Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMMERCIALIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Innovative Commercialization Efforts Underway at the National Renewable Energy Laboratory

New clean energy and energy efficiency technology solutions hold the promise of significant reductions in energy consumption. However, proven barriers for these technologies, including the technological and commercialization valleys of death, result in promising technologies falling to the wayside. To address these gaps, NREL's Innovation & Entrepreneurship Center designs and manages advanced programs aimed at supporting the development and commercialization of early stage clean energy technologies with the goal of accelerating new technologies to market. These include: Innovation Incubator (IN2) in partnership with Wells Fargo: this technology incubator supports energy efficiency building-related startups to overcome market gaps by providing access to technical support at NREL; Small Business Voucher Pilot: this program offers paid vouchers for applicants to access a unique skill, capability, or facility at any of the 17 DOE National Laboratories to bring next-generation clean energy technologies to market; Energy Innovation Portal: NREL designed and developed the Energy Innovation Portal, providing access to EERE focused intellectual property available for licensing from all of the DOE National Laboratories; Lab-Corps: Lab-Corps aims to better train and empower national lab researchers to understand market drivers and successfully transition their discoveries into high-impact, real world technologies in the private sector; Incubatenergy Network: the Network provides nationwide coordination of clean energy business incubators, share best practices, support clean energy entrepreneurs, and help facilitate a smoother transition to a more sustainable clean energy economy; Industry Growth Forum: the Forum is the perfect venue for clean energy innovators to maximize their exposure to receptive capital and strategic partners. Since 2003, presenting companies have collectively raised more than $5 billion in growth financing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Study of IR Loss Correction Methodologies for Commercially Available Pyranometers

This presentation provides a high-level overview of a study of IR Loss Connection Methodologies for Commercially Available Pyranometers. The IR Loss Corrections Study is investigating how various correction methodologies work for several makes and models of commercially available pyranometers in common use, both when operated in ventilators with DC fans and without ventilators, as when they are typically calibrated.

14 SOLAR ENERGY↗

Field Experience with and Potential for Multi-time Scale Grid Transactions from Responsive Commercial Buildings

The need for and concepts behind demand response are evolving. As the electric system changes with more intermittent renewable electric supply systems, there is a need to allow buildings to provide more flexible demand. This paper presents results from field studies and pilots, as well as engineering estimates of the potential capabilities of fast load responsiveness in commercial buildings. We present a sector wide analysis of flexible loads in commercial buildings, which was conducted to improve resource planning and determine which loads to evaluate in future demonstrations. These systems provide important capabilities for future transactional systems. The field analysis is based on results from California, plus projects in the northwest and east coast. End-uses considered include heating, ventilation, air conditioning and lighting. The timescales of control include day-ahead, as well as day-of, 10-minute ahead and even faster response. This technology can provide DR signals on different times scales to interact with responsive building loads. We describe the latency of the control systems in the building and the round trip communications with the wholesale grid operators.

Piette, Mary Ann↗

Making Commercial Whole Building Program Delivery Easier and Less Risky Greg Thomas, Performance Systems Development

Whole building commercial programs can be challenging to deliver due to their complexity and scope. A broad suite of Federal tools and reference standards can be leveraged to reduce program cost and risk, and improve scalability. The OpenEfficiency Initiative (OEI) is a DoE funded effort to expand the deployment of Federal tools and reference standards into whole building commercial efficiency programs. OEI is developing an open source data exchange platform which is being informed and motivated by pilots.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Roadmap Toward a Predictive Performance-based Commercial Energy Code

Energy codes have provided significant increases in building efficiency over the last 38 years, since the first national energy model code was published in late 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. The current focus on prescriptive codes has limitations including significant variation in actual energy performance depending on which prescriptive options are chosen, a lack of flexibility for designers and developers, and the inability to handle control optimization that is specific to building type and use. This paper provides a high level review of different options for energy codes, including prescriptive, prescriptive packages, EUI Target, outcome-based, and predictive performance approaches. This paper also explores a next generation commercial energy code approach that places a greater emphasis on performance-based criteria. A vision is outlined to serve as a roadmap for future commercial code development. That vision is based on code development being led by a specific approach to predictive energy performance combined with building specific prescriptive packages that are designed to be both cost-effective and to achieve a desired level of performance. Compliance with this new approach can be achieved by either meeting the performance target as demonstrated by whole building energy modeling, or by choosing one of the prescriptive packages.

Rosenberg, Michael I.↗

Understanding Occupancy Patterns in a Commercial Space

Heating, ventilation, and air conditioning (HVAC) is a prime source of energy consumption in the US. In 2006, approximately 35% of energy in the US was used for HVAC [1]. Usually building operators use a static schedule for controlling HVAC systems without having a deeper understanding of how many people use the building at different times of the day. In addition, HVAC systems operate by assuming maximum occupancy in each room, which leads to a significant energy waste, e.g., an HVAC system providing ventilation for 30 people when there are only 10 people in a room. Considering how many people use different rooms at different times of the day is very crucial for achieving building energy efficiency and providing occupant comfort. There have been several attempts to collect long term occupancy patterns from office buildings, e.g., Mitsubishi’s Electronic Research Lab (MERL) dataset [14] and Colorado School of Mines (CSMBB) dataset. However, PIR motion detectors are used in these projects for sensing occupancy and hence these datasets only reflect whether a room is occupied or not without revealing the actual person count. Similar datasets are also collected from households. Only a few datasets from commercial spaces capture actual person count, and even in these cases, the data collection period was very limited, e.g., in [3] only 5 days of occupancy data is collected as ground truth. We are the first to collect long term (9 months) occupancy data (people count) from an 11,000 square foot commercial office (second floor of Bosch Research and Technology Center Pittsburgh). In this paper, we outline some statistical results from our empirical study and explore their implications for saving energy.

42 ENGINEERING↗

NIST Infiltration Tools for Commercial Buildings

The Department of Energy estimates that infiltration through building envelopes accounted for 6 % of the total energy consumed by commercial buildings and 21 % of the heating and cooling energy. Air barrier requirements are now being included in ASHRAE Standards 90.1 and 189.1 and other construction requirements. The energy impacts of unintended infiltration on building energy use can be significant, but current energy simulation software and design methods are generally not able to accurately account for envelope infiltration and the impacts of improved airtightness. NIST has been developing tools to better account for infiltration in building energy models. The tools that will be discussed in this paper include: CONTAM Results Export Tool; weather-correlated infiltration inputs for prototype commercial buildings and the associated Open Studio Measures; and a web-based tool to evaluate the energy savings of building envelope airtightening, which was developed with the Oak Ridge National Laboratory and the Air Barrier Association of America. This paper briefly describes each tool, their applications, and the benefits of using each. All of the tools are publicly available at no cost.

Ng, Lisa↗

A Preliminary Investigation on the Cost Reduction Potential of Optimizing Bore Fields for Commercial Ground Source Heat Pump Systems

The high initial cost of ground heat exchangers (GHE) is a primary hurdle preventing wider adoption of ground source heat pump (GSHP) systems. GHEs used for commercial GSHP systems commonly consist of vertical boreholes installed on a grid with equal spacing between boreholes. Significant thermal loads require a large number of boreholes to be present in the field. However, due to thermal interactions among boreholes, the ground formation in the center of a bore field can, over time, become thermally saturated when the thermal load is not balanced on an annual basis. The loss of effectiveness due to thermal saturation at the center boreholes in regularly spaced borehole fields suggests that larger spacing near the center of the bore field could be more optimal, and in return reduce initial costs. Through computer simulations using the latest development of a GHE modeling tool, this study evaluates the impacts of various unconventional designs of the borehole field on the performance and cost of the GHEs of a typical commercial GSHP system. The unconventional designs include irregular spacing among boreholes with decreased spacing around the perimeter and increased spacing in the interior of the field. The unconventional bore field design shortens the total drilling length by up to 42% while giving better heat transfer performance than a conventional bore field design. The significant total bore length reduction is due to improved heat transfer effectiveness of each borehole in the unconventional bore field.

Spitler, Jeffery↗

Peak Power Reduction for HVAC Operations in Multi-unit Commercial Buildings

The load profiles of most commercial consumers are characterized by brief periods of very high power consumption followed by intervals of relatively lower demand. In order to flatten commercial load profiles, several power utilities in addition to billing energy consumption, levy a demand charge (DC) on the monthly peak demand. In this work, we consider the problem of joint optimization of energy costs (EC) and DC incurred by a multi-unit building which follows a demand response (DR) program. Despite the non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using linear programming. We evaluate the performance of the proposed power control scheme for various climate zones in the US. We show that depending on the ambient conditions and the prescribed tariff structure, our strategy can result in savings of up to nearly 19% compared to the baseline.

Raza Naqvi, Syed A.↗

Predicting and Managing Risk to Bats at Commercial Wind Farms using Acoustics

Bat populations in North America face novel threats from white-nose syndrome and widespread turbine-related mortality related to the rapidly expanding wind power industry in addition to long-standing pressures from habitat loss and degradation. Bats, unlike most small mammals, are long-lived and slow to reproduce, highlighting the importance of understanding and managing anthropogenic sources of mortality. My dissertation research used acoustic bat detectors to measure bat activity at commercial wind projects, predict patterns in risk, and design strategic measures to reduce fatality rates by curtailing turbine operation during periods when bats are most active. Bats collide with wind turbines only when their rotors are spinning, and risk of turbine-related fatality is therefore a dynamic factor that can be manipulated by curtailing turbine operation when bats are active. We first measured inter-detector variation in metrics of acoustic bat activity to understand how the acoustic detection process may affect inferences related to spatial and temporal variation in bat activity. Using acoustic detectors mounted on top of wind turbines at two commercial wind farms in West Virginia, we then demonstrated that the amount of bat activity recorded when turbines were operating aligned closely with bat fatality rates on multiple scales. Accordingly, the metric of bat activity exposed to turbine operation provides a meaningful, quantitative indicator of turbine-related bat fatality risk. Further, bats responded consistently to changing wind speed and temperature at turbines in both wind farms across multiple years, enabling exposed bat activity to be predicted accurately among turbines and years. Building on these results, we simulated exposure of bats to turbine operation and energy loss for curtailment strategies recommended by state and federal agencies in the United States and Canada. By adjusting parameters such as cut-in wind speeds and temperature thresholds, we demonstrated the ability to design strategic curtailment programs that achieve equivalent or greater predicted reductions in bat activity exposure for substantially less energy-production loss. Characterizing fatality risk on a finer scale using acoustics will help regulatory agencies and the wind industry alike reduce risks of population-level impacts to vulnerable bat species while continuing to expand large-scale renewable energy generation.

17 WIND ENERGY↗

Using Wi-Fi Location-Based Services (LBS) for Commercial Building Occupancy Sensing

From May 2019 through October 2022, this DOE-funded project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at two commercial buildings located in Minnesota and Wisconsin.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons Learned Converting A Commercial Enclosure to a Uranium Handling Glovebox

This presentation highlights the conversion of a commercial Directed Energy Deposistion machine to a radiological glovebox. An overview of some of the advanced manufacturing capabilities at INL is outlined along with some definitions and facts of additive manufacturing. The upgrades to the commercially purchased Optomec LENS MR-7 and the difficulties with qualifying it as a radiological glovebox are presented.

3-D Printing↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock: Commercial Building Stock Energy Consumption Dataset

The commercial building sector stock model, or ComStock, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States.

building↗

Integrated Systems Analysis for a Regional Deep Borehole Repository for Commercial Spent Nuclear Fuel - 16291

Some nuclear waste stakeholders have suggested private interim storage facilities (ISF), but little work has been done to consider the cost or logistics for nuclear waste management or disposal facilities smaller than the national scale. This paper performs an integrated system analysis for a deep borehole repository system which would accept waste from a regional subset of the national commercial reactor fleet. The regional subset is comprised of a centrally-located host state with a large SNF inventory surrounded by states with small SNF inventories. The chosen region will contain between one-fifth and one-quarter of the national commercial SNF inventory. Using best estimates of past and future SNF discharges in the sample region, the SNF inventory in the chosen region is characterized by reactor of origin. Basic parameters are then chosen for the regional repository, such as the annual rate of waste emplacement and the time necessary to process borehole-specific waste canisters. Scenarios chosen for analysis test the sensitivity of a variety of system parameters, including the annual rate of waste acceptance, the division of annual waste acceptance among sites, the use of bare fuel transportation canisters, and the size of the regional subset of reactors. Estimated costs for the facility are $13 billion for around 27,000 MT of SNF and $16 billion for around 35,000 MT. This translates to $490,000 per MT and $466,000 per MT, respectively. These unit costs are comparable to the $370,000 per MT estimate for the full 140,000 MT national inventory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Colonie FUSRAP Site - Radioactive Dust Sampling of Residential and Commercial Properties - 16384

The Colonie Formerly Utilized Sites Remedial Action Program (FUSRAP) Site is located in the Town of Colonie, Albany County, New York. The U.S. Army Corps of Engineers (USACE) is currently addressing environmental contamination associated with the Site. The area surrounding the Site consists of residential and commercial properties, known as vicinity properties (VPs). Cleanup activities have been completed on many of these VPs under the FUSRAP to address depleted uranium contamination. Soil remediation activities have been substantially completed at the Colonie FUSRAP Site and its VPs under the FUSRAP. Recent studies performed by an independent party and under FUSRAP identified uranium within indoor dust in residencies and businesses in the immediate vicinity of the Site. The studies were limited to non-living areas such as basement window sills, garages, and attics. This paper discusses the indoor dust sampling and analysis, in support of the Remedial Investigation (RI) for the VPs, and presents sampling results. The indoor dust sample media presented many technical challenges regarding sampling design, data reduction, and data interpretation. In addition, because the RI is focused on numerous resident-owned, rental, and commercial properties, challenges where presented regarding right-of-entry to sample. Isotopic uranium ratios observed in the majority of the samples are indicative of the depleted uranium contaminant, even at trace levels. While the sampling and analysis methods were effective at identifying depleted uranium in the majority of the samples, preliminary property-specific risk assessment results do not indicate the presence of depleted uranium in sufficient concentrations to pose unacceptable risk to VP inhabitants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remediation of Occupied Commercial Property Subject to Widespread Radium-226 Contamination: Update from WM2012 Paper - 16652

Amec Foster Wheeler was contacted by a company that managed commercial office space. High Rn-222 measurements had been observed throughout the facility and the landlord had been advised to commission a radiological survey of the site. The site had been purchased by the client in the 1990's. Initial desk studies found that the building had operated for around 50 years as a compass factory. Non-intrusive investigation identified widespread Ra-226 contamination. Ra-226 was found in the fabric of the building, in attic spaces, buried under floor boards and underlying car parks. Intrusive investigation was undertaken to estimate volume(s) of waste, waste categories, activity concentrations and the total inventory of radioactive materials on site. This work identified the presence of 180 GBq of Ra-226 on site. A programme of work is currently underway to remediate the site tackling areas posing the greatest risk to site occupants as a priority. We have worked closely with Regulators, our client, and tenants, to decontaminate the fabric of the building whilst areas of the building remain occupied. Early decontamination works identified that radon levels within the building were stubbornly high despite the removal of radium contamination. An independent radon source was suspected. A contaminated drain was discovered leading to a blocked-off river race running under the old mill building. A significant quantity of radium contaminated sludge was identified within the river race. This was believed to be the source of the excessive radon concentrations within the building. The paper will present work undertaken to investigate and remediate the inventory of sludge from beneath the building. It will describe the operational difficulties of working within a dynamic environment impacted by high dose rates, high radon concentrations, water ingress and waste retrieval challenges. The paper will present the radiological and environmental impacts of the work and detail the achieved end points. This was a challenging project working in confined spaces impacted by physical and radiological constraints. The remedial action undertaken significantly reduced radon concentrations in the building metres above the river race. It also significantly reduced the likelihood of radium contamination being mobilised into the river and the wider environment. The achieved end point permitted the building to return to uncontrolled commercial use. The end point achieved within the river race will ensure a safe working environment for future regular structural survey work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adaptation of Commercially Available Robots for Conditioning and Packaging ILW at Sellafield - 18282

The Legacy Ponds and Silos at Sellafield site contain some of the most hazardous Intermediate Level Waste (ILW) in the UK. As part of a multi-billion pound decommissioning programme, this waste will be retrieved and transported across the site for conditioning and packaging in the Box Encapsulation Plant (BEP). Current plans are to commence plant active commissioning in 2022, which will represent a major milestone in the UK nuclear decommissioning programme. Within the plant, skips of waste will be transferred from the shielded transport package into standard 3 cubic metre ILW containers. Waste from the Pile Fuel Storage Pond and First Generation Magnox Storage Pond will be immobilised in cementitious grout before being transferred to an adjacent store. Waste from the Magnox Swarf Storage Silo will not be immobilised in grout, but will be packaged, providing multi-barrier containment. During the concept design, the project team selected commercially available robots as the most viable technology for carrying out the numerous dexterous and repetitive tasks involved in characterising, conditioning and packaging the waste within the shielded 'hot' cells. Significant technical challenges had to be overcome during the design to adapt a commercially available robot for use within a high radiation / high contamination environment, where human access is not safe even for short periods of time. These challenges included: - Designing robot assemblies that could be retrofitted into the existing cell structure that was constructed as part of an earlier project but never completed; - Designing robot assemblies that could be recovered to their 'transport' position without requiring manual intervention; - Designing robot assemblies that could be remotely removed and replaced with new ones if they failed part way through the plant operational life; - Designing through-wall service and power connections that allow maintenance and recovery; - Designing control systems and human-machine interfaces that enable both manual and automated operation of the robot, whilst avoiding collisions with the in-cell cranes and other in cell furniture; - Assessing the radiation tolerance of all items. Bespoke computer simulations and full-scale development trials have been carried out, using non-active test materials, in order to demonstrate the Technology Readiness Level (TRL) required by Sellafield Limited (SL) at each stage of the project [1]. The results of these trials have been recorded in both video and written form so that they can form part of the project's Knowledge Management database. Detailed designs and specifications for the robot assemblies have been updated to incorporate the recommendations from the development trials. Procurement and manufacture of robot assemblies has already commenced to deliver two waste handling robots, two waste container lidding / swabbing robots and associated critical spares. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗