At least 973 records · Page 54

Infrared temperature maps of EHD lubrication

Technique uses an infrared detector with two specially selected infrared filters, in separately mapping the contact-surface temperature and average oil-film temperature in an elastohydrodynamic conjunction. Apparatus includes conventional four-ball bearing tester and temperature controlled lubricant system.

Sanborn, D. M.↗

Modular test system for solar collectors

Portable, recirculating-water-flow, and temperature-control device is used with solar simulator and actual sunlight to test and evaluate several solar-collector panel coatings, panel designs, and scaled-down collector subsystems. System can be pressurized to prevent boiling and allows operation above 100 degrees Centigrade.

Dolan, F. J.↗

Vector magnetometer design study: Analysis of a triaxial fluxgate sensor design demonstrates that all MAGSAT Vector Magnetometer specifications can be met

The design of the vector magnetometer selected for analysis is capable of exceeding the required accuracy of 5 gamma per vector field component. The principal elements that assure this performance level are very low power dissipation triaxial feedback coils surrounding ring core flux-gates and temperature control of the critical components of two-loop feedback electronics. An analysis of the calibration problem points to the need for improved test facilities.

Adams, D. F.↗

Preliminary design study of astronomical detector cooling system

The preliminary design of an astronomical detector cooling system for possible use in the NASA C-141 Airborne Infrared Observatory is presented. The system consists of the following elements: supercritical helium tank, Joule-Thomson supply gas conditioner, Joule-Thomson expander (JTX), optical cavity dewar, optical cavity temperature controller, adjustable J-T discharge gas pressure controller, and vacuum pump.

Norman, R. H.↗

Thermal design of the IUE hydrazine auxiliary propulsion system

The International Ultraviolet Explorer is a large astronomical observatory scheduled to be placed in a three-axis stabilized synchronous orbit in the fourth quarter of 1977. The Hydrazine Auxiliary Propulsion System (HAPS) must perform a number of spacecraft maneuvers to achieve a successful mission. This paper describes the thermal design which accomplishes temperature control between 5 and 65 C for all orbital conditions by utilizing multilayer insulation and commandable component heaters. A primary design criteria was the minimization of spacecraft power by the selective use of the solar environment. The thermal design was carefully assessed and verified in both spacecraft thermal balance and subsystem solar simulation testing.

Joseph T. Skladany↗

Improvements in microelectrophoresis apparatus

Improvements to conventional microelectrophoresis techniques can simplify and standardize clinical diagnosis of large electrically charged molecules. Improvements include special trays, tray and cell covers, membranes, and temperature controls.

Grunbaum, B. W.↗

Brazing dissimilar aluminum alloys

Dip-brazing process joins aluminum castings to aluminum sheet made from different aluminum alloy. Process includes careful cleaning, surface preparation, and temperature control. It causes minimum distortion of parts.

Dalalian, H.↗

Development of a prototype regeneration carbon dioxide absorber

A prototype regenerable carbon dioxide absorber was developed to maintain the environmental quality of the portable life support system. The absorber works on the alkali metal carbonate-bicarbonate solid-gas reaction to remove carbon dioxide from the atmosphere. The prototype sorber module was designed, fabricated, and tested at simulated extravehicular activity conditions to arrive at optimum design. The unit maintains sorber outlet concentration below 5 mm Hg. An optimization study was made with respect to heat transfer, temperature control, sorbent utilization, sorber life and regenerability, and final size of the module. Important parameters influencing the capacity of the final absorber unit were identified and recommendations for improvement were made.

Patel, P. S.↗

Advanced very high resolution radiometer

The program covered the design, construction, and test of a Breadboard Model, Engineering Model, Protoflight Model, Mechanical/Structural Model, and a Life Test Model. Special bench test and calibration equipment was also developed for use on the program. Initially, the instrument was to operate from a 906 n.mi. orbit and be thermally isolated from the spacecraft. The Breadboard Model and the Mechanical/Structural Model were designed and built to these requirements. The spacecraft altitude was changed to 450 n.mi., IFOVs and spectral characteristics were modified, and spacecraft interfaces were changed. The final spacecraft design provided a temperature-controlled Instrument Mounting Platform (IMP) to carry the AVHRR and other instruments. The design of the AVHRR was modified to these new requirements and the modifications were incorporated in the Engineering Model. The Protoflight Model and the Flight Models conform to this design.

Source record↗

Interface design considerations for terrestrial solar cell modules

The need for increased solar array electrical efficiency and reliability in the achievement of future large-scale system cost goals is discussed. The relative performance of various array module designs currently on the market is evaluated, and further design improvements are suggested. The subjects of module efficiency, temperature control, and series/parallel reliability are analyzed. Applications for various combinations of array characteristics are considered.

Ross, R. G., Jr.↗

Growth-rate periodicity of Streptomyces levoris during space flight

Streptomyces levoris provides a suitable biological test system to investigate the effects of space flight on the rhythms of vegetative and spore phase characteristics of both growth-rate periodicity and culture morphology during the pre-, in-, and post-flight periods of the Apollo-Soyuz Test Project. The objectives of the American participation were to study the effects of space flight on the biorhythms of Streptomyces levoris based on a comparison of the growth-rate periodicity of the vegetative and spore phase within each culture, to examine the possible alteration of spore morphology and development by SEM, and to compare the effects of a 12-hr phase shift on the periodic growth characteristics of this microorganism in cultures which were exchanged during the joint activities of the space flight. No uniform differences in the biorhythm of Streptomyces levoris during space flight were observed. It appears that the single most variable factor related to the experiment was the lack of temperature control for the space-flight specimens.

Rogers, T. D.↗

A mission profile life test facility

A test facility is being prepared for a 16,000 hour mission profile life test of multiple electric propulsion thrust subsystems. The facility will be capable of simultaneously operating three 2.7 kW, 30 cm mercury ion thrusters and their power processing. The facility will permit conduction of a program of long-term tests to document thruster characteristics as a function of time and operating point to allow prediction of thruster performance for any mission profile. The thruster will be tested in a 7m by 10m vacuum chamber. Each thruster will be installed in a separate lock chamber so that it can be extended into, or extracted from the main chamber without violating the vacuum integrity of the other thruster. The thrusters will exhaust into a 3m by 5m frozen mercury target. The target and an array of cryopanels to collect sputtered target material will be liquid nitrogen chilled. Power processor units will be tested in an adjacent 1.5m by 2m vacuum chamber and will be temperature controlled by simulated heat pipes.

James, E.↗

Zone-controlled resistance heater

Geodesic array of heaters powered by separate electrical supply unit and silicon controlled-rectifier (SCR) control unit produces controlled temperatures over independent zones. Arrays conform to and enclose almost any shape with close thermal coupling and are programmed to reproduce almost any desired time/temperature distribution.

Bagwell, P. R.↗

Description of the three axis low-g accelerometer package

The three axis low-g accelerometer package designed for use on the Space Processing Application Rocket (SPAR) Program is described. The package consists of the following major sections: (1) three Kearfott model 2412 accelerometers mounted in an orthogonal triad configuration on a temperature controlled, thermally isolated cube, (2) the accelerometer servoelectronics (printed circuit cards PC-6 through PC-12), and (3) the signal conditioner (printed circuit cards PC-15 and PC-16). The measurement range is 0 + or - 0.031 g with a quantization of 1.1 x 10 to the 7th power g. The package was flown successfully on six SPAR launches with the Black Brant booster. These flights provide approximately 300 s of free fall or zero-g environment.

Amalavage, A. J.↗

Microelectrophoretic apparatus and process

New gel tray and lid assemblies designed for use in conjunction with slotted electrophoretic membranes were developed to take advantage of recently improved microelectrophoretic accessories which include a multisample applicator capable of applying up to 10 samples consecutively or simultaneously, and a temperature control plate for dissipating the heat produced by electrophoresis in a gel. The trays and membranes can be marketed ready for use as electrophoretic media or impregnated with various specific substrates and dyes

Grunbaum, B. W.↗

Preparation of dielectric coating of variable dielectric constant by plasma polymerization

A plasma polymerization process for the deposition of a dielectric polymer coating on a substrate comprising disposing of the substrate in a closed reactor between two temperature controlled electrodes connected to a power supply is presented. A vacuum is maintained within the closed reactor, causing a monomer gas or gas mixture of a monomer and diluent to flow into the reactor, generating a plasma between the electrodes. The vacuum varies and controls the dielectric constant of the polymer coating being deposited by regulating the gas total and partial pressure, the electric field strength and frequency, and the current density.

Hudis, M.↗

The Voyager Spacecraft

The configuration of the Voyager spacecraft is described as well as the subsystems for power, temperature control, attitude control, and propulsion. Major features of Jupiter and Saturn including their atmospheres, surfaces, and natural satellites are discussed. The 13 onboard experiments and their scientific objectives are explained. Other aspects covered include tracking, data acquisition, and the mission control and computing center. Members of the Voyager team and subcontractors are listed.

Source record↗

Ultraviolet effects on conductive coated coverglasses

Experiments on the International Sun-Earth Explorer required that the outer surface of the spacecraft be conductive. For the solar panels this was accomplished by using solar cell coverglasses coated with indium-oxide and interconnected to ground. This paper presents results of ultraviolet tests performed as part of the overall qualification program for cell assemblies using these coverglasses. The samples were exposed under vacuum at a controlled temperature to 5000 equivalent sun hours. Coverglass transmission curves and cell assembly current-voltage curves were measured before and after the test. Observed degradations were of the order of 1 percent more for conductively coated coverglasses than for coverglasses without conductive coatings.

Bass, J. A.↗