Impact of battery degradation on energy arbitrage revenue of grid-level energy storage

This study investigates the representation of battery degradation in grid level energy storage applications. In particular, we focus on energy arbitrage, as this is a potential future large-scale application of energy storage and there is limited existing research combining the modelling of battery degradation and energy storage arbitrage. We implement two different representations of battery degradation within an energy arbitrage model, and show that degradation has a strong impact on battery energy storage system (BESS) profitability. In a case study using historical electricity market prices from the MISO electricity market in the United States, we find that the achievable net present value (at an interest rate of 10%) for a battery system with a C-rate of 1C dropped from 358 /kWh in the case considering no degradation to 194-314 /kWh depending on the battery degradation model and assumptions for end of life (EOL) criteria. This corresponds to a reduction in revenue due to degradation in the 12-46% range.Furthermore, we find that reducing the cycling of the bat-tery via introducing a penalty cost in the objective function of the energy arbitrage optimization model can improve the profitability over the life of the BESS.

25 ENERGY STORAGE↗

RODeO (Revenue Operation and Device Optimization Model) [SWR 20-67]

The Revenue, Operation, and Device Optimization (RODeO) model explores optimal system design and operation considering different levels of grid integration, equipment cost, operating limitations, financing, and credits and incentives. RODeO is a price-taker model formulated as a mixed-integer linear programming (MILP) model in the GAMS modeling platform. The objective is to maximizes the net revenue for a collection of equipment at a given site. The equipment includes generators (e.g., gas turbine, steam turbine, solar, wind, hydro, fuel cells, etc.), storage systems (batteries, pumped hydro, gas-fired compressed air energy storage, long-duration systems, hydrogen), and flexible loads (e.g., electric vehicles, electrolyzers, flexible building loads). The input data required by RODeO can be classified into three bins: 1) utility service data, which refers to retail utility rate information (meter cost, energy and demand charges), 2) electricity market data, which include energy and reserve prices, 3) other inputs, which refer to additional electrical demand, product output demand, technological assumptions, financial properties, and operational parameters.

Guerra Fernandez, Omar Jose↗

The benefits of grid-scale storage on Oahu

The Hawaiian Electric Company intends to procure grid-scale Battery Energy Storage System (“BESS”) capacity. The purpose of this study is to determine whether providing contingency reserve or time-of-day shifting is of more benefit to the Oahu grid, and to better understand the relationship between BESS size and level of benefit. This is an independent study by Sandia, and is not being used to support the regulatory case for BESS capacity by Hawaiian Electric. The study team created a production cost model of the Oahu grid using data primarily from the Hawaiian Electric Company. The proposed BESS supplied contingency reserve in one set of runs and time-of-day shifting in another. Supplying contingency reserve led to larger savings than time-of-day energy shifting. Assuming a renewable reserve and a quick-start reserve, and $15/MMBtu for Low-Sulphur Fuel Oil, the 50-MW/25-MWh, 100-MW/50-MWh, and 150-MW/75-MWh systems supplying contingency reserve provided, respectively, savings of 9.6, 15.6, and 18.3 million USD over system year 2018. Over the range of fuel prices tested, these cost savings were found to be directly proportional to the cost of fuel. Lastly, as the focus is the operational benefit of BESS capacity, the capacity value of the BESS was not included in benefit calculations.

25 ENERGY STORAGE↗

Simulation of a Flywheel Electrical System for Aerospace Applications

A Flywheel Energy Storage Demonstration Project was initiated at the NASA Glenn Research Center as a possible replacement for the battery energy storage system on the International Space Station (ISS). While the hardware fabrication work was being performed at a university and contractor's facility, the related simulation activity was begun at Glenn. At the top level, Glenn researchers simulated the operation of the ISS primary electrical system (as described in another paper) with the Flywheel Energy Storage Unit (FESU) replacing one Battery Charge and Discharge Unit (BCDU). The FESU consists of a Permanent Magnet Synchronous Motor/Generator (PMSM), which is connected to the flywheel; the power electronics that connects the PMSM to the ISS direct-current bus; and the associated controller. The PMSM model is still under development, but this paper describes the rest of the FESU model-the simulation of the converter and the associated control system that regulates energy transfer to and from the flywheel.

Truong, Long V.↗

Laboratory evaluation of a pilot cell battery protection system for photovoltaic applications

An energy storage method for the 3.5 kW battery power system was investigated. The Pilot Cell Battery Protection System was tested for use in photovoltaic power systems and results show that this is a viable method of storage battery control. The method of limiting battery depth of discharge has the following advantages: (1) temperature sensitivity; (2) rate sensitivity; and (3) state of charge indication. The pilot cell concept is of interest in remote stand alone photovoltaic power systems. The battery can be protected from damaging overdischarge by using the proper ratio of pilot cell capacities to main battery capacity.

Cataldo, R. L.↗

Flow-Assisted Alkaline Battery: Low-Cost Grid-Scale Electrical Storage using a Flow-Assisted Rechargeable Zinc-Manganese Dioxide Battery

GRIDS Project: Traditional consumer-grade disposable batteries are made of Zinc and Manganese, 2 inexpensive, abundant, and non-toxic metals. But these disposable batteries can only be used once. If they are recharged, the Zinc in the battery develops filaments called dendrites that grow haphazardly and disrupt battery performance, while the Manganese quickly loses its ability to store energy. CUNY Energy Institute is working to tame dendrite formation and to enhance the lifetime of Manganese in order to create a long-lasting, fully rechargeable battery for grid-scale energy storage. CUNY Energy Institute is also working to reduce dendrite formation by pumping fluid through the battery, enabling researchers to fix the dendrites as they’re forming. The team has already tested its Zinc battery through 3,000 recharge cycles (and counting). CUNY Energy Institute aims to demonstrate a better cycle life than lithium-ion batteries, which can be up to 20 times more expensive than Zinc-based batteries.

ARPA-E↗

Cathode architectures for alkali metal / oxygen batteries

Electrochemical energy storage devices, such as alkali metal-oxygen battery cells (e.g., non-aqueous lithium-air cells), have a cathode architecture with a porous structure and pore composition that is tailored to improve cell performance, especially as it pertains to one or more of the discharge/charge rate, cycle life, and delivered ampere-hour capacity. A porous cathode architecture having a pore volume that is derived from pores of varying radii wherein the pore size distribution is tailored as a function of the architecture thickness is one way to achieve one or more of the aforementioned cell performance improvements.

25 ENERGY STORAGE↗

Energy Storage: Days of Service Sensitivity Analysis

This presentation presents results from a DOE Record on a screening financial analysis for energy storage technologies (e.g. hydrogen, battery). Current costs and technical potential costs are evaluated. Results suggest hydrogen systems are economically advantageous for storage durations longer than 13 hours while battery storage technologies are cheaper for durations less than 13 hours.

30 DIRECT ENERGY CONVERSION↗

Cross-Platform Analysis to Improve Cell Design for Safety

While consumer electronics and electric vehicles continue to push the market demanding for more energy in existing Li-ion batteries and lower costs, advanced battery designs could not meet the expectation to produce reliable and safe products at such a pace. There is a need to holistically re-think the design approach. INL's expertise in the current research of battery diagnostics and prognostics could fill this gap. In this presentation, the concept and approach will be discussed to explain why this is feasible and possible to change the paradigm of battery technology development from the conventional path.

25 ENERGY STORAGE↗

A Neural Optimizer With Decision-Focused Learning for Optimal Energy Storage Operation

Here, this article introduces a neural optimizer-based framework for optimizing battery energy storage system (BESS) control for grid services, including demand charge and energy cost reduction. By leveraging decision-focused learning (DFL), the proposed framework ensures seamless integration and adaptation, significantly enhancing control performance. A patch time-series transformer is employed for peak load forecasting, incorporating aleatoric uncertainty quantification to account for forecasting uncertainties within the decision-making process. The framework utilizes a solver-in-the-loop approach to generate optimal BESS actions, which are then used to train the neural optimizer-based agent. By co-optimizing both BESS operational modes and output power within the NN, the system achieves improved performance and robustness. After initial training, the forecasting and control models are jointly fine-tuned to account for forecasting errors, further improving decision precision and efficiency through DFL. Case studies are performed to validate the performance of the framework using multiple real-world datasets, demonstrating superior performance in monthly peak load forecasting compared to state-of-the-art models. In addition, the results are compared against existing decision-making approaches. The results demonstrate a reduction in monthly peak forecasting error by approximately 15% across various performance measures and achieve an optimization gap for BESS operation that is about three times smaller compared to existing methods.

Kim, Hyeonjin [Pacific Northwest National Laborato↗

Grid Inertial Response-Based Probabilistic Determination of Energy Storage System Capacity Under High Solar Penetration

It is well-known that responsive battery energy storage systems (BESSs) are an effective means to improve the grid inertial response to various disturbances including the variability of the renewable generation. One of the major issues associated with its implementation is the difficulty in determining the required BESS capacity mainly due to the large amount of inherent uncertainties that cannot be accounted for deterministically. In this study, a probabilistic approach is proposed to properly size the BESS from the perspective of the system inertial response, as an application of probabilistic risk assessment (PRA). The proposed approach enables a risk-informed decision-making process regarding (1) the acceptable level of solar penetration in a given system and (2) the desired BESS capacity (and minimum cost) to achieve an acceptable grid inertial response with a certain confidence level.

25 ENERGY STORAGE↗

CoEx Electrode Structuring for High Energy and Fast Charging Lithium-Ion Batteries

This project was a collaboration between SRI International (SRI) and Oak Ridge National Laboratory (ORNL) focused on advancing SRI’s CoEx technology for printing of battery electrodes with structured porosity, specifically for improving fast charging performance. Prior work funded by the Vehicle Technologies Office (VTO) served as proof-of-concept for CoEx printing, with the scope limited to demonstrating that CoEx structuring in the cathode would improve discharge performance. In that work, a thick cathode was paired with an anode produced through conventional means (i.e. it had no structuring), and the baseline comparison was a cell with conventionally produced cathode and anode of similar loading, along with a lower loaded cell that was intended to represent cells of typical loading. The result of that work showed that the CoEx cells had higher energy density than the thin baseline cells, due to the thicker electrode layers, and had much higher power density than the thick baseline cells at higher discharge rates, because the CoEx cathode had higher performance than the conventional cathode. In this project, we proposed to extend the CoEx technology to structure both the anode and cathode of a lithium ion battery, resulting in at least a 20% increase in energy density under fast charging conditions, while reducing costs by 15% and cutting energy usage during production.

25 ENERGY STORAGE↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

14 SOLAR ENERGY↗

Hierarchical Resilience Planning for Networked Microgrids: A Case Study of Puerto Rico

Microgrids can be designed to enhance the energy resilience of communities and critical infrastructures, such as hospitals, data centers, and communication networks, which are vulnerable to frequent weather-related disruption. Coordinating multiple microgrids in a network can leverage the geographical diversity of load and generation resources while enabling resilient and cost-effective planning of the distribution system. Designing a networked microgrid is complex, involving intricate technical assessment, cost-benefit analysis, site-specific requirements, and the evaluation of existing resources. Therefore, this paper proposes a hierarchical resilience planning framework and performs an extensive techno-economic analysis for the design of a networked microgrid. Hierarchical resilience planning involves technology sizing at an individual community level to meet the critical load and satisfy resilience criteria, and resource optimization at networked microgrid level to provide a higher level of resilience and energy adequacy. A real-world case of Puerto Rico's cooperative microgrid “Microrred de la Montaña” is investigated considering localized electricity tariffs, site-specific demand profiles, solar generation, and existing hydro resources. Multiple optimization scenarios are developed based on the resiliency requirement to estimate the capacity of solar photovoltaic and battery energy storage (BES) to be installed at each substation. The results provide the optimal sizing for individual community and networked microgrid to withstand 1day and 3-day outages along with the criteria for critical load.

13 - HYDRO ENERGY↗

A Coupled Electrochemical-Thermal Failure Model for Predicting the Thermal Runaway Behavior of Lithium-Ion Batteries

Thermal runaway is always a troublesome problem that hinders the safe application of high energy lithium-ion batteries. There is an urgent need to interpret the voltage and temperature changes and their underlying mechanisms during thermal runaway, in order to guide the safe design of a battery system. This paper is dedicated to building a coupled electrochemical-thermal model that can well predict the voltage drop and temperature increase during thermal runaway. The model can capture the underlying mechanism of 1) the capacity degradation under high temperature; 2) the internal short circuit caused by the thermal failure of the separator; and 3) the chemical reactions of the cell components that release heat under extreme temperature. The model is validated using by experimental data, therefore the modeling analysis has high fidelity. We employ the model to analyze 1) the capacity degradation under extreme temperature; 2) the influence of the SEI decomposition and regeneration on the thermal runaway behavior; 3) the heat generation by internal short circuit in the thermal runaway process. In conclusion, the discussions presented here help extend the usage of lithium-ion batteries at extreme high temperature (>80 degrees C), and guide the safe design of lithium-ion batteries with less hazard level during thermal runaway.

25 ENERGY STORAGE↗

High-efficiency, anode-free lithium–metal batteries with a close-packed homogeneous lithium morphology

Anode-free lithium–metal batteries (LMBs) are ideal candidates for high-capacity energy storage as they eliminate the need for a conventional graphite electrode or excess lithium–metal anode. Current anode-free LMBs suffer from low Coulombic efficiency (CE) due to poor lithium stripping efficiency. Advanced electrolyte development is a promising route to maximize lithium plating and stripping CE and minimize capacity fade. However, a poor understanding of the mechanisms by which advanced electrolytes improve performance hampers progress in the practical development of anode-free LMBs. Here, we use synchrotron techniques and other tools to analyze the influence of three commercially available electrolytes on the composition, heterogeneity, kinetics, morphology, and electrochemistry of anode-free LMBs. Advanced electrolytes improve the electrochemical performance of anode-free LMBs by forming much denser and better-packed Li morphologies on a Cu current collector than on the conventional electrolyte. Li plates uniformly over the electrode area with the advanced electrolytes rather than in a few active sites. Inactive crystalline Li with heterogeneous distribution dominates the capacity degradation of anode-free cells, especially with the conventional electrolyte, indicating that reducing the amount of “dead” crystalline Li will significantly improve the cycling stability of anode-free cells. Finally, the understanding of the Li plating and stripping process obtained from this work will accelerate the development of anode-free LMBs with high efficiency.