Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Deformation of elastomeric pyramid pen arrays in cantilever-free scanning probe lithography

Cantilever-free scanning probe lithography (SPL) employs soft elastomeric pen arrays to deliver material or energy to a surface to achieve a high-resolution, high-throughput, and low-cost nanopatterning. In particular, microscale elastomeric pyramid pen arrays are often adopted as the cantilever-free architecture owing to their distinct structural and mechanical properties. To better understand the mechanical behavior of the elastomeric pyramid pen array during the lithographic printing process, we numerically investigate the compression of an elastomeric pyramid array in a nonadhesive and frictionless contact with a rigid substrate. Simple scaling laws of the width of the contact surface with respect to the compression displacement and force are found and compared with previous models and experiments. By changing the interpyramid distance or the thickness of the base of the pyramid array, increasing deviations from the established scaling laws are observed and explained. Finally, we demonstrate that the unique morphology of a compressed pyramid primarily determines the unusual shape of the features fabricated by a specific cantilever-free SPL technique.

36 MATERIALS SCIENCE↗

A 3D Computational Head Model Under Dynamic Head Rotation and Head Extension Validated Using Live Human Brain Data, Including the Falx and the Tentorium

We employ an advanced 3D computational model of the head with high anatomical fidelity, together with measured tissue properties, to assess the consequences of dynamic loading to the head in two distinct modes: head rotation and head extension. We use a subject-specific computational head model, using the material point method, built from T1 magnetic resonance images, and considering the anisotropic properties of the white matter which can predict strains in the brain under large rotational accelerations. The material model now includes the shear anisotropy of the white matter. We validate the model under head rotation and head extension motions using live human data, and advance a prior version of the model to include biofidelic falx and tentorium. Furthermore we then examine the consequences of incorporating the falx and tentorium in terms of the predictions from the computational head model.

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficacy of Sunitinib and Radiotherapy in Genetically Engineered Mouse Model of Soft-Tissue Sarcoma

Purpose: Sunitinib (SU) is a multitargeted receptor tyrosine kinase inhibitor of the vascular endothelial growth factor and platelet-derived growth factor receptors. The present study examined SU and radiotherapy (RT) in a genetically engineered mouse model of soft tissue sarcoma (STS). Methods and Materials: Primary extremity STSs were generated in genetically engineered mice. The mice were randomized to treatment with SU, RT (10 Gy x 2), or both (SU+RT). Changes in the tumor vasculature before and after treatment were assessed in vivo using fluorescence-mediated tomography. The control and treated tumors were harvested and extensively analyzed. Results: The mean fluorescence in the tumors was not decreased by RT but decreased 38-44% in tumors treated with SU or SU+RT. The control tumors grew to a mean of 1378 mm{sup 3} after 12 days. SU alone or RT alone delayed tumor growth by 56% and 41%, respectively, but maximal growth inhibition (71%) was observed with the combination therapy. SU target effects were confirmed by loss of target receptor phosphorylation and alterations in SU-related gene expression. Cancer cell proliferation was decreased and apoptosis increased in the SU and RT groups, with a synergistic effect on apoptosis observed in the SU+RT group. RT had a minimal effect on the tumor microvessel density and endothelial cell-specific apoptosis, but SU alone or SU+RT decreased the microvessel density by >66% and induced significant endothelial cell apoptosis. Conclusion: SU inhibited STS growth by effects on both cancer cells and tumor vasculature. SU also augmented the efficacy of RT, suggesting that this combination strategy could improve local control of STS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results From a Prospective Study Using Limited Margin Radiotherapy in Pediatric and Young Adult Patients With High-Grade Nonrhabdomyosarcoma Soft-Tissue Sarcoma

Purpose: To demonstrate the safety and efficacy of limited margin radiotherapy in the local control of pediatric and young adult patients with high-grade nonrhabdomyosarcoma soft tissue sarcoma (NRSTS). Methods and Materials: Pediatric patients with high-grade NRSTS requiring radiation were treated on an institutional review board approved prospective institutional study of conformal/intensity-modulated/interstitial brachytherapy using a 2-cm anatomically constrained margin. Results: A total of 32 patients (median age, 15.3 years; range, 2-22 years) received adjuvant (27 patients) or definitive (5 patients) irradiation. With a median follow-up of 32 months, the 3-year cumulative incidence of local failure was 3.7% for patients undergoing irradiation after surgical resection. Four patients experienced local failure; the mean dose to the volume of recurrence was >=97% of the prescribed dose. Conclusions: Delivery of limited margin radiotherapy using external beam or brachytherapy provides a high rate of local tumor control without marginal failure. Further follow-up is required to determine whether normal tissue effects are minimized using this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Versus Postoperative Radiotherapy in Soft-Tissue Sarcoma: Multi-Institutional Analysis of 821 Patients

Purpose: To assess the impact of radiotherapy (RT) sequencing with surgery on overall survival (OS), cause-specific survival (CSS), local failure, and distant failure in soft-tissue sarcoma (STS). Methods and Materials: A retrospective analysis was conducted using the National Oncology Database, a proprietary database of aggregated tumor registries owned by IMPAC Medical Systems (Sunnyvale, CA). Patients with STS of all major anatomic sites who received definitive surgery and either preoperative (preop) or postoperative (postop) RT were included. Patients were also required to have known stage and grade. Prognostic factors for survival were identified using multivariate techniques. Survival was calculated using the Kaplan-Meier method, and compared for statistical significance (p < 0.05) using the log-rank test. Results: A total of 821 patients met inclusion criteria. The median follow-up time was 63 months. Age, stage, histology, gender, tumor size, and RT sequence were independent predictors for OS (p < 0.05). Preop RT was associated with significantly improved OS and CSS compared with postop RT (hazard ratio [HR] = 0.72, 95% confidence interval [CI] 0.56-0.91, p < 0.01, and HR = 0.64, 95% CI 0.46-0.88, p < 0.01, respectively). The 5-year CSS was 79% and 74%, in favor of preop RT (log-rank, p < 0.05). Preop RT was also significantly associated with a reduced risk for local and distant relapse compared with postop RT. Conclusion: Preoperative RT is associated with a reduced cancer-specific mortality compared with postoperative RT in STS. The results of this study may serve as motivation to conduct future prospective studies with larger patient numbers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic Tumor Location Influences the Success of Contemporary Limb-Sparing Surgery and Radiation Among Adults With Soft Tissue Sarcomas of the Extremities

Purpose: To examine the influence of anatomic location in the upper extremity (UE) vs. lower extremity (LE) on the presentation and outcomes of adult soft tissue sarcomas (STS). Methods and Materials: From 2001 to 2008, 118 patients underwent limb-sparing surgery (LSS) and external beam radiotherapy (RT) with curative intent for nonrecurrent extremity STS. RT was delivered preoperatively in 96 and postoperatively in 22 patients. Lesions arose in the UE in 28 and in the LE in 90 patients. Patients with UE lesions had smaller tumors (4.5 vs. 9.0 cm, p < 0.01), were more likely to undergo a prior excision (43 vs. 22%, p = 0.03), to have close or positive margins after resection (71 vs. 49%, p = 0.04), and to undergo postoperative RT (32 vs. 14%, p = 0.04). Results: Five-year actuarial local recurrence-free and distant metastasis-free survival rates for the entire group were 85 and 74%, with no difference observed between the UE and LE cohorts. Five-year actuarial probability of wound reoperation rates were 4 vs. 29% (p < 0.01) in the UE and LE respectively. Thigh lesions accounted for 84% of the required wound reoperations. The distribution of tumors within the anterior, medial, and posterior thigh compartments was 51%, 26%, and 23%. Subset analysis by compartment showed no difference in the probability of wound reoperation between the anterior and medial/posterior compartments (29 vs. 30%, p = 0.68). Neurolysis was performed during resection in (15%, 5%, and 67%, p < 0.01) of tumors in the anterior, medial, and posterior compartments. Conclusions: Tumors in the UE and LE differ significantly with respect to size and management details. The anatomy of the UE poses technical impediments to an R0 resection. Thigh tumors are associated with higher wound reoperation rates. Tumor resection in the posterior thigh compartment is more likely to result in nerve injury. A better understanding of the inherent differences between tumors in various extremity sites will assist in individualizing treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combination of External Beam Radiotherapy (EBRT) With Intratumoral Injection of Dendritic Cells as Neo-Adjuvant Treatment of High-Risk Soft Tissue Sarcoma Patients

Purpose: The goal of this study was to determine the effect of combination of intratumoral administration of dendritic cells (DC) and fractionated external beam radiation (EBRT) on tumor-specific immune responses in patients with soft-tissue sarcoma (STS). Methods and Material: Seventeen patients with large (>5 cm) high-grade STS were enrolled in the study. They were treated in the neoadjuvant setting with 5,040 cGy of EBRT, split into 28 fractions and delivered 5 days per week, combined with intratumoral injection of 10{sup 7} DCs followed by complete resection. DCs were injected on the second, third, and fourth Friday of the treatment cycle. Clinical evaluation and immunological assessments were performed. Results: The treatment was well tolerated. No patient had tumor-specific immune responses before combined EBRT/DC therapy; 9 patients (52.9%) developed tumor-specific immune responses, which lasted from 11 to 42 weeks. Twelve of 17 patients (70.6%) were progression free after 1 year. Treatment caused a dramatic accumulation of T cells in the tumor. The presence of CD4{sup +} T cells in the tumor positively correlated with tumor-specific immune responses that developed following combined therapy. Accumulation of myeloid-derived suppressor cells but not regulatory T cells negatively correlated with the development of tumor-specific immune responses. Experiments with {sup 111}In labeled DCs demonstrated that these antigen presenting cells need at least 48 h to start migrating from tumor site. Conclusions: Combination of intratumoral DC administration with EBRT was safe and resulted in induction of antitumor immune responses. This suggests that this therapy is promising and needs further testing in clinical trials design to assess clinical efficacy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RTOG Sarcoma Radiation Oncologists Reach Consensus on Gross Tumor Volume and Clinical Target Volume on Computed Tomographic Images for Preoperative Radiotherapy of Primary Soft Tissue Sarcoma of Extremity in Radiation Therapy Oncology Group Studies

Objective: To develop a Radiation Therapy Oncology Group (RTOG) atlas delineating gross tumor volume (GTV) and clinical target volume (CTV) to be used for preoperative radiotherapy of primary extremity soft tissue sarcoma (STS). Methods and Materials: A consensus meeting was held during the RTOG meeting in January 2010 to reach agreement about GTV and CTV delineation on computed tomography (CT) images for preoperative radiotherapy of high-grade large extremity STS. Data were presented to address the local extension of STS. Extensive discussion ensued to develop optimal criteria for GTV and CTV delineation on CT images. Results: A consensus was reached on appropriate CT-based GTV and CTV. The GTV is gross tumor defined by T1 contrast-enhanced magnetic resonance images. Fusion of magnetic resonance and images is recommended to delineate the GTV. The CTV for high-grade large STS typically includes the GTV plus 3-cm margins in the longitudinal directions. If this causes the field to extend beyond the compartment, the field can be shortened to include the end of a compartment. The radial margin from the lesion should be 1.5 cm, including any portion of the tumor not confined by an intact fascial barrier, bone, or skin surface. Conclusion: The consensus on GTV and CTV for preoperative radiotherapy of high-grade large extremity STS is available as web-based images and in a descriptive format through the RTOG. This is expected to improve target volume consistency and allow for rigorous evaluation of the benefits and risks of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Effect Relationships for Femoral Fractures After Multimodality Limb-Sparing Therapy of Soft-Tissue Sarcomas of the Proximal Lower Extremity

Purpose: We investigated the clinical and dosimetric predictors for radiation-associated femoral fractures in patients with proximal lower extremity soft tissue sarcomas (STS). Methods and Materials: We examined 131 patients with proximal lower extremity STS who received limb-sparing surgery and external-beam radiation therapy between 1985 and 2006. Five (4%) patients sustained pathologic femoral fractures. Dosimetric analysis was limited to 4 fracture patients with full three-dimensional dose information, who were compared with 59 nonfracture patients. The mean doses and volumes of bone (V{sub d}) receiving specified doses ({>=}30 Gy, 45 Gy, 60 Gy) at the femoral body, femoral neck, intertrochanteric region, and subtrochanteric region were compared. Clinical predictive factors were also evaluated. Results: Of 4 fracture patients in our dosimetric series, there were three femoral neck fractures with a mean dose of 57.6 {+-} 8.9 Gy, V30 of 14.5 {+-} 2.3 cc, V45 of 11.8 {+-} 1.1 cc, and V60 of 7.2 {+-} 2.2 cc at the femoral neck compared with 22.9 {+-} 20.8 Gy, 4.8 {+-} 5.6 cc, 2.5 {+-} 3.9 cc, and 0.8 {+-} 2.7 cc, respectively, for nonfracture patients (p < 0.03 for all). The femoral neck fracture rate was higher than at the subtrochanteric region despite lower mean doses at these subregions. All fracture sites received mean doses greater than 40 Gy. Also, with our policy of prophylactic femoral intramedullary nailing for high-risk patients, there was no significant difference in fracture rates between patients with and without periosteal excision. There were no significant differences in age, sex, tumor size, timing of radiation therapy, and use of chemotherapy between fracture and nonfracture patients. Conclusions: These dose-volume toxicity relationships provide RT optimization goals to guide future efforts for reducing pathologic fracture rates. Prophylactic femoral intramedullary nailing may also reduce fracture risk for susceptible patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histologic Appearance After Preoperative Radiation Therapy for Soft Tissue Sarcoma: Assessment of the European Organization for Research and Treatment of Cancer–Soft Tissue and Bone Sarcoma Group Response Score

Purpose: To critically assess the prognostic value of the European Organization for Research and Treatment of Cancer–Soft Tissue and Bone Sarcoma Group (EORTC-STBSG) response score and define histologic appearance after preoperative radiation therapy (RT) for soft tissue sarcoma (STS). Methods and Materials: For a cohort of 100 patients with STS of the extremity/trunk treated at our institution with preoperative RT followed by resection, 2 expert sarcoma pathologists evaluated the resected specimens for percent residual viable cells, necrosis, hyalinization/fibrosis, and infarction. The EORTC response score and other predictors of recurrence-free survival (RFS) and overall survival (OS) were assessed by Kaplan-Meier and proportional hazard models. Results: Median tumor size was 7.5 cm; 92% were intermediate or high grade. Most common histologies were unclassified sarcoma (34%) and myxofibrosarcoma (25%). Median follow-up was 60 months. The 5-year local recurrence rate was 5%, 5-year RFS was 68%, and 5-year OS was 75%. Distribution of cases according to EORTC response score tiers was as follows: no residual viable tumor for 9 cases (9% pathologic complete response); <1% viable tumor for 0, ≥1% to <10% for 9, ≥10% to <50% for 44, and ≥50% for 38. There was no association between EORTC-STBSG response score and RFS or OS. Conversely, hyalinization/fibrosis was a significant independent favorable predictor for RFS (hazard ratio 0.49, P=.007) and OS (hazard ratio 0.36, P=.02). Conclusion: Histologic evaluation after preoperative RT for STS showed a 9% pathologic complete response rate. The EORTC-STBSG response score and percent viable cells were not prognostic. Hyalinization/fibrosis was associated with favorable outcome, and if validated, may become a valid endpoint for neoadjuvant trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine learning based inverse modeling of full-field strain distribution for mechanical characterization of a linear elastic and heterogeneous membrane

Heterogeneous membranes or films are thin and soft structures with spatial variations in material property and thickness. Mechanical behavior of heterogeneous membranes is not well understood, mainly due to the difficulty in obtaining accurate and reliable material property data. To understand the mechanical behavior of these materials, accurate and efficient characterization methods for heterogeneous membranes are needed. Here, in this paper, an inverse method based on machine learning is developed to efficiently extract mechanical properties from full-field strain distributions. This approach is demonstrated on a flat heterogeneous membrane with uniform thickness formed by up to four linear elastic synthetic materials in a grid arrangement, and deforming in a moderate strain range (true strain ~10%). The results show that the machine learning method achieves accuracy comparable to the traditional inverse finite element method, and is 6 orders of magnitude faster in the demonstrated case studies.

36 MATERIALS SCIENCE↗

Electrochemical/Mechanical Coupling in Ion-Conducting Soft Matter

Mechanical and electrochemical phenomena exhibit many interesting multidirectional couplings in ion-exchange soft matter due to their intrinsic material physiochemical states and responses to environmental stressors. Such coupling is explored in terms of recent studies with a focus on the degradation of polymer-electrolyte fuel-cell membranes. In addition, (electro)chemical–mechanical coupling of ion-conducting polymers in other applications is also introduced, as there is a research need to explore the interactions between these often wrongly assumed disparate fields in order to optimize, exploit, and discover new technologies and applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sulfur Diffusion within Nitrogen-Doped Ordered Mesoporous Carbons Determined by in Situ X-ray Scattering

The low intrinsic conductivity of sulfur necessitates conductive additives, such as mesoporous carbons, to the cathode to enable high-performance metal–sulfur batteries. Simultaneous efforts to address polysulfide shuttling have introduced nitrogen-doped carbons to provide both conductivity and suppressed shuttling because of their strong interaction with sulfur. The strength of this interaction will impact the ability to fill the mesopores with sulfur via melt infusion. Here in this study, we systematically investigate how nitrogen doping influences the rate that molten sulfur can infiltrate the mesopores and the overall extent of pore filling of highly ordered mesoporous doped carbons using in situ small angle X-ray scattering (SAXS). The similarity in electron density between molten sulfur and the soft carbon framework of the mesoporous material leads to a precipitous decrease in the scattered intensity associated with the ordered structure as voids are filled with sulfur. As the nitrogen doping increases from 1 to 20 at. %, the effective diffusivity of sulfur in the mesopores decreases by an order of magnitude (2.7 × 10 –8 to 2.3 × 10 –9 cm/s). The scattering becomes nearly invariant within 20 min of melt infiltration at 155 °C for all but the most doped carbon, which indicates that submicron-sized mesoporous carbon particles can be filled rapidly. Additionally, the nitrogen doping decreases the sulfur content that can be accommodated within the mesopores from 95% of the mesopores filled without doping to only 64% filled with 20 at. % N as determined by the residual scattering intensity. Sulfur does not crystallize within the mesopores of the nitrogen-doped carbons, which is further indicative of the strong interactions between the nitrogen species and sulfur that can inhibit polysulfide shuttling. Lastly, in situ SAXS provides insights into the diffusion of sulfur in mesopores and how the surface chemistry of nitrogen-doped carbon appears to significantly hinder the infiltration by sulfur.

36 MATERIALS SCIENCE↗

Fabrication of nanoscale patterns in lithium fluoride crystal using a 13.5 nm Schwarzschild objective and a laser produced plasma source

Lithium fluoride (LiF) crystal is a radiation sensitive material widely used as EUV and soft x-ray detector. The LiF-based detector has high resolution, in principle limited by the point defect size, large field of view, and wide dynamic range. Using LiF crystal as an imaging detector, a resolution of 900 nm was achieved by a projection imaging of test meshes with a Schwarzschild objective operating at 13.5 nm. In addition, by imaging of a pinhole illuminated by the plasma, an EUV spot of 1.5 {mu}m diameter in the image plane of the objective was generated, which accomplished direct writing of color centers with resolution of 800 nm. In order to avoid sample damage and contamination due to the influence of huge debris flux produced by the plasma source, a spherical normal-incidence condenser was used to collect EUV radiation. Together with a description of experimental results, the development of the Schwarzschild objective, the influence of condenser on energy density and the alignment of the imaging system are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct measurement of storage and loss behavior in AFM force–distance experiments using the modified Fourier transformation

Force–distance curve experiments are commonly performed in atomic force microscopy (AFM) to obtain the viscoelastic characteristics of materials, such as the storage and loss moduli or compliances. The classic methods used to obtain these characteristics consist of fitting a viscoelastic material model to the experimentally obtained AFM data. Here, we demonstrate a new method that utilizes the modified discrete Fourier transform to approximate the storage and loss behavior of a material directly from the data, without the need for a fit. Additionally, one may still fit a model to the resulting storage and loss behavior if a parameterized description of the material is desired. In contrast to fitting the data to a model chosen a priori, departing from a model-free description of the material's frequency behavior guides the selection of the model, such that the user may choose the one that is most appropriate for the particular material under study. To this end, we also include modified Fourier domain descriptions of commonly used viscoelastic models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CENTAUR - The small- and wide-angle neutron scattering diffractometer/spectrometer for the Second Target Station of the Spallation Neutron Source

CENTAUR has been selected as one of the eight initial instruments to be built at the Second Target Station (STS) of the Spallation Neutron Source at Oak Ridge National Laboratory. It is a small-angle neutron scattering (SANS) and wide-angle neutron scattering (WANS) instrument with diffraction and spectroscopic capabilities. This instrument will maximally leverage the high brightness of the STS source, the state-of-the-art neutron optics, and a suite of detectors to deliver unprecedented capabilities that enable measurements over a wide range of length scales with excellent resolution, measurements on smaller samples, and time-resolved investigations of evolving structures. Notably, the simultaneous WANS and diffraction capability will be unique among neutron scattering instruments in the United States. This instrument will provide much needed capabilities for soft matter and polymer sciences, geology, biology, quantum condensed matter, and other materials sciences that need in situ and operando experiments for kinetic and/or out-of-equilibrium studies. Beam polarization and a high-resolution chopper will enable detailed structural and dynamical investigations of magnetic and quantum materials. CENTAUR’s excellent resolution makes it ideal for low-angle diffraction studies of highly ordered large-scale structures, such as skyrmions, shear-induced ordering in colloids, and biomembranes. Additionally, the spectroscopic mode of this instrument extends to lower momentum transfers than are currently possible with existing spectrometers, thereby providing a unique capability for inelastic SANS studies.

47 OTHER INSTRUMENTATION↗

Nonuniform Flow Dynamics Probed by Nanosecond X-Ray Speckle Visibility Spectroscopy

We report observations of nanosecond nonuniform colloidal dynamics in a free flowing liquid jet using ultrafast x-ray speckle visibility spectroscopy. Utilizing a nanosecond double-bunch mode, the Linac Coherent Light Source free electron laser produced pairs of femtosecond coherent hard x-ray pulses. By exploring anisotropy in the visibility of summed speckle patterns which relates to the correlation functions, we evaluate not only the average particle flow rate in a colloidal nanoparticle jet, but also the nonuniform flow field within. The methodology presented here establishes the foundation for the study of nano- and atomic-scale inhomogeneous fluctuations in complex matter using x-ray free electron laser sources.

47 OTHER INSTRUMENTATION↗