Radioactivity induced in sodium iodide by trapped protons.
Radioactivity induced in sodium iodide by trapped protons during OSO-1 passage through lower edge of inner Van Allen zone, presenting gamma-ray counting rates
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Radioactivity induced in sodium iodide by trapped protons during OSO-1 passage through lower edge of inner Van Allen zone, presenting gamma-ray counting rates
Counting rate statistics and energy levels of optical photons in electron photon cascade in cooled mercury atoms
Spatial distribution of energetic electrons in geomagnetic tail by analyzing counting rates from solid state detector on IMP I satellite
Solar modulation of primary cosmic rays deduced from time variations of neutron monitor counting rates and differential rigidity spectra
Mariner 4 cosmic ray observations in 1964-1965, discussing low and high energy electron detectors and daily averages of counting rates
Effects of water concentration on neutron counting rate of lunar simulator
M-87 X ray luminosity from balloon-borne detectors, considering background counting rate relation to azimuth
Counting efficiency, noise factor measurement, dark noise, gain and counting rate, optical enhancement
Cosmic gamma rays observation by balloon flight and satellite with scintillation detector, tabulating counting rates in pulse height channels relative to Crab Nebula
Conversion factor for converting Geiger tube count rates or ion chamber currents into units of incident X ray energy flux in specified passband in normalizing solar X ray data
Proton, helium, and medium nuclei energy spectra have been measured from the Explorer 35 satellite for a recent solar flare. Above 2 MeV/nucleon these spectra are based upon single and dual parameter pulse height analysis in addition to threshold rate counting. Pulse height analysis of medium nuclei is assigned a high priority for telemetry readout so that telemetry does not become saturated by the high proton intensity. In this manner the number of pulse height analyzed medium nuclei has been increased by a factor of approximately 200. Individual medium nuclei have been resolved in the energy interval 8 - 23 MeV/nucleon.
A higher than normal ratio is reported for the decrease of cosmic ray intensity on 18 December 1965. This value was attributed to the depletion of a low rigidity electron component which also contributes to the counting rate of the IMP 3 detector. Significant difference is observed in the onset times recorded by the IMP 3 detector and Alert neutron monitor.
A Compton scatter attenuation gamma ray spectrometer conceptual design is discussed for performing gamma spectral measurements in monodirectional gamma fields from 100 R per hour to 1,000,000 R per hour. Selectable Compton targets are used to scatter gamma photons onto an otherwise heavily shielded detector with changeable scattering efficiencies such that the count rate is maintained between 500 and 10,000 per second. Use of two sum-Compton coincident detectors, one for energies up to 1.5 MeV and the other for 600 keV to 10 MeV, will allow good peak to tail pulse height ratios to be obtained over the entire spectrum and reduces the neutron recoil background rate.
A neutron detector sensitive from 2 to 100 MeV is described. The detector is designed for high altitude balloon flight to measure the flux, energy and direction of albedo neutrons from the earth and to search for solar neutrons. A neutron scatter from a proton is required in each of two liquid scintillator tanks spaced 1 meter apart. The energy of the recoil proton in the first tank is obtained from pulse height analysis of the scintillator output. The energy of the recoil neutron is obtained from its time of flight between the tanks. The detector has been calibrated with 15.3 MeV neutrons and mu mesons. The minimum detectable flux is 10(-4) neutron/sq cm/sec at a counting rate of one per minute; the energy resolution is 12% at 15 MeV and 30% at 100 MeV. The angle between the incoming neutron and the recoil neutron is measured to + or - 10 deg.
Design studies for an X-ray experiment to investigate planetary magnetospheres using solid state detectors, or proportional counters are reported. The detectors, background counting rate, and leakage fluxes are discussed. It is concluded that the best choice of instruments appears to be two separate multiproportional counters for redundancy.
Design studies for an X-ray experiment using solid state detectors and for an experiment using a proportional counter for investigating Jovian and Saturnian magnetospheres are reported. Background counting rates through the forward aperture and leakage fluxes are discussed for each design. It is concluded that the best choice of instrument appears to have following the characteristics: (1) two separate multiwire proportional counters for redundancy; (2) passive collimation to restrict the field to about 5 deg, wiregrid modulation collimation to about 0.1 deg angular resolution; (3) no active shielding system around the counter body; and (4) light passive shielding around any portion of the counter body exposed to space to absorb most of the cosmic X-ray background.
The initial results of absolute proton efficiency measurements made in an auroral particle study by sounding rockets are given. The measurements were made at several counting rates from 1000 to 40,000 counts/sec on rocket-borne equipment. The results agree with those of Egidi et al. (1969) in the high energy range and show a disagreement at low energies.
Laboratory measurements have been made of the response of two typical cosmic ray detector systems to electrons between 0.2 and 2.0 MeV. Working laboratory versions of each of these particle telescopes were exposed to the monoenergetic electron beam from a magnetic spectrometer. The results of pulse height and counting rate measurements indicate that electrons scattered from the anticoincidence cup comprise about 25% of the total number arriving at the top of the detector stack. In certain cases, the contribution of these scattered particles to the total number of electrons detected can reach 65%.