Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Reference Site Condition Datasets for Floating Wind Arrays in the United States

Floating offshore wind farm design is highly site-specific, requiring detailed information about the specific conditions of a project area for realistic design studies. Unfortunately, publicly available site condition data for potential floating offshore wind project sites in the United States is scarce. To support U.S. offshore wind research, we developed reference site condition datasets, including metocean and seabed information, for four potential floating wind project areas in the U.S.: Humboldt Bay, Morro Bay, the Gulf of Maine, and the Gulf of Mexico. These datasets were compiled using publicly available data. Our metocean analysis, covering wind, waves, and surface currents, utilized measurement data from 2000 to 2020. Sources included the National Renewable Energy Laboratory’s National Offshore Wind Dataset for wind data, National Data Buoy Center buoys for wave data, and the High Frequency Radar Network for surface currents. These data were integrated into hourly time series used to compute extreme return periods up to 500 years, monthly statistics, and joint probability clusters for fatigue analysis. Soil conditions were evaluated using the usSEABED database and bathymetry grids were interpolated from the NCEI Digital Elevation Model Global Mosaic. Further information on the datasets and how they were created can be found in: Biglu, M., M. Hall, E. Lozon, S. Housner. 2024. Reference Site Conditions for Floating Wind Arrays in the United States. Golden, CO: National Renewable Energy Laboratory (NREL). NREL/TP-5000-89897. The data are also available at: https://github.com/FloatingArrayDesign/SiteConditions The content of each dataset is as follows: _NOW23_wind.txt: Hourly NOW-23 wind data up to a height of 400 meter. _metocean_1hr.txt: Hourly time series including wind, wave, surface current and temperature data. _Summary.xlsx: Metocean data, including extreme values, joint probability distributions and monthly statistics. _usSEABED_soil.csv: Extract of the usSEABED database for this specific site. _bathymetry_200m.txt (and 500m, 1000m): Gridded seabed depth data.

16 TIDAL AND WAVE POWER↗

Transfer Orbit Plasma Interaction Experiment (TROPIX)

Viewgraphs on the Transfer Orbit Plasma Interaction Experiment (TROPIX) are presented. Objectives of this research are (1) to map the charged particles in Earth's magnetosphere from LEO to GEO at high inclinations; (2) to measure plasma current collection and resulting shifts in vehicle electrical potential from LEO to GEO across range of orbital inclinations; (3) to study spacecraft interaction with plasma environment using solar electric propulsion (SEP) thrusters as plasma contactors; (4) to measure array degradation over mission duration; (5) to evaluate the potential of various microelectronics, spacecraft components, and instruments for future space missions; and (6) to demonstrate SEP technology applied to a flight vehicle. An overview of TROPIX is presented.

Hickman, Mark↗

Mechanism of enhanced critical fields and critical current densities of MgB2 wires with C/Dy$^{2}$O3 co-additions

A series of monofilamentary powder-in-tube MgB2 wires were fabricated with 2 mol. % C doping and co-additions of 0–3 wt. % Dy2O3. Irreversibility fields (μ0Hirr), upper critical fields (μ0Hc2), and transport critical currents were measured, and from these quantities, anisotropies (γ) and electronic diffusivities (Dπ,σ) were estimated. The addition of 1 wt. % Dy2O3 to already optimally C-doped MgB2 wires produced higher Hc2//ab, Hc2//c, and Hirr values at 4.2 K. In addition, the critical current density, Jc, increased with Dy2O3 concentration up to 1 wt. % where non-barrier Jc reached 4.35 × 104 A/cm2 at 4.2 K, 10 T. At higher temperatures, for example, 20 K and 5 T, co-additions of 2 mol. % C and 2 wt. % Dy2O3 improved non-barrier Jc by 40% and 93% compared to 2 and 3 mol. % C doping, respectively. On the other hand, measurements of Tc showed that C/Dy2O3 co-additions increase interband scattering rates at a lower rate than C doping does (assuming C doping levels giving similar levels of low-T μ0Hc2 increase as co-addition). Comparisons to a two-band model for μ0Hc2 in MgB2 allowed us to conclude that the increases in Hc2//ab, Hc2//c, and Hirr (as well as concomitant increases in high-field Jc) with Dy2O3 addition are consistent with increases primarily in intraband scattering. This suggests C/Dy2O3 co-addition to be a more promising candidate for improving non-barrier Jc of MgB2 at temperatures above 20 K.

36 MATERIALS SCIENCE↗

Heavy doping considerations and measurements in high-efficiency cells

Theoretical work on heavily doped silicon was described. Heavily doped polysilicon was used as a back-surface passivant replacing the usual back-surface field (BSF). Very good first results were achieved and there is the promise of a simple, low temperature deposition process. Short-circuit current-decay measurement methods were also covered.

Lindholm, F.↗

Room temperature depinning of the charge-density waves in quasi-two-dimensional 1T-TaS 2 devices

Here we report on the depinning of nearly commensurate charge-density waves in 1T-TaS 2 thin films at room temperature. A combination of the differential current–voltage measurements with the low-frequency noise spectroscopy provides unambiguous means for detecting the depinning threshold field in quasi-2D materials. The depinning process in 1T-TaS 2 is not accompanied by an observable abrupt increase in electric current—in striking contrast to depinning in the conventional charge-density-wave materials with quasi-1D crystal structure. We explained it by the fact that the current density from the charge-density waves in the 1T-TaS 2 devices is orders of magnitude smaller than the current density of the free carriers available in the discommensuration network surrounding the commensurate charge-density wave islands. The depinning fields in 1T-TaS 2 thin-film devices are several orders of magnitude larger than those in quasi-1D van der Waals materials. Obtained results are important for the proposed applications of the charge-density wave devices in electronics.

2D materials↗

Spectroscopic determination of electrical conductivity in an MHD duct from absolute intensity measurements

Measurements of the electrical conductivity in the NASA Lewis cesium seeded, H2-O2 MHD duct made by applying a voltage across the channel from one end electrode to the other, measuring the current, and using the inner electrodes as probes to monitor the voltage distribution along the channel were found to be in good agreement with theory except at low combustion pressures and/or high ratios of seed/oxygen mass flows. To corroborate these measurements and to analyze the possibility of nonuniform seed injection as a cause of the above deviations, a spectroscopic investigation of the plasma conductivity was undertaken. Radial profiles of emission coefficient were obtained from measured transverse profiles of the absolute integrated intensity by Abel inversion. Radial profiles of electrical conductivity were then obtained under two different assumptions. In the first the Cs seed fraction is assumed uniform and equal to the measured flow rate at the time when the temperature and conductivity were obtained. In the second method the local temperature and pressure are taken to be those given by a one-dimensional channel calculation including heat transfer and friction. The results of the two methods are compared to the previously measured conductivity.

Wang, S. Y.↗

Measuring Hydrogen Concentrations in Metals

Commercial corrosion-measurement system adapted to electrochemical determination of hydrogen concentrations in metals. New technique based on diffusion of hydrogen through foil specimen of metal. In sample holder, hydrogen produced on one side of foil, either by corrosion reaction or by cathodic current. Hydrogen diffused through foil removed on other side by constant anode potential, which leads to oxidation of hydrogen to water. Anode current is measure of concentration of hydrogen diffusing through foil. System used to study hydrogen uptake, hydrogen elimination by baking, effect of heat treatment, and effect of electroplating on high-strength steels.

Danford, M. D.↗

Electrostatic charging of electrically active spacecraft

A model is presented which predicts the temporal behavior of the ionospheric charging of spacecraft which eject energetic positive ions. The dynamic interaction of the spacecraft with the space-plasma environment is modelled as an equivalent electrical circuit consisting of a variable capacitor in parallel with two current sources. The spacecraft/space-plasma sheath is modelled as a variable capacitor containing positive-ion space charge. The ejection of energetic positive ions from the spacecraft represents a current source which charges the capacitor. Return current collected from the space-plasma sheath to the spacecraft is modelled as a variable current source which discharges the capacitor. The model can predict the temporal behavior of sheath movement, spacecraft potential, and space-plasma return current for a wide range of altitude, duty cycle, and ejected positive-ion current. Experimentally measured charging results, obtained for the Satellite Positive Ion Beam System (SPIBS) rocket flight, are accurately predicted by the model. Anticipated vehicle charging levels are presented for neutral-particle-beam platforms operating with a net, unneutralized, positive-ion-current component present in the emitted neutral-particle beam.

Matossian, J. N.↗

Advanced electric propulsion research - 1990

An experimental study of impingement current collection on the accelerator grid of an ion thruster is presented. The equipment, instruments, and procedures being used to conduct the study are discussed. The contribution to this current due to charge-exchange ions produced close to the grid is determined using a volume-integration procedure and measured ion beam current design, computed neutral atom density and measured beam plasma potential data. This current, which is expected to be almost equal to that measured directly, is found to be an order of magnitude less. The impingement current determined by integrating the current density of ambient ions in the beam plasma close to the grid is found to agree with the directly measured impingement current. Possible reasons for the disagreement between the directly measured and volume integrated impingement currents are discussed.

Monheiser, Jeffery M.↗

Space-based Measurements of Neutron Lifetime: A Novel Approach to a Long-standing Problem

Free neutrons decay via the weak interaction with a mean lifetime of around 15 minutes. Knowledge of this lifetime is important as it provides constraints on the unitarity of the CKM matrix and is a key parameter for studies of Big-Bang nucleosynthesis. However, current laboratory measurements differ by as much as 5σ. We are investigating a new technique to measure neutron lifetime: space-based neutron spectroscopy. We will complete a proof-of-principle demonstration using data from NASA’s MESSENGER mission to Mercury.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discharge characteristics of a simulated solar cell array

Measurements of the transient characteristics associated with the discharge of a simulated solar array are presented. A capacitively coupled probe is used to measure the discharge current, and antennas are used to measure the electromagnetic radiation. Discharges were observed at low surface voltages and several modes of discharge were observed. The maximum discharge current is found to be 0.2 A. This value is several orders of magnitude higher than that reported by previous measurements. Experimental evidence suggests that the inverted voltage gradient is a very likely triggering mechanism for solar array discharges.

Leung, P.↗

The NO(x)-HNO3 System in the Lower Stratosphere: Insights from In Situ Measurements and Implications of the J(HNO3)-[OH] Relationship

During the 1997 Photochemistry of Ozone Loss in the Arctic Region in Summer (POLARIS) mission, simultaneous in situ observations of NOx and HOx radicals, their precursors, and the radiation field were obtained in the lower stratosphere. We use these observations to evaluate the primary mechanisms that control NOx-HNO3 exchange and to understand their control over the partitioning between NO2 and HNO3 in regions of continuous sunlight. We calculate NOx production (PNOx) and loss (LNOx) in a manner directly constrained by the in situ measurements and current rate constant recommendations, using approaches for representing albedo, overhead O3 and [OH] that reduce model uncertainty. We find a consistent discrepancy of 18% between modeled rates of NOx production and loss (LNOx = 1.18P(sub NOx)), which is within the measurement uncertainty of +/- 27%. The partitioning between NOx production processes is [HNO3 + OH (41 +/- 2)%; HNO3 + hv (59 +/- 2)%] and between NOx loss processes is [NO2 + OH, 90% to >97%; BrONO2 + H2O, 10% to <3%]. The steady-state description of NOx-HNO3 exchange reveals the significant influence of the tight correlation between the photolysis rate of HNO3 and [OH] established by in situ measurements throughout the lower stratosphere. Parametrizing this relationship, we find: (1) the steady-state value of [NO2](sub 24h-avg)/[HNO3] in the continuously sunlit, lower stratosphere is a function only of temperature and number density; and (2) the partitioning of NOx production between HNO3 + OH and HNO3 + hv is nearly constant throughout most of the lower stratosphere. We describe a methodology (functions of latitude, day, temperature, and pressure) for accurately predicting the steady-state value of [NO2](sub 24h-avg)/[HNO3] and the partitioning of NOx production within these regions. The results establish a metric to compare observations of [NO2](sub 24h-avg)/[HNO3] within the continuously sunlit region and provide a simple diagnostic for evaluating the accuracy of models that attempt to describe the coupled NOx-HOx photochemistry in the lower stratosphere.

Perkins, K. K.↗

Directional Reflectance Studies in Support of the Radiometric Calibration Test Site (RadCaTS) at Railroad Valley

The Radiometric Calibration Test Site (RadCaTS) is a suite of commercial and custom instruments used to make measurements of the surface reflectance and atmosphere throughout the day at Railroad Valley, Nevada. It was developed in response to the need for daily radiometric calibration data for the vast array of Earth-observing sensors on orbit, which is continuously increasing as more nations and private companies launch individual environmental satellites as well as large constellations. The current suite of instruments at RadCaTS includes five ground-viewing radiometers (GVRs), four of which view the surface in a nadir-viewing configuration. Many sensors such as those on Landsat-7 and Landsat-8 view Railroad Valley within 3° of nadir, while others such as those on Sentinel-2A and -2B, RapidEye, Aqua, Suomi NPP, and Terra can view Railroad Valley at off-nadir angles. Past efforts have shown that the surface bidirectional reflectance distribution function (BRDF) has minimal impact on vicarious calibration uncertainties for views <10°, but the desire to use larger view angles has prompted the effort to develop a BRDF correction for data from RadCaTS. The current work investigates the application of Railroad Valley BRDF data derived from a BRF camera developed at the University of Arizona in the 1990s (but is no longer in use) to the current RadCaTS surface reflectance measurements. Also investigated are early results from directional reflectance studies using a mobile spectro-goniometer system during a round-robin field campaign in 2018. This work describes the preliminary results, the effects on current measurements, and the approach for future measurements.

RadCalNet↗

Absolute measurement of vacuum ultraviolet photon flux in an inductively coupled plasma using a Au thin film

A new method for absolute measurement of the vacuum ultraviolet (VUV) photon flux at the edge of a plasma is described. The light produced by the plasma was allowed to strike a negatively biased, gold-coated copper substrate remote from the plasma. The resulting photoelectron emission current was measured, and the absolute photon flux was then found from the known photoelectron yield of Au. The method was used to quantify the amount of VUV light produced by an Ar/He inductively coupled plasma (ICP). Strong emissions at 104.82 and 106.67 nm, corresponding to the 1s 2 and 1s 4 resonant states of Ar, were observed. The maximum, integrated VUV photon flux measured at the remote location was 3.2 × 10 13 photons/cm 2 s. This was estimated to correspond to a flux of 5 × 10 15 photons/cm 2 s at the edge of the ICP, in the range of reported values under similar conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral Solar Wind Generated by Lunar Exospheric Dust at the Terminator

We calculate the flux of neutral solar wind observed on the lunar surface at the terminator due to solar wind protons penetrating exospheric dust with: (1) grains larger that 0.1 microns and (2) grains larger than 0.01 microns. For grains larger than 0.1 microns, the ratio of the neutral solar wind to solar wind flux is estimated to be approx.10(exp -4)-10(exp -3) at solar wind speeds in excess of 800 km/s, but much lower (less than 10(exp -5) at average to low solar wind speeds. However, when the smaller grain sizes are considered, the ratio of the neutral solar wind flux to solar wind flux is estimated to be greater than or equal to 10(exp -5) at all speeds and at speeds in excess of 700 km/s reaches 10(exp -3)-10(exp -2). These neutral solar wind fluxes are easily measurable with current low energy neutral atom instrumentation. Observations of neutral solar wind from the surface of the Moon could provide a very sensitive determination of the distribution of very small dust grains in the lunar exosphere and would provide data complementary to optical measurements at ultraviolet and visible wavelengths. Furthermore, neutral solar wind, unlike its ionized counterpart, is .not held-off by magnetic anomalies, and may contribute to greater space weathering than expected in certain lunar locations.

Collier, Michael R.↗

Impact of AMS-02 Measurements on Reducing GCR Model Uncertainties

For vehicle design, shield optimization, mission planning, and astronaut risk assessment, the exposure from galactic cosmic rays (GCR) poses a significant and complex problem both in low Earth orbit and in deep space. To address this problem, various computational tools have been developed to quantify the exposure and risk in a wide range of scenarios. Generally, the tool used to describe the ambient GCR environment provides the input into subsequent computational tools and is therefore a critical component of end-to-end procedures. Over the past few years, several researchers have independently and very carefully compared some of the widely used GCR models to more rigorously characterize model differences and quantify uncertainties. All of the GCR models studied rely heavily on calibrating to available near-Earth measurements of GCR particle energy spectra, typically over restricted energy regions and short time periods. In this work, we first review recent sensitivity studies quantifying the ions and energies in the ambient GCR environment of greatest importance to exposure quantities behind shielding. Currently available measurements used to calibrate and validate GCR models are also summarized within this context. It is shown that the AMS-II measurements will fill a critically important gap in the measurement database. The emergence of AMS-II measurements also provides a unique opportunity to validate existing models against measurements that were not used to calibrate free parameters in the empirical descriptions. Discussion is given regarding rigorous approaches to implement the independent validation efforts, followed by recalibration of empirical parameters.

Slaba, T. C.↗

Eddy Current COPV Overwrap and Liner Thickness Measurement System and Data Analysis for 40-Inch Kevlar COPVs SN002 and SN027

As part of the health assessment of flight spare 40in diameter Kevlar composite overwrapped pressure vessels (COPVs) SN002 and SN027 an eddy current characterization of the composite and liner thickness change during pressurization was requested under WSTF-TP-1085-07.A, "Space Shuttle Orbiter Main Propulsion System P/N MC282-0082-0101 S/N 002 and Orbital Maneuvering System P/N MC282-0082-001 S/N 027 COPV Health Assessment." The through the thickness strains have been determined to be an important parameter in the analysis of the reliability and likelihood of stress rupture failure. Eddy current techniques provide a means to measure these thicknesses changes based upon the change in impedance of an eddy current sensor mounted on the exterior of the vessel. Careful probe and technique design have resulted in the capability to independently measure the liner and overwrap thickness changes to better than +/- 0.0005 in. at each sensor location. Descriptions of the inspection system and test results are discussed.

Wincheski, Russell A.↗