Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial transferability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Explainable artificial intelligence relates perovskite luminescence images to current-voltage metrics

As the demand for low-cost, high-efficiency solar energy technologies grows, metal halide perovskite (MHP) solar cells have emerged as a promising candidate for next-generation photovoltaics due to their high power conversion efficiencies. However, their poor durability and issues with manufacturing consistency remain significant barriers to commercialization. In this work, we develop deep learning models to support materials characterization and provide insight into features and processes influencing performance. The models are trained using transfer learning of a pretrained model to predict relevant current-voltage (IV) metrics based on different combinations of input electroluminescence (EL) and photoluminescence (PL) images of MHP devices. We examine which image types are most informative in accurately predicting different IV metrics. Additionally, we use explainable artificial intelligence (XAI) techniques to provide insights into specific spatial features in the devices that drive differences in performance. We find that stabilized luminescence images (e.g. those collected after biasing the devices for at least 1 min) are better for predicting metrics of open-circuit voltage (by PL) and short-circuit current (by PL with EL), but that predicting fill factor and overall power output may use the time-evolution of EL images. Based on attribution masks generated by integrated gradients for each device performance metric, we further suggest different loss mechanisms associated with categories of large and small spatial defects. Overall, this case study highlights the potential applicability of XAI methodology for streamlining MHP device analysis and accelerating detailed understanding of the relationships between spatial defects and impacts on performance.

14 SOLAR ENERGY↗

AlphaFold and Structural Mass Spectrometry Enable Interrogations on the Intrinsically Disordered Regions in Cyanobacterial Light-harvesting Complex Phycobilisome

Intrinsically disordered proteins/regions (IDPRs) are a very large and functionally important class of proteins that participate in weak multivalent interactions in protein complexes. They are recalcitrant for interrogations using X-ray crystallography and cryo-EM. The IDPRs observed at the interface of the photosynthetic pigment protein complexes (PPCs) remain much less clear, e.g., the major cyanobacterial light-harvesting complex (PBS) contains an unstructured PB-loop insertion in the phycocyanobilin domain (PB domain) of ApcE (the largest polypeptide in PBS). Here, a joint platform is built to probe such structural domains. This platform is characterized by two-round progressive justifications of in silico models by using the structural mass spectrometry data. First, the AlphaFold-generated 3D structure of the PB domain (containing PB-loop) was justified in the context of PBS. Second, docking the AlphaFold-generated ApcG (a ligand) into the first-step justified structure (a receptor). The final ligand-receptor complex was then subjected to a second-round justification, again, by using unequivocal isotopically-encoded cross-links identified in LC-MS/MS. This work reveals a full-length PB-loop structure modelled in the PBS basal cylinder, free from any spatial conflicts against the other subunits in PBS. The structure of PB domain highlights the close associations of the intrinsically disordered PB-loop with its binding partners in PBS, including ApcG, another IDPR. The PB-loop region involved in the binding of photosystem II (PSII) is also discussed in the context of excitation energy transfer regulation. Finally, this work calls attention to the highly disordered, yet interrogatable interface between the light-harvesting antenna complexes and the reaction centers.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular-Scale Characterization of Photoinduced Charge Separation in Mixed-Dimensional InSe–Organic van der Waals Heterostructures

Layered indium selenide (InSe) is an emerging two-dimensional semiconductor that has shown significant promise for high-performance transistors and photodetectors. The range of optoelectronic applications for InSe can potentially be broadened by forming mixed-dimensional van der Waals heterostructures with zero-dimensional molecular systems that are widely employed in organic electronics and photovoltaics. Here, we report the spatially resolved investigation of photoinduced charge separation between InSe and two molecules (C 70 and C 8 -BTBT) using scanning tunneling microscopy combined with laser illumination. We experimentally and computationally show that InSe forms type-II and type-I heterojunctions with C 70 and C 8 -BTBT, respectively, due to an interplay of charge transfer and dielectric screening at the interface. Laser-excited scanning tunneling spectroscopy reveals a ~0.25 eV decrease in the energy of the lowest unoccupied molecular orbital of C 70 with optical illumination. Furthermore, photoluminescence spectroscopy and Kelvin probe force microscopy indicate that electron transfer from InSe to C 70 in the type-II heterojunction induces a photovoltage that quantitatively matches the observed downshift in the tunneling spectra. In contrast, no significant changes are observed upon optical illumination in the type-I heterojunction formed between InSe and C 8 -BTBT. Density functional theory calculations further show that, despite the weak coupling between the molecular species and InSe, the band alignment of these mixed-dimensional heterostructures strongly differs from the one suggested by the ionization potential and electronic affinities of the isolated components. Self-energy-corrected density functional theory indicates that these effects are the result of the combination of charge redistribution at the interface and heterogeneous dielectric screening of the electron–electron interactions in the heterostructure. In addition to providing specific insight for mixed-dimensional InSe–organic van der Waals heterostructures, this work establishes a general experimental methodology for studying localized charge transfer at the molecular scale that is applicable to other photoactive nanoscale systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Row spacing as a controller of solar module temperature and power output in solar farms

We report that when the temperature of solar photovoltaic modules rises, efficiency drops and module degradation accelerates. The spatial arrangement of solar modules can affect convective cooling and, consequently, module temperatures. However, the impact of row spacing on convective cooling in realistic solar farms has not yet been studied. Here, we develop six solar farm arrangements consisting of a fixed number of rows with varying streamwise row spacing. We model the flow and heat transfer of each solar farm using high-resolution large-eddy simulations. Results indicate that increasing row spacing can enhance convective cooling by 14.8%, which reduces module temperature by 6.6 °C and increases power output by 4.0% on average.

14 SOLAR ENERGY↗

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

A measurement of two-photon exchange in Super-Rosenbluth separations with positron beams

The proton electric and magnetic form factors, G E and G M , are intrinsically connected to the spatial distribution of charge and magnetization in the proton. For decades, Rosenbluth separation measurements of the angular dependence of elastic e--p scattering were used to extract G E and G M . More recently, polarized electron scattering measurements, aiming to improve the precision of G E extractions, showed significant disagreement with Rosenbluth measurements at large momentum transfers (Q 2 ). This discrepancy is generally attributed to neglected two-photon exchange (TPE) corrections. At larger Q 2 values, a new ‘Super-Rosenbluth’ technique was used to improve the precision of the Rosenbluth extraction, allowing for a better quantification of the discrepancy, while comparisons of e + -p and e - -p scattering indicated the presence of TPE corrections, but at Q 2 values below where a clear discrepancy is observed. Here, in this work, we demonstrate the significant benefits to combining the Super-Rosenbluth technique with positron beam measurements. This approach provides a greater kinematic reach and is insensitive to some of the key systematic uncertainties in previous positron measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation and Verification for INL Modelica-based TEDS models Via Experimental Results

This report provides an overview on the verification and validation (V&V) of the Thermal Energy Distribution System (TEDS) model developed in the Modelica process modeling ecosystem using experimental data. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Energy Systems Laboratory (ESL) at Idaho National Laboratory (INL). The model was then used during the preconstruction phase of the experimental effort to inform experimental design (e.g., insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit: a 200kW Chromalox heater; a single-tank packed-bed thermal energy storage system filled with 0.125-inch alumina (Al2O3) beads; an ethylene-glycol-to-Therminol-66 heat exchanger; system piping; five control valves; and all associated temperature, pressure, and volumetric flow sensors. Using the Institute of Electrical and Electronics Engineers (IEEE) V&V methodologies, considered the gold standard in the engineering field, the model was verified using a combination of static analysis, spatial convergence, and regression tests. Then using dynamic time warping (DTW) initial runs to validate and tune the TEDS model versus the experiment were conducted. This tuning method was accomplished using the INL Risk Analysis Virtual ENvironment (RAVEN) software package. Tuning is required to account for physical phenomena that are less understood within the empirical heat transfer correlations. Through the commencement of this work, a systems-level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model was utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Then, initial experimental startup and operational data were used to demonstrate the validation and tuning methodology. This process demonstrates the classical two-step approach of a model informing experimental design followed by the experiment validation and tuning the model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The spatial structure of terrain - A process signal in satellite digital images

Pattern recognition procedures applied to Landsat imagery carry an implicit assumption that the digital data are independently distributed. That assumption is incorrect over virtually any terrain. Deviations from independence occur because slopes follow a systematic pattern of variation arising from the slope-forming processes. That pattern can be identified using the stochastic process methodology of Box and Jenkins.Angles of adjacent slopes are autocorrelated and the bidirectional reflectance function transfers these systematic slope changes to the sensor. Imagery becomes autocorrelated through this transfer. Autocorrelation in the imagery can be removed through direct calculation from a digital elevation model or by use of stochastic process methodology. The latter has the advantage that the residuals are white noise; and it is applicable in any area, even where a D.E.M. is unavailable. The stochastic process signal can be used to study terrain processes.

Craig, R. G.↗

Evaluating Radiometric Sensitivity of LandSat 8 Over Coastal-Inland Waters

The operational Land Imager (OLI) aboard Landsat 8 was launched in February 2013 to continue the Landsat's mission of monitoring earth resources at relatively high spatial resolution. Compared to Landsat heritage sensors, OLI has an additional 443-nm band (termed coastal/aerosol (CA) band), which extends its potential for mapping/monitoring water quality in coastal/inland waters. In addition, OLI's pushbroom design allows for longer integration time and, as a result, higher signal-to-noise ratio (SNR). Using a series of radiative transfer simulations, we provide insights into the radiometric sensitivity of OLI when studying coastal/inland waters. This will address how the changes in water constituents manifest at top-of-atmosphere (TOA) and whether the changes are resolvable at TOA (focal plane) relative to OLI's overall noise.

radiometric sensitivity↗

Controlling Symmetry Breaking Charge Transfer in BODIPY Pairs

Symmetry breaking charge transfer (SBCT) is a process in which a pair of identical chromophores absorb a photon and use its energy to transfer an electron from one chromophore to the other, breaking the symmetry of the chromophore pair. This excited state phenomenon is observed in photosynthetic organisms where it enables efficient formation of separated charges that ultimately catalyze biosynthesis. SBCT has also been proposed as a means for developing photovoltaics and photocatalytic systems that operate with minimal energy loss. It is known that SBCT in both biological and artificial systems is in part made possible by the local environment in which it occurs, which can move to stabilize the asymmetric SBCT state. However, how environmental degrees of freedom act in concert with steric and structural constraints placed on a chromophore pair to dictate its ability to generate long-lived charge pairs via SBCT remain open topics of investigation. In this work we compare a broad series of dipyrrin dimers that are linked by distinct bridging groups to discern how the spatial separation and mutual orientation of linked chromophores and the structural flexibility of their linker each impact SBCT efficiency. Across this material set, we observe a general trend that SBCT is accelerated as the spatial separation between dimer chromophores decreases, consistent with the expectation that the electronic coupling between these units varies exponentially with their separation. However, one key observation is that the rate of charge recombination following SBCT was found to slow with decreasing interchromophore separation, rather than speed up. This stems from an enhancement of the dimers’ structural rigidity due to increasing steric repulsion as the length of their linker shrinks. This rigidity further inhibits charge recombination in systems where symmetry has already enforced zero HOMO-LUMO overlap. Additionally, for the forward transfer the active torsion is shown to increase LUMO-LUMO coupling, allowing for faster SBCT within bridging groups. Further, by understanding trends for how rates of SBCT and charge recombination depend on a dimer’s internal structure and their environment, we identify design guidelines for creating artificial systems for driving sustained light-induced charge separation. Such systems can find application in solar energy technologies and photocatalytic applications but can serve as a model for light-induced charge separation in biological systems.

14 SOLAR ENERGY↗

Modeling of Sub-Grid Heterogeneity and its Impact on GCM Global Radiation Balance

The spatial and temporal variability of high, low, and mid-level clouds is obtained from ISCCP D1 data. Monthly mean global maps of the observed cloud variability are used to re-scale GCM prognostic cloud optical depths and radiative parameters via the Monte Carlo cloud heterogeneity parameterization that utilizes the existing plane-parallel GCM radiative transfer model to compute radiative fluxes for inhomogeneous cloud distributions. The GCM radiative fluxes at TOA and the ground surface are then compared to ERBE and GEBA results. These comparisons show that including sub-grid cloud variability in the GCM radiative model improves agreement between the GCM radiative energy budget components and observations,

Lacis, Andrew↗

Development of a High Output Fluorescent Light Module for the Commercial Plant Biotechnology Facility

To maximize the use of available resources provided onboard the International Space Station, the development of an efficient lighting 1 system is critical to the overall performance of the CPBF. Not only is it important to efficiently generate photon energy, but thermal loads on the CPBF Temperature and Humidity Control System must be minimized. By utilizing optical coatings designed to produce highly diffuse reflectance in the visible wavelengths while minimizing reflectance in the infrared region, the design of the fluorescent light module for the CPBF is optimized for maximum photon flux, spatial uniformity and energy efficiency. Since the Fluorescent Light Module must be fully enclosed to meet (ISS) requirements for containment of particulates and toxic materials, heat removal from the lights presented some unique design challenges. By using the Express Rack moderate C, temperature-cooling loop, heat is rejected by means of a liquid/air coolant manifold. Heat transfer to the manifold is performed by conduction using copper fins, by forced air convection using miniature fans, and by radiation using optically selective coatings that absorb in the infrared wavelengths. Using this combination of heat transfer mechanisms builds in redundancy to prevent thermal build up and premature bulb failure.

Turner, Mark↗

Subgrid Combustion Modeling for the Next Generation National Combustion Code

In the first year of this research, a subgrid turbulent mixing and combustion methodology developed earlier at Georgia Tech has been provided to researchers at NASA/GRC for incorporation into the next generation National Combustion Code (called NCCLES hereafter). A key feature of this approach is that scalar mixing and combustion processes are simulated within the LES grid using a stochastic 1D model. The subgrid simulation approach recovers locally molecular diffusion and reaction kinetics exactly without requiring closure and thus, provides an attractive feature to simulate complex, highly turbulent reacting flows of interest. Data acquisition algorithms and statistical analysis strategies and routines to analyze NCCLES results have also been provided to NASA/GRC. The overall goal of this research is to systematically develop and implement LES capability into the current NCC. For this purpose, issues regarding initialization and running LES are also addressed in the collaborative effort. In parallel to this technology transfer effort (that is continuously on going), research has also been underway at Georgia Tech to enhance the LES capability to tackle more complex flows. In particular, subgrid scalar mixing and combustion method has been evaluated in three distinctly different flow field in order to demonstrate its generality: (a) Flame-Turbulence Interactions using premixed combustion, (b) Spatially evolving supersonic mixing layers, and (c) Temporal single and two-phase mixing layers. The configurations chosen are such that they can be implemented in NCCLES and used to evaluate the ability of the new code. Future development and validation will be in spray combustion in gas turbine engine and supersonic scalar mixing.

Menon, Suresh↗

Developing A Continuous Ozone Record Through the SAGE and Aura Missions With NASA Reanalysis Products

During the last quarter of the 20th century, the Stratospheric Aerosol and Gas Experiment (SAGE) missions were crucial in monitoring the loss and subsequent recovery of the stratospheric ozone layer. Due to the employed solar occultation and self-calibration method, the SAGE monitors have produced stable data throughout the lifetime of each instrument. However, over ten years passed between the end of the SAGE II and SAGE III/M3M missions in 2005 and the launch of SAGE III/ISS instrument in 2017, leaving a gap in the data that must be bridged in order to assess trends in the ozone record. The Modern-Era Retrospective analysis for Research and Applications, version 2 (MERRA-2) reanalysis product, with output available starting in 1980, is an attractive candidate for trend analysis due to the statistically optimized combination of multiple observing systems and the regular temporal and spatial coverage. However, changes in the assimilated observation systems can introduce discontinuities within the MERRA-2 ozone record, such as in 2004 when the MERRA-2 system shifted from assimilating ozone retrievals collected by SBUV instruments to those collected by instruments onboard the Aura satellite. In this study, we explore using the SAGE II record as a transfer function to develop a stable reanalysis data product, suitable for trend analysis, from the start of the SAGE II record in 1984 through the present. We follow the procedure outlined by Wargan et al. (2018) to address discontinuities in the MERRA-2 ozone dataset at the 2004 transition and during the Aura record. SAGE II ozone profiles are used to correct discontinuities in upper stratospheric ozone associated with changes in the MERRA-2 meteorological observing system in 1998 and 1995. We will then assess the relative performance of the data from different SAGE sensors using the resulting bias-corrected MERRA-2 ozone fields.

Pamela Wales↗

Operational MTF for Landsat Thematic Mapper

The Landsat Thematic Mapper (TM) represents significant improvements in spatial, spectral, and radiometric resolution over the older Multispectral Scanner System (MSS). For the last three years, NASA has conducted the Landsat Image Data Quality Analysis (LIDQA) program to quantify the performance of the TM on the Landsat-4 and 5 spacecraft. As part of this program, analysis of the TM imagery to extract the overall system modulation transfer function (MTF) has been performed. In this paper, the San Mateo Bridge in San Francisco is described as a target for calculation of the line spread function and MTF. The analysis of two TM scenes, one from 12/31/82 and one from 8/12/83, yielded effective-instantaneous-field-of-views (EIFOVs) of 40.8 meters and 48.6 meters, respectively. These values are compared with the 33.8 meter EIFOV predicted by component modelling of the TM sensor, and the differences discussed.

Schowengerdt, R.↗

Evaluation of sensible heat flux, latent heat flux, and effective aerodynamic roughness at the land surface from a combination of satellite and in-situ data

A simple method is presented for using the daytime rise of the PBL height, combined with coincident satellite skin temperature measurements, to evaluate sensible heating and the effective surface roughness for heat transfer at synoptic locations. Multiple runs of a combination surface layer-mixed layer model are made in the central U.S., varying the values of surface moisture and roughness length around climatological means, and initializing the model with a set of atmospheric conditions from the synoptic report. The results, shown in figures and tables, are quite reasonable and spatially coherent, and depict well the sharp change in surface moisture and roughness which is known to take place across the central U.S.

Diak, George R.↗

Radiometric Characterization Results for the IKONOS, Quickbird, and OrbView-3 Sensor

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities better understand commercial imaging satellite properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Applied Sciences Directorate (ASD) at Stennis Space Center established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA ASD, the University of Arizona Remote Sensing Group, and South Dakota State University. Each group independently determined the absolute radiometric calibration coefficients of available high-spatial-resolution commercial 4-band multispectral products, in the visible though near-infrared spectrum, from GeoEye(tradeMark) (formerly SpaceImaging(Registered TradeMark)) IKONOS, DigitalGlobe(Regitered TradeMark) QuickBird, and GeoEye (formerly ORBIMAGE(Registered TradeMark) OrbView. Each team member employed some variant of reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with image acquisitions and radiative transfer calculations. Several study sites throughout the United States that covered a significant portion of the sensor's dynamic range were employed. Satellite at-sensor radiance values were compared to those estimated by each independent team member to evaluate the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these sensors' absolute calibration values.

Holekamp, Kara↗