Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Fast cycling HTS based superconducting accelerator magnets: Feasibility study and readiness demonstration program driven by neutrino physics and muon collider needs

Development of energy-efficient fast cycling accelerator magnets is critical for the next generation of proton rapid cycling synchrotrons (RCS) for neutrino research and booster accelerators of future muon colliders. We see a unique opportunity for having such magnets to be built on base of High Temperature Superconductors (HTS). Besides being superconducting at relatively high temperatures, rare-earth HTS tapes have shown very small AC losses compared to low-temperature NbTi superconductor cables. Recent tests of the HTS-based 0.5 m long two-bore superconducting accelerator magnet have shown record high dB/dt ramping rates of about 300 T/s at 10 Hz repetition rate and 0.5 T B-field span. No temperature rise in 6 K cooling He was observed within the 0.003 K error setting the upper limit on the cryogenic power loss in the magnet conductor coil to be less than 0.2 W/m. Based on this result we outline a possible upgrade of this test magnet design to 2 T B-field in the 10 mm beam gap with the dB/dt ramping rates up to 1000 T/s. The power test results of this short sample magnet will be used to project both cryogenic and electrical power losses as a function of the magnet B-field and the dB/dt ramping rates. Then these projections will be scaled to the range of expected accelerator magnet beam gaps and B-fields for the proton and muon RCS accelerators. We invite collaborators to join these studies and call for support of the R&D program aimed at comprehensive demonstration of this approach that includes design, construction, and power tests of a long prototype of the HTS-based fast-cycling accelerator magnet by 2028.

43 PARTICLE ACCELERATORS↗

Fiber-optic diagnostic system for future accelerator magnets

The next generation high energy physics accelerators will require magnetic fields at ~20 T. HTS coils will be an essential component of future accelerator magnets and several efforts are currently dedicated on designing 20 T HTS- LTS hybrid magnets. Among the existing challenges, there is the lack of a robust quench detection system for hybrid magnet technology. Another big challenge is represented by the high number of training quenches required by Nb3Sn magnets to reach performance level. In this framework it is important to find a tool that allow local real-time monitoring of magnet strain and temperature. In this paper, we propose the use of fiber optics sensors for diagnostic and quench detection in future accelerator superconducting magnets. Discrete and distributed fiber optic sensors have demonstrated to be a promising tool. The goal is to instrument hundreds of accelerator superconducting magnets and to move beyond the proof-of-concept level. Significant developments are still needed. Here, we are going to present the most recent results and discuss the most urgent technical developments in order to make those sensors a robust and reliable diagnostic tool for accelerator superconducting magnets over the next 10 year. We foresee that discrete fiber sensors will be a stable diagnostic probe for superconducting magnets over the next 3 to 5 years. More R&D work will be necessary for distributed fibers. The most urgent needs are the increase of sample rate and sensitivity. Close collaboration with vendors will be necessary to improve mechanical properties and fabrication processes in order to produce hundreds of meters of fiber and instrument a large number of accelerator superconducting magnets. Those R&D efforts will last up to 10 years with a founding level that spans between 5-10 M$.

43 PARTICLE ACCELERATORS↗

The Transverse Structure of the Deuteron with Drell-Yan

We propose to measure neutron and deuteron transversity TMDs. The quark transversity distributions of the nucleon are decoupled from the deuteron gluon transversity in the $Q^2$ evolution due to the chiral-odd property in the transversely-polarized target. The gluon transversity TMD only exists for targets of spin greater or equal to 1 and does not mix with quark distributions at leading twist, thereby providing a particularly clean probe of gluonic degrees of freedom. This experiment would be the first of its kind and would probe the gluonic structure of the deuteron, investigating exotic glue contributions in the nucleus not associated with individual nucleons. This experiment can be performed with the SpinQuest polarized target recently assembled for experiment E1039 and the spectrometer already in place in NM4. This new experimental setup would require very minimal modification to the target system and no modification to the detector package. An additional RF-circuit and target coil are necessary to RF-modulate across the domain of the Larmor frequency to manipulate the solid-state target spin population densities. Dedicated beam-time with this novel target system is required to achieve our physics goals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

TCR Central Shutdown Rod Fine Motion Control

Transformational Challenge Reactor (TCR) is a Helium cooled 3 MWt test reactor that leverages advances in materials and manufacturing, computing, and AI in its design. Classical design of a shutdown rod uses either gravity, pneumatic, or springs to quickly release the Central Shutdown Rod (CSR) containing neutron absorber into the reactor core stopping nuclear reaction. Generally, the motor/actuator resides outside the reactor, but the motion is transmitted through a penetration into the pressure vessel. There are also designs where the control rod drive incorporates magnetic latches with coil residing outside the pressure boundary for precise position control of the rod. We are proposing a magnetic coupling to position the shutdown rod without any penetration into the pressure vessel for the entire drive length of TCR shutdown rod. Electromagnets are currently used in non-power nuclear reactors for shutdown rods, but these electromagnets are resident inside the reactor pressure vessel. This paper will describe the use of an electromagnet outside the pressure vessel to position and release the shutdown rod. A prototype was developed at ORNL to demonstrate the concept, and a design optimization of the ferritic core and material was conducted to maximize the lift force of the electromagnet. An elevated temperature testing was also performed to ensure that the system will perform under the temperature conditions inside an operating reactor.

Fountain, Eliott J.↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Probe for operando in situ electrochemical nuclear magnetic resonance spectroscopy

Electrochemical devices with metal casings have been considered incompatible with nuclear magnetic resonance (NMR) spectroscopy because the oscillating magnetic fields (“rf fields”) responsible for excitation and detection of NMR active nuclei do not penetrate metals. According to the present invention, rf fields can still efficiently penetrate into nonmetallic layers of electrochemical cells (such as a coin cell battery configuration) provided the magnetic field is oriented tangentially to the electrochemical cell electrodes in a “skimming” orientation. As an example, noninvasive high field in situ 7Li and 19F NMR of an unmodified commercial off-the-shelf rechargeable coin cell was demonstrated using a traditional external NMR coil setup. The in operando NMR measurements revealed that irreversible physical changes accumulate at the anode during electrochemical cycling.

Sorte, Eric Glenn↗

High speed induction machine

In one embodiment, a high speed induction machine includes: a stator formed of a first plurality of laminations having a thickness of less than approximately 0.01 inch and a winding comprising a coil formed of Litz wire adapted about the stator; and a rotor adapted within the stator. The rotor may include: a rotor core formed of a second plurality of laminations having a second thickness of greater than approximately 0.10 inch and formed of high strength steel and sandwiched between a first end region including at least one first peripheral second lamination and a second end region including at least one second peripheral second lamination, the first end region having a first end ring retained by a first retaining ring adapted there around, the second end region having a second end ring retained by a second retaining ring adapted there around.

Karmaker, Haran Chandra↗

Cylindrical microelectrode array for neural stimulation and recording

A cylindrical microelectrode array having an elongated cylindrical core, and a multilayer structure conformally folded around and affixed to the cylindrical core so as to extend between opposite ends of the core. The multilayer structure has integrated sections including an electrode section with electrodes exposed through electrically insulating layers, a connector section with conductive bond pads for interfacing with external electronics, and a cable section with conductive traces encapsulated in electrically insulating layers and which connect between the electrodes and their corresponding bond pads. The array may be fabricated using a planar multilayer structure having the electrode, connector, and cable sections, and conformally folding the multilayer structure around and affixing to the cylindrical core. The cable section in particular may be conformally coiled around and affixed to the cylindrical core so that the electrical conduits helically extend between the connector and electrode sections.

Shah, Kedar G.↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Measurements of Electron Beam-Induced Spin-Relaxation in Frozen-Spin Hydrogen-Deuteride (HD)

Targets of solid hydrogen-deuteride (HD) can be prepared in a frozen-spin state with spin relaxation times (T1) in excess of a year. The present work has studied their potential use in experiments with electron beams. Polarization relaxation rates have been measured during exposure to sub-nanoAmp currents of 9.7 MeV electron beams from the recently commissioned Upgraded Injector Test Facility (UITF) at Jefferson Lab (JLab). These UITF measurements can be used to anticipate the expected performance at the GeV energies typical of JLab experiments, since the energy deposition in a target is almost independent of beam energy. An in-beam dilution refrigerator equipped with superconducting solenoids has been used to maintain solid HD samples at ?0.1 K and ?1 tesla, and internal NMR coils have been used to monitor hydrogen polarization. Spin-relaxation in two frozen-spin targets, with initial H-polarizations of 40% and 34%, have been tracked while exposed to beams under varying conditions of current, dose, beam duty factor and temperature. At a fixed accumulated dose, the spin-relaxation rates drop with current, suggesting depolarization by the charge cloud of the beam. Imposing a duty factor on the otherwise continuous UITF beam, with forced millisecond scale gaps, has shown no obvious correlation to polarization loss rates. After an accumulated dose of ?2 ?C/cm2, beam-off spin-relaxation rates drop from their immeasurably long pre-irradiation values to the order of weeks (with beam-on T1 values typically an order of magnitude shorter), reflecting a buildup of paramagnetic charge centers within the HD lattice. The accumulated polarization loss was approximately proportional to dose in both targets, dropping to 1/e of their initial values after ?6 ?C/cm2. Thermal equilibrium polarizations of targets not in the frozen-spin state (with intentionally short T1) have been used to deduce the in situ temperature of solid HD while under electron bombardment. A model for depolarization by beam-associated paramagnetic impurities largely accounts for the data, and suggests that improvements in heat removal could lead to significant increases in the in-beam T1.

O'Connell, Thomas↗

Pulsed Power Supply for Magnet Quench Training

Superconducting magnets typically go through aseries of spontaneous “training” quenches as their current isincreased towards its design value. To decrease the number ofthese quenches, a device has been designed to boost the magnetcurrent at the moment a quench has been detected and beforemagnet protection has been initiated. The aim of the boost is todrive the magnet coil further along towards its maximum currentwith each training quench, and hence reduce the number ofquenches required.

43 PARTICLE ACCELERATORS↗

Distributed, Intelligent Edge-Sensing for a Smarter Grid

The electric grid is undergoing major transformations and developments resulting in unprecedented levels of volatility, uncertainty, and stress on grid infrastructure. Smart sensors and methods aiding in advanced visibility and situational awareness are key for tackling these issues. In this work, a decentralized architecture is proposed, where sensing, local computation and control capability are embedded in the edge devices, communicating with a set of trusted 'data mules' in a 'delay-tolerant' manner, while functioning autonomously. This system has been designed and implemented as an overall platform – called Global Asset Monitoring, Management and Analytics (GAMMA) Platform intended to provide the backbone for a global array of sensors and actuators. Further, as a building block for advanced current sensing solutions, a smart, low-cost ‘clip-on’ current sensor based on PCB-embedded Rogowski coil has been developed. The sensor hosts a novel signal conditioning stage allowing an 'auto-tuning' feature, resulting in a universal current sensor design for measuring a wide range of currents, including faults for smart grid applications. Finally, the research proposes a method to instrument and monitor key parameters for the most common electric utility asset – the pole-top distribution transformer. The work done in this research enables scalable, edge-intelligent sensing solutions for monitoring grid infrastructure, allowing utility operators to gain advanced visibility in an economical way.

Kulkarni, Shreyas Bhalchandra↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Sensing units including a radio-frequency sensor, and related systems, devices, and methods

Systems, devices, and methods related to generating and/or transmitting sensor measurement data are described. A device may include a first conductive pad positioned on a first surface of a substrate. The device may also include a second conductive pad positioned on a second, opposite surface of the substrate. Further, the device may include an inductive coil coupled between the first electrical pad and the second electrical pad. Also, the device may include a third conductive pad positioned on a third surface of the substrate and configured to couple to a sensor. The device may include a fourth conductive pad positioned on a fourth surface of the substrate and configured to couple to the sensor. The device may be configured to wirelessly transmit a signal.

Smith, James A.↗