Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Enabling Large Focal Plane Arrays Through Mosaic Hybridization

We have demonstrated advances in mosaic hybridization that will enable very large format far-infrared detectors. Specifically we have produced electrical detector models via mosaic hybridization yielding superconducting circuit paths by hybridizing separately fabricated sub-units onto a single detector unit. The detector model was made on a 100mm diameter wafer while four model readout quadrant chips were made from a separate 100mm wafer. The individually fabricated parts were hybridized using a flip-chip bonder to assemble the detector-readout stack. Once all of the hybridized readouts were in place, a single, large and thick silicon substrate was placed on the stack and attached with permanent epoxy to provide strength and a Coefficient of Thermal Expansion match to the silicon components underneath. Wirebond pads on the readout chips connect circuits to warm readout electronics; and were used to validate the successful superconducting electrical interconnection of the model mosaic-hybrid detector. This demonstration is directly scalable to 150 mm diameter wafers, enabling pixel areas over ten times the area currently available.

Miller, TImothy M.↗

Enabling Large Focal Plane Arrays Through Mosaic Hybridization

We have demonstrated advances in mosaic hybridization that will enable very large format far-infrared detectors. Specifically we have produced electrical detector models via mosaic hybridization yielding superconducting circuit paths by hybridizing separately fabricated sub-units onto a single detector unit. The detector model was made on a 100mm diameter wafer while four model readout quadrant chips were made from a separate 100mm wafer. The individually fabricated parts were hybridized using a flip-chip bonder to assemble the detector-readout stack. Once all of the hybridized readouts were in place, a single, large and thick silicon substrate was placed on the stack and attached with permanent epoxy to provide strength and a Coefficient of Thermal Expansion match to the silicon components underneath. Wirebond pads on the readout chips connect circuits to warm readout electronics; and were used to validate the successful superconducting electrical interconnection of the model mosaic-hybrid detector. This demonstration is directly scalable to 150 mm diameter wafers, enabling pixel areas over ten times the area currently available.

Miller, Timothy M.↗

Enabling Large Focal Plane Arrays Through Mosaic Hybridization

We have demonstrated advances in mosaic hybridization that will enable very large format far-infrared detectors. Specifically we have produced electrical detector models via mosaic hybridization yielding superconducting circuit patbs by hybridizing separately fabricated sub-units onto a single detector unit. The detector model was made on a 100mm diameter wafer while four model readout quadrant chips were made from a separate 100mm wafer. The individually fabric.ted parts were hybridized using a Suss FCI50 flip chip bonder to assemble the detector-readout stack. Once all of the hybridized readouts were in place, a single, large and thick silicon substrate was placed on the stack and attached with permanent epoxy to provide strength and a Coefficient of Thermal Expansion match to the silicon components underneath. Wirebond pads on the readout chips connect circuits to warm readout electronics; and were used to validate the successful superconducting electrical interconnection of the model mosaic-hybrid detector. This demonstration is directly scalable to 150 mm diameter wafers, enabling pixel areas over ten times the area currently available.

Miller, Timothy M.↗

Simulation and Comparison of Martian Surface Ionization Radiation

The spectrum of energetic particle radiation and corresponding doses at the surface of Mars is being characterized by the Radiation Assessment Detector (RAD), one of ten science instruments on the Mars Science Laboratory (MSL) Curiosity Rover. The time series of dose rate for the first 300 Sols after landing on Mars on August 6, 2012 is presented here. For the comparison to RAD measurements of dose rate, Martian surface ionization radiation is simulated by utilizing observed space quantities. The GCR primary radiation spectrum is calculated by using the Badhwar-O'Neill 2011 (BO11) galactic cosmic ray (GCR) model, which has been developed by utilizing all balloon and satellite GCR measurements since 1955 and the newer 1997-2012 Advanced Composition Explorer (ACE) measurements. In the BO11 model, solar modulation of the GCR primary radiation spectrum is described in terms of the international smoothed sunspot number and a time delay function. For the transport of the impingent GCR primary radiation through Mars atmosphere, a vertical distribution of atmospheric thickness at each elevation is calculated using the vertical profiles of atmospheric temperature and pressure made by Mars Global Surveyor measurements. At Gale Crater in the southern hemisphere, the seasonal variation of atmospheric thickness is accounted for the daily atmospheric pressure measurements of the MSL Rover Environmental Monitoring Station (REMS) by using low- and high-density models for cool- and warm-season, respectively. The spherically distributed atmospheric distance is traced along the slant path, and the resultant directional shielding by Martian atmosphere is coupled with Curiosity vehicle for dose estimates. We present predictions of dose rate and comparison to the RAD measurements. The simulation agrees to within +/- 20% with the RAD measurements showing clearly the variation of dose rate by heliospheric conditions, and presenting the sensitivity of dose rate by atmospheric pressure, which has been found from the RAD experiments and driven by thermal tides on Martian surface.

Kim, Myung-Hee Y.↗

The Neutron Star Interior Composition Explorer (NICER)

The Neutron Star Interior Composition Explorer (NICER) is an approved NASA Explorer Mission of Opportunity dedicated to the study of the extraordinary gravitational, electromagnetic, and nuclear‐physics environments embodied by neutron stars. Scheduled to be launched in 2016 as an International Space Station payload, NICER will explore the exotic states of matter, using rotation‐resolved spectroscopy of the thermal and non‐thermal emissions of neutron stars in the soft (0.2‐12 keV) X‐ray band. Grazing‐incidence "concentrator" optics coupled with silicon drift detectors, actively pointed for a full hemisphere of sky coverage, will provide photon‐counting spectroscopy and timing registered to GPS time and position, with high throughput and relatively low background. The NICER project plans to implement a Guest Observer Program, which includes competitively selected user targets after the first year of flight operations. I will describe NICER and discuss ideas for potential Be/X‐ray binary science.

Wilson-Hodge, Colleen A.↗

WFIRST Coronagraph Flight Performance Modeling

As it has for the past few years, numerical modeling is being used to predict the on-orbit, high-contrast imaging performance of the WFIRST coronagraph, which was recently defined to be solely a technology demonstrator. A consequence has been a realignment of modeling priorities and revised applications of modeling uncertainty factors and margins, which apply to multiple factors such as pointing and wavefront jitter, thermally-induced deformations, polarization, and aberration sensitivities. At the same time, the models have increased in fidelity as additional parameters have been added, such as time-dependent pupil shear and mid-spatial-frequency deformations of the primary and secondary mirrors, detector effects, and reaction-wheel-speed-dependent pointing and wavefront jitter.

Trauger, John↗

Terra MODIS Sees Solar Eclipses: Analysis of Reflective Solar Band Response at Multiple Radiance Levels

The MODIS imaging spectroradiometer instruments on-board NASA's Terra and Aqua satellites have 20 reflective solar bands (RSB) covering a wavelength range from 400 to 2200 nm. Radiance is calculated from processing raw signals with background, temperature, and electronic contamination corrected. Measured gain is calibrated with a fully Sunlit solar diffuser (SD) at a stable radiance level, considering a slowly changing SD reflectance degradation. These measurements provide time-dependent gain adjustment factors, and the calibration assumes a linear response for each band and detector. Hence, an analysis of the dependence on different radiance levels is warranted. The MODIS design has no mechanism for varying radiance levels, except for an attenuator screen. However, it has been in static configuration for Terra since mid-2003. An external source of radiance attenuation can be utilized during solar eclipse events, while maintaining high stability and accuracy of solar calibration standards. Due to its long mission lifetime, Terra has seen several Sun-Moon near-conjunction events when it coincides with the orbit path where the SD is directly illuminated. As of August 2020, we have identified 7 viable partial solar eclipses in the Terra mission data. We will discuss several results of our study, including comparison of measured SD signal to predicted radiance reduction based on a solar disk radiance model; nominal and outlier behavior as a function of bands, detectors, and mirror-sides; and comparison with other data sets. Our main conclusion from this study is that there is no notable correlation of detector-dependent trend with radiance level for most RSB bands.

Terra↗

Progressive TDI Measurements with the PACE OCI ETU

The Plankton Aerosol Cloud ocean Ecosystem (PACE) Ocean Color Instrument (OCI) has completed the ground test program for its engineering unit (ETU) and testing of the flight unit will begin in the near future. OCIis a grating spectrometer with hyperspectral coverage from about 340 nm to 885 nm with 9 additional filtered channels in the SWIR. Two CCDs are used as detectors for the hyperspectral channels. One important operating mode of the CCDs on OCI is progressive time delay integration (or PTDI). In this mode, the charge in the CCD can be held for multiples of the nominal integration times. A series of these measurements can be made with progressively increasing multiples of the nominal integration time as the instrument scans across a uniform source. Ground testing with this operating mode on OCI ETU has shown promising results. This work will present measurements taken with the PTDI mode and the analysis of OCI ETU linearity and dynamic range

PACE↗

Adaptive Numerical Dissipative Control in High Order Schemes for Multi-D Non-Ideal MHD

The goal is to extend our adaptive numerical dissipation control in high order filter schemes and our new divergence-free methods for ideal MHD to non-ideal MHD that include viscosity and resistivity. The key idea consists of automatic detection of different flow features as distinct sensors to signal the appropriate type and amount of numerical dissipation/filter where needed and leave the rest of the region free of numerical dissipation contamination. These scheme-independent detectors are capable of distinguishing shocks/shears, flame sheets, turbulent fluctuations and spurious high-frequency oscillations. The detection algorithm is based on an artificial compression method (ACM) (for shocks/shears), and redundant multi-resolution wavelets (WAV) (for the above types of flow feature). These filter approaches also provide a natural and efficient way for the minimization of Div(B) numerical error. The filter scheme consists of spatially sixth order or higher non-dissipative spatial difference operators as the base scheme for the inviscid flux derivatives. If necessary, a small amount of high order linear dissipation is used to remove spurious high frequency oscillations. For example, an eighth-order centered linear dissipation (AD8) might be included in conjunction with a spatially sixth-order base scheme. The inviscid difference operator is applied twice for the viscous flux derivatives. After the completion of a full time step of the base scheme step, the solution is adaptively filtered by the product of a 'flow detector' and the 'nonlinear dissipative portion' of a high-resolution shock-capturing scheme. In addition, the scheme independent wavelet flow detector can be used in conjunction with spatially compact, spectral or spectral element type of base schemes. The ACM and wavelet filter schemes using the dissipative portion of a second-order shock-capturing scheme with sixth-order spatial central base scheme for both the inviscid and viscous MHD flux derivatives and a fourth-order Runge-Kutta method are denoted.

Yee, H. C.↗

Hard X-ray delays

High time resolution hard X-ray rates with good counting statistics over 5 energy intervals were obtained using a large area balloon-borne scintillation detector during the 27 June 1980 solar flare. The impulsive phase of the flare was comprised of a series of major bursts of several to several tens of seconds long. Superimposed on these longer bursts are numerous smaller approximately 0.5 to 1.0 second spikes. The time profiles for different energies were cross-correlated for the major bursts. The rapid burst decay rates and the simultaneous peaks below 120 keV both indicate a rapid electron energy loss process. Thus, the flux profiles reflect the electron acceleration/injection process. The fast rate data was obtained by a burst memory in 8 and 32 msec resolution over the entire main impulsive phase. These rates will be cross-correlated to look for short time delays and to find rapid fluctuations. However, a cursory examination shows that almost all fluctuations, down to the 5% level, were resolved with 256 msec bins.

Schwartz, Richard A.↗

SIM spectral characteristics and accuracy analysis

The Space Interferometry Mission (SIM) will perform global astrometry (full sky), local wide-angle (15 degree) and narrow-angle (1 degree) observations to search extra-solar planets, and can calibrate stellar and galactic evolution theories. The astrometric accuracy of the SIM mission depends on spectral characteristics of the optics, detectors and targets. This paper will discuss the photometric throughput of the SIM instrument, and analyze effects of wavefront errors, optical mismatches and control biases as a function of wavelength. The color dependence models of the instrument optics including mirrors, lenses, field-stop and beam-splitter are presented. The performances of different detectors with a variety of coatings are compared. A model of the SIM fringe spectrometer is created. For early and late types of stars, brightness dependency errors are analyzed for different combinations of optics and detectors. Visibility loss due to imperfect optics is investigated in detail. Based on the models of instrument and estimated visibilities, the astrometric accuracies for various kinds of stars are evaluated. It is important to emphasize that not only light sources, mirrors, lenses, field stop and detectors are all wavelength dependent, but also fringe visibility loss, wavefront error, optics control error, etc. are all a function of wavelengths. For the first time the estimate of SIM performance is based on spectral analysis of all factors above, rather than monochromatic approximations of detected fringes, or simply adopted constants. This paper summarizes the astrometric accuracies for a wide range of stars and various combinations of optical design and detector configurations. It has been verified that SIM has astrometric accuracy of about 4 μas for targets with different spectra.

Shao, Michael↗

Electron-bombarded CCD detectors for ultraviolet atmospheric remote sensing

Electronic image sensors based on charge coupled devices operated in electron-bombarded mode, yielding real-time, remote-readout, photon-limited UV imaging capability are being developed. The sensors also incorporate fast-focal-ratio Schmidt optics and opaque photocathodes, giving nearly the ultimate possible diffuse-source sensitivity. They can be used for direct imagery of atmospheric emission phenomena, and for imaging spectrography with moderate spatial and spectral resolution. The current state of instrument development, laboratory results, planned future developments and proposed applications of the sensors in space flight instrumentation is described.

Carruthers, G. R.↗

Performance optimization of detector electronics for millimeter laser ranging

The front-end electronic circuitry plays a fundamental role in determining the performance actually obtained from ultrafast and highly sensitive photodetectors. We deal here with electronic problems met working with microchannel plate photomultipliers (MCP-PMTs) and single photon avalanche diodes (SPADs) for detecting single optical photons and measuring their arrival time with picosecond resolution. The performance of available fast circuits is critically analyzed. Criteria for selecting the most suitable electronics are derived and solutions for exploiting the detector performance are presented and discussed.

Cova, Sergio↗

Time and energy dependence of the cosmic ray gradient in the outer heliosphere

Pioneers 10 and 11, now 35 and 18 AU from the Sun, continue to extend our knowledge of the spatial dependence of cosmic ray intensities in the heliosphere. Radial gradients measured from these spacecraft by UCSD detectors which have integral energy responses above thresholds of 80 and 500 MeV/nucleon are reported. An average gradient of 2%/AU typifies the data set as a whole, but there are time and energy dependences that deviate from this value. With operating lifetimes of 13 and 12 years, respectively, for the two spacecraft, the time dependence was followed for over a solar cycle. The higher energy channel shows less modulation on all time scales. At the start of the present cycle, the gradient is lower than the average value during the last solar cycle.

Fillius, W.↗

Shower disc sampling and the angular resolution of gamma-ray shower detectors

As part of the design study for the new UHE gamma ray detector being constsructed at Haverah Park, a series of experiments using scintillators operated side-by-side in 10 to the 15th power eV air showers are undertaken. Investigation of the rms sampling fluctuations in the shower disc arrival time yields an upper limit to the intrinsic sampling uncertainty, sigma sub rms = (1.1 + or - 0.1)ns, implying an angular resolution capability 1 deg for an inter-detector spacing of approximately 25 m.

Lambert, A.↗

The convection electric field model for the magnetosphere based on Explorer 45 observations

Large-scale electric fields in the magnetosphere, represented by the scalar potentials of corotation and convection fields, are examined in order to interpret both plasmapause positions at different local times and energetic particle penetrations inside the plasmapause observed by the Explorer 45 (S3-A) dc E field measurements and particle detectors. The Volland-Stern type convection electric field is assumed. A uniform dawn-dusk convection electric field which corresponds to an exponent (gamma) of unity is not consistent with the observational data, but the Volland-Stern model with gamma = 2 more likely represents the convection electric field during the hours of electric field increases during magnetic activity. In the time-independent case, the shape of the plasmapause does not depend on the intensity of the convection electric field, so that by using two plasmapause distances at different local times along the S3 outbound and inbound orbits the shape factor gamma of the convection field could be determined. The average value of gamma for 42 cases was found to be 2.4.

Ejiri, M.↗

GEOS Instrument of Opportunity (IoO)

NOAA's three-axis stabilized series of GOES satellites have a place reserved on the Earth-facing side for an Instrument of Opportunity (IoO). The IoO slot is a location for new technologies that provide space-time-spectral resolution of the environment not possible with the preconceived Imager and Sounder. For example, candidate IoO's have usually proposed to use large-format staring arrays of detectors. The size, weight, power, data rate, and interface allocations for the IoO are modest in comparison to the Imager and Sounder, but the resources are large enough to allow for the collection of useful real time data. Because, the geosynchronous location is ideal for monitoring rapidly changing unpredictable events, IoO's have been suggested to detect lightning, volcanism, ozone and sulfur dioxide, ocean color, vegetation, special weather events, and even broadcast color TV. To become an IoO on GOES, the proposed instrument must: 1) have potential benefit to NOAA, 2) fit within the allocation constraints, 3) be independently funded, including pre-launch test equipment and the spacecraft accommodation costs, 4) be delivered two years before launch for integration and testing, and 5) not interfere with the existing launch schedule or the operational instruments.

Chesters, Dennis↗

Spaceflight KID Readout Electronics Development for PRIMA

We present the design and testing of spaceflight multiplexing kinetic inductance detector (KID) readout electronics for the PRobe far-Infrared Mission for Astrophysics (PRIMA). PRIMA is a mission proposed to the 2023 NASA Astrophysics Probe Explorer (APEX) Announcement of Opportunity that will answer fundamental questions about the formation of planetary systems, as well as the formation and evolution of stars, supermassive black holes, and dust over cosmic time. The readout electronics for PRIMA must be compatible with operation at Earth-Sun L2 and capable of multiplexing more than 1000 detectors over 2 GHz bandwidth while consuming around 30 W per readout chain. The electronics must also be capable of switching between the two instruments, which have different readout bands,: the hyperspectral imager (PRIMAger, 2.5-5.0 GHz) and the spectrometer (FIRESS, 0.4-2.4 GHz). We present the driving requirements, design, and measured performance of a laboratory brassboard system.

Sumit Dahal↗