Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The design of the electron beam dump unit of Turkish Accelerator Center (TAC)

The required simulations of the electron beam interactions for the design of electron beam dump unit for an accelerator which will operate to get two Infra-Red Free Electron Lasers (IR-FEL) covering the range of 3-250 microns is presented in this work. Simulations have been carried out to understand the interactions of a bulk of specially shaped of four different and widely used materials for the dump materials for a 77 pC, 40 MeV, 13 MHz repetition rate e-beam. In the simulation studies dump materials are chosen to absorb the 99% of the beam energy and to restrict the radio-isotope production in the bulk of the dump. A Lead shielding also designed around the dump core to prevent the leakage out of the all the emitted secondary radiations, e.g., neutrons, photons. The necessary dump material requirements, for the overall design considerations and the possible radiation originated effects on the dump unit, are discussed and presented.

07 ISOTOPE AND RADIATION SOURCES↗

Features Of The J-PARC Linac

Japan Proton Accelerator Research Complex (J-PARC) will be one of the highest intensity proton accelerators in the world aiming to realize 1 MW class of the beam power. The accelerator consists of a 400-MeV linac, a 3-GeV rapid-cycling synchrotron (RCS) and a main ring synchrotron (MR), and the accelerated beam is applied to several experimental facilities. The linac, which is the injector for the RCS, has about 50 cavity modules to accelerate the beam up to 400 MeV. The acceleration field error in all of them should be within {+-}1% in amplitude and {+-}1 degree in phase because the momentum spread of the RCS injection beam is required to be within 0.1%. For the cavity field stabilization, a high-stable optical signal distribution system is used as the RF reference, and sophisticated digital feedback and feed-forward system is working well in the low level RF control system. Consequently the providing beam to the RCS is very stable, and the beam commissioning and the experiments of the application facilities have been progressed steadily.

43 PARTICLE ACCELERATORS↗

Plasma electron contribution to beam emittance growth from Coulomb collisions in plasma-based accelerators

Coulomb collisions with background plasma can cause emittance growth in plasma accelerators. This paper extends the theory to consider collisions with not only motionless plasma ions but also plasma electrons with relativistic motion, based on the Frankel cross section. The theory is verified by particle-in-cell simulations with a Monte Carlo collision module. Further, it is shown that the electron contribution has the same amount as that of ions in linear acceleration regime and may not be negligible in nonlinear regime depending on the plasma electron density and its relativistic bulk velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Explore the possibility of accelerating polarized He-3 beam in RHIC

As the world's first high energy polarized proton collider, RHIC has made significant progresses in measuring the proton spin structure in the past decade. In order to have better understanding of the contribution of up quarks and down quarks to the proton spin structure, collisions of high energy polarized neutron beams are required. Polarized He-3 beams offer an effectiveway to provide polarized neutron beams. In this paper, we present studies of accelerating polarized He-3 in RHIC with the current dual snake configuration. Possibilities of adding two more pairs of snakes for accelerating polarized He-3 were explored. Results of six snake configuration in RHIC are also reported in the paper.

43 PARTICLE ACCELERATORS↗

HIGH POWER BEAM DUMP AND TARGET / ACCELERATOR INTERFACE PROCEDURES

Satisfying operational procedures and limits for the beam target interface is a critical concern for high power operation at spallation neutron sources. At the Oak Ridge Spallation Neutron Source (SNS) a number of protective measures are instituted to ensure that the beam position, beam size and peak intensity are within acceptable limits at the target and high power Ring Injection Dump (RID). The high power beam dump typically handles up to 50 100 kW of beam power and its setup is complicated by the fact that there are two separate beam components simultaneously directed to the dump. The beam on target is typically in the 800-1000 kW average power level, delivered in sub- s 60 Hz pulses. Setup techniques using beam measurements to quantify the beam parameters at the target and dump will be described. However, not all the instrumentation used for the setup and initial qualification is available during high power operation. Additional techniques are used to monitor the beam during high power operation to ensure the setup conditions are maintained, and these are also described.

Blokland, Willem↗

In Situ Generation of High-Energy Spin-Polarized Electrons in a Beam-Driven Plasma Wakefield Accelerator

We report that in situ generation of a high-energy, high-current, spin-polarized electron beam is an outstanding scientific challenge to the development of plasma-based accelerators for high-energy colliders. In this Letter, we show how such a spin-polarized relativistic beam can be produced by ionization injection of electrons of certain atoms with a circularly polarized laser field into a beam-driven plasma wakefield accelerator, providing a much desired one-step solution to this challenge. Using time-dependent Schrödinger equation (TDSE) simulations, we show the propensity rule of spin-dependent ionization of xenon atoms can be reversed in the strong-field multiphoton regime compared with the non-adiabatic tunneling regime, leading to high total spin polarization. Furthermore, three-dimensional particle-in-cell simulations are incorporated with TDSE simulations, providing start-to-end simulations of spin-dependent strong-field ionization of xenon atoms and subsequent trapping, acceleration, and preservation of electron spin polarization in lithium plasma. We show the generation of a high-current (0.8 kA), ultralow-normalized-emittance (~ 37 nm ), and high-energy (2.7 GeV) electron beam within just 11 cm distance, with up to ~31% net spin polarization. Higher current, energy, and net spin-polarization beams are possible by optimizing this concept, thus solving a long-standing problem facing the development of plasma accelerators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Whitepaper submitted to Snowmass21: Advanced accelerator linear collider demonstration facility at intermediate energy

It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1--100~GV/m, leading to compact acceleration structures. Over the last 10-15 years significant progress has been achieved in accelerating electron beams by ANAs. For example, the demonstration of several-GeV electron beams from laser-powered capillary discharge waveguides, as well as the proof-of-principle coupling of two accelerating structures powered by different laser pulses, has increased interest in ANAs as a viable technology to be considered for a compact, TeV-class, lepton linear collider. However, intermediate facilities are required to test the technology and demonstrate key subsystems. A 20-100 GeV center-of-mass energy ANA-based lepton collider can be a possible candidate for an intermediate facility. Apart from being a test beam facility for accelerator and detector studies, this collider will provide opportunities to study muon and proton beam acceleration, investigate charged particle interactions with extreme electromagnetic fields (relevant for beam delivery system designs and to study the physics at the interaction point), as well as precision Quantum Chromodynamics and Beyond the Standard Model physics measurements. Possible applications of this collider include the studies of $\gamma\gamma$ and $e$-ion collider designs.

43 PARTICLE ACCELERATORS↗

Parameterization of photon beam dosimetry for a linear accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modeled data, (3) the quality assurance process of a linear accelerator’s (Linac) beam characteristics, (4) the establishment of a standard data set for comparison with other data, etcetera. Parameterization of the photon beam dosimetry creates a data set that is portable and easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon beam dosimetric quantities, including percentage depth doses (PDDs), profiles, and total scatter output factors (S{sub cp}). Methods: S{sub cp}, PDDs, and profiles for different field sizes, depths, and energies were measured for a Linac using a cylindrical 3D water scanning system. All data were smoothed for the analysis and profile data were also centered, symmetrized, and geometrically scaled. The S{sub cp} data were analyzed using an exponential function. The inverse square factor was removed from the PDD data before modeling and the data were subsequently analyzed using exponential functions. For profile modeling, one halfside of the profile was divided into three regions described by exponential, sigmoid, and Gaussian equations. All of the analytical functions are field size, energy, depth, and, in the case of profiles, scan direction specific. The model’s parameters were determined using the minimal amount of measured data necessary. The model’s accuracy was evaluated via the calculation of absolute differences between the measured (processed) and calculated data in low gradient regions and distance-to-agreement analysis in high gradient regions. Finally, the results of dosimetric quantities obtained by the fitted models for a different machine were also assessed. Results: All of the differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 and 0.5 mm, respectively. The differences in the low gradient regions were 0.20% ± 0.20% (<1% for all) and 0.50% ± 0.35% (<1% for all) for PDDs and profiles, respectively. For S{sub cp} data, all of the absolute differences were less than 0.5%. Conclusions: This novel analytical model with minimum measurement requirements was proved to accurately calculate PDDs, profiles, and S{sub cp} for different field sizes, depths, and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ultrashort high quality electron beam from laser wakefield accelerator using two-step plasma density profile

In this paper, we first use the rf linac injector mechanism to generate ultrashort high quality electron beam from laser wakefield accelerator (LWFA) with two-step plasma density profile successfully. We incorporate the physics principle in the conventional rf linac injector into the LWFA by using two-step plasma density to decrease the wavelength of the wakefield in plasma. Using this mechanism, we observe a ultrashort high quality electron beam (the rms energy spread is 1.9%, and the rms bunch length is 2 fs) in the simulation. The ultrashort intense terahertz coherent radiation (200 MW, 2 fs) can be generated with the proposed laser wakefield accelerator.

43 PARTICLE ACCELERATORS↗

Laser-IORT: a laser-driven source of relativistic electrons suitable for Intra-Operative Radiation Therapy of tumors

In a recent experiment [1] a high efficiency regime of stable electron acceleration to kinetic energies ranging from 10 to 40 MeV has been achieved. The main parameters of the electron bunches are comparable with those of bunches provided by commercial Radio-Frequency based Linacs currently used in Hospitals for Intra-Operative Radiation Therapy (IORT). IORT is an emerging technique applied in operating theaters during the surgical treatment of tumors. Performances and structure of a potential laser-driven Hospital accelerator are compared in detail with the ones of several commercial devices. A number of possible advantages of the laser based technique are also discussed.

43 PARTICLE ACCELERATORS↗

A compact post-acceleration scheme for laser-generated protons

Protons generated by irradiating a thin metal foil with a high-intensitylaser have shown to posses interesting characteristics in terms of energy, emittance, current, and pulse duration. Therefore, in the near future, they might become a competitive source with respect to conventional proton sources. Previous theoretical, numerical, and experimental studies have already demonstrated efficient coupling between laser-accelerated proton beams with traditional radio frequency (RF)-based particle accelerators. These hybrid proton accelerators benefit from both the excellent properties of the laser-based source and the flexibility, reliability, and know-how of beam handling as provided by RF-based accelerator structures. In this paper, state of the art experimental results of laser-accelerated proton beams are used as input for a numerical study using compact and innovative conventional accelerator structures designed for medical applications. Results show that this compact hybrid accelerator allows even more efficient capture and acceleration of the laser-generated proton beam.

43 PARTICLE ACCELERATORS↗

Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g., diverse forms of electromagnetic emission) and difficulties (e.g., shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

43 PARTICLE ACCELERATORS↗

Ion acceleration in laser generated megatesla magnetic vortex

We report that Magnetic Vortex Acceleration (MVA) from near critical density targets is one of the promising schemes of laser-driven ion acceleration. 3D particle-in-cell simulations are used to explore a more extensive laser-target parameter space than previously reported in the literature as well as to study the laser pulse coupling to the target, the structure of the fields, and the properties of the accelerated ion beam in the MVA scheme. The efficiency of acceleration depends on the coupling of the laser energy to the self-generated channel in the target. The accelerated proton beams demonstrate a high level of collimation with achromatic angular divergence, and carry a significant amount of charge. For petawatt-class lasers, this acceleration regime provides a favorable scaling of the maximum ion energy with the laser power for the optimized interaction parameters. Lastly, the megatesla-level magnetic fields generated by the laser-driven coaxial plasma structure in the target are a prerequisite for accelerating protons to the energy of several hundred mega-electron-volts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerator Neutrinos

Neutrino beams generated by particle accelerators are essential for probing fundamental physics. This presentation will examine the creation of high-intensity, well-collimated neutrino beams, crucial for long-baseline experiments like DUNE and NOvA. These experiments are pushing proton beam power to multi-MW levels and utilizing large-scale detectors to overcome the challenge of limited event statistics. At LBNF, the DUNE experiment will rigorously test the three-neutrino flavor model and explore CP violation by analyzing oscillation signatures in high-intensity νμ(νμˉ)νμ​(νμ​ˉ​) to νe(νeˉ)νe​(νe​ˉ​) beams. We'll explore the technical complexities of beamline components, the drive towards higher beam powers, and the strategies for measuring and managing neutrino flux. The presentation will also cover advancements in neutrino beam instrumentation and efforts to enhance beam precision, which are key to achieving the next generation of multi-megawatt accelerator facilities. By reviewing past achievements and future prospects, this talk aims to provide a clear overview of the current state and future potential of neutrino beam technology.

Ganguly, Sudeshna↗

GEANT4 Application for the Simulation of the Head of a Siemens Primus Linac

The Monte Carlo simulation of the head of a Siemens Primus Linac used at Virgen Macarena Hospital (Sevilla, Spain) has been performed using the code GEANT4, version 9.2. In this work, the main features of the application built by our group are presented. They are mainly focused in the optimization of the performance of the simulation. The geometry, including the water phantom, has been entirely wrapped by a shielding volume which discards all the particles escaping far away through its walls. With this, a factor of four in the time spent by the simulation can be saved. An interface to read and write phase-space files in IAEA format has been also developed to save CPU time in our simulations. Finally, some calculations of the dose absorption in the water phantom have been done and compared with the results given by EGSnrc and with experimental data obtained for the calibration of the machine.

43 PARTICLE ACCELERATORS↗