy (WBRT) using conformal radiation delivery technique with hippocampal avoidance is associated with less memory complications. Further sparing of other organs at risk (OARs) including the scalp, ear canals, cochleae, and parotid glands could be associated with reductions in additional toxicities for patients treated with WBRT. We investigated the feasibility of WBRT using volumetric-modulated arc therapy (VMAT) to spare the hippocampi and the aforementioned OARs. Ten patients previously treated with nonconformal WBRT (NC-WBRT) using opposed lateral beams were retrospectively re-planned using VMAT with hippocampal sparing according to the RTOG 0933 protocol. The OARs (scalp, auditory canals, cochleae, and parotid glands) were considered as dose-constrained structures. VMAT plans were generated for a prescription dose of 30 Gy in 10 fractions. Comparison of the dosimetric parameters achieved by VMAT and NC-WBRT plans was performed using paired t-tests using upper bound p-value of 100% ) of 8.4 ± 0.3 Gy and maximum dose of 15.6 ± 0.4 Gy, respectively. A statistically significant dose reduction (p < 0.001) to all OARs was achieved. The mean and maximum scalp doses were reduced by an average of 9 Gy (32%) and 2 Gy (6%), respectively. The mean and maximum doses to the auditory canals were reduced from 29.5 ± 0.5 Gy and 31.0 ± 0.4 Gy with NC-WBRT, to 21.8 ± 1.6 Gy (26%) and 27.4 ± 1.4 Gy (12%) with VMAT. VMAT also reduced mean and maximum doses to the cochlea by an average of 4 Gy (13%) and 2 Gy (6%), respectively. The parotid glands mean and maximum doses with VMAT were 4.4 ± 1.9 Gy and 15.7 ± 5.0 Gy, compared to 12.8 ± 4.9 Gy and 30.6 ± 0.5 Gy with NC-WBRT, respectively. The average dose reduction of mean and maximum of parotid glands from VMAT were 65% and 50%, respectively. The average beam on time and MUs were 2.3minutes and 719 on VMAT, and 0.7 minutes and 350 on NC-WBRT. This study demonstrated the feasibility of WBRT using VMAT to not only spare the hippocampi, but also significantly reduce dose to OARs. These advantages of VMAT could potentially decrease the toxicities associated with NC-WBRT and improve patients' quality of life, especially for patients with favorable prognosis receiving WBRT or patients receiving prophylactic cranial irradiation (PCI).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modulation of DNA polymerase beta-dependent base excision repair in cultured human cells after low dose exposure to arsenite

Base excision repair (BER) is crucial for development and for the repair of endogenous DNA damage. However, unlike nucleotide excision repair, the regulation of BER is not well understood. Arsenic, a well-established human carcinogen, is known to produce oxidative DNA damage, which is repaired primarily by BER, whilst high doses of arsenic can also inhibit DNA repair. However, the mechanism of repair inhibition by arsenic and the steps inhibited are not well defined. To address this question we have investigated the regulation of DNA polymerase {beta} (Pol {beta}) and AP endonuclease (APE1), in response to low, physiologically relevant doses of arsenic. GM847 lung fibroblasts and HaCaT keratinocytes were exposed to sodium arsenite, As(III), and mRNA, protein levels and BER activity were assessed. Both Pol {beta} and APE1 mRNA exhibited significant dose-dependant down regulation at doses of As(III) above 1 {mu}M. However, at lower doses Pol {beta} mRNA and protein levels, and consequently, BER activity were significantly increased. In contrast, APE1 protein levels were only marginally increased by low doses of As(III) and there was no correlation between APE1 and overall BER activity. Enzyme supplementation of nuclear extracts confirmed that Pol {beta} was rate limiting. These changes in BER correlated with overall protection against sunlight UV-induced toxicity at low doses of As(III) and produced synergistic toxicity at high doses. The results provide evidence that changes in BER due to low doses of arsenic could contribute to a non-linear, threshold dose response for arsenic carcinogenesis.

60 APPLIED LIFE SCIENCES↗

Ventilatory effects of low-dose paraoxon result from central muscarinic effects

Paraoxon induces respiratory toxicity. Atropine completely reversed parathion- and paraoxon-induced respiratory toxicity. The aim of this study was to assess the peripheral or central origin of ventilatory effects of low-dose paraoxon. Male Sprague-Dawley rats were given paraoxon 0.215 mg/kg subcutaneously and treated with either atropine (10 mg/kg sc) or ascending doses of methylatropine of 5.42 (equimolar to that of atropine), 54.2, and 542 mg/kg administered subcutaneously 30 min after paraoxon. Ventilation at rest was assessed using whole-body plethysmography and rat temperature using infra-red telemetry. Results are expressed as mean {+-} SE. Statistical analysis used two-way ANOVA for repeated measurements. Paraoxon induced a significant decrease in temperature 30 min after injection lasting the 90 min of the study period. This effect was partially corrected by atropine, but not by methylatropine whatever the dose. Paraoxon induced a decrease in respiratory rate resulting from an increase in expiratory time associated with an increase in tidal volume. Atropine completely reversed the ventilatory effects of low-dose paraoxon while the equimolar dose of methylatropine had no significant effects. The 54.2 and 542 mg/kg doses of methylatropine had no significant effects. Atropine crosses the blood-brain barrier and reverses peripheral and central muscarinic effects. In contrast, methylatropine does not cross the blood-brain barrier. Atropine completely reversed the ventilatory effects of low-dose paraoxon, while methylatropine had no significant effects at doses up to 100-fold the equimolar dose of atropine. We conclude that the ventilatory effects of low-dose paraoxon are mediated by disrupted muscarinic signaling in the central nervous system.

60 APPLIED LIFE SCIENCES↗

Pulmonary instillation of low doses of titanium dioxide nanoparticles in mice leads to particle retention and gene expression changes in the absence of inflammation

We investigated gene expression, protein synthesis, and particle retention in mouse lungs following intratracheal instillation of varying doses of nano-sized titanium dioxide (nano-TiO{sub 2}). Female C57BL/6 mice were exposed to rutile nano-TiO{sub 2} via single intratracheal instillations of 18, 54, and 162 μg/mouse. Mice were sampled 1, 3, and 28 days post-exposure. The deposition of nano-TiO{sub 2} in the lungs was assessed using nanoscale hyperspectral microscopy. Biological responses in the pulmonary system were analyzed using DNA microarrays, pathway-specific real-time RT-PCR (qPCR), gene-specific qPCR arrays, and tissue protein ELISA. Hyperspectral mapping showed dose-dependent retention of nano-TiO{sub 2} in the lungs up to 28 days post-instillation. DNA microarray analysis revealed approximately 3000 genes that were altered across all treatment groups (± 1.3 fold; p < 0.1). Several inflammatory mediators changed in a dose- and time-dependent manner at both the mRNA and protein level. Although no influx of neutrophils was detected at the low dose, changes in the expression of several genes and proteins associated with inflammation were observed. Resolving inflammation at the medium dose, and lack of neutrophil influx in the lung fluid at the low dose, were associated with down-regulation of genes involved in ion homeostasis and muscle regulation. Our gene expression results imply that retention of nano-TiO{sub 2} in the absence of inflammation over time may potentially perturb calcium and ion homeostasis, and affect smooth muscle activities. - Highlights: • Pulmonary effects following exposure to low doses of nano-TiO{sub 2} were examined. • Particle retention in lungs was assessed using nanoscale hyperspectral microscopy. • Particles persisted up to 28 days in lungs in all dose groups. • Inflammation was the pathway affected in the high dose group at all time points. • Ion homeostasis and muscle activity pathways were affected in the low dose group.

60 APPLIED LIFE SCIENCES↗

Low dose evaluation of the antiandrogen flutamide following a Mode of Action approach

ABSTRACT: The dose–response characterization of endocrine mediated toxicity is an on-going debate which is controversial when exploring the nature of the dose–response curve and the effect at the low-end of the curve. To contribute to this debate we have assessed the effects of a wide range of dose levels of the antiandrogen flutamide (FLU) on 7-week male Wistar rats. FLU was administered by oral gavage at doses of 0, 0.001, 0.01, 0.1, 1 and 10 mg/kg/day for 28 days. To evaluate the reproducibility, the study was performed 3 times. The molecular initiating event (MIE; AR antagonism), the key events (LH increase, Leydig cell proliferation and hyperplasia increases) and associated events involved in the mode of action (MOA) of FLU induced testicular toxicity were characterized to address the dose response concordance. Results showed no effects at low doses (< 0.1 mg/kg/day) for the different key events studied. The histopathological changes (Leydig cell hyperplasia) observed at 1 and 10 mg/kg/day were associated with an increase in steroidogenesis gene expression in the testis from 1 mg/kg/day, as well as an increase in testosterone blood level at 10 mg/kg/day. Each key event dose–response was in good concordance with the MOA of FLU on the testis. From the available results, only monotonic dose–response curves were observed for the MIE, the key events, associated events and in effects observed in other sex related tissues. All the results, so far, show that the reference endocrine disruptor FLU induces threshold effects in a standard 28-day toxicity study on adult male rats. - Highlights: • Dose–response characterization of endocrine mediated toxicity is an on-going debate. • A wide range of dose levels of flutamide was evaluated on young adult male rats. • Flutamide induces threshold effects using on standard and molecular tools.

60 APPLIED LIFE SCIENCES↗

In vivo dosimetry for estimation of effective doses in multislice CT coronary angiography

In vivo dosimetry represents a technique that has been widely employed to evaluate the dose to the patient mainly in radiotherapy. Considering the increment in dose to the population due to new high-dose multislice CT examinations, such as coronary angiography, it is becoming important to more accurately know the dose to the patient. The desire to know patient dose extends even to radiological examinations. Thermoluminescent dosimeters are considered the gold standard for in vivo dosimetry, but their use is time consuming. A rapid, less labor-intensive method has been developed to perform in vivo dosimetry using radiochromic film positioned next to the patient's skin. Multislice CT scanners allow the estimation of the effective dose to the patient from the dose length product (DLP) parameter, the value of which is displayed on the acquisition console, simply multiplying the DLP by published conversion factors. The method represents only an approximation based on standard size circular phantoms and neglects the actual size of the patient. More accurate evaluations can be carried out using software-based Monte Carlo simulations. However, these methods do not consider possible dose reduction techniques, such as automatic tube-current modulation. For 22 patients effective doses measured by in vivo dosimetry and calculated by software were compared. The technique of using in vivo dosimetry measured with radiochromic film appears a promising procedure for improving the assessment of the effective dose to the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy

Brachytherapy dose calculations based on point kernel superposition using the collapsed cone method have been shown to accurately model the influence from finite dimensions of the patient and effects from heterogeneities including those of high atomic numbers. The collapsed cone method is for brachytherapy applications most effectively implemented through a successive-scattering approach, in which the dose from once and higher order of scattered photons is calculated separately and in successive scatter order. The calculation speed achievable is directly proportional to the number of directions used for point kernel discretization and to the number of voxels in the volume. In this work we investigate how to best divide the total number of directions between the two steps of successive-scattering dose calculations. Results show that the largest fraction of the total number of directions should be utilized in calculating the first-scatter dose. Also shown is how the number of directions required for keeping discretization artifacts at acceptably low levels decreases significantly in multiple-source configurations, as a result of the dose gradients being less steep than those around single sources. Investigating the number of kernel directions required to keep artifacts low enough within the high dose region of an implant (i.e., for dose levels above approximately 5%-10% of the mean central target dose) reveals similar figures for brachytherapy as for external beam applications, where collapsed cone superposition is clinically used. Also shown is that approximating point kernels with their isotropic average leads to small dose differences at low and intermediate energies, implying that the collapsed cone calculations can be done in a single operation common to all sources of the implant at these energies. The current findings show that collapsed cone calculations can be achieved for brachytherapy with the same efficiency as for external beams. This, combined with recent results on gains in efficiency through implementing the algorithm on graphical card parallel hardware indicates that dose can be calculated with account for heterogeneities and finite dimensions within a few seconds for large voxel arrays and is therefore of interest for practical application to treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inclusion of the dose from kilovoltage cone beam CT in the radiation therapy treatment plans

Purpose: Cone beam CT is increasingly being used for daily patient positioning verification during radiation therapy treatments. The daily use of CBCT could lead to accumulated patient doses higher than the older technique of weekly portal imaging. There have been several studies focusing on measurement or calculation of the patient dose from CBCT recently. Methods: This study investigates the feasibility of configuring a kV x-ray source in a commercial treatment planning system to calculate the dose to patient resulting from an IGRT procedure. The method proposed in this article can be used to calculate dose from CBCT imaging procedure and include that in the patient treatment plans. Results: The kilovoltage beam generated by the CBCT imager has been modeled using the planning system. The modeled profiles agree with the measured ones to within 5%. The modeled beam was used to calculate dose to phantom in the pelvic region and the calculations were compared to TLD measurements. The agreement between calculated and measured doses ranges from 0% to 19% in soft tissue with larger variations observed near and within the bone. Conclusions: The modeling of the beam produces reasonable results and the dose calculation comparisons indicate the potential for computing kilovoltage CBCT doses using a treatment planning system. Further improvements in the dose calculation algorithm are necessary, especially for dose calculations in and near the bone.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing

Purpose: Both the AccuBoost D-shaped and round applicators have been dosimetrically characterized and clinically used to treat patients with breast cancer. While the round applicators provide conformal dose coverage, under certain clinical circumstances the breast skin dose may be higher than preferred. The purpose of this study was to modify the round applicators to minimize skin dose while not substantially affecting dose uniformity within the target volume and reducing the treatment time. Methods: In order to irradiate the intended volume while sparing critical structures such as the skin, the current round applicator design has been augmented through the addition of an internal truncated cone (i.e., frustum) shield. Monte Carlo methods and clinical constraints were used to design the optimal cone applicator. With the cone applicator now defined as the entire assembly including the surrounding tungsten-alloy shell holding the HDR {sup 192}Ir source catheter, the applicator height was reduced to diminish the treatment time while minimizing skin dose. Monte Carlo simulation results were validated using both radiochromic film and ionization chamber measurements based on established techniques. Results: The optimal cone applicators diminished the maximum skin dose by 15%-32% (based on the applicator diameter and breast separation) with the tumor dose reduced by less than 3% for a constant exposure time. Furthermore, reduction in applicator height diminished the treatment time by up to 30%. Radiochromic film and ionization chamber dosimetric results in phantom agreed with Monte Carlo simulation results typically within 3%. Larger differences were outside the treatment volume in low dose regions or associated with differences between the measurement and Monte Carlo simulation environments. Conclusions: A new radiotherapy treatment device was developed and dosimetrically characterized. This set of applicators significantly reduces the skin dose and treatment time while retaining uniform target dose.

60 APPLIED LIFE SCIENCES↗

Fluence field optimization for noise and dose objectives in CT

Purpose: Selecting the appropriate imaging technique in computed tomography (CT) inherently involves balancing the tradeoff between image quality and imaging dose. Modulation of the x-ray fluence field, laterally across the beam, and independently for each projection, may potentially meet user-prescribed, regional image quality objectives, while reducing radiation to the patient. The proposed approach, called fluence field modulated CT (FFMCT), parallels the approach commonly used in intensity-modulated radiation therapy (IMRT), except ''image quality plans'' replace the ''dose plans'' of IMRT. This work studies the potential noise and dose benefits of FFMCT via objective driven optimization of fluence fields. Methods: Experiments were carried out in simulation. Image quality plans were defined by specifying signal-to-noise ratio (SNR) criteria for regions of interest (ROIs) in simulated cylindrical and oblong water phantoms, and an anthropomorphic phantom with bone, air, and water equivalent regions. X-ray fluence field patterns were generated using a simulated annealing optimization method that attempts to achieve the spatially-dependent prescribed SNR criteria in the phantoms while limiting dose (to the volume or subvolumes). The resulting SNR and dose distributions were analyzed and compared to results using a bowtie filtered fluence field. Results: Compared to using a fixed bowtie filtered fluence, FFMCT achieved superior agreement with the target image quality objectives, and resulted in integral dose reductions ranging from 39 to 52%. Prioritizing dose constraints for specific regions of interest resulted in a preferential reduction of dose to those regions with some tradeoff in SNR, particularly where the target low dose regions overlapped with regions where high SNR was prescribed. The method appeared fairly robust under increased complexity and heterogeneity of the object structure. Conclusions: These results support that FFMCT has the potential to meet prescribed image quality objectives, while decreasing radiation exposure to the patient. Tradeoffs between SNR and dose may not be eliminated, but might be more efficiently managed using FFMCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in dose with segmentation of breast tissues in Monte Carlo calculations for low-energy brachytherapy

Purpose: To investigate the use of various breast tissue segmentation models in Monte Carlo dose calculations for low-energy brachytherapy. Methods: The EGSnrc user-code BrachyDose is used to perform Monte Carlo simulations of a breast brachytherapy treatment using TheraSeed Pd-103 seeds with various breast tissue segmentation models. Models used include a phantom where voxels are randomly assigned to be gland or adipose (randomly segmented), a phantom where a single tissue of averaged gland and adipose is present (averaged tissue), and a realistically segmented phantom created from previously published numerical phantoms. Radiation transport in averaged tissue while scoring in gland along with other combinations is investigated. The inclusion of calcifications in the breast is also studied in averaged tissue and randomly segmented phantoms. Results: In randomly segmented and averaged tissue phantoms, the photon energy fluence is approximately the same; however, differences occur in the dose volume histograms (DVHs) as a result of scoring in the different tissues (gland and adipose versus averaged tissue), whose mass energy absorption coefficients differ by 30%. A realistically segmented phantom is shown to significantly change the photon energy fluence compared to that in averaged tissue or randomly segmented phantoms. Despite this, resulting DVHs for the entire treatment volume agree reasonably because fluence differences are compensated by dose scoring differences. DVHs for the dose to only the gland voxels in a realistically segmented phantom do not agree with those for dose to gland in an averaged tissue phantom. Calcifications affect photon energy fluence to such a degree that the differences in fluence are not compensated for (as they are in the no calcification case) by dose scoring in averaged tissue phantoms. Conclusions: For low-energy brachytherapy, if photon transport and dose scoring both occur in an averaged tissue, the resulting DVH for the entire treatment volume is reasonably accurate because inaccuracies in photon energy fluence are compensated for by inaccuracies in localized dose scoring. If dose to fibroglandular tissue in the breast is of interest, then the inaccurate photon energy fluence calculated in an averaged tissue phantom will result in inaccurate DVHs and average doses for those tissues. Including calcifications necessitates the use of proper tissue segmentation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Skin dose mapping for fluoroscopically guided interventions

Purpose: To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. Methods: In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Results: Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. Conclusions: The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of secondary neutron dose in proton therapy resulting from the use of a tungsten alloy MLC or a brass collimator system

Purpose: To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. Methods: Hydrogenous and nonhydrogenous ionization chambers were constructed with large volumes to enable measurements of absorbed doses below 10{sup -4} Gy in mixed radiation fields using the dual ionization chamber method for mixed-field dosimetry. Neutron dose measurements were made with a nominal 230 MeV proton beam incident on a closed tungsten alloy MLC and a solid brass block. The chambers were cross-calibrated against a {sup 60}Co-calibrated Farmer chamber in water using a 6 MV x-ray beam and Monte Carlo simulations were performed to account for variations in ionization chamber response due to differences in secondary neutron energy spectra. Results: The neutron and combined proton plus {gamma}-ray absorbed doses are shown to be nearly equivalent downstream from either a closed tungsten alloy MLC or a solid brass block. At 10 cm downstream from the distal edge of the collimating material the neutron dose from the closed MLC was (5.3 {+-} 0.4) x 10{sup -5} Gy/Gy. The neutron dose with brass was (6.4 {+-} 0.7) x 10{sup -5} Gy/Gy. Further from the secondary neutron source, at 50 cm, the neutron doses remain close for both the MLC and brass block at (6.9 {+-} 0.6) x 10{sup -6} Gy/Gy and (6.3 {+-} 0.7) x 10{sup -6} Gy/Gy, respectively. Conclusions: The dual ionization chamber method is suitable for measuring secondary neutron doses resulting from proton irradiation. The results of measurements downstream from a closed tungsten alloy MLC and a brass block indicate that, even in an overly pessimistic worst-case scenario, secondary neutron production in a tungsten alloy MLC leads to absorbed doses that are nearly equivalent to those seen from brass collimators. Therefore, the choice of tungsten alloy in constructing the leaves of a proton MLC is appropriate, and does not lead to a substantial increase in the secondary neutron dose to the patient compared to that generated in a brass collimator.

61 RADIATION PROTECTION AND DOSIMETRY↗