Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BNL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Progress in the Long ${\rm Nb}_{3}{\rm Sn}$ Quadrupole R&D by LARP

After the successful test of the first long Nb 3 Sn quadrupole (LQS01) the US LHC Accelerator Research Program (LARP, a collaboration of BNL, FNAL, LBNL and SLAC) is assessing training memory, reproducibility, and other accelerator quality features of long Nb 3 Sn quadrupole magnets. LQS01b (a reassembly of LQS01 with more uniform and higher pre-stress) was subjected to a full thermal cycle and reached the previous plateau of 222 T/m at 4.5 K in two quenches. A new set of four coils, made of the same type of conductor used in LQS01 (RRP 54/61 by Oxford Superconducting Technology), was assembled in the LQS01 structure and tested at 4.5 K and lower temperatures. The new magnet (LQS02) reached the target gradient (200 T/m) only at 2.6 K and lower temperatures, at intermediate ramp rates. The preliminary test analysis, here reported, showed a higher instability in the limiting coil than in the other coils of LQS01 and LQS02.

43 PARTICLE ACCELERATORS↗

Fabrication of First 4-m Coils for the LARP MQXFA Quadrupole and Assembly in Mirror Structure

The US LHC Accelerator Research Program is constructing prototype interaction region quadrupoles as part of the US in-kind contribution to the Hi-Lumi LHC project. The low-beta MQXFA Q1/Q3 coils have a 4-m length and a 150 mm bore. The design is first validated on short, one meter models (MQXFS) developed as part of the longstanding Nb3Sn quadrupole R&D by LARP in collaboration with CERN. In parallel, facilities and tooling are being developed and refined at BNL, LBNL, and FNAL to enable long coil production, assembly, and cold testing. Long length scale-up is based on the experience from the LARP 90 mm aperture (TQ-LQ) and 120 mm aperture (HQ and Long HQ) programs. A 4-m long MQXF practice coil was fabricated, water jet cut and analyzed to verify procedures, parts, and tooling. In parallel, the first complete prototype coil (QXFP01a) was fabricated and assembled in a long magnetic mirror, MQXFPM1, to provide early feedback on coil design and fabrication following the successful experience of previous LARP mirror tests.

43 PARTICLE ACCELERATORS↗

Fabrication and test of model superconducting inflector for g-2 at FNAL

The new FNAL g-2 experiment is based on the muon storage ring previously used at BNL. The 1.45 T dipole magnetic field in the storage ring is required to have very high (1 ppm) homogeneity. The muon beam injected into the ring must be transported through the magnet yoke and the main superconducting coil cryostat with minimal distortions. The old inflector magnet shielded the main dipole fringe field inside the muon transport beam pipe, with an outer NbTi superconducting screen, and did not disturb the field in the area of circulating beam. Nevertheless, this magnet had coils with closed ends in which a large fraction of muon beam particles were lost. A new magnet is envisioned utilizing the same cross section as the original with open ends for improved beam transport. A model magnet has been wound utilizing 3d printed parts to verify the magnetic behavior of the magnet at room temperature and validate winding of the complicated geometry required for the magnet ends. Finally, room temperature magnetic measurements have been performed and confirm the magnetic design

43 PARTICLE ACCELERATORS↗

The HL-LHC Low-β Quadrupole Magnet MQXF: From Short Models to Long Prototypes

Among the components to be upgraded in LHC interaction regions for the HiLumi-LHC projects are the inner triplet (or low-β) quadrupole magnets, denoted as Q1, Q2a, Q2b, and Q3. Here, the new quadrupole magnets, called MQXF, are based on Nb3Sn superconducting magnet technology and operate at a gradient of 132.6 T/m, with a conductor peak field of 11.4 T. Q1 and Q3 are composed of magnets (called MQXFA) fabricated by the U.S. Accelerator Upgrade Project (AUP), with a magnetic length of 4.2 m. Q2a and Q2b consist of magnets (called MQXFB) fabricated by CERN, with a magnetic length of 7.15 m. After a series of short models, constructed in close collaboration by the US and CERN, the development program is now entering in the prototyping phase, with CERN on one side and BNL, FNAL, and LBNL on the other side assembling and testing their first long magnets We provide in this paper a description of the status of the MQXF program, with a summary of the short model test results, including quench performance, and mechanics, and an update on the fabrication, assembly, and test of the long prototypes.

43 PARTICLE ACCELERATORS↗

Vertical Magnetic Measurements of the First Full-Length Prototype MQXFAP2 Quadrupole for the LHC Hi-Lumi Accelerator Upgrade Project

This paper reports the commissioning of the vertical magnetic measurement system and the room temperature (warm) and cryogenic (cold) magnetic field measurements of the first full-length (4.2 m) quadrupole built by the U.S. Accelerator Upgrade Project (AUP) (formerly the LARP collaboration) for the high luminosity upgrade of the Large Hadron Collider at CERN. The magnet, designated MQXFAP2, is a prototype preceding production for the AUP which will provide ten sets of 8.4-m superconducting insertion region quadrupoles for the Hi-Lumi Upgrade. The quadrupoles will be built by assembling two 4.2-m magnets in a single cryostat. Agreement between Brookhaven National Laboratory's (BNL's) and Lawrence Berkeley National Laboratory's (LBNL's) warm measurement data has indicated that the upgraded vertical magnetic measurement system at Brookhaven National Laboratory is ready for MQXFA magnet production testing. Lastly, the cold magnetic measurement has been performed and preliminary data analysis has been conducted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New Approach and Test Facility for High Field Accelerator Magnets R&D

This paper presents a new approach for developing and demonstrating high field magnet technology based on a magnet and test facility developed specifically for it. The traditional approach for carrying out high field magnet R&D has been building a new magnet to demonstrate a new design, new material or new technology. However, building a high field magnet is time consuming and expensive. To overcome this limitation, Brookhaven National Laboratory (BNL) built and successfully tested a 10 T Nb 3 Sn dipole DCC017 with large enough open or clear space (31 mm wide and 338 mm high) so that a pair of racetrack coils could be inserted into this opening without disassembling the magnet. The motivation be-hind this design was to facilitate a magnet R&D program where the new coils (with a large range in width and height accommodated) would reside in a high field region in direct contact with the existing coils (just as other magnet coils) and thus become an integral part of the magnet. We summarize the approach, the magnet, the test facility, past experiences, current and future test plans and planned up-grade. Here, the magnet facility is now available to service the needs of the wider community for testing cable and insert coils in a back-ground field of up to 10 T.

43 PARTICLE ACCELERATORS↗

Fracture Failure Analysis for MQXFA Magnet Aluminum Shells

The High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is approaching the production phase of the US-contributed Q1 and Q3 Interaction Region Quadrupoles (MQXFA). The structures for the MQXFA prototypes were design and inspected by the US-LARP (LHC Accelerator Research Program), AUP developed criteria, which will be used for the pre-series structures. As the first two full-length prototypes with 4.2 m magnetic length, MQXFAP1 and MQXFAP2, were designed and assembled at Lawrence Berkeley National Laboratory (LBNL), and tested at Brookhaven National Laboratory (BNL). The end aluminum short shell of MQXFAP2 was fractured along the shell length during the test, and tests were stopped. Analytical and Finite Element analysis were performed in light of the graded procedure defined in the Structure Design Criteria to investigate the fracture failure for MQXFAP2. In this paper, we report the fracture analysis of the current shell design, including the elasto-plastic simulations with submodel technique, and calculations with Linear Elastic Fracture Mechanics (LEFM). Test material properties are also presented. The results of this analysis explain why the end shell of MQXFAP2 failed, and suggest fillets on the end shell notches to meet the margin specified in the Structural Design Criteria.

43 PARTICLE ACCELERATORS↗

3D Mechanical Analysis of a Compact Nb 3 Sn IR Quadrupole for EIC

Abstract-The Electron Ion Collider (EIC) will require large aperture quadrupole magnets for the Hadron beam in the insertion region. Key requirements include high field, compact size, and tight control of the fringe fields. A 120 mm aperture, 308.4 mm outer diameter actively shielded Nb 3 Sn quadrupole model is under development to support these goals. This work is being carried out by a collaboration of BNL, JLAB and LBNL. A compact shell-based structure preloaded with a bladder and key system was developed for this project. In this paper, the effect of the compact structure on the mechanical behavior was investigated. In particular, the impact of the assembly tolerances and coil size variations on the actual coil stresses and bladder pressures was computed and compared with results from larger bladder and key structures developed for the LHC IR. The longitudinal preload is provided by stainless steel rods. Differently from other bladder and key magnets, the rods are first preloaded axially before coil axial load is applied. This new design aims to increase the overall stiffness of the system and reduce the longitudinal coil displacement during powering. Based on the results of a 3D mechanical analysis, the preliminary preload targets for the EIC quadrupole assembly will be reviewed and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assembly and Pre-Loading Specifications for the Series Production of the Nb 3 Sn MQXFA Quadrupole Magnets for the HL-LHC

We report the High Luminosity LHC (HL-LHC) Project is planning to install 16 cold-masses made with Nb 3 Sn quadrupole magnets in the LHC Interaction Regions to significantly increase its luminosity. Half of these cold masses are fabricated at BNL, FNAL, and LBNL under the US Accelerator Research Program (AUP). Each cold mass includes two identical Nb 3 Sn quadrupole magnets, called MQXFA with a magnetic length of 4.2 m. Currently, the AUP project has completed the fabrication and test of the first 5 pre-series magnets, and is working on the following 16 magnets for the series production. The brittleness and strain sensitivity of the Nb 3 Sn superconducting material requires a careful definition of the allowable maximum stress in the windings during magnet assembly and pre-load, and a tight control of their variation within the whole coil length. Therefore, a series of assembly and pre-load specifications have been defined with the goals of minimizing the risk of conductor degradation and providing the mechanical support required to reach the nominal current during powering. In this paper we present the specifications defined for the MQXFA magnets and applied during the different assembly phases and during the pre-load process of the first 5 pre-series magnets.

43 PARTICLE ACCELERATORS↗

A 2K Design for the Low Beta Quadrupoles Q1ApF/Q1BpF for the Interaction Region of the Electron-Ion Collider (EIC)

The forward hadron magnets of the planned electron-ion collider (EIC) at Brookhaven National Laboratory (BNL) present a set of unique challenges. In addition to the typical magnet requirements in terms of aperture, gradient, and field quality, the field leakage from the hadron magnets to the electron apertures must be negligible. Due to the close proximity of the two apertures the shielding solution for the electron beam can affect the field quality of the hadron magnets. Here, in this paper, a design for the Q1ApF/Q1BpF low beta quadrupoles based on NbTi Rutherford cable operating at 2K is presented. In this design the electron beam shielding and the required field quality in the hadron magnets are achieved using a set of cutouts in the iron yoke solely without resorting to active shielding. The chosen layout along with the key parameters are presented and their effect on hadron magnets in term of field quality and operational margins are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of CLIQ on Training of HL-LHC Quadrupole Magnets

The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb 3 Sn magnets to be used in any large particle accelerator. At development stages, many Nb 3 Sn accelerator sub-scale models showed relatively slow training and MQXFA magnets were projected to have low tens of quenches before reaching operational field. Recently it was shown that dedicated capacitor-based de-vices can affect Nb 3 Sn magnet training, and it was suggested that CLIQ, a capacitor-based device intended for quench protection, can do too. Here, the present paper investigates effects on training likely induced by CLIQ, using the base fact that only half the coils in a quadrupole experience upward current modulation at quench because of capacitor discharge. The study encompasses all MQXFA production magnets trained at BNL to date. No other high-statistics data from identical magnets (series) with CLIQ protection exist so far. Implications and opportunities stemming from data analysis are discussed and conclusions drawn.

43 PARTICLE ACCELERATORS↗

Development and Test of a Large-aperture Nb3Sn Cos-theta Dipole Coil with Stress Management

The design concept of the Electron Ion Collider (EIC), which is under construction at BNL, considers adding a 2nd Interaction Region (IR) and detector to the machine after completion of the present EIC project. Recent progress with development and fabrication of large-aperture high-field magnets based on the Nb3Sn technology for the HL-LHC makes this technology interesting for the 2nd EIC IR. This paper summarizes the results of feasibility studies of large-aperture high-field Nb3Sn dipoles and quadrupoles for the 2nd EIC IR.

43 PARTICLE ACCELERATORS↗

Assessment of Training Performance, Degradation and Robustness of Paraffin-Wax Impregnated Nb 3 Sn Demonstrator Under High Magnetic Field

In the context of high-energy physics, the use of Nb 3 Sn superconducting magnets as a cost-effective and reliable technology depends on improvements in the following areas: long development and manufacturing cycles, conductor degradation after thermal cycling, long training, as well as a demonstration in accelerator magnets with a beam aperture of the full potential of modern Nb 3 Sn conductors. In short, performance, robustness, and cost are the three issues to be addressed. The Magnet Development project (MagDev) of the Swiss Accelerator Research and Technology initiative (CHART) at the Paul Scherrer Institute (PSI) aims to contribute to the solutions to each of these issues, re-thinking the manufacturing and design process. Here in our program, every innovation is to be validated by means of a panoply of fast-turnaround tools: from non-powered and powered samples and coils, tested under background field, to low-field subscale magnets and high field short prototypes. This work presents one element in this panoply of R&D vehicles: a stress-managed Nb 3 Sn coil called BigBOX, impregnated with paraffin wax, and tested, through a collaboration with the Magnet Development Program of the United States (US-MDP), in the background field of Brookhaven National Laboratory (BNL)’s common coils dipole DCC17.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Construction of a Superconducting “Direct Wind” R&D Magnet for the EIC Interaction Region

Brookhaven National Laboratory (BNL) was chosen to host the international Electron-Ion Collider (EIC), which will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV. The Interaction Region (IR) [1] requires several large aperture, relatively high field superconducting dipole and quadrupole magnets, some of which are very closely spaced.\r\nA value engineering effort is underway as part of the EIC Project to construct and test a Direct Wind magnet [2] (coil comprised of NbTi conductor deposited directly onto a support tube, in this instance tapered, and secured mechanically against Lorentz forces afterwards) to replace two Rutherford cable collared magnets. This magnet exceeds the combination of aperture, number of coil \r\nlayers, and magnetic field, as compared to existing accelerator and R&D Direct Wind magnets to date. Furthermore, construction has been completed using a newly commissioned winding machine, upgraded in anticipation of the upcoming EIC production coil fabrication. Design, analysis, construction issues, lessons learned and accomplishments to date shall be discussed, including the \r\nachieved corrections to multipoles made to successive coil layers based on warm magnetic measurements of preceding layers.

43 PARTICLE ACCELERATORS↗

A Study of a Mini-Drift GEM Tracking Detector

In this paper, a GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a 1.6 cm drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge deposited in the drift region were measured on the readout plane which allowed the reconstruction of a short vector for the track traversing the chamber. The resulting position and angle information from the vector could then be used to improve the position resolution of the detector for larger angle tracks, which deteriorates rapidly with increasing angle for conventional GEM tracking detectors using only charge centroid information. Two types of readout planes were studied. One was a COMPASS style readout plane with 400 μm pitch XY strips and the other consisted of 2 × 10 mm 2 chevron pads. The detector was studied in test beams at Fermilab and CERN, along with additional measurements in the lab, in order to determine its position and angular resolution for incident track angles up to 45 degrees. Several algorithms were studied for reconstructing the vector using the position and timing information in order to optimize the position and angular resolution of the detector for the different readout planes. Finally, applications for large angle tracking detectors at RHIC and EIC are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-526: Irradiation of Human Cell Lines Using Carbon Ions: Real Time Dosimetry Using Gaf-Chromic Film

Purpose: The purpose of this study is to investigate and quantify several factors affecting biological effects of carbon ions such as cell type, dose, energy and position where the cells are irradiated along the pristine Bragg curve. Methods: Experiments to quantify clonogenic cell survival in three human lung cancer cell lines and a fibroblast cell line were performed at the NASA Space Radiation Laboratory, BNL, Upton, USA. A system of water or media-filled T25 flasks lined up along the beam axis was designed so that the cell-containing surfaces of the flasks were placed at specific depths along the Bragg curve. Gaf-chromic films were placed between the flasks to monitor the dose distribution in the sample as soon as the irradiation was finished. Additional studies were conducted at four selected depths along the Bragg curve to obtain full cell survival dose response curves for the four cell lines. Results: The percent depth dose of the beams was determined using an ionization chamber and showed that the physical Bragg peak is at 22.5 cm water depth. However, the clonogenic cell survival data indicated that the maximum cell killing occurred at 21.5 cm. Gaf-chromic films revealed some inhomogeneity in the dose distribution on the flasks near the peak, presumably due to lack of scattering from the sides of the flasks, which might account for the differences. Depending on the cell line and radiation dose, the maximum cell killing (i.e., the greatest RBE) is at the 21.5 (the peak) or 24 cm (distal fall off) depth. Conclusion: There is a difference in biological effect along the Bragg curve of a carbon ion beam, indicating an elevated RBE at or beyond the end of the range. Gaf-chromic films are proven to be effective in monitoring the 2D irradiation pattern to the flasks. Research supported by NIH/NCI through grant no. R21 CA182259.

60 APPLIED LIFE SCIENCES↗

High-pt and jet physics from RHIC to LHC

The observation of the strong suppression of high-pt hadrons in heavy-ion collisions at the Relativistic Heavy Ion Collider (RHIC) at BNL has motivated a large experimental program using hard probes to characterize the deconfined medium created. However, what can be denoted as 'leading particle' physics accessible at RHIC presents some limitations which motivate at higher energy the study of much more penetrating objects: jets. The gain in center-of-mass energy expected at the Large Hadron Collider (LHC) at CERN will definitively improve our understanding on how the energy is lost in the system, opening a major new window of study: the physics of jets on an event-by-event basis. We will concentrate on the expected performance for jet reconstruction in ALICE using the EMCal calorimeter.

43 PARTICLE ACCELERATORS↗

Neutron detection using a crystal ball calorimeter

The program of experiments of the A2 Collaboration performed on a beam of tagged photons of the MAMI electron microtron in Mainz (Germany) includes precision measurements of the total and differential cross sections of the pion photoproduction on neutrons of a deuterium target. The determination of the detector ability to detect neutrons is undoubtedly one of the important problems of the experiment. The calorimetric system of the detector contains a segmented NaI Crystal Ball detector, which gives information about the position, energy, and detection time of neutral and charged particles in a wide angular range. In this work, we describe the measurement of the neutron detection efficiency in the energy range from 20 to 400MeV. The results are compared with BNL data obtained on a pion beam and proton target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗