Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Optimization of Ventilation Energy Demands and Indoor Air Quality in the ZEBRAlliance Homes

High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. Researchers have primarily addressed these two areas independently because of the assumption that their goals have to be mutually exclusive. This assumption is based on the fact that the typical mechanism to reduce the concentration of indoor air pollutants has been dilution through increased ventilation, which causes heating, ventilation and air conditioning (HVAC) units to consume more energy. High-performance homes aim to provide the essential energy end-uses (for example, water heating, refrigeration, space heating, and air conditioning) in an energy efficient manner. Given that IAQ is among these essential energy end-uses, we investigated means to optimize the concentration of indoor air pollutants and ventilation energy demands. To this end, we conducted tests in four houses located in Oak Ridge, TN, that were 11 to 20 months old, energy efficient (i.e., expected to consume 50% less energy than a house built per the 2006 International Residential Code), airtight (i.e., natural ventilation rate ~0.02 to 0.2 h -1 ), unoccupied, and unfurnished. Our evaluation consisted of identifying air pollutants of concern in these homes that could generally serve as indicators of IAQ, and conducting field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants.

formaldehyde↗

An Innovative Reactor Technology to Improve Indoor Air Quality

As residential buildings achieve tighter envelopes in order to minimize energy used for space heating and cooling, accumulation of indoor air pollutants such as volatile organic compounds (VOCs), becomes a major concern causing poor air quality and increased health risks. Current VOC removal methods include sorbents, ultraviolet photocatalytic oxidation (UVPCO), and increased ventilation, but these methods do not capture or destroy all VOCs or are prohibitively expensive to implement. TIAX's objective in this program was to develop a new VOC removal technology for residential buildings. This novel air purification technology is based on an innovative reactor and light source design along with UVPCO properties of the chosen catalyst to purify indoor air and enhance indoor air quality (IAQ). During the program we designed, fabricated and tested a prototype air purifier to demonstrate its feasibility and effectiveness. We also measured kinetics of VOC destruction on photocatalysts, providing deep insight into reactor design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Air Barriers for Residential Buildings

In this project we aimed to increase the knowledgebase on air barriers for residential buildings. To this end, we evaluated nine air barrier assemblies following a modified version of the ASTM E2357 Standard Test Method from the American Society for Testing and Materials. The assemblies included the eight air barrier types that are readily available in the US, even if some of these are currently mostly used in commercial construction. This decision was made because technologies that are utilized in the commercial sector may be adopted by residential builders in the future. We also followed ASTM Standard E283 to estimate the air leakage rates through flow paths that are typically found in walls before and after these were sealed following typical techniques. Assessed leakage paths included wall to foundation joints, as well as penetrations through air barrier systems due to PVC pipes, steel ducts, electrical outlets and brick ties. In addition to the gathered measurements, this report also includes recommendations and considerations on each of the air barrier types. Findings from this research will contribute to the improvement of construction practices that will help meet airtightness requirements set by building codes and programs that seek to reduce energy consumption in homes.

Air Barrier↗

Quantitative Assessment of Detection Frequency for the INL Ambient Air Monitoring Network

A quantitative assessment of the Idaho National Laboratory (INL) air monitoring network was performed using frequency of detection as the performance metric. The INL air monitoring network consists of 37 low-volume air samplers in 31 different locations. Twenty of the samplers are located on INL (onsite) and 17 are located off INL (offsite). Detection frequencies were calculated using both BEA and ESER laboratory minimum detectable activity (MDA) levels. The CALPUFF Lagrangian puff dispersion model, coupled with 1 year of meteorological data, was used to calculate time-integrated concentrations at sampler locations for a 1-hour release of unit activity (1 Ci) for every hour of the year. The unit-activity time-integrated concentration (TICu) values were calculated at all samplers for releases from eight INL facilities. The TICu values were then scaled and integrated for a given release quantity and release duration. All facilities modeled a ground-level release emanating either from the center of the facility or at a point where significant emissions are possible. In addition to ground-level releases, three existing stacks at the Advanced Test Reactor Complex, Idaho Nuclear Technology and Engineering Center, and Material and Fuels Complex were also modeled. Meteorological data from the 35 stations comprising the INL Mesonet network, data from the Idaho Falls Regional airport, upper air data from the Boise airport, and three-dimensional gridded data from the weather research forecasting model were used for modeling. Three representative radionuclides identified as key radionuclides in INL’s annual National Emission Standards for Hazardous Air Pollutants evaluations were considered for the frequency of detection analysis: Cs-137 (beta-gamma emitter), Pu-239 (alpha emitter), and Sr-90 (beta emitter). Source-specific release quantities were calculated for each radionuclide, such that the maximum inhalation dose at any publicly accessible sampler or the National Emission Standards for Hazardous Air Pollutants maximum exposed individual location (i.e., Frenchman’s Cabin) was no more than 0.1 mrem yr–1 (i.e., 1% of the 10 mrem yr–1 standard). Detection frequencies were calculated separately for the onsite and offsite monitoring network. As expected, detection frequencies were generally less for the offsite sampling network compared to the onsite network. Overall, the monitoring network is very effective at detecting the potential releases of Cs-137 or Sr-90 from all sources/facilities using either the ESER or BEA MDAs. The network was less effective at detecting releases of Pu-239. Maximum detection frequencies for Pu-239 using ESER MDAs ranged from 27.4 to 100% for onsite samplers and 3 to 80% for offsite samplers. Using BEA MDAs, the maximum detection frequencies for Pu-239 ranged from 2.1 to 100% for onsite samplers and 0 to 5.9% for offsite samplers. The only release that was not detected by any of the samplers under any conditions was a release of Pu-239 from the Idaho Nuclear Technology and Engineering Center main stack (CPP-708). The methodology described in this report could be used to improve sampler placement and detection frequency, provided clear performance objectives are defined.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal-Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Air. Part I: Experiments; Part II: Separate Effects Tests and Modeling

This experimental study investigates the thermal hydraulic behavior and the heat removal performance for a scaled Reactor Cavity Cooling System (RCCS) with air. A quarter-scale RCCS facility was designed and built based on a full-scale General Atomics (GA) RCCS design concept for the Modular High Temperature Gas Reactor (MHTGR). The GA RCCS is a passive cooling system that draws in air to use as the cooling fluid to remove heat radiated from the reactor pressure vessel to the air-cooled riser tubes and discharged the heated air into the atmosphere. Scaling laws were used to preserve key aspects and to maintain similarity. The scaled air RCCS facility at UW-Madison is a quarter-scale reduced length experiment housing six riser ducts that represent a 9.5° sector slice of the full-scale GA air RCCS concept. Radiant heaters were used to simulate the heat radiation from the reactor pressure vessel. The maximum power that can be achieved with the radiant heaters is 40 kW with a peak heat flux of 25 kW per meter squared. The quarter-scale RCCS was run under different heat loading cases and operated successfully. Instabilities were observed in some experiments in which one of the two exhaust ducts experienced a flow reversal for a period of time. The data and analysis presented show that the RCCS has promising potential to be a decay heat removal system during an accident scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Miniaturized Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant Heat eXchangers (HX) are an essential component of Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems, serving as the main heat transfer component. The major limiting factor to HX performance is the large airside thermal resistance. Recent literature aims at improving heat transfer performance by utilizing enhancement methods such as fins and small tube diameters; this has lead to almost exhaustive research on the microchannel HX (MCHX). The objective of this project is to develop a miniaturized air-to-refrigerant HX with at least 20% reduction in volume, material volume, and approach temperature compared to current state-of-the-art multiport flat tube designs and also be capable of production within five years. Moreover, the proposed HX’s are expected to have good water drainage and should succeed in both evaporator and condenser applications. The project leveraged Parallel-Parametrized Computational Fluid Dynamics (PPCFD) and Approximation-Assisted Optimization (AAO) techniques to perform multi-scale analysis and shape optimization with the intent of developing novel HX designs whose thermal-hydraulic performance exceeds that of state-of-the-art MCHX. Nine heat exchanger geometries were initially chosen for detailed analysis, selected from 35+ geometries which were identified in previous work at the University of Maryland, College Park. The newly developed optimization framework was exercised for three design optimization problems: (DP I) 1.0kW radiator, (DP II) 10kW radiator and (DP III) 10kW two-phase HX. DP I consisted of the design and optimization of 1.0kW air-to-water HX’s which exceeded the project requirements of 20% volume/material reduction and 20% better performance. Two prototypes for the 1.0kW HX were prototyped, tested and validated using newly-designed airside and refrigerant side test facilities. DP II, a scaled version DP I for 10kW air-to-water HX applications, also yielded optimized HX designs which met project requirements. Attempts to prototype a 10kW have presented unique manufacturing challenges, especially regarding tube blockages and structural stability. DP III comprised optimizing two-phase HX’s for a 3.0Ton capacity in a heat pump / air-conditioning unit for cooling mode application using R410A as the working fluid. The HX’s theoretically address the project requirements. System-level analysis showed the HX’s achieved up to 15% improvement in COP while also reducing overall unit charge by 30-40%. The project methodology was capable of developing HX’s which can outperform current state-of-the-art MCHX by at least 20% reduction in volume, material volume, and approach temperature. Additionally, the capability for optimization using refrigerant charge as an objective function was developed. The five-year manufacturing feasibility of the proposed HX’s was shown to have a good outlook. Successful prototyping through both conventional manufacturing methods and next generation methods such as additive manufacturing was achieved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Performance Validation of a Gaseous Air Cleaning Technology for Commercial Buildings

The U.S. Department of Energy (DOE) Building Technologies Office Commercial Building Integration group conducts evaluations of new energy efficiency technologies as part of the High Impact Technology Catalyst program. The subject of this field validation project is an air cleaning technology that removes gaseous contaminants from indoor air to reduce outdoor air ventilation requirements. Reducing the volume of outdoor air required reduces heating, ventilating, and air conditioning (HVAC) loads and can provide significant energy savings for some buildings in certain climates. The technology, called the HLR (HVAC Load Reduction), was developed by enVerid. The technology uses a solid regenerable sorbent material that was developed by DOE's National Energy Technology Laboratory and licensed to the vendor for this application. The sorbent material was originally developed to adsorb carbon dioxide (CO2); the vendor continued to develop the sorbent and the overall system so that it can also remove volatile organic compounds (including aldehydes), carbon monoxide, ozone, and particulate matter 2.5 micrometers in diameter or smaller (PM2.5) from the air. This material has low regeneration temperature requirements, and its sorption properties are unaffected by humidity levels, both of which are beneficial for building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Dispersion Modeling of Radioactive Releases During Proposed 236Z Rubble Pile Removal Activities

This report is part of the planning process for the removal of the 236Z rubble remaining as of January 1, 2018, at the Plutonium Finishing Plant (PFP) on the Hanford Site. This report documents an analysis considering standard techniques for the removal of demolition rubble. It does not document any decisions about the removal approaches. This document is intended to guide the establishment of a boundary for the application of an air monitoring regime. Atmospheric dispersion modeling using estimated release rates has been conducted to provide information on the location and levels of radioactive contamination that may be expected as the result of rubble removal activities. Hourly meteorological data collected over a 6-year period (2004–2009) were used to examine the effects of wind speed, direction, and stability on projected concentrations of contaminants in air and deposited on nearby surfaces. The source terms modeled in this report were based on the residual transuranic contamination levels that are anticipated to remain in the 236Z rubble following building demolition. The potential airborne concentrations were established using the five-factor formula from DOE-HDBK-3010 (DOE 1994) considering material-at-risk, damage ratio, airborne release fraction, respirable fraction, and leak path factor. Radioactive contamination emissions were calculated by release mechanism and rubble pile area for on-shift and off-shift activities. The emissions from the applicable sources were combined to provide emissions estimates for each day from each cleanup area. The U.S. Environmental Protection Agency’s (EPA’s) AERMOD computer code was used to estimate atmospheric dispersion and deposition of the released radioactive materials in the immediate vicinity of the planned rubble removal activities Both airborne and surface concentrations were modeled with AERMOD. Hourly derived air concentrations (DAC) were modeled for an array of receptors covering the rubble pile site and surrounding area. Peak (95th and 99th percentile) values of time-integrated air concentrations at these receptor points are derived from these hourly values, with modeling results reported as total incremental air concentrations in DAC-hours occurring over the selected time period. Total accumulated deposition amounts were also evaluated with AERMOD using the same array of receptors, with results reported as disintegrations per minute (dpm) per 100 cm2. Each rubble pile was considered in terms of its size, location, and estimated contamination levels. The modeling was based on the assumed sequence of the rubble removal activities. The results in this report are based on cleanup schedules and methods proposed by CHPRC. As of January 1, 2018, there are broadly three large rubble piles (west, footprint, and east) remaining of the 236Z Building process cell. It is assumed that the overall cleanup will require either 1) 30 days over a 6-week period, or 2) 60 days over a 12-week period. Work was assumed to be performed during 10-hour day shifts. The analysis shows that some releases of radioactive material are to be anticipated during the cleanup of the 236Z rubble piles. The modeling results presented here are closely tied to the details of how the rubble removal is to be conducted. The results indicate that for the rubble removal, the radiological exposures from the planned activities are predicted to be well below the designated limits for air and soil exposures. The cleanup of the 236Z main process cell rubble is expected to release some alpha-emitting radionuclides. However, results based on 6 years of hourly climatological data, two representative cleanup periods, realistic mitigating actions, and a bounding source term indicate that concentrations at the fence line of the PFP facilities should remain well below 12 DAC-hours/week. The results presented in this report are a reevaluation of a subset of the results presented in PNNL-20173 Rev. 4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗

Air classification of forest residue for tissue and ash separation efficiency

The goal of this Case Study was to evaluate the performance of air classification of logging residues toward meeting conversion CMAs for carbon and ash contents, as compared to the static status quo Base Case system in which the residues are first dried and then ground in a hammer mill with a 6 mm screen and fines < 1.18 mm are removed. Also considered were moisture and ash impacts on throughput and Overall Operating Effectiveness (OOE), as well as delivered feedstock cost and minimum fuel selling price (MFSP). Laboratory data on the impacts of fan speed and moisture content on the separation efficiency of soil ash, needles and bark from white wood were received from FCIC Subtask 5.2. Average throughput and energy consumption data were obtained from the Bioenergy Feedstock National User Facility (BFNUF) for the same air classifier. These data were utilized to develop the necessary response surface equations to perform throughput analysis using discrete event simulation. Because the Base Case status quo system utilizes drying prior to grinding, we modeled the Case Study with drying prior to air classification and subsequent grinding of the separated white wood to isolate the individual quality and cost impacts of air classification relative to the Base Case system. Key takeaways from this Case Study are that air classification improves the quality of the final material, but increases the production cost, especially when lights are disposed; this becomes a tradeoff between increased conversion yield and the extra cost. Removing material should be done as early in the process as possible. Each operation that occurs prior to removing the material increases the cost of the disposed material and leads to wasted energy expenditures. As processes are included or modified, the impact on monetary and energy cost should be included in the decision process. Identifying alternative uses and the associated value for material that is separated from the feedstock stream will have a significant impact on the delivered cost of the material. Although there was an increase in production cost by adding air classification, there was a resulting benefit to the MFSP when meeting or exceeding all of the conversion CMAs; this was an important finding that should be explored further with FCIC Subtask 8.3 and potentially FCIC Task 6.

09 BIOMASS FUELS↗

Iodine Air Sampling: Installation and Preliminary Results

The F-Area wetlands are a known sink for radioiodine generated at the Savannah River Site (SRS). Wastewater containing iodine-129 ( 129 I) was discharged into the F-Area Seepage Basins for disposal, but the acidity of the wastewater mobilized some of the contaminants from the basin soil through the vadose zone and into the groundwater; ultimately creating a groundwater plume that extends towards Fourmile Branch and its associated wetland areas. Dissolved radioiodine specifically has migrated to the nearby F-Area wetlands, where it persists as a contaminant of concern. Accumulation and resurfacing of 129 I in the wetlands and nearby areas creates a potential secondary source zone where changes in biogeochemical conditions could result in the release of this sequestered 129 I to the air. Monitoring data has indicated that 129 I has a seasonal behavior at several surface water stations, with high concentrations during summertime and low concentrations during wintertime. Still, it is not known which factors control the seasonal behavior of 129 I. Further, it has been reported that 129 I contributed approximately 23% to the 2019 SRS offsite air pathway dose to the representative person for that year (SRNS, 2020), but air measurements of 129 I have never been taken in the F-Area wetlands. Because air emissions of 129 I from the wetlands have never been investigated, it is not known if this could be a potential release pathway that needs to be included in the site conceptual model. To address these unknowns, the Savannah River National Laboratory (SRNL) has an applied research task to investigate whether 129 I in the wetlands is emitted to the air and, if so, whether air concentrations exhibit seasonal variation. This report presents information about the system recently installed in the F-Area wetlands for measuring 129 I, as well as analysis results for samples collected June through August 2023. Quantification of this constituent will provide a better understanding of the contribution of airborne 129 I from the F-Area wetlands to the offsite dose and better inform ongoing and future remedial actions.

54 ENVIRONMENTAL SCIENCES↗

Bench-Scale Development of a Novel Direct Air Capture Technology Using High-Capacity Structured Sorbents

The work performed under this project has resulted into development of a DAC technology utilizing a structured sorbent to capture CO 2 from ambient air with a key innovation of direct Joule heating of the sorbent for CO 2 desorption. A working SMA, fully integrated with an electrically resistive heating layer, high surface area support, and high CO 2 capacity sorbent coated onto a commercial ceramic monolithic substrate, was successfully developed and demonstrated over >200 adsorption-desorption cycles in a high-fidelity bench test unit directly using ambient air. A cordierite-based monolith was selected as a substrate owing to its high surface area, low bulk density, low heat capacity, and commercial availability. Reaction kinetics study conducted during this project led to development of a promoter for the base Na 2 CO 3 sorbent that could be incorporated into the sorbent to enhance to achieve higher CO 2 adsorption/desorption rates, greater working capacity, and reduced regeneration temperature. An accelerated aging study was conducted in a TGA to determine sorbent stability and no degradation in the sorbent performance was observed even after 250 adsorption-desorption cycles. An electrically resistive heating layer was developed with tunable electrical properties. The heating layer was coated onto the selected cordierite substrate. Aging studies performed showed the electrical properties and heating performance was stable after 500 heating and cooling cycles. The collective findings on the selected cordierite substrate, robust heating layer, promoter and sorbent selection were used to synthesize a full, 6”x6” SMA for bench-scale testing. The bench-scale DAC system was constructed to test full size SMAs using real ambient air for adsorption and joule heating for regeneration. After completing shakedown and commissioning of the 1 kg/day of CO 2 capacity DAC bench unit, an extended operation was performed to complete over 230 cycles with the full size SMA. This testing showed no observable degradation in sorbent performance. A detailed process model, TEA and LCA were developed for a conceptual 100,000 TPY CO 2 removal DAC facility. The LCA results show the net CO 2 e emissions from the DAC system are highly dependent on the electricity source. All other factors, including SMA manufacturing, materials for facility enclosure, etc., are minor cost contributors compared to the energy consumption required for CO 2 removal. With the successful development and validation of the SMA for the sustained performance for CO 2 removal from ambient air with joule heated regeneration in this project, a fully integrated 1 TPY bench-scale DAC system is currently in development with the support of DOE/FECM (DE-FE0032243). The project objective is to demonstrate the engineering design of the DAC system to produce a continuous, high purity CO 2 stream from ambient air. This project will address and validate key engineering features of the DAC system including the gas sealing mechanism and panels, enclosure and air contactor design, and automation sequence to achieve continuous CO 2 production.

42 ENGINEERING↗

Concetration and Distribution of Depleted Uranium (DU) and Beryllium (Be) in Soil and Air on Illeginni Island at Kwajalein Atoll after the Final Land-Impact Test

Re-entry vehicles on missiles launched from Vandenberg Air Force base in California re-enter at the Western Test Range, the Regan Test Site (RTS) at Kwajalein Atoll. An Environmental Assessment (EA) was written at the beginning of the program to assess potential impact of DU and Be, the major RV materials of interest from a health and environmental perspective, for both ocean and land impacts. The chemical and structural form of Be and DU in RVs is such that they are insoluble in soil water and seawater. Thus, they are not toxic to plant life on the isalnd (no soil to plant uptake.) Similarly, due to their insolubility in sea water there is no uptake of either element by fish, mollusks, shellfish, sea mammals, etc. No increase in either element has been observed in sea life around Illeginnin Island where deposition of DU and Be has occured. The critical terrestrial exposure pathway for U and Be is inhalation. Concentration of both elements in air over the test period (1989 to 2006) is lower by a factor of nearly 10,000 than the most restrictive U.S. guideline for the general public. Uranium concentrations in air are also lower by factors of 10 to 100 than concentrations of U in air in the U.S. measured by the EPA (Keith et al., 1999). U and Be concentrations in air downwind of deposition areas on Illeginni Island are essentially indistinguishable from natural background concentrations of U in air at the atolls. Thus, there are no health related issues associated with people using the island.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2009

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada Test Site (NTS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the NLVF, an NTS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from sources such as medically or commercially used radionuclides. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration of each detected radionuclide at each of these locations is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2. At any one location, if multiple radionuclides are detected, then compliance with NESHAP is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2009, the potential dose from radiological emissions to air, resulting from both current and past NTS activities, at onsite compliance monitoring stations was a maximum of 1.69 mrem/yr, well below the 10 mrem/yr dose limit. Air sampling data collected at all six critical receptor stations had average concentrations of radioactivity that were a fraction of the CL values listed in Table 2 in Appendix E of 40 CFR 61. Concentrations ranged from less than 1 percent to a maximum of 17 percent of the allowed NESHAP limit. Because the nearest member of the public resides approximately 20 kilometers from potential release points on the NTS, concentrations at this location would be only a small fraction of that measured on the NTS. The potential dose to the public from NLVF emissions was also very low at 0.000044 mrem/yr, 230,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Air Quality Changes after Implementation of Mitigation Measures during a Pandemic: A Scoping Review of Literature in the United States

Traffic-related emissions continue to be a significant source of air pollution in the United States (US) and around the globe. Evidence has shown that previous policies implemented to restrict-traffic flows have affected air pollution levels. Thus, mitigation strategies associated with the COVID-19 pandemic that modified population-level mobility patterns provide a unique opportunity to study air pollution change across the US. For instance, to slow the spread of the pandemic, state and local governments started implementing various mitigation actions, including stay-at-home directives, social distancing measures, school closures, and travel restrictions. This scoping review aimed to summarize the existing evidence about how air quality changed through mitigation practices throughout the pandemic in the US. We found 66 articles that fit our inclusion criteria. Generally, the consolidated results revealed that nitrogen dioxide (NO 2 ) and carbon monoxide (CO) decreased across the country. Studies observed mixed directions and magnitudes of change for fine and coarse particulate matter (PM 2.5 , PM 10 ), ozone (O 3 ), and sulfur dioxide (SO2). Few articles tried to explain this notable heterogeneity in air quality changes by associating contextual factors, such as mobility, traffic flow, and demographic factors. However, all studies agreed that the change in air pollution was nonuniform across the US and even varied within a city.

54 ENVIRONMENTAL SCIENCES↗

Effect of Intake Air Filter Condition on Light-Duty Gasoline Vehicles

Proper maintenance can help vehicles perform as designed, positively affecting fuel economy, emissions, and the overall drivability. This effort investigates the effect of one maintenance factor, intake air filter replacement, with primary focus on vehicle fuel economy, but also examining emissions and performance. Older studies, dealing with carbureted gasoline vehicles, have indicated that replacing a clogged or dirty air filter can improve vehicle fuel economy and conversely that a dirty air filter can be significantly detrimental to fuel economy. The effect of clogged air filters on the fuel economy, acceleration and emissions of five gasoline fueled vehicles is examined. Four of these were modern vehicles, featuring closed-loop control and ranging in model year from 2003 to 2007. Three vehicles were powered by naturally aspirated, port fuel injection (PFI) engines of differing size and cylinder configuration: an inline 4, a V6 and a V8. A turbocharged inline 4-cylinder gasoline direct injection (GDI) engine powered vehicle was the fourth modern gasoline vehicle tested. A vintage 1972 vehicle equipped with a carburetor (open-loop control) was also examined. Results reveal insignificant fuel economy and emissions sensitivity of modern vehicles to air filter condition, but measureable effects on the 1972 vehicle. All vehicles experienced a measured acceleration performance penalty with clogged intake air filters.

air filters↗

Microbial assessment of cabin air quality on commercial airliners

The microbial burdens of 69 cabin air samples collected from commercial airliners were assessed via conventional culture-dependent, and molecular-based microbial enumeration assays. Cabin air samples from each of four separate flights aboard two different carriers were collected via air-impingement. Microbial enumeration techniques targeting DNA, ATP, and endotoxin were employed to estimate total microbial burden. The total viable microbial population ranged from 0 to 3.6 x10 4 cells per 100 liters of air, as assessed by the ATP-assay. When these same samples were plated on R2A minimal medium, anywhere from 2% to 80% of these viable populations were cultivable. Five of the 29 samples examined exhibited higher cultivable counts than ATP derived viable counts, perhaps a consequence of the dormant nature (and thus lower concentration of intracellular ATP) of cells inhabiting these air cabin samples. Ribosomal RNA gene sequence analysis showed these samples to consist of a moderately diverse group of bacteria, including human pathogens. Enumeration of ribosomal genes via quantitative-PCR indicated that population densities ranged from 5 x 10 1 ' to IO 7 cells per 100 liters of air. Each of the aforementioned strategies for assessing overall microbial burden has its strengths and weaknesses; this publication serves as a testament to the power of their use in concert.

microbe↗