Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Surface albedo spatial variability in North America: Gridded data vs. local measurements

Considering the current booming interest for the large-scale deployment of bifacial photovoltaic modules, the solar industry now requires accurate estimates of broadband surface albedo at high spatial resolution. In this context, the present study evaluates the adequacy and performance over North America of two Moderate Resolution Imaging Spectroradiometer (MODIS) white-sky albedo products (at 500-m and 1-km resolution) and the National Solar Radiation Database (NSRDB) product at 4-km resolution. Two variations of the 500-m MODIS product are also considered: black-sky albedo and all-sky albedo. Albedo observations from 36 radiometric stations during 2011–2015 are analyzed while considering the apparent homogeneity of the surface characteristics over the 4x4 km NSRDB pixel in which they are located. Even at sites where the albedo around the station has been found “homogeneous” in the literature, marked differences are found between the daily observations and the gridded estimates at any spatial resolution. Furthermore, differences in seasonal behavior and between the three different albedo types also impact the accuracy of the albedo estimates, with overtones caused by local specificities and inhomogeneities. All this precludes the desirable evaluation of the local albedo at a specific site of relatively small size compared to its corresponding 4x4-km pixel if only the mean albedo over that pixel is known. Significant discrepancies are also found at snow-impacted sites, most importantly in the case of the NSRDB albedo estimates, which are typically much too high.

14 SOLAR ENERGY↗

Unraveling plant–microbe symbioses using single-cell and spatial transcriptomics

Plant-microbe symbioses require intense interaction and genetic coordination to successfully establish in specific cell types of the host and symbiont. Traditional RNA-seq methodologies lack the cellular resolution to fully capture these complexities, but single-cell and spatial transcriptomics (ST) are now allowing scientists to probe symbiotic interactions at an unprecedented level of detail. Here, we discuss the advantages that novel spatial and single-cell transcriptomic technologies provide in studying plant-microbe endosymbioses and highlight key recent studies. Finally, we consider the remaining limitations of applying these approaches to symbiosis research, which are mainly related to the simultaneous capture of both plant and microbial transcripts within the same cells.

59 BASIC BIOLOGICAL SCIENCES↗

Catalysts in Coronas: A Surface Spatial Confinement Strategy for High-Performance Catalysts in Methane Dry Reforming

One of the grand challenges in industrial catalytic processes is the inevitable sintering and aggregation of conventional supported catalysts to large particles, leading to the decrease of activity and even deactivation with time. Herein, a surface spatial confinement strategy was employed to design high-performing catalysts for the dry reforming of methane (DRM). Specifically, active nickel (Ni) nanoparticles (NPs) were confined on the surface of a dendritic mesoporous silica (DMS) in the form of the “catalysts in coronas”. The Ni/DMS catalyst exhibited a high catalytic performance close to its equilibrium conversion (76% conversion for CH4 at 700 °C). More importantly, the prepared catalyst remained stable after 145 h time-on-stream at 700 °C without noticeable carbon deposition. This sintering and coking resistance was found to arise from the surface spatial confinement effect in which the three-dimensional dendritic layers in the corona posted a steric barrier against migration and aggregation of Ni NPs and size of Ni NPs was controlled below 5 nm, hence against sintering and coking. Meanwhile, the mesoporous feature of the layered wall facilitated mass transport of reactants to Ni species and further boosted catalysis. This strategy should be broadly applicable to a range of metal- and metal oxide-supported catalysts in high-temperature heterogeneous reactions, such as DRM, water gas shift reaction, and vehicle emission control related reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial and Temporal Variations of Aerosols Around Beijing in the Summer 2006: Model Evaluation and Source Apportionment

Regional aerosol model calculations were made using the WRF-CMAQ and WRF-chem models to study spatial and temporal variations of aerosols around Beijing, China, in August and September 2006 when the CAREBEIJING-2006 campaign was conducted. Model calculations were compared with in-situ observations made at the urban site in Beijing and suburb site in Yufa, which is 50 km to the south of Beijing. In general, the two model calculations reproduced features of temporal variations of meteorological parameters and concentrations of elemental carbon (EC) and inorganic aerosols (sulfate, ammonium, and nitrate). Spatial distributions of aerosol optical depth (AOD) obtained by the MODIS satellite sensor are also generally well reproduced. Model calculations show that enhancements in inorganic aerosol concentrations simultaneously observed at the two sites 4 to 5 times during the one-month observation period were resulted by accumulation of pollutants under stagnated air condition. Because Beijing is located at the north border the high anthropogenic emission area (the Great North China Plain), northward motion of air under the influence of anti-cyclone system caused enhancements in fine aerosol concentrations at Beijing. Concentrations of primary aerosols, such as EC, are found to be generally controlled by emissions within 100 km around Beijing within previous 24 hours. On the other hand, emissions as far as 500 km within previous 3 days were found to affect concentrations of secondary aerosols, such as sulfate. Because of significant contributions of secondary aerosols in Beijing, regional emission controls are found to be necessary for improvement of air quality in Beijing.

54 ENVIRONMENTAL SCIENCES↗

Regional Sources of Nitrous Oxide over the United States: Seasonal Variation and Spatial Distribution

This paper presents top-down constraints on the magnitude, spatial distribution, and seasonality of nitrous oxide (N{sub 2}O) emissions over the central United States. We analyze data from tall towers in 2004 and 2008 using a high resolution Lagrangian particle dispersion model paired with both geostatistical and Bayesian inversions. Our results indicate peak N{sub 2}O emissions in June with a strong seasonal cycle. The spatial distribution of sources closely mirrors data on fertilizer application with particularly large N{sub 2}O sources over the US Cornbelt. Existing inventories for N{sub 2}O predict emissions that differ substantially from the inverse model results in both seasonal cycle and magnitude. We estimate a total annual N{sub 2}O budget over the central US of 0.9-1.2 TgN/yr and an extrapolated budget for the entire US and Canada of 2.1-2.6 TgN/yr. By this estimate, the US and Canada account for 12-15% of the total global N{sub 2}O source or 32-39% of the global anthropogenic source as reported by the Intergovernmental Panel on Climate Change in 2007.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Aerosol Dry Deposition on Black Carbon Spatial Distributions and Radiative Effects in the Community Atmosphere Model CAM5

Dry deposition is a vital process affecting the lifetime and spatial distributions of atmospheric aerosols. Black carbon (BC) plays an important role in the Earth’s climate. To explore the sensitivity of modeled BC spatial distributions to particle dry deposition treatments, the scheme of Petroff & Zhang (2010) (PZ10) is implemented into the Community Atmospheric Model version 5 (CAM5), and model simulations using PZ10 are compared with the one using the default scheme of Zhang et al. (2001) (Z01). The PZ10 scheme suggests much lower dry deposition velocities than Z01 for fine particles in Aitken, primary carbon, and accumulation modes, resulting in 73.0% lower of global mean BC dry deposition fluxes and 23.2% higher of global mean BC column burdens. CAM5 with PZ10 increases modeled BC concentrations at all altitudes and latitudes compared to Z01, which improves the agreement with observations of BC profiles in the lower troposphere in the Arctic. It also helps the simulation of surface BC concentrations in high-latitudes remote regions and its seasonality in the Arctic. Yet, PZ10 slightly exacerbates the overestimation of modeled BC concentrations in the middle and upper troposphere, which might be due to model uncertainties in other aerosol physical and chemical processes. The global annual mean radiative effects due to aerosol-radiation interactions (REari) and aerosol-cloud interactions (REaci) of BC from the CAM5 experiment using Z01 are 0.61±0.007 and -0.11±0.02 W m -2 , respectively, compared to slightly larger REari (0.75±0.01 W m -2 ) and REaci (-0.14±0.02 W m -2 ) from CAM5 using PZ10.

54 ENVIRONMENTAL SCIENCES↗

Spatial distribution of oxygen vacancies in Cr-doped SrTiO{sub 3} during an electric-field-driven insulator-to-metal transition

Spatially resolved x-ray fluorescence maps are presented that show the introduction and the evolution of oxygen vacancies in chromium-doped strontium titanate during an electric-field-driven insulator-to-metal transition. The vacancies are introduced at the anode and diffuse through the crystal toward the cathode. The spatial distribution of vacancies is explained by a model describing the electrical breakdown as a percolation process. Strong differences in the vacancy distribution were found when the transition took place in air and in a hydrogen-enriched atmosphere. In air, the vacancies disappeared from the surface, whereas in the reducing hydrogen atmosphere, they remained at the surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adaptive spatially resolving detector for the extreme ultraviolet with absolute measuring capability

A spatially resolving detector for the extreme ultraviolet (XUV) and soft x-ray spectral region is presented. Principle of operation is conversion of XUV radiation to visible light by a scintillator crystal. Luminescence is detected using charge coupled device camera and imaging optics. Single layer and multilayer coatings are applied to match the system to different spectral regions of interest. Field of view and spatial resolution can be adapted to the application. Calibration of the system enables to absolutely measure in-band radiation flux on the scintillator. The setup is designed for the characterization and optimization of XUV sources and XUV optical systems. Measurements, carried out to characterize the focus in a soft x-ray microscope, are presented as an application example.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Spatial Resolution for Reflection Mode Infrared Microscopy

Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the umerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using two different microscopes apable of diffraction-limited resolution: the first microscope is coupled to a synchrotron source and utilizes a single point detector, whereas the second microscope has a standard blackbody source and uses a focal planetarray (FPA) detector.

47 OTHER INSTRUMENTATION↗

Improved Spatial Resolution For Reflection Mode Infrared Spectromicroscopy

Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the numerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using a microscope coupled to a synchrotron source.

43 PARTICLE ACCELERATORS↗

Portable TXRF Spectrometer with 10{sup -11}g Detection Limit and Portable XRF Spectromicroscope with Sub-mm Spatial Resolution

A portable total reflection X-ray fluorescence (TXRF) spectrometer that we have developed is applied to trace elemental analysis of water solutions. Although a 5 W X-ray tube is used in the portable TXRF spectrometer, detection limits of several ppb are achieved for 3d transition metal elements and trace elements in a leaching solution of soils, a leaching solution of solder, and alcoholic beverages are detected. Portable X-ray fluorescence (XRF) spectromicroscopes with a 1 W X-ray tube and an 8 W X-ray tube are also presented. Using the portable XRF spectromicroscope with the 1 W X-ray tube, 93 ppm of Cr is detected with an about 700 {mu}m spatial resolution. Spatially resolved elemental analysis of a mug painted with blue, red, green, and white is performed using the two portable spectromicroscopes, and the difference in elemental composition at each paint is detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Spatial Resolution STXM at 6.2 keV Photon Energy

We report on a zone-doubling technique that bypasses the electron-beam lithography limitations for the production of X-ray diffractive optics and enables the fabrication of Fresnel zone plates with smaller outermost zone widths than other well-established approaches. We have applied this method to manufacture hard X-ray Fresnel zone plates with outermost zone widths of 25 and 20 nm. These lenses have been tested in scanning transmission X-ray microscopy (STXM) at energies up to 6.2 keV, producing images of test structures that demonstrate a spatial resolution of 25 nm. High spatial resolution STXM images of several biological specimens have been acquired in transmission, dark-field and differential phase contrast modes.

36 MATERIALS SCIENCE↗

Two color multichannel heterodyne interferometer set up for high spatial resolution electron density profile measurements in TJ-II

A high spatial resolution two color [CO{sub 2}, {lambda}=10.6 {mu}m/Nd:YAG (Nd:YAG denotes neodymium-doped yttrium aluminum garnet), and {lambda}=1.064 {mu}m] expanded-beam multichannel heterodyne interferometer has been installed on the TJ-II stellarator. Careful design of the optical system has allowed complete control on the evolution of both Gaussian beams along the interferometer, as well as the evaluation and optimization of the spatial resolution to be expected in the measurements. Five CO{sub 2} (measurement) channels and three Nd:YAG (vibration compensation) channels have been used to illuminate the plasma with a probe beam of 100 mm size. An optimum interpolation method has been applied to recover both interferometric phasefronts prior to mechanical vibration subtraction. The first results of the installed diagnostic are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of optical emission spectroscopy for He I considering the spatial structure of radiation trapping in MAP-II divertor simulator

The He I optical emission spectroscopy that considers the spatial structure of radiation trapping was proposed by us and was applied to a MAP-II divertor simulator. The spatial distribution of the optical escape factor was calculated from the n {sup 1}P (n{>=}3) state profiles measured by visible spectroscopy. The profile of 2 {sup 1}P, which is immeasurable by visible spectroscopy, needs to be broader than that of the 3 {sup 1}P state. The sensitivity of the 2 {sup 1}P profile to the T{sub e} value estimated by He I spectroscopy is investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Interpolation for evaluation of a two-dimensional spatial profile of plasma densities at low gas pressures

An interpolation algorithm for the evaluation of the spatial profile of plasma densities in a cylindrical reactor was developed for low gas pressures. The algorithm is based on a collisionless two-dimensional fluid model. Contrary to the collisional case, i.e., diffusion fluid model, the fitting algorithm depends on the aspect ratio of the cylindrical reactor. The spatial density profile of the collisionless fitting algorithm is presented in two-dimensional images and compared with the results of the diffusion fluid model.

42 ENGINEERING↗

How well do time-integrated K{sub {alpha}} images represent hot electron spatial distributions?

A computational study is described, which addresses how well spatially resolved time-integrated K{sub {alpha}} images recorded in intense laser-plasma experiments correlate with the distribution of ''hot'' (>1 MeV) electrons as they propagate through the target. The hot electron angular distribution leaving the laser-plasma region is critically important for many applications such as Fast Ignition or laser based x-ray sources; and K{sub {alpha}} images are commonly used as a diagnostic. It is found that K{sub {alpha}} images can easily mislead due to refluxing and other effects. Using the particle-in-cell code LSP, it is shown that a K{sub {alpha}} image is not solely determined by the initial population of forward directed hot electrons, but rather also depends upon ''delayed'' hot electrons, and in fact continues to evolve long after the end of the laser interaction. Of particular note, there is a population of hot electrons created during the laser-plasma interaction that acquire a velocity direction opposite that of the laser and subsequently reflux off the front surface of the target, deflect when they encounter magnetic fields in the laser-plasma region, and then traverse the target in a wide spatial distribution. These delayed fast electrons create significant features in the K{sub {alpha}} time-integrated images. Electrons refluxing from the sides and the back of the target are also found to play a significant role in forming the final K{alpha} image. The relative contribution of these processes is found to vary depending on depth within target. These effects make efforts to find simple correlations between K{alpha} images and, for example, Fast Ignition relevant parameters prone to error. Suggestions for future target design are provided.

07 ISOTOPE AND RADIATION SOURCES↗

Scanning photoelectron microscope for nanoscale three-dimensional spatial-resolved electron spectroscopy for chemical analysis

In order to achieve nondestructive observation of the three-dimensional spatially resolved electronic structure of solids, we have developed a scanning photoelectron microscope system with the capability of depth profiling in electron spectroscopy for chemical analysis (ESCA). We call this system 3D nano-ESCA. For focusing the x-ray, a Fresnel zone plate with a diameter of 200 {mu}m and an outermost zone width of 35 nm is used. In order to obtain the angular dependence of the photoelectron spectra for the depth-profile analysis without rotating the sample, we adopted a modified VG Scienta R3000 analyzer with an acceptance angle of 60 deg. as a high-resolution angle-resolved electron spectrometer. The system has been installed at the University-of-Tokyo Materials Science Outstation beamline, BL07LSU, at SPring-8. From the results of the line-scan profiles of the poly-Si/high-k gate patterns, we achieved a total spatial resolution better than 70 nm. The capability of our system for pinpoint depth-profile analysis and high-resolution chemical state analysis is demonstrated.

36 MATERIALS SCIENCE↗

Influence of the wavelength on the spatial resolution of pulsed-laser atom probe

Modern atom probes typically incorporate an ultrafast pulsed-laser source with wavelength ranging from infrared (IR) to ultraviolet (UV) depending on the specific instrument. In order to estimate the influence of the wavelength on the accuracy of the technique, the achievable in-depth spatial resolution has been measured for atom probe analyses of the same pure W specimen using three different wavelengths and across a range of laser pulse energies. UV illumination is shown to yield superior spatial resolution to both IR and visible (green) wavelengths. We propose that this improvement relates to a faster decay of temperature enabled by light absorption confined to the near apex region.

47 OTHER INSTRUMENTATION↗