Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMMERCIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Transonic Cruise Slotted Wing Design for Commercial Transport Aircraft using CDISC

A knowledge-based aerodynamic design method, CDISC, has been extended to enable the computational design of transonic cruise slotted wings for commercial transport aircraft. The cruise slotted wing is a multielement wing concept with a forward main element and an aft flap element, separated to form an intermediate slot. This slot favorably redirects airflow from the main element lower surface toward the low-momentum, upper-surface boundary layer of the flap. Relative to the supercritical wing, the cruise slotted wing enables greater aft loading that helps to reduce shock strength and transonic pressure drag. The cruise slotted wing may be considered a passive drag-reduction technology with potential fuel burn savings and increased vehicle range for next-generation aircraft. The current paper seeks to quantify the drag-saving benefits of cruise slotted wing technology in application to single-aisle commercial transport aircraft. A series of multielement design constraints were developed within CDISC for the design of a partial-span, cruise slotted wing for a Mach-0.8 variant of the Common Research Model. To mitigate the skin-friction drag penalty associated with cruise slotted wings, the design features a flap with natural laminar flow over approximately 75% of the flap surface area. Cruise drag estimates from the NASA USM3D flow solver between a supercritical wing and the partial-span, cruise slotted wing design were within one drag count. Near-cruise, off-design analyses showed limited laminar flow sensitivity to angle of attack and a more gradual drag rise compared to a supercritical wing. Based on this demonstrated benefit, future work is motivated to design a cruise slotted wing with natural laminar flow on both wing elements to achieve a significant reduction in cruise drag while providing delayed drag divergence.

CDISC↗

Enabling Model Organism and Commercial Astronaut Data Access Through the NASA Open Science Data Repository

NASA’s Open Science Data Repository (OSDR) brings together omics data from NASA’s GeneLab project and non-omics data, including physiological, phenotypic, imaging, and behavioral data from NASA’s Ames Life Sciences Data Archive (ALSDA) collected from decades of space biology research, providing open and FAIR (findable, accessible, interoperable, and reusable) access of these precious data to scientists world-wide. This rich source of meticulously curated metadata and data from spaceflight and analog studies has been mined by the scientific community resulting in dozens of high impact scientific publications that reveals a complex network of molecular and physiological effects of spaceflight across living systems, from microbes to plants, to mammals. Understanding how these effects translate to the human condition is critical as we move deeper into the era of commercial space travel. However, the integration of data, specifically omics data, from astronauts is particularly challenging due to their sensitive nature. OSDR has risen to this challenge by developing a mechanism to control access to identifiable levels of omics data, such as raw sequence data, while enabling public access to processed, unidentifiable, data and associated metadata that will allow the scientific community to interrogate human astronaut data alongside data from model organisms to begin answering these critical questions. The 2021 SpaceX Inspiration4 (I4) mission collected a comprehensive atlas of biological measurements from four civilian astronauts, providing a wealth of data to characterize the effects of spaceflight on the human body. These data include both non-omics and omics assays such as direct RNA sequencing (RNA-seq), single nuclei ATAC-seq and RNA-seq, metagenomics, proteomics, and comprehensive metabolic and cytokine panels, all of which have been integrated into the OSDR system across no less than 9 studies. Each study has been carefully curated using community-backed OSDR standards for sample and assay level metadata ensuring these data are findable and accessible. In addition to hosting both raw and processed data from the principal investigator team for each assay type, the GeneLab team plans to re-process the I4 omics data using GeneLab’s standard processing pipelines. The GeneLab processed data outputs will allow for comparisons across studies on OSDR and enable visualization of these data through the OSDR data visualization platform thereby enabling data reusability and interoperability. Here we describe the robust privacy and security protocols implemented by OSDR to safeguard sensitive health data from astronauts while facilitating metadata and processed data sharing for research purposes. We further provide a road map for navigating the vast amount of data provided for each I4 study on the OSDR, including experimental design, associated experiments, payloads, and missions, data generation and analysis protocols, and associated scientific articles. Additionally, we illustrate how to interrogate the standardized metadata provided in the sample and assay tables as well as instructions for how to download and access the data. The I4 datasets described here re present the first ever comprehensive collection of commercial astronaut data.

Amanda M Saravia-Butler↗

Assessment of High Resolution Commercial Satellite Geolocation Accuracy

Commercial companies such as Maxar, PlanetScope, and BlackSky have launched many satellites with revisit times ranging from two hours to one day and have built large archives of high resolution (1-3 m) Earth observing data. The high temporal resolution and global coverage of these satellites makes commercial satellite images ideal for scientists studying rapidly changing processes such as flooding and fires. A key step in assessing changes in these images is co-registration of various images to each other. High geolocation accuracy (at most 0.5 pixels of offset) allows for easy co-registration of images across different times and sensors. Here, we assess the latest PlanetScope imagery and evaluate it for geolocation accuracy. For our assessment, we compare the target image to a reference image with known geolocation accuracy (WorldView imagery) and determine the offset between these images by shifting them to maximize their Pearson Cross-Correlation (PCC) value. Offsets required to maximize the PCC give the geolocation accuracy of the target image relative to the reference image. Previously, our global assessment of Planet data revealed large variability in geolocation accuracy from one continent to another. The measured root mean squared errors (RMSEs) range from 5.4 m in North America to 14.9 m in Africa. We have updated this previous assessment to include both their newest SuperDove series as well as a more robust assessment of the temporal stability of PlanetScope's geolocation accuracy.

Alana G. Semple↗

Observations on Space Flight Program and Project Commercial Partnerships and NASA Tailored Program Management Approaches

This document provides information for new programs and projects considering the use of a commercially oriented partnership acquisition approach. The information is based on two programs that have implemented commercial partnerships; distills observations from these acquisition experiences; and the associated application of a tailored program/project management approach.

Ellen R Stigberg↗

The Status of NASA SCaN's Efforts to Integrate Commercial Satellite Communication Service Providers Into the Near Space Network

The National Aeronautics and Space Administration’s (NASA) Space Communication and Navigation (SCaN) program intends to deliver operationally ready commercial space-based communications relay services to missions by 2031. The high-throughput, demand-responsive networks that commercial providers are building and operating will remove long-standing network constraints, enhancing mission capability and data-return.

Near Space Network↗

Commercial Synthetic Aperture Radar Data for Surface Deformation and Change

The commercial synthetic aperture radar (SAR) market is experiencing year-over-year growth and is currently capable of imaging anywhere in the world within an hour at X-band. Surface Deformation and Change (SDC) is a mission study at NASA to investigate innovative architectures beyond the NASA-ISRO SAR (NISAR) mission in the next decade. In this article we present preliminary findings on the technical capabilities of the currently available commercial SAR data, and investigate their applicability to SDC goals, such as imaging quality and retrieval of surface motion.

SAR↗

An Evaluation of the Environmental Impact of Different Commercial Supermarket Refrigeration Systems Using Low Global Warming Potential Refrigerants

Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system s Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCP of different air-conditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.

LCCP↗

Roadmap Toward a Predictive Performance-based Commercial Energy Code

Energy codes have provided significant increases in building efficiency over the last 38 years, since the first national energy model code was published in late 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. The current focus on prescriptive codes has limitations including significant variation in actual energy performance depending on which prescriptive options are chosen, a lack of flexibility for designers and developers, and the inability to handle control optimization that is specific to building type and use. This paper provides a high level review of different options for energy codes, including prescriptive, prescriptive packages, EUI Target, outcome-based, and predictive performance approaches. This paper also explores a next generation commercial energy code approach that places a greater emphasis on performance-based criteria. A vision is outlined to serve as a roadmap for future commercial code development. That vision is based on code development being led by a specific approach to predictive energy performance combined with building specific prescriptive packages that are designed to be both cost-effective and to achieve a desired level of performance. Compliance with this new approach can be achieved by either meeting the performance target as demonstrated by whole building energy modeling, or by choosing one of the prescriptive packages.

Rosenberg, Michael I.↗

COMMERCIALIZATION OF AN ATMOSPHERIC IRON-BASED CDCL PROCESS FOR POWER PRODUCTION. PHASE I: TECHNOECONOMIC ANALYSIS

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has potential to enable substantial reductions in the cost and energy penalty associated with carbon dioxide (CO2) capture from coal-fired power plants. Through collaborative efforts, the Babcock & Wilcox Power Generation Group (B&W) and The Ohio State University (OSU) developed a conceptual design for a 550 MWe (net) supercritical CDCL power plant with greater than 90% CO2 capture and compression. Process simulations were completed to enable an initial assessment of its technical performance. A cost estimate was developed following DOE’s guidelines as outlined in NETL’s report “Quality Guidelines for Energy System Studies: Cost Estimation Methodology for NETL Assessments of Power Plant Performance”, (2011/1455). The cost of electricity for the CDCL plant without CO2 Transportation and Storage cost resulted in $ $102.67 per MWh, which corresponds to a 26.8 % increase in cost of electricity (COE) when compared to an air-fired pulverized-coal supercritical power plant. The cost of electricity is strongly depending on the total plant cost and cost of the oxygen carrier particles. The CDCL process could capture further potential savings by increasing the performance of the particles and reducing the plant size. During the techno-economic analysis, the team identified technology and engineering gaps that need to be closed to bring the technology to commercialization. The technology gaps were focused in five critical areas: (i) moving bed reducer reactor, (ii) fluidized bed combustor, (iii) particle riser, (iv) oxygen-carrier particle properties, and (v) process operation. The key technology gaps are related to particle performance, particle manufacturing cost, and the operation of the reducer reactor. These technology gaps are to be addressed during Phase II of project. The project team is proposing additional lab testing to be completed on the particle and a 3MWth pilot facility be built to evaluate the reducer reactor performance among other aspects of the technology. A Phase II proposal was prepared and submitted to DOE. The project team proposed a three year program in Phase II. Year 1 includes lab testing and particle development work aimed at improving the chemical and mechanical properties of the oxygen carrier particle. In parallel, B&W will design the 3MWt pilot plant. Any improvements to the particle performance discovered in year 1 that would impact the design of the pilot will be incorporated into the final design. Year 2 will focus on procurement of materials and equipment, and construction of the pilot plant. Year 3 will include, commissioning, start-up, and testing in the pilot. Phase I work was successfully completed and a design and operating philosophy for a 550 MWe commercial scale coal-direct chemical looping power plant was developed. Based on the results of the techno-economic evaluation, B&W projects that the CDCL process can achieve 96.5% CO2 capture with a

Coal Combustion↗

Field Experience with and Potential for Multi-time Scale Grid Transactions from Responsive Commercial Buildings

The need for and concepts behind demand response are evolving. As the electric system changes with more intermittent renewable electric supply systems, there is a need to allow buildings to provide more flexible demand. This paper presents results from field studies and pilots, as well as engineering estimates of the potential capabilities of fast load responsiveness in commercial buildings. We present a sector wide analysis of flexible loads in commercial buildings, which was conducted to improve resource planning and determine which loads to evaluate in future demonstrations. These systems provide important capabilities for future transactional systems. The field analysis is based on results from California, plus projects in the northwest and east coast. End-uses considered include heating, ventilation, air conditioning and lighting. The timescales of control include day-ahead, as well as day-of, 10-minute ahead and even faster response. This technology can provide DR signals on different times scales to interact with responsive building loads. We describe the latency of the control systems in the building and the round trip communications with the wholesale grid operators.

Piette, Mary Ann↗

Assessing Energy Efficiency Opportunities in US Industrial and Commercial Building Motor Systems

In 2002, the United States Department of Energy (USDOE) published an energy efficiency assessment of U.S. industrial sector motor systems titled United States Industrial Electric Motor Systems Market Opportunities Assessment. The assessment advanced motor system efficiency by providing a greater understanding of the energy consumption, use characteristics, and energy efficiency improvement potential of industrial sector motor systems in the U.S. Since 2002, regulations such as Minimum Energy Performance Standards, cost reductions for motor system components such as variable frequency drives, system-integrated motor-driven equipment, and awareness programs for motor system energy efficiency have changed the landscape of U.S. motor system energy consumption. To capture the new landscape, the USDOE has initiated a three-year Motor System Market Assessment (MSMA), led by Lawrence Berkeley National Laboratory (LBNL). The MSMA will assess the energy consumption, operational and maintenance characteristics, and efficiency improvement opportunity of U.S. industrial sector and commercial building motor systems. As part of the MSMA, a significant effort is currently underway to conduct field assessments of motor systems from a sample of facilities representative of U.S. commercial and industrial motor system energy consumption. The Field Assessment Plan used for these assessments builds on recent LBNL research presented at EEMODS 2011 and EEMODS 2013 using methods for characterizing and determining regional motor system energy efficiency opportunities. This paper provides an update on the development and progress of the MSMA, focusing on the Field Assessment Plan and the framework for assessing the global supply chain for emerging motors and drive technologies.

Rao, Prakash↗

SUPERVISORY CONTROL FOR PEAK REDUCTION IN COMMERCIAL BUILDINGS WHILE MAINTAINING COMFORT

This paper describes a supervisory control strategy for limiting peak power demand by small and medium commercial buildings while still meeting the business needs of the occupants. This control strategy has two features that make it relevant to new and existing buildings. First, it is designed to operate with building equipment, such as air conditioning and refrigeration systems, as they are presently installed in most small and medium commercial buildings. Because of this, the supervisory control could be realized as a software-only retrofit to existing building management systems. Second, the proposed control acts as a supervisory management layer over existing control systems, rather than replacing them outright. The primary idea of this approach is that the controls for individual building equipment request energy resources for a control action and the supervisory control examines the requests and decides which control actions to allow while satisfying a limit on peak power demand.

Nutaro, James J↗

Innovative Commercialization Efforts Underway at the National Renewable Energy Laboratory

New clean energy and energy efficiency technology solutions hold the promise of significant reductions in energy consumption. However, proven barriers for these technologies, including the technological and commercialization valleys of death, result in promising technologies falling to the wayside. To address these gaps, NREL's Innovation & Entrepreneurship Center designs and manages advanced programs aimed at supporting the development and commercialization of early stage clean energy technologies with the goal of accelerating new technologies to market. These include: Innovation Incubator (IN2) in partnership with Wells Fargo: this technology incubator supports energy efficiency building-related startups to overcome market gaps by providing access to technical support at NREL; Small Business Voucher Pilot: this program offers paid vouchers for applicants to access a unique skill, capability, or facility at any of the 17 DOE National Laboratories to bring next-generation clean energy technologies to market; Energy Innovation Portal: NREL designed and developed the Energy Innovation Portal, providing access to EERE focused intellectual property available for licensing from all of the DOE National Laboratories; Lab-Corps: Lab-Corps aims to better train and empower national lab researchers to understand market drivers and successfully transition their discoveries into high-impact, real world technologies in the private sector; Incubatenergy Network: the Network provides nationwide coordination of clean energy business incubators, share best practices, support clean energy entrepreneurs, and help facilitate a smoother transition to a more sustainable clean energy economy; Industry Growth Forum: the Forum is the perfect venue for clean energy innovators to maximize their exposure to receptive capital and strategic partners. Since 2003, presenting companies have collectively raised more than $5 billion in growth financing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Study of IR Loss Correction Methodologies for Commercially Available Pyranometers

This presentation provides a high-level overview of a study of IR Loss Connection Methodologies for Commercially Available Pyranometers. The IR Loss Corrections Study is investigating how various correction methodologies work for several makes and models of commercially available pyranometers in common use, both when operated in ventilators with DC fans and without ventilators, as when they are typically calibrated.

14 SOLAR ENERGY↗

Field Experience with and Potential for Multi-time Scale Grid Transactions from Responsive Commercial Buildings

The need for and concepts behind demand response are evolving. As the electric system changes with more intermittent renewable electric supply systems, there is a need to allow buildings to provide more flexible demand. This paper presents results from field studies and pilots, as well as engineering estimates of the potential capabilities of fast load responsiveness in commercial buildings. We present a sector wide analysis of flexible loads in commercial buildings, which was conducted to improve resource planning and determine which loads to evaluate in future demonstrations. These systems provide important capabilities for future transactional systems. The field analysis is based on results from California, plus projects in the northwest and east coast. End-uses considered include heating, ventilation, air conditioning and lighting. The timescales of control include day-ahead, as well as day-of, 10-minute ahead and even faster response. This technology can provide DR signals on different times scales to interact with responsive building loads. We describe the latency of the control systems in the building and the round trip communications with the wholesale grid operators.

Piette, Mary Ann↗

Making Commercial Whole Building Program Delivery Easier and Less Risky Greg Thomas, Performance Systems Development

Whole building commercial programs can be challenging to deliver due to their complexity and scope. A broad suite of Federal tools and reference standards can be leveraged to reduce program cost and risk, and improve scalability. The OpenEfficiency Initiative (OEI) is a DoE funded effort to expand the deployment of Federal tools and reference standards into whole building commercial efficiency programs. OEI is developing an open source data exchange platform which is being informed and motivated by pilots.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Roadmap Toward a Predictive Performance-based Commercial Energy Code

Energy codes have provided significant increases in building efficiency over the last 38 years, since the first national energy model code was published in late 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. The current focus on prescriptive codes has limitations including significant variation in actual energy performance depending on which prescriptive options are chosen, a lack of flexibility for designers and developers, and the inability to handle control optimization that is specific to building type and use. This paper provides a high level review of different options for energy codes, including prescriptive, prescriptive packages, EUI Target, outcome-based, and predictive performance approaches. This paper also explores a next generation commercial energy code approach that places a greater emphasis on performance-based criteria. A vision is outlined to serve as a roadmap for future commercial code development. That vision is based on code development being led by a specific approach to predictive energy performance combined with building specific prescriptive packages that are designed to be both cost-effective and to achieve a desired level of performance. Compliance with this new approach can be achieved by either meeting the performance target as demonstrated by whole building energy modeling, or by choosing one of the prescriptive packages.

Rosenberg, Michael I.↗

Understanding Occupancy Patterns in a Commercial Space

Heating, ventilation, and air conditioning (HVAC) is a prime source of energy consumption in the US. In 2006, approximately 35% of energy in the US was used for HVAC [1]. Usually building operators use a static schedule for controlling HVAC systems without having a deeper understanding of how many people use the building at different times of the day. In addition, HVAC systems operate by assuming maximum occupancy in each room, which leads to a significant energy waste, e.g., an HVAC system providing ventilation for 30 people when there are only 10 people in a room. Considering how many people use different rooms at different times of the day is very crucial for achieving building energy efficiency and providing occupant comfort. There have been several attempts to collect long term occupancy patterns from office buildings, e.g., Mitsubishi’s Electronic Research Lab (MERL) dataset [14] and Colorado School of Mines (CSMBB) dataset. However, PIR motion detectors are used in these projects for sensing occupancy and hence these datasets only reflect whether a room is occupied or not without revealing the actual person count. Similar datasets are also collected from households. Only a few datasets from commercial spaces capture actual person count, and even in these cases, the data collection period was very limited, e.g., in [3] only 5 days of occupancy data is collected as ground truth. We are the first to collect long term (9 months) occupancy data (people count) from an 11,000 square foot commercial office (second floor of Bosch Research and Technology Center Pittsburgh). In this paper, we outline some statistical results from our empirical study and explore their implications for saving energy.

42 ENGINEERING↗