A Hybrid Reflective/Refractive/Diffractive Achromatic Fiber-Coupled Radiation Resistant Imaging System for Use in the Spallation Neutron Source (SNS)

A fiber-coupled imaging system for monitoring the proton beam profile on the target of the Spallation Neutron Source was developed using reflective, refractive and diffractive optics to focus an image onto a fiber optic imaging bundle. The imaging system monitors the light output from a chromium-doped aluminum oxide (Al{sub 2}0{sub 3}:Cr) scintillator on the nose of the target. Metal optics are used to relay the image to the lenses that focus the image onto the fiber. The material choices for the lenses and fiber were limited to high-purity fused silica, due to the anticipated radiation dose of 10{sup 8} R. In the first generation system (which had no diffractive elements), radiation damage to the scintillator on the nose of the target significantly broadened the normally monochromatic (694 nm) spectrum. This created the need for an achromatic design in the second generation system. This was achieved through the addition of a diffractive optic for chromatic correction. An overview of the target imaging system and its performance, with particular emphasis on the design and testing of a hybrid refractive/diffractive high-purity fused silica imaging triplet, is presented.

36 MATERIALS SCIENCE↗

Angle performance on optima MDxt

Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).

43 PARTICLE ACCELERATORS↗

Results of the first implementation of RF phase signature matching at LANSCE

The LINAC at the Los Alamos Neutron Science Center (LANSCE) has been utilizing the Delta-t method to match the RF cavities to the design acceleration parameters since its commissioning in 1972. The differences in time-of-flight between two subsequent Beam Position and Phase Monitors (BPPMs) are measured with both accelerated and drifting beams, depending on the whether the module is set to on or off. The algorithm optimizes the module amplitude and phase via iterative measurements if the initial phase is in the vicinity of the design value. With an upgrade to a faster readout system, a scan over the whole RF cavity phase range requires relatively less time than the classical optimization procedure. The Phase Scan Signature Matching (PSSM) method provides a time-efficient method that ensures the phase selection lands on the bunching side and empowers future analyses to build module-specific models. The PSSM also utilizes a direct model to determine the correct amplitude to sub-percent level instead of using linearized matrices. Furthermore, lacking a reliable energy measurement method in the LINAC, we measure the beam phases at two downstream locations to increase the precision of energy measurements. In this letter, we also discuss the sensitivities of PSSM, error propagation, and the implementation results for the 2019 and 2020 beam cycles.

47 OTHER INSTRUMENTATION↗

Bigelow Expandable Activity Module (BEAM) - ISS Inflatable Module Technology Demonstration

INNOVATION: BEAM is a pathway project demonstrating the design, fabrication, test, certification, integration, operation, on‐orbit performance, and disposal of the first ever man‐rated space inflatable structure. The groundwork laid through the BEAM project will support developing and launching a larger inflatable space structure with even greater mass per volume (M/V) advantages need for longer space missions. OVERVIEW: Inflatable structures have been shown to have much lower mass per volume ratios (M/V) when compared with conventional space structures. BEAM is an expandable structure, launched in a packed state, and then expanded once on orbit. It is a temporary experimental module to be used for gathering structural, thermal, and radiation data while on orbit. BEAM will be launched on Space X‐8, be extracted from the dragon trunk, and will attach to ISS at Node 3‐ Aft. BEAM performance will be monitored over a two‐year period and then BEAM will be jettison using the SSRMS.

Dasgupta, Rajib↗

In situ monitoring of material processing by a pulsed laser beam coupled via a lensed fiber into a scanning electron microscope

In this study, a new method coupling laser irradiation into a dual-beam scanning electron microscope (SEM) and focused-ion-beam (FIB) system is developed. By using a lensed fiber, pulsed laser illumination could be successfully delivered onto the sample under SEM imaging, providing in situ monitoring for laser material processing applications including local modification of micro-/nanostructures and laser-assisted chemical vapor deposition. In situ characterization of the laser-induced features by high resolution SEM imaging and energy dispersive x-ray spectrometry was successfully carried out. Furthermore, in situ repair of a contaminated lensed fiber probe during laser-assisted chemical vapor deposition was demonstrated via FIB milling. The results demonstrate the full compatibility of the lensed fiber apparatus with the dual-beam apparatus without disturbing the original functions of the system. The combination of guided laser radiation with SEM and FIB instruments offers a powerful capability for in situ monitoring of multilevel laser-based micro- and nanoscale material processing.

36 MATERIALS SCIENCE↗

Precise polarization measurements via detection of compton scattered electrons

The Qweak experiment at Jefferson Lab aims to make a 4% measurement of the parity-violating asymmetry in elastic scattering at very low Q{sup 2} of a longitudinally polarized electron beam off a proton target. One of the dominant experimental systematic uncertainties in Qweak will result from determining the beam polarization. A new Compton polarimeter was installed in the fall of 2010 to provide a non-invasive and continuous monitoring of the electron beam polarization in Hall C at Jefferson Lab. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. We have achieved the design goals of <1% statistical uncertainty per hour and expect to achieve <1% systematic uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design for a Longitudinal Density Monitor for the LHC

Synchrotron radiation is currently used on the LHC for beam imaging and for monitoring the proton population in the 3 microsecond abort gap. In addition to these existing detectors, a study has been initiated to provide longitudinal density profiles of the LHC beams with a high dynamic range and a 50ps time resolution. This would allow for the precise measurement both of the bunch shape and the number of particles in the bunch tail or drifting into ghost bunches. A solution is proposed based on counting synchrotron light photons with two fast avalanche photo-diodes (APD) operated in Geiger mode. One is free-running but heavily attenuated and can be used to measure the core of the bunch. The other is much more sensitive, for measurement of the bunch tails, but must be gated off during the passage of the bunch to prevent the detector from being swamped. An algorithm is then applied to combine the two measurements and correct for the detector dead-time, afterpulsing and pile-up effects. Initial results from laboratory testing of this system are described here.

43 PARTICLE ACCELERATORS↗

SU-E-T-263: Development of Dose Monitor Unit Calculation Using Clarkson Integration for Proton Beam Therapy Using Beam-Wobbling System

Purpose: The purpose of the present study is to develop a calculation method of dose-calibration-factor using Clarkson integration for proton therapy employing the wobbling system and to evaluate accuracy of the calculation by comparison between calculations and measurements. Methods: CF and CALF stand for a dose-calibration-factor and a dose per monitor unit (MU), respectively. A measured dose-calibration-factor CFmeas is defined as a ratio of the measured dose per monitor unit in a patient-specific condition CALFpat to the measured dose per MU in a reference beam condition CALFref. The CFcalc is a product of three factors: CF1, CF2 and CF3. The CF1 and CF2 are a factor reflecting the effect of common beam delivery devices and that of patient specific devices and parameter (an aperture collimator, a range compensator and an air gap), respectively. The CF1 was obtained by interpolation using measured data. The CF2 was calculated using the Simplified Monte Carlo (SMC) method. The SMC method calculates a dose distribution by tracing individual protons and by using a measured Bragg curve in water. The CF3 representing the correction factor of field size effect was obtained by using the Clarkson integration. We compared the calculated and measured CF values for 20 prostate cases. Results: Field size correction was found to be important. The calculations reproduce the measurement results within an error of ±2.0%, except for a few cases. The error was about –3.1% for the small field area of less than19 square centimeters. Conclusion: We have developed a calculation method of dose-calibration-factor. Calculations agreed with measurements within ±2.0% for 90% of 20 prostate cases. Except for a small field size cases, the calculation method can be applied to determine the dose-calibration–factor for majority cases of prostate cancer.

60 APPLIED LIFE SCIENCES↗

Synchrotron Radiation Beam Diagnostics at IOTA - Commissioning Performance and Upgrade Efforts

The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. A key part of its beam diagnostics suite are synchrotron radiation monitors, used for measuring transverse beam profile, position, and intensity. In this paper, we report on the performance and uses of this system during the year 1 run. We demonstrate sub-100nm statistical beam position uncertainty and high dynamic range from 10⁹ electrons down to a single electron. Commissioning challenges and operational issues are discussed. We conclude by outlining current upgrade efforts, including improved modularity, small emittance measurements, and a multi-anode photomultiplier system for turn-by-turn acquisition.

43 PARTICLE ACCELERATORS↗

Vibration energy harvesting in a small channel fluid flow using piezoelectric transducer

This work is aimed at developing a way to harvest energy from a fluid stream with the application of piezoelectric transducers in a small channel. In this COMSOL Multiphysics based simulation study, it is attempted to harvest energy from the abundant renewable source of energy available in the form of kinetic energy of naturally occurring flow of fluids. The strategy involves harnessing energy from a fluid-actuator through generation of couples, eddies and vortices, resulting from the stagnation and separation of flow around a semi-circular bluff-body attached to a cantilever beam containing a piezoceramic layer. Fluctuation of fluidic pressure impulse on the beam due to vortex shedding and varying lift forces causes the flexible cantilever beam to oscillate in the direction normal to the fluid flow in a periodic manner. The periodic application and release of a mechanical strain upon the beam effected a generation of electric potential within the piezoelectric layer, thus enabling extraction of electrical energy from the kinetic energy of the fluid. The piezoelectric material properties and transducer design are kept unchanged throughout the study, whereas the configuration is tested with different fluids and varying flow characteristics. The size and geometry of the obstructing entity are systematically varied to closely inspect the output from different iterations and for finding the optimum design parameters. The intermittent changes in the generated forces and subsequent variation in the strain on the beam are also monitored to find definitive relationship with the electrical energy output.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Helical Tomotherapy Versus Single-Arc Intensity-Modulated Arc Therapy: A Collaborative Dosimetric Comparison Between Two Institutions

Purpose: Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. Methods and Materials: Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. Results: For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. Conclusions: Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of the Sun on Remote Sensing of Sea Surface Salinity from Space

The sun is a sufficiently strong source of radiation at L-band to be an important source of interference for radiometers on future satellite missions such as SMOS, Aquarius, and Hydros designed to monitor soil moisture and sea surface salinity. Radiation from the sun can impact passive remote sensing systems in several ways, including line-of-sight radiation that comes directly from the sun and enters through antenna side lobes and radiation that is reflected from the surface to the radiometer. Examples are presented in the case of Aquarius, a pushbroom radiometer with three beams designed to monitor sea surface salinity. Near solar minimum, solar contamination is not a problem unless the sun enters near the main beam. But near solar maximum, contamination from the sun equivalent to a change of salinity on the order of 0.1 psu can occur even when the signal enters in sidelobes far from the main beam.

COMPONENT REPORTS↗

Expected Performance of the LHC Synchrotron-Light Telescope (BSRT) and Abort-Gap Monitor (BSRA)

This Report presents calculations of the synchrotron light from proton and lead-ion beams in the LHC at all energies from 0.45 to 7 TeV. It computes the emission from three sources: the uniform-field region of the D3 dipole, the dipole's edge field, and the short undulator just upstream. Light emitted at or near visible wavelengths is assessed for making optical measurements of transverse beam profiles and for monitoring the emptiness of the abort gap in the fill pattern. There is sufficient light for both applications, although both species pass through energy ranges in the ramp with small photon counts. Effects limiting image resolution are examined, including geometric optics, depth of field, and diffraction. The Report also considers recent suggestions that the undulator, intended to supplement the dipole for low energies, should not be ramped off at high energies and perhaps should not be used at all. We conclude that the undulator is essential at low energy for both species, but that it is possible to leave the undulator on at the cost of some blurring at intermediate energies.

43 PARTICLE ACCELERATORS↗

Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP

As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita et al.[Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010)]. Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.

43 PARTICLE ACCELERATORS↗

WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation show evidence of a persistent global inflammatory response that can be detected using {sup 18}F-FDG PET imaging. This work was supported through the Translational Breast Cancer Studentship award, funded in part by the Breast Cancer Society of Canada. Additional financial support is provided by the London Regional Cancer Program Catalyst Grant and the Thames Valley Veterinary Services.

60 APPLIED LIFE SCIENCES↗

Dynamic characterization, monitoring and control of rotating flexible beam-mass structures via piezo-embedded techniques

A variational principle and a finite element discretization technique were used to derive the dynamic equations for a high speed rotating flexible beam-mass system embedded with piezo-electric materials. The dynamic equation thus obtained allows the development of finite element models which accommodate both the original structural element and the piezoelectric element. The solutions of finite element models provide system dynamics needed to design a sensing system. The characterization of gyroscopic effect and damping capacity of smart rotating devices are addressed. Several simulation examples are presented to validate the analytical solution.

Lai, Steven H.-Y.↗

LHC Abort Gap Monitoring and Cleaning

Unbunched beam is a potentially serious issue in the LHC as it may quench the superconductingmagnets during a beam abort. Unbunched particles, either not captured by the RF system at injection or leaking out of the RF bucket, will be removed by using the existing damper kickers to excite resonantly the particles in the abort gap. Following beam simulations, a strategy for cleaning the abort gap at different energieswas proposed. The plans for the commissioning of the beam abort gap cleaning are described and first results from the beam commissioning are presented.

43 PARTICLE ACCELERATORS↗