Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vaporizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Water vapor-nitrogen absorption at CO2 laser frequencies

The paper reports the results of a series of pressure-broadened water vapor absorption measurements at 27 CO2 laser frequencies between 935 and 1082 kaysers. Both multiple traversal cell and optoacoustic (spectrophone) techniques were utilized together with an electronically stabilized CW CO2 laser. Comparison of the results obtained by these two methods shows remarkable agreement, indicating a precision which has not been previously achieved in pressure-broadened studies of water vapor. The data of 10.59 microns substantiate the existence of the large (greater than 200) self-broadening coefficients determined in an earlier study by McCoy. In this work, the case of water vapor in N2 at a total pressure of 1 atm has been treated.

Peterson, J. C.↗

Condensation on a noncollapsing vapor bubble in a subcooled liquid

An experimental procedure is presented by which an estimate can be made of the condensation coefficient on a noncollapsing stationary vapor bubble in subcooled liquid nitrogen. The present experimental study utilizes film boiling from a thin wire to generate vapor bubbles which remain fixed to the wire at their base. A balance was established between the evaporation in the thin annular region along the wire and the condensation in the vapor bubbles.

Baumeister, K. J.↗

Water vapor as an error source in microwave geodetic systems: Background and survey of calibration techniques

Water vapor as an error source in radio interferometry systems is briefly examined. At microwave frequencies, the delay imposed by tropospheric water vapor becomes a limiting error source for high accuracy geodetic systems. The mapping of tropospheric induced errors into 'solved-for' parameters depends upon baseline length and observing strategy. Simulation analysis (and experience) indicates that in some cases, errors in estimating tropospheric delay can be magnified in their effect on baseline components. The various techniques by which tropospheric water can be estimated or measured are surveyed with particular consideration to their possible use as a calibration technique in support to very long baseline interferometry experiments. The method of remote sensing using a microwave radiometer seems to be the most effective way to provide an accurate estimate of water vapor delay.

Claflin, E. S.↗

Microwave radiometry as a tool to calibrate tropospheric water-vapor delay

Microwave radiometers were used to measure the emission line due to the water vapor molecules of atmospheric emission. Four separate field tests were completed which compared radiometers to other techniques which measure water vapor. It is shown that water vapor induced delay can be estimated with an accuracy of plus or minus 2 cm for elevation angles above 17 degrees.

Resch, G. M.↗

Vaporization of droplets in premixing chambers

Detailed measurements were made of the structures of turbulent fuel sprays vaporizing in heated airstreams. The measurements show the size dependent vaporization and dispersion of the droplets and the important influence of the large eddies in the turbulence. The measurements form a data base for the development of models of fuel spray vaporization. Two laser techniques were specially developed for the investigation. A laser tomography technique converts line-of-sight light scattering measurements into time averaged 'point' measurements of droplet size distribution and volume concentration. A laser anemometer particle sizing technique was further developed to permit accurate measurements of individual particle sizes and velocities, with backscatter collection of light. The experiments are combined with heat transfer models to analyze the performance of miniature thermocouples in liquid sprays.

Yule, A. J.↗

Remote sensing of seasonal distribution of precipitable water vapor over the oceans and the inference of boundary-layer structure

From the depth of the water vapor spectral lines in the 8-9 micron window region, measured by the Nimbus 4 Infrared Interferometer Spectrometer (IRIS) with a resolution of about 3/cm, the precipitable water vapor over the oceans is remotely sensed. In addition the IRIS spectral data in the 11-13 micron window region have been used to derive the sea surface temperature (SST). Seasonal maps of w on the oceans deduced from the spectral data reveal the dynamical influence of the large-scale atmospheric circulation. With the help of a model for the vertical distribution of water vapor, the configuration of the atmospheric boundary layer over the oceans can be inferred from these remotely sensed w and SST. The gross seasonal mean structure of the boundary layer inferred in this fashion reveals the broad areas of trade wind inversion and the convectively active areas such as the ITCZ. The derived information is in reasonable agreement with some observed climatological patterns over the oceans.

Prabhakara, C.↗

Computation of infrared cooling rates in the water vapor bands

A fast and accurate method is developed for calculating the infrared radiative terms due to water vapor - specifically, the atmospheric cooling rates. The accuracy is achieved by avoiding the constraints of band models and working directly with the absorption coefficient, which is a function of temperature and pressure as well as wavenumber. The method is based on calculation of an equivalent water vapor amount between atmospheric pressure levels and a table look-up procedure. Compared to line-by-line calculations, the present method has errors up to 4% of the maximum cooling rate. The use of a scaling factor, based on the far-wing approximation, limits the applicability of the method to the troposphere and lower stratosphere, where the line wings are responsible for most of the radiative cooling associated with water vapor.

Chou, M.-D.↗

Water recovery by catalytic treatment of urine vapor

The objective of this investigation was to demonstrate the feasibility of water recovery on a man-rated scale by the catalytic processing of untreated urine vapor. For this purpose, two catalytic systems, one capable of processing an air stream containing low urine vapor concentrations and another to process streams with high urine vapor concentrations, were designed, constructed, and tested to establish the quality of the recovered water.

Budininkas, P.↗

Refraction of microwave signals by water vapor

Tropospheric water vapor causes a refractive path length effect which is typically 5-10% of the 'dry' tropospheric effect and as large as several meters at elevation angles below 5 deg. The vertical water vapor profile is quite variable, and measurements of intensive atmospheric parameters such as temperature and humidity limited to the surface do not adequately predict the refractive effect. It is suggested that a water vapor refraction model that is a function of the amount of precipitable water alone can be successful at low elevation angles. From an extensive study of numerical ray tracings through radiosonde balloon data, such a model has been constructed. The model predicts the effect at all latitudes and elevation angles between 2 and 10 deg to an accuracy of better than 4% (11 cm at 3 deg elevation angle).

Goldfinger, A. D.↗

An Accurate Method for Computing the Absorption of Solar Radiation by Water Vapor

The method is based upon molecular line parameters and makes use of a far wing scaling approximation and k distribution approach previously applied to the computation of the infrared cooling rate due to water vapor. Taking into account the wave number dependence of the incident solar flux, the solar heating rate is computed for the entire water vapor spectrum and for individual absorption bands. The accuracy of the method is tested against line by line calculations. The method introduces a maximum error of 0.06 C/day. The method has the additional advantage over previous methods in that it can be applied to any portion of the spectral region containing the water vapor bands. The integrated absorptances and line intensities computed from the molecular line parameters were compared with laboratory measurements. The comparison reveals that, among the three different sources, absorptance is the largest for the laboratory measurements.

Chou, M. D.↗

Water vapor - The wet blanket of microwave interferometry

The various techniques that utilize microwave interferometry could be employed to determine distances of several thousand kilometers with an accuracy of 1 cm or 2 cm. Such measurements would be useful to obtain new knowledge of earth dynamics, greater insight into fundamental astronomical constants, and the ability to accurately navigate a spacecraft in interplanetary flight. There is, however, a basic problem, related to the presence of tropospheric water vapor, which has to be overcome before such measurements can be realized. Differing amounts of water vapor over the interferometer stations cause errors in the differential time of arrival which is the principal observable quantity. Approaches for overcoming this problem are considered, taking into account requirements for water vapor calibration to support interferometric techniques.

Resch, G. M.↗

Study of vapor flow into a capillary acquisition device

An analytical model was developed that prescribes the conditions for vapor flow through the window screen of a start basket. Several original submodels were developed as part of this model. The submodels interrelate such phenomena as the effect of internal evaporation of the liquid, the bubble point change of a screen in the presence of wicking, the conditions for drying out of a screen through a combination of evaporation and pressure difference, the vapor inflow rate across a wet screen as a function of pressure difference, and the effect on wicking of a difference between the static pressure of the liquid reservoir and the surrounding vapor. Most of these interrelations were verified by a series of separate effects tests, which were also used to determine certain empirical constants in the models. The equations of the model were solved numerically for typical start basket designs, and a simplified start basket was constructed to verify the predictions, using both volatile and nonvolatile test liquids. The test results verified the trends predicted by the model.

Dodge, F. T.↗

Ground-based lidar measurements of ozone, water vapor and aerosols in the lower stratosphere and troposphere

Lidar measurements of ozone and water vapor concentrations were performed during several field experiments in 1980-1981 by means of the differential absorption laser technique. Profiles up to 26 km for ozone and up to 9 km for water vapor are presented. Also, a lidar survey of aerosol layers ranging from 12 to 23 km were performed following the Mt. St. Helens major eruption (May 1980). Experiments were conducted at the CNRS lidar facility of the Haute Provence Observatory which is located in southern France (44 deg N, 5 deg E). For ozone a vertical profile is recorded in three sequences, each requiring 15 min of acquisition time. The relative accuracy is better than 5 percent at the lower altitude and falls to 20 percent at 25 km. For water vapor the time sequences are 4 min or 8 min long and the accuracy is better than 10 percent in the lower troposphere.

Flamant, P. H.↗

Diffusive-convective physical vapor transport of PbTe from a Te-rich solid source

Crystal growth of PbTe by physical vapor transport (sublimation) in a closed ampoule is governed by the vapor species in thermal equilibrium with the solid compound. Deviations from stoichiometry in the source material cause diffusion limitation of the transport rate, which can be modified by natural (gravity-driven) convection. Mass-transport experiments have been performed using Te-rich material wherein sublimation rates have been measured in order to study the effects of natural convection in diffusion-limited vapor transport. Linear velocities for both crystal growth and evaporation (back sublimation) have been measured for transport in the direction of gravity, horizontally, and opposite to gravity. The experimental results are discussed in terms of both the one-dimensional diffusive-advective model and current, more sophisticated theory which includes natural convection. There is some evidence that convection effects from radial temperature gradients and solutal density gradients have been observed.

Zoutendyk, J.↗

Broad band airborne water vapor radiometry

An infrared radiometer with a pass band of 280 to 520/cm (35.7 to 19.2 microns) is employed on the NASA Ames Research Center U-2 and C-141A aircraft in the measurement of water vapor burden in the upper troposphere and stratosphere. Coincidentally with altitude changes the water vapor mass mixing ratio is also inferred by observing the change in optical depth over a known vertical distance. Data from the December 1980 U-2 Water Vapor Exchange Experiment over the Panama Canal Zone add to the concept that overshooting cumulonimbus towers 'moisten' the lower stratosphere. The average mass mixing ratio in close proximity to or above such towers ranges from 3.5 to 5.0 parts per million above 18 km while the average background mass mixing ratio is only 2.9 parts per million. Generally the lowest background mixing ratios, averaging 2.6 parts per million occurred in the 18 to 21 km layer. For the same levels background Panama mass mixing ratios averaged from 1.0 to 3.0 parts per million higher than in middle latitudes.

Kuhn, P. M.↗

Vaporization in Comets; outbursts from Comet Schwassmann-Wachmann 1

Revised estimates are presented which show that the total mass and kinetic energy in a typical Comet P/Schassmann-Wachmann 1 outburst are lower than previously estimated, and that this mass is comparable to the mass of gas vaporized, as inferred from recent observations of CO(+) in this comet. The storage of energy suggested by many authors is therefore not neccessary. A simple equilibrium vaporization of CO2 or CO which is suddenly exposed, on a nucleus that is otherwise primarily composed of H2O, is proposed. Under these conditions, calculations of the variation of vaporization with rotational phase indicate that the mechanism can quantitatively produce outbursts of the size observed.

Cowan, J. J.↗

Method and apparatus for convection control of metallic halide vapor density in a metallic halide laser

An apparatus is disclosed in which a reservoir containing copper chloride is heated so that the copper chloride is maintained in a liquid form. The apparatus includes a means for flowing a buffer gas (which in the exemplary embodiment is neon) over the liquid copper chloride to provide a mixture of copper chloride vapor and neon above the liquid copper chloride. A conduit provides fluid communication between the reservoir containing the copper chloride vapor/neon mixture and the laser. The copper chloride vapor density in the laser is related to the liquid copper chloride temperature and the neon flow rate through the reservoir. In accordance with a further feature of the exemplary embodiment, neon is also provided directly to the laser in order to provide a further means of controlling the copper chloride vapor density in the laser.

Pivirotto, T. J.↗

Design, fabrication and testing of porous tungsten vaporizers for mercury ion thrusters

The dispersions in the characteristics, performance and reliability of vaporizers for early model 30-cm thrusters were investigated. The purpose of the paper is to explore the findings and to discuss the approaches that were taken to reduce the observed dispersion and present the results of a program which validated those approaches. The information that is presented includes porous tungsten materials specifications, a discussion of assembly procedures, and a description of a test program which screens both material and fabrication processes. There are five appendices providing additional detail in the areas of vaporizer contamination, nitrogen flow testing, bubble testing, porosimeter testing, and mercury purity. Four neutralizers, seven cathodes and five main vaporizers were successfully fabricated, tested, and operated on thrusters. Performance data from those devices is presented and indicates extremely repeatable results from using the design and fabrication procedures.

Zavesky, R.↗