Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers

Here, in this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9–1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ~30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cooled avalanche photodiode used for photon detection

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5 to 3 times more sensitive than presently-available photomultiplier tubes (PPMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than 25 percent were obtained with detector noise levels comparable to the noise of a PMT; higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, Deborah L.↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DUNE Photon Detection System

DUNE is an underground neutrino oscillation experiment that will be performing precision measurements of the PMNS matrix to determine unambiguously the mass ordering and the leptonic CP violation. It also comprises a rich non-accelerator physics program for the detection of supernova neutrinos, nucleon decay, and BSM physics. DUNE employs a high-power neutrino beam under construction at Fermilab together with the DUNE Near Detector, and four liquid argon TPCs (Far Detector) that will be installed at the Sanford Underground Research Facility in South Dakota, 1300 km away from the neutrino source. The photon detection system (PDS) – which records the 128 nm scintillation light of argon and provides the time of interaction of the beam neutrinos in the Far Detector - is critical for studying nucleon decay and detecting Supernova Neutrino Bursts. The PDS also complements the calorimetric measurement performed by the TPC (i.e. the charge readout) and contributes to the energy calibration and time performance of the Far Detector. The article is an overview of the design of the PDS for the first DUNE far detector module, with special emphasis on VUV light trapping in a cryogenic environment, its technical challenges, and the expected physics performance. The status of the construction of the PDS and its validation in the Run II of ProtoDUNE-SP will be also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Coccolithophore Blooms in Ocean Color Satellite Imagery: a Generalized Approach for Use with Multiple Sensors

A generalized coccolithophore bloom classifier has been developed for use with ocean color imagery. The bloom classifier was developed using extracted satellite reflectance data from SeaWiFS images screened by the default bloom detection mask. In the current application, we extend the optical water type (OWT) classification scheme by adding a new coccolithophore bloom class formed from these extracted reflectances. Based on an in situ coccolithophore data set from the North Atlantic, the detection levels with the new scheme were between 1,500 and 1,800 coccolithophore cellsmL and 43,000 and 78,000 lithsmL. The detected bloom area using the OWT method was an average of 1.75 times greater than the default bloom detector based on a collection of SeaWiFS 1 km imagery. The versatility of the scheme is shown with SeaWiFS, MODIS Aqua, CZCS and MERIS imagery at the 1 km scale. The OWT scheme was applied to the daily global SeaWiFS imagery mission data set (years 19972010). Based on our results, average annual coccolithophore bloom area was more than two times greater in the southern hemisphere compared to the northern hemi- sphere with values of 2.00 106 km2 and 0.75 106 km2, respectively. The new algorithm detects larger bloom areas in the Southern Ocean compared to the default algorithm, and our revised global annual average of 2.75106 km2 is dominated by contributions from the Southern Ocean.

chlorophyll fluorescence↗

Anomaly Detection Based on Machine Learning for the CMS Electromagnetic Calorimeter Online Data Quality Monitoring

Using a semi-supervised machine learning approach we present a real-time anomaly detection system based on an autoencoder used for online data quality monitoring of the CMS electromagnetic calorimeter operating at the CERN LHC. We introduce a novel method that maximizes the anomaly detection performance making use of the time-dependence of anomalies and the spatial variations in the detector response. The autoencoder-based system efficiently detects anomalies in real time and maintains a very low false discovery rate. We validate the performance of this novel system with anomalies from LHC collision data taken in 2018 and 2022. In addition, results are presented after deploying the autoencoder-based system in the CMS online Data Quality Monitoring workflow at the beginning of LHC Run 3 resulting in the system to detect issues that were missed by the existing system.

Harilal, Abhirami [Carnegie Mellon University, Pit↗

First Time-Resolved Leader Spectra Associated With a Downward Terrestrial Gamma-Ray Flash Detected at the Telescope Array Surface Detector

Optical emissions associated with Terrestrial Gamma ray Flashes (TGFs) have recently become important subjects in space-based and ground-based observations as they can help us understand how TGFs are produced during thunderstorms. In this paper, we present the first time-resolved leader spectra of the optical component associated with a downward TGF. The TGF was observed by the Telescope Array Surface Detector (TASD) simultaneously with other lightning detectors, including a Lightning Mapping Array (LMA), an INTerFerometer (INTF), a Fast Antenna (FA), and a spectroscopic system. The spectroscopic system recorded leader spectra at 29,900 frames per second (33.44 μs time resolution), covering a spectral range from 400 to 900 nm, with 2.1 nm per pixel. The recordings of the leader spectra began 11.7 ms before the -18 kA return stroke and at a height of 2.37 km above the ground. These spectra reveal that optical emissions of singly ionized nitrogen and oxygen occur between 167 μs before and 267 μs after the TGF detection, while optical emissions of neutrals (H I, 656 nm; N I, 744 nm, and O I, 777 nm) occur right at the moment of the detection. The time-dependent spectra reveal differences in the optical emissions of lightning leaders with and without downward TGFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

STOPGAP—A time-of-flight extension for the Belle II TOP barrel PID system

The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system. Due to its mechanical design, the individual TOP modules do not overlap, leaving a gap of around 2 cm between them in the azimuthal direction. This leads to a 6%–9% drop in acceptance, depending on the track’s momentum. We propose a solution to remedy these gaps by instrumenting them with fast silicon detectors to directly measure the time-of-flight of traversing particles. We present here a simulation study discussing the performance requirements and the possible sensor technologies, and we demonstrate that such a project could be realized with novel, fast monolithic CMOS sensors, or alternatively AC-LGAD sensors, both of which are expected to reach MIP timing resolutions of down to 50 ps or better.

Hartbrich, Oskar↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral estimation of received phase in the presence of amplitude scintillation

A technique is demonstrated for obtaining the spectral parameters of the received carrier phase in the presence of carrier amplitude scintillation, by means of a digital phased locked loop. Since the random amplitude fluctuations generate time-varying loop characteristics, straightforward processing of the phase detector output does not provide accurate results. The method developed here performs a time-varying inverse filtering operation on the corrupted observables, thus recovering the original phase process and enabling accurate estimation of its underlying parameters.

Vilnrotter, V. A.↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Metallic Magnetic Calorimeters for High Precision Measurements of Calorimetric Re-187 and Ho-163 Spectra

The measurement of calorimetric spectra following atomic weak decays, beta (b) and electron capture (EC), of nuclides having a very low Q-value, can provide an impressively high sensitivity to a non-vanishing neutrino mass. The achievable sensitivity in this kind of experiments is directly connected to the performance of the used detectors. In particular an energy resolution of a few eV and a pulse formation time well below 1 microsecond are required. Low temperature Metallic Magnetic Calorimeters (MMCs) for soft X-rays have already shown an energy resolution of 2.0 eV FWHM and a pulse rise-time of about 90 ns for fully micro-fabricated detectors. We present the use of MMCs for high precision measurements of calorimetric spectra following the beta-decay of Re-187 and the EC of Ho-163. We show results obtained with detectors optimized for Re-187 and for Ho-163 experiments respectively. While the detectors equipped with superconducting Re absorbers have not yet reached the aimed performance, a first detector prototype with a Au absorber having implanted Ho-163 ions already shows excellent results. An energy resolution of 12 eV FWHM and a rise time of 90 ns were measured.

Ranitzsch, P. C.-O.↗

The suppression of charged-particle-induced noise in infrared detectors

A d.c.-coupled transimpedance amplifier/pulse suppression circuit designed to remove charged-particle-induced noise from infrared detectors is described. Noise spikes produced by single particle events are large and have short rise times, and can degrade the performance of an infrared detector in moderate radiation environments. The use of the suppression circuit improves the signal-to-noise ratio by a factor of 1.6:1, which corresponds to a reduction in required observing time by a factor of about 2.6.

Houck, J. R.↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cosmic Ray Background Rejection with Wire-Cell LArTPC Event Reconstruction in the MicroBooNE Detector

For a large liquid-argon time-projection chamber (LArTPC) operating on or near the Earth’s surface to detect neutrino interactions, the rejection of cosmogenic background is a critical and challenging task because of the large cosmic-ray flux and the long drift time of the time-projection chamber. We introduce a superior cosmic background rejection procedure based on the Wire-Cell three-dimensional (3D) event reconstruction for LArTPCs. From an initial 1:20 000 neutrino to cosmic-ray background ratio, we demonstrate these tools on data from the MicroBooNE experiment and create a high-performance generic neutrino event selection with a cosmic contamination of 14.9% (9.7%) for a visible energy region greater than O(200) MeV. The neutrino interaction selection efficiency is 80.4% and 87.6% for inclusive ν μ charged-current and ν e charged-current interactions, respectively. Here, this significantly improved performance compared with existing reconstruction algorithms marks a major milestone toward reaching the scientific goals of LArTPC neutrino oscillation experiments operating near the Earth’s surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Detection Of Flameout In A Combustor

Fuel supply shut down in time to prevent explosion. Optical flameout detector designed to signal control system of facility to cut off supply of fuel into combustion chamber if flame goes out. Combustor which optical flameout detector designed burns methane in air to provide hot gases for 8-ft high-temperature test chamber. Acoustical flameout detector for same combustor described in "Acoustical Detection of Flameout in Combustor" (LAR-14900). Fiber optic probes mounted to fuel-spray bar upstream of flame. No focusing optics used, and probes aimed across flow of gases at spot on combustion chamber wall downstream from spray bar. Arrangement enables flameout detection system to respond quickly to potential loss of flame since it detects movement of flame front away from spray bar face. Overall response time of detection system under 10 milliseconds.

Borg, Stephen E.↗

Muon energy reconstruction for applications in neutrino astronomy in the DUNE far detector

Abstract DUNE (Deep Underground Neutrino Experiment) is a proposed long-baseline neutrino oscillation experiment located in the United States. The main physics objectives of DUNE are to measure neutrino oscillations and interactions, search for nucleon decay, observe supernova neutrino bursts and beyond Standard Model (BSM) effects. The DUNE far detector will be located 4850 feet underground at the Sanford Underground Research Facility in Lead, South Dakota. It will house the world's largest liquid-argon time projection chambers (TPC). The DUNE far detector can detect high-energy leptons that arise from interactions of cosmogenic neutrinos and search for neutrinos originating from the decay of weakly-interactive massive particles (WIMPs) annihilations occurring inside the Sun. Selecting upward-going muons reduces the background from cosmic-ray muons. The muon energy is estimated from the electromagnetic showers accompanying the muon, a technique that allows energy reconstruction up to a few hundred TeV.

Instruments & Instrumentation↗