Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Research on the chemical mechanism in the polyacrylate latex modified cement system

In this paper, the chemical mechanism in the polyacrylate latex modified cement system was investigated by Fourier transform infrared spectra (FT-IR), X-ray photoelectron spectroscopy (XPS), gel permeation chromatography (GPC) and compact pH meter. All results have shown that the chemical reactions in the polyacrylate modified system can be divided into three stages. The hydration reactions of cement can produce large amounts of Ca(OH){sub 2} (calcium hydroxide) and lead the whole system to be alkali-rich and exothermic at the first stage. Subsequently, this environment can do great contributions to the hydrolysis of ester groups in the polyacrylate chains, resulting in the formation of carboxyl groups at the second stage. At the third stage, the final crosslinked network structure of the product was obtained by the reaction between the carboxyl groups in the polyacrylate latex chains and Ca(OH){sub 2}.

36 MATERIALS SCIENCE↗

Investigation of the changes in microstructure and transport properties of leached cement pastes accounting for mix composition

Ca-leaching of cement-based materials induces detrimental effects on properties related to long-term durability. A better understanding of leaching degradation in terms of alterations in mineralogy, microstructure, and transport properties is important for long-term assessments of concrete and reinforced concrete structures used in nuclear waste disposal systems or in hydro structures. However, the decalcification process is not easy to study because it is extremely slow. In this study, an ammonium nitrate (NH{sub 4}NO{sub 3}) solution of 6 mol/l was used to accelerate the leaching kinetics. The experiments were performed on cement paste samples with different water/powder (w/p) and limestone filler (LS) replacement ratios. Both the change of sample mass over time and the amount of calcium ion leached out were monitored during the test. Different post-analysis techniques including SEM/SEM-EDX, XRD/QXRD, MIP, ion chromatography, and N{sub 2}-adsorption were used to characterize the microstructural and mineralogical changes. The effect of accelerated leaching on transport properties was studied by measuring the changes in water permeability and diffusivity of dissolved gases. Results showed that the square-root-time law of degradation was applicable under accelerated conditions. Both higher w/p ratios and LS replacements increased the rate of leaching propagation; the former had a more significant effect. The accelerated leaching significantly altered the microstructure of the cement paste to a material with a higher specific surface area, increased total porosity and a shift to larger pore sizes. Those changes led to a significant increase in water permeability (one to two orders of magnitude) and diffusivity (less than one order) depending on degradation state.

36 MATERIALS SCIENCE↗

Influence of polycarboxylate superplasticizer, citric acid and their combination on the hydration and workability of calcium sulfoaluminate cement

Highlights: • The dispersion efficiency of polycarboxylate superplasticizers drops quickly over time. • Citric acid maintains the dispersion efficiency of PCE over time. • Competitive adsorption between citric acid and PCE occurs. • The combination of citric acid with PCE decreases the initial dispersion efficiency of PCE. PCEs are well known to improve the initial fluidity of CSA. However, their dispersion efficiency drops quickly over time. This issue can be solved by incorporating retarders. In this context, this paper deals with the influence of citric acid, used as a retarder, PCE and their combination on the hydration and workability of CSA. Isothermal calorimetry, XRD and TG analysis were used to describe the hydration process, while workability was characterized with the mini-cone test. Adsorption behavior was investigated using total organic carbon analyzer coupled with ion chromatography. Results show that the introduction of citric acid retained the dispersion efficiency of PCE over time. However, the initial dispersion efficiency of PCE was decreased by citric acid as the latter tend to adsorb first on the surface of cement grains, inhibiting the adsorption of PCE. A dispersion model was proposed to describe the acting mechanism of these admixtures on CSA.

36 MATERIALS SCIENCE↗

Arsenic speciation and transport associated with the release of spent geothermal fluids in Mutnovsky field (Kamchatka, Russia)

The use of geothermal fluids for the production of electricity poses a risk of contaminating surface waters when spent fluids are discharged into (near) surface environments. Arsenic (As) in particular is a common component in geothermal fluids and leads to a degradation of water quality when present in mobile and bioavailable forms. We have examined changes in arsenic speciation caused by quick transition from high temperature reducing conditions to surface conditions, retention mechanisms, and the extent of transport associated with the release of spent geothermal fluids at the Dachny geothermal fields (Mutnovsky geothermal region), Kamchatka, Russia -- a high temperature field used for electricity production. In the spent fluids, the arsenic concentration reaches 9 ppm, while in natural hot springs expressed in the vicinity of the field, the As concentration is typically below 10 ppb. The aqueous phase arsenic speciation was determined using Liquid Chromatography (LC) coupled to an Inductively Coupled Plasma Mass Spectrometer (ICP-MS). The arsenic speciation in the bottom sediments (< 65 {mu}m fraction) of the local surface waters was analyzed using X-ray Absorption Spectroscopy (XAS). Arsenic in the geothermal source fluids is predominantly found as As(III), while a mixture of As(III)/As(V) is found in the water and sediment of the Falshivaia River downstream from the power plant. The extent of elevated arsenic concentrations in water is limited by adsorption to the bottom sediment and dilution, as determined using Cl{sup -} from the deep well fluids as a tracer. Analysis of the Extended X-ray Absorption Fine Structure (EXAFS) spectra shows that sediment phase arsenic is associated with both Al- and Fe-rich phases with a bi-dentate corner sharing local geometry. The geothermal waste fluids released in the surface water create a localized area of arsenic contamination. The extent of transport of dissolved As is limited to {approx}7 km downstream from the source, while As associated with bottom sediment travels {approx}3 km farther.

15 GEOTHERMAL ENERGY↗

Shell particles, trials, tribulations and triumphs

The concept of pellicular particles was imagined by Horvath and Lipsky fifty years ago. They were initially intended for the analysis of macromolecules. Later, shell particles were prepared. The rational behind this concept was to improve column efficiency by shortening the pathways that analyte molecules must travel and, so doing, to improve their mass transfer kinetics. Several brands of superficially porous particles were developed and became popular in the 1970s. However, the major improvements in the manufacturing of high-quality, fully porous particles, that took place in the same time, particularly by making them finer and more homogeneous, hampered the success of shell particles, which eventually disappeared. Recently, the pressing needs to improve analytical throughputs forced particle manufacturers to find a better compromise between the demands for higher column efficiency that require short diffusion paths of analyte molecules in columns and the need for columns that can be operated with the conventional instruments for liquid chromatography, which operate with moderate column back-pressures. This lead to the apparition of a new generation of columns packed with shell particles, which bring chromatographic columns to a level of efficiency undreamed of a few years ago. This evolution is reviewed, the reason that motivated it, and the consequences of their success are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functionalization/passivation of porous graphitic carbon with di-tert-amylperoxide

Porous graphitic carbon (PGC) particles were functionalized/passivated in situ in packed beds at elevated temperature with neat di-tert-amylperoxide (DTAP) in a column oven. The performance of these particles for high performance liquid chromatography (HPLC) was assayed before and after this chemistry with the following analytes: benzene, toluene, ethyl benzene, n-propyl benzene, n-butyl benzene, p-xylene, phenol, 4-methylphenol, phenetole, 3,5-xylenol, and anisole. After the first functionalization/passivation, the retention factors, k, of these compounds decreased by about 5% and the number of theoretical plates (N) increased by ca. 15%. These values of k then remained roughly constant after a second functionalization/ passivation but a further increase in N was noticed. In addition, after each of the reactions, the peak asymmetries decreased by ca. 15%, for a total of ca. 30%. The columns were then subjected twice to methanol at 100 C for 5 h at 1 mL/min. After these stability tests, the values of k remained roughly constant, the number of plates increased, which is favorable, and the asymmetries rose and then declined, where they remained below the initial values for the unfunctionalized columns. Functionalized and unfunctionalized particles were characterized by scanning electron microscopy and BET measurements, which showed no difference between the functionalized and unfunctionalized materials, and X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry (ToF-SIMS), where ToF-SIMS suggested some chemical differences between the functionalized and unfunctionalized materials. In particular ToF-SIMS suggested that the expected five-carbon fragments from DTAP exist at higher concentrations on DTAP-functionalized PGC. First principle calculations on model graphitic surfaces suggest that the first addition of a DTAP radical to the surface proceeds in an approximately isothermal or slightly favorable fashion, but that subsequent DTAP additions are then increasingly thermodynamically favorable. Thus, this analysis suggests that the direct functionalization/passivation of PGC with DTAP is plausible. Chemometric analyses of the chromatographic and ToF-SIMS data are also presented.

10 SYNTHETIC FUELS↗

Determination of CMPO using HPLC -UV

Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) is an extractant proposed for selective separation of radionuclide metals from used nuclear fuel solutions using solvent extraction. Radiolysis reactions can degrade CMPO and reduce separation performance and hence methods for measuring concentration of CMPO and identifying degradation products are needed. A novel high performance liquid chromatography (HPLC) method employing ultraviolet detection (UV) was developed to detect and quantitate CMPO in dodecane. Some radiolysis products in gamma and alpha irradiated CMPO solutions were identified using HPLC/electrospray ionization-mass spectrometry (ESI-MS). Validation data indicated that the HPLC-UV method for CMPO determination provided good linearity, sensitivity, procedure accuracy and system precision. CMPO-nitric acid complexes were also identified, that account for the apparent loss of CMPO in acidic environment, independent of irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automated single-ion peak fitting as an efficient approach for analyzing complex chromatographic data

Chromatography provides important detail on the composition of environmental samples and their chemical processing. However, the complexity of these samples and their tendency to contain many structurally and chemically similar compounds frequently results in convoluted or poorly resolved data. Data reduction from raw chromatograms of complex environmental data into integrated peak areas consequently often requires substantial operator interaction. This difficulty has led to a bottleneck in analysis that increases analysis time, decreases data quality, and will worsen as advances in field-based instrumentation multiply the quantity and informational density of data produced. In this work, we develop and validate an automated approach to fitting chromatographic data within a target retention time window with a combination of multiple idealized peaks (Gaussian peaks either with or without an exponential decay component). Herein we compare this single-ion peak fitting approach to drawn baseline integration methods of more than 70,000 peaks collected by field-based chromatographs spanning across a wide range of volatilities and functionalities. Accuracy of peak fitting under real-world conditions is found to be within 10%. The quantitative parameters describing the fit (e.g. coefficients, fit residuals, etc.) are found to provide valuable information to increase the efficiency of quality control and provide constraints to accurately integrate peaks that are significantly convoluted with neighboring peaks. Implementation of the peak fitting method is shown to yield accurate integration of peaks otherwise too poorly resolved to separate into individual compounds and improved quantitative metrics to determine the fidelity of the data reduction process, while substantially decreasing the time spent by operators on data reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a fast and efficient analytical technique for the isotopic analysis of fission and actinide elements in environmental matrices

An automated separation–direct analysis scheme has been developed to determine both the concentration and isotopic composition of a suite of elements down to the low picogram level in a complex silicon-based matrix. With the ultimate goal of performing rapid analysis of materials with non-natural isotopic compositions, RAPID (Rapid Analysis of Post-Irradiation Debris) consists of a high-pressure ion chromatography system directly coupled to an inductively coupled plasma mass spectrometer. The RAPID method achieves matrix exclusion and direct online analysis of the elementally separated components, yielding precise isotopic compositions for up to 40 elements in less than one hour per sample. When combined with isotope dilution, this approach shows the potential to yield elemental concentrations with low uncertainties, providing a rapid analytical method that encompasses group I and II metals, transition metals, refractory metals, platinum group metals, lanthanides, and actinides. Furthermore, the method development, robustness, sensitivity, uncertainties, and potential applications in nuclear and environmental measurements will be discussed in this paper.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modulating solvation interactions of deep eutectic solvents formed by ammonium salts and carboxylic acids through varying the molar ratio of hydrogen bond donor and acceptor

Deep eutectic solvents (DESs) have gained increasing popularity in separation science due to the fact that their physico-chemical properties can be easily fine-tuned by varying the type or ratio of hydrogen bond acceptor (HBA) and hydrogen bond donor (HBD). While it is well-known that the molar ratio of HBA/HBD affects the melting point of a eutectic mixture, much less is understood regarding its effect on the magnitude of individual solvation interactions. This is largely due to the fact that established solvatochromic dye methods lack sensitivity when the HBA/HBD ratio is varied slightly in a eutectic mixture. Herein, this study is the first to measure the variation of DES solvation interactions with small changes in the molar ratio of HBA/HBD using inverse gas chromatography (IGC). Solute-solvent interactions of three different DES systems comprised of ammonium salts and organic acids were examined. The probe molecules were studied for 18 eutectic mixtures of varied HBA and HBD composition. We report DES hydrogen bond basicity, hydrogen bond acidity, and dispersive-type interactions exhibited the greatest change when the molar ratio of HBA/HBD was varied in the eutectic mixture. Results from this study demonstrate that the HBA/HBD ratio can be used to modulate the solvation characteristics for this class of DESs in separations and that the stoichiometric ratio of the HBA/HBD is important in ensuring their reproducible preparation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing the extraction performance of cyclodextrin-containing supramolecular deep eutectic solvents versus conventional deep eutectic solvents by headspace single drop microextraction

A headspace single drop microextraction (HS-SDME) method coupled with high performance liquid chromatography was developed to compare the extraction of eighteen aromatic organic pollutants from aqueous solutions using cyclodextrin-based supramolecular deep eutectic solvents (SUPRADESs) and alkylammonium halide-based conventional deep eutectic solvents (DESs). Different derivatives of beta-cyclodextrin (β-CD) were employed as hydrogen bond acceptors (HBA) in SUPRADESs and the extraction performance investigated. SUPRADES comprised of the 20 wt% native β-CD HBA provided the highest enrichment factors of analytes compared to SUPRADESs comprised of other derivatives of β-CD (random methylated β-cyclodextrin, heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin, and 2-hydroxypropyl β-cyclodextrin). In addition, native β-CD and its derivatives were dissolved in the neat DESs and their effect on the extraction of analytes examined. Dissolution of 20 wt% native β-CD in the choline chloride ([Ch + ][Cl - ]):2Urea DES resulted in a significant increase in the extraction efficiencies of target analytes compared to the neat [Ch + ][Cl - ]:2Urea DES. Under optimum conditions, the extraction method required a solvent microdroplet of 6.5 μL, 1000 rpm stir rate, 30% (w/v) salt concentration, and a temperature of 40 °C. The tetrabutylammonium chloride: 2 lactic acid DES resulted in the highest enrichment factors while the [Ch + ][Cl - ]:2Urea DES had the lowest for most of the analytes among the evaluated solvents. The method provided limits of detection (LODs) down to 35 μg L -1 . Finally, the developed method was applied for the analysis of spiked tap and lake water, where relative recoveries ranging from 83.7% -119.7% and relative standard deviations lower than 19.2% were achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of persistent contaminants and personal care products by dispersive liquid-liquid microextraction using hydrophobic magnetic deep eutectic solvents

Here, in this work, hydrophobic magnetic deep eutectic solvents (HMDESs) were used in the development of a simple and rapid dispersive liquid-liquid microextraction (DLLME) approach coupled to high performance liquid chromatography with UV detection (HPLC-UV) for the determination of ten organic contaminants including five polycyclic aromatic hydrocarbons, four UV filters, and a pesticide from water at trace levels. The HMDESs were prepared by mixing a hydrogen bond acceptor, metal halide salt, and hydrogen bond donor in suitable molar ratios. Two HMDESs, 2 tetraoctylammonium bromide ([N 8888 + ][Br - ]): cobalt chloride (CoCl 2 ): 4 octanoic acid (OA) and 3 trioctylphosphine oxide (TOPO): neodymium chloride (NdCl 3 ): 3 OA, offered the highest analyte extraction efficiency overall and were chosen as suitable solvents for validation of the microextraction method. Under optimized extraction conditions, the method required 30 µL of HMDES as extraction solvent, acetone (87.5 µL) as disperser solvent, a NaCl concentration of 30% (w/v), and an extraction time of 120 s at 20°C. Enrichment factors of the analytes ranged from 44.6 for 3-(4-methylbenzylindene) camphor to 66.0 for 2-ethylhexyl-4-(dimethyl)aminobenzoate. The method provided low limits of detection (LODs) ranging from 0.5 to 4.5 µg L -1 , and acceptable precision, with RSD values lower than 9.6%. Furthermore, the validated method was successfully applied for tap and lake water analysis, resulting in relative recoveries of spiked samples ranging between 94.7 and 119.2%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of silver($\mathrm{I}$) ion reduction on the selectivity of olefins, paraffins, and aromatic compounds by gas chromatographic stationary phases consisting of silver($\mathrm{I}$) salts in ionic liquids

We report the olefin/paraffin selectivity offered by ionic liquid (IL) stationary phases can be enhanced through the addition of silver(I) ion, which is well-known to undergo selective complexation with unsaturated compounds. However, such stationary phases often suffer from the loss of chromatographic selectivity as silver(I) ion can be reduced to elemental silver. To maintain the separation performance of silver(I) ion/IL stationary phases, an understanding of factors and conditions that promote the reduction of silver(I) ion is needed. In this study, capillary gas chromatography columns featuring a stationary phase consisting of the 1-decyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 10 MIM + ][NTf 2 - ]) IL impregnated with [Ag + ][NTf 2 - ] were examined to investigate the effects of temperature, hydrogen content in exposure gas stream, and time of heating/exposure events on olefin selectivity. Retention factors of representative analytes, such as C 6 olefins and paraffins as well as aromatic compounds, were measured after subjecting the columns to the aforementioned conditions, followed by an evaluation of selectivity factors over time. Selectivity factors of olefins and aromatic compounds were observed to decrease significantly when the stationary phases were heated to temperatures higher than 110°C as well as being subjected to mixed gas streams containing greater than 50 mol% of hydrogen. As constant column heating temperatures were applied under exposure gas mixtures containing hydrogen and nitrogen, a gradual decrease in analyte selectivity factors was observed under prolonged periods of time. However, application of a ternary gas mixture comprised of 25/50/25 mol% hydrogen/nitrogen/methane resulted in an increase in the 3-hexyne/cis-2-hexene selectivity when measured at 120°C for 60 h, due to a smaller decrease in the retention factor of 3-hexyne compared to cis-2-hexene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of gold from irradiated actinide material utilizing a 2- thenoyltrifluoroacetone extraction resin

Post-detonation nuclear forensics capabilities depend on the ability to rapidly isolate radionuclides to improve measurement quality. In this work an extraction chromatography resin was developed utilizing the extractants thenoyltrifluoroacetone and 1-octanol supported on Eichrom prefilter resin. Here the resin was tested in nitric and hydrochloric acid matrices. In nitric acid matrices the resin is able to extract zirconium, while in hydrochloric acid matrices it is possible to extract iron and gallium. In all acid conditions tested gold is retained but can be removed from the column with a 10% thiourea rinse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Adsorption of terbium (III) on DGA and LN resins: Thermodynamics, isotherms, and kinetics

Two commercially available extraction chromatography (EXC) resins containing N,N,N’,N’-tetra-n-octyldiglycolamide (DGA Resin, Normal, 50 – 100 μm) and Bis(2-ethylhexyl) phosphate (LN Resin, 100 – 150 μm) were used as adsorbents to study fundamental adsorption properties such as thermodynamic values, equilibrium isotherms, and kinetic uptake models for terbium(III) adsorption. Weight distribution ratios (D w ) for terbium on DGA and LN resins were measured using a [ 160 Tb]Tb 3+ radiometric tracer in nitric acid as a function of acidity, temperature, initial analyte concentration, and equilibrium time. The D w values showed increasing binding affinity for DGA resin at high nitric acid concentrations and decreasing binding affinity for LN resins. Thermodynamic studies for DGA and LN resins revealed that the Gibbs free energy (ΔG) increased consistently with temperature. To model equilibrium data, increasingly higher parameter equilibrium isotherm models (Henry (1) < Langmuir, Freundlich (2) < Redlich-Peterson (3) < Fritz-Schluender (4)) were compared on their root mean squared errors (RMSE) and adjusted determination coefficients to determine the most applicable model. In all cases, the empirical four-parameter Fritz-Schluender isotherm demonstrated a superior fit. Similar comparisons for reaction-based kinetic models (Pseudo-first-order < Pseudo-second-order < Pseudo-n-order) revealed that the higher-order PNO model yielded a superior fit of kinetic data for both resins. Furthermore, in some cases, adsorption isotherms and kinetic models could also be modeled by a lower-order model with minimal change in error parameters. Weber-Morris plots revealed that two linear sections are observed for each resin, where the first linear segment is attributed to fast (film diffusion) adsorption of terbium, followed by slower intraparticle diffusion of terbium through the pores as the rate-limiting step. Based on the Weber-Morris plot, both film and intraparticle diffusion are involved in controlling the kinetic rate of adsorption for DGA and LN resins.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Polymeric ionic liquids containing copper(I) and copper(II) ions as gas chromatographic stationary phases for olefin separations

Copper(I) ions (Cu + ) are used in olefin separations due to their olefin complexing ability and low cost, but their instability in the presence of water and gases limits their widespread use. Ionic liquids (ILs) have emerged as stabilizers of Cu + ions and prevent their degradation, providing high olefin separation efficiency. There is limited understanding into the role that polymeric ionic liquids (PILs), which possess similar structural characteristics to ILs, have on Cu + ion-olefin interactions. Moreover, copper ions with diverse oxidation states, including Cu + and Cu 2+ ions, have been rarely employed for olefin separations. In this study, gas chromatography (GC) is used to investigate the interaction strength of olefins to stationary phases composed of the 1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 6 MIM + ][NTf 2 – ]) IL and the poly(1-hexyl-3-vinylimidazolium [NTf 2 – ]) (poly([C 6 VIM + ][NTf 2 – ])) PIL containing monovalent and divalent copper salts (i.e., [Cu + ][NTf 2 – ] and [Cu 2+ ]2[NTf 2 – ]). The chromatographic retention of alkenes, alkynes, dienes, and aromatic compounds was examined. Incorporation of the [Cu 2+ ]2[NTf 2 – ] salt into a stationary phase comprised of poly(dimethylsiloxane) resulted in strong retention of olefins, while its addition to the [C 6 MIM + ][NTf 2 – ] IL and poly([C 6 VIM + ][NTf 2 – ]) PIL allowed for the interaction strength to be modulated. Olefins exhibited greater affinities toward IL and PIL stationary phases containing the [Cu 2+ ]2[NTf 2 – ] salt compared to those with the [Cu + ][NTf 2 – ] salt. Elimination of water from both copper salts was observed to be an important factor in promoting olefin interactions, as evidenced by increased olefin retention upon exposure of the stationary phases to high temperatures. Furthermore, to evaluate the long-term thermal stability of the stationary phase, chromatographic retention of probes was measured on the [Cu 2+ ]2[NTf 2 – ]/[C 6 MIM + ][NTf 2 – ] IL stationary phase after its exposure to helium at a temperature of 110°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Perturbations in the Lipid Profile of Individuals with Newly Diagnosed Type 1 Diabetes Mellitus: Lipidomics Analysis of a Diabetes Antibody Standardization Program Sample Subset

Objectives: To characterize the lipid profile of individuals with newly diagnosed type 1 diabetes mellitus using LC-MS-based lipidomics and the accurate mass and time (AMT) tag approach. Design and methods: Lipids were extracted from plasma and sera of 10 subjects from the Diabetes Antibody Standardization Program (years 2000-2005) and 10 non-diabetic subjects and analyzed by capillary liquid chromatography coupled with a hybrid ion-trap-Fourier transform ion cyclotron resonance mass spectrometer. Lipids were identified and quantified using the AMT tag approach. Results: Five hundred sixty lipid features differentiated (q < 0.05) diabetic from healthy individuals in a partial least-squares analysis, characterizing of individuals with recently diagnosed type 1 diabetes mellitus. Conclusions: A lipid profile associated with newly diagnosed type 1 diabetes may aid in further characterization of biochemical pathways involved in lipid regulation or mobilization and lipotoxicity of pancreatic beta-cells.

59 BASIC BIOLOGICAL SCIENCES↗

Fouling characterization and treatment of water reuse concentrate with membrane distillation: Do organics really matter

Membrane distillation (MD) for the treatment of concentrated brines has been limited in part by membrane fouling, resulting in subsequent flux decline and membrane wetting. This study provides new insight into the identification of fouling and scaling mechanisms and pretreatment strategies for mitigating flux decline with MD treatment of water reuse reverse osmosis concentrate (ROC). Bench-scale direct contact MD experiments were performed with untreated and pretreated ROC. Biological activated carbon (BAC), chemical water softening, or fluidized bed crystallization reactor coupled with ion exchange (FBCR-IX) were selected as pretreatment strategies to isolate the effects of organic fouling and calcium scaling. Organic and inorganic compounds were analyzed by high-performance liquid chromatography (HPLC) and inductively coupled plasma mass spectrometry (ICP-MS). Calcium ions were found to be the major contributor to flux decline despite the high organic content in the ROC. Minimal organic fouling is likely because the organic matter in the ROC is hydrophilic, limiting hydrophobic-hydrophobic interactions between the organics and the membrane. Furthermore, the water flux declined by 63 % after removing organic compounds by BAC pretreatment, with 60 % of the calcium mass precipitating from the solution. Whereas, the water flux remained constant after removing multivalent ions with fluidized bed crystallization. Cleaning the membrane by acid washing and temperature reversal recovered 73 % and 12 % of the water flux, respectively. The analyses outlined in this study can assist in selecting appropriate fouling and scaling mitigation strategies for water reuse ROC and a wide range of feed solutions used in MD applications.

42 ENGINEERING↗