Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Argonne Pixel Tracking Telescope at the Fermilab Test Beam Facility

The Argonne Pixel Tracking Telescope is installed at the Fermilab Test Beam Facility. The telescope consists of six planar n + -in-n silicon sensors with a pixel size of 250 × 50 μm 2 . The instrumentation of the telescope is described including the electrical and mechanical setups. A 120 GeV proton beam is used to evaluate the telescope performance using criteria such as cluster size, pixel tracking efficiency, and spatial resolution. The spatial resolution of the telescope is measured to be 72 μm × 13 μm and is consistent with the resolution determined from the simulation. In conclusion, this telescope will be used to test the performance of the various silicon pixel technology as well as to study the effects and the performance of the detectors after being irradiated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualisation of sulphur on single fibre level for pulping industry

In the pulp and paper industry, about 5 Mt/y chemithermomechanical pulp (CTMP) are produced globally from softwood chips for production of carton board grades. For tailor making CTMP for this purpose, wood chips are impregnated with aqueous sodium sulphite for sulphonation of the wood lignin. When lignin is sulphonated, the defibration of wood into pulp becomes more selective, resulting in enhanced pulp properties. On a microscopic fibre scale, however, one could strongly assume that the sulphonation of the wood structure is very uneven due to its macroscale size of wood chips. If this is the case and the sulphonation could be done significantly more evenly, the CTMP process could be more efficient and produce pulp even better suited for carton boards. Therefore, the present study aimed to develop a technique based on X-ray fluorescence microscopy imaging (µXRF) for quantifying the sulphur distribution on CTMP wood fibres. Firstly, the feasibility of µXRF imaging for sulphur homogeneity measurements in wood fibres needs investigation. Therefore, clarification of which spatial and spectral resolution that allows visualization of sulphur impregnation into single wood fibres is needed. Measurements of single fibre imaging were carried out at the Argonne National Laboratory's Advanced Photon Source (APS) synchrotron facility. With a synchrotron beam using one micrometre scanning step, images of elemental mapping are acquired from CTMP samples diluted with non-sulphonated pulp under specified conditions. Since the measurements show significant differences between sulphonated and non-sulphonated fibres, and a significant peak concentration in the shell of the sulphonated fibres, the proposed technique is found to be feasible. The required spatial resolution of the µXRF imaging for an on-site CTMP sulphur homogeneity measurement setup is about 15 µm, and the homogeneity measured along the fibre shells is suggested to be used as the CTMP sulphonation measurement parameter.

CTMP↗

Development of a novel, windowless, amorphous selenium based photodetector for use in liquid noble detectors

Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. Here in this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufacturing and experimental setup used to operate this detector at low transport electric fields (2.7–5.2 V/μm) and across a wide range of temperatures (77 K–290 K). This work shows that the first proof-of-principle windowless amorphous selenium device is robust under cryogenic conditions, responsive to VUV light at cryogenic temperatures, and preserves argon purity. These findings motivate a continued exploration of amorphous selenium devices for simultaneous detection of scintillation light and ionization charge in noble element detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TriWaSp: a multi-faceted visible spectroscopy diagnostic on the ST40 tokamak

Here, we present a new state-of-the-art Triple Wavelength Spectrometer (TriWaSp), recently deployed on ST40, a high field low aspect ratio spherical tokamak. The TriWaSp has a range of possible applications due to its flexible design; the current configuration focuses on charge exchange recombination spectroscopy from carbon and neon impurities in the ST40 plasma. This paper discusses the detailed setup of the system and presents initial charge exchange ion temperature measurements using a single line of sight, which show good agreement with other ion temperature diagnostics. Building on these commissioning results and forward modelling of the system, a new observation geometry has been implemented for the next experimental campaign which will considerably improve the localisation of ion temperature and velocity profile measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors

Abstract Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the contribution of muons from cosmic sources can constitute a significant fraction of these interactions. As most of these muons are difficult to stop, we perform a conceptual study of a two-layer silicon pixel detector to tag their hits on a solid-state quantum processor instead. With a typical dilution refrigerator geometry model, we find that efficiencies greater than 50% are most likely to be achieved if at least one of the layers is operated at the deep-cryogenic (<1 K) flanges of the refrigerator. Following this finding, we further propose a novel research program that could allow the development of silicon pixel detectors that are fast enough to provide input to quantum error correction algorithms, can operate at deep-cryogenic temperatures, and have very low power consumption.

Instruments & Instrumentation↗

Plasma-based particle sources

High-brightness particle beams generated by advanced accelerator concepts have the potential to become an essential part of future accelerator technology. In particular, high-gradient accelerators can generate and rapidly accelerate particle beams to relativistic energies. The rapid acceleration and strong confining fields can minimize irreversible detrimental effects to the beam brightness that occur at low beam energies, such as emittance growth or pulse elongation caused by space charge forces. Due to the high accelerating gradients, these novel accelerators are also significantly more compact than conventional technology. Advanced accelerators can be extremely variable and are capable of generating particle beams with vastly different properties using the same driver and setup with only modest changes to the interaction parameters. So far, efforts have mainly been focused on the generation of electron beams, but there are concepts to extend the sources to generate spin-polarized electron beams or positron beams. The beam parameters of these particle sources are largely determined by the injection and subsequent acceleration processes. Although, over the last decade there has been significant progress, the sources are still lacking a sufficiently high 6-dimensional (D) phase-space density that includes small transverse emittance, small energy spread and high charge, and operation at high repetition rate. This is required for future particle colliders with a sufficiently high luminosity or for more near-term applications, such as enabling the operation of free-electron lasers (FELs) in the X-ray regime. Major research and development efforts are required to address these limitations in order to realize these approaches for a front-end injector for a future collider or next-generation light sources. In particular, this includes methods to control and manipulate the phase-space and spin degrees-of-freedom of ultrashort plasma-based electron bunches with high accuracy, and methods that increase efficiency and repetition rate. These efforts also include the development of high-resolution diagnostics, such as full 6D phase-space measurements, beam polarimetry and high-fidelity simulation tools. A further increase in beam luminosity can be achieve through emittance damping. Emittance cooling via the emission of synchrotron radiation using current technology requires kilometer-scale damping rings. For future colliders, the damping rings might be replaced by a substantially more compact plasma-based approach. Here, plasma wigglers with significantly stronger magnetic fields are used instead of permanent-magnet based wigglers to achieve similar damping performance but over a two orders of magnitude reduced length.

43 PARTICLE ACCELERATORS↗

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors↗

Radon emanation rate measurements using liquid scintillation counting

This article describes a radon emanation measurement technique using liquid scintillator counting. A model for radon loading and transport is described, along with its calibration. Detector background and blank have been studied and quantified. The Minimal detectable activity has been determined for the counting setup using a toy Monte Carlo simulation. Here, the measurement technique is validated using a butyl rubber sample previously used for cross-calibration between different radon counting facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a test system for data links of the ATLAS Inner Tracker (ITk) upgrade silicon pixel detector

This contribution introduces a novel test system developed to evaluate the signal transmission quality in high-speed data links for the 2026 Inner Tracker (ITk) upgrade of the ATLAS experiment. Using an FPGA-based data acquisition (DAQ) framework, the setup can run simultaneous Bit Error Rate (BER) tests for up to 64 channels and generate virtual eye diagrams, for qualifying the ∼26k electrical links at the ATLAS ITk data rate of 1.28 Gb/s. The paper includes results from system calibration, yielding its contribution to the measured losses, and preliminary results from tests of prototype and pre-production assemblies of on-detector links of the three ATLAS ITk Pixel subsystems.

47 OTHER INSTRUMENTATION↗

Evaluation of the response to electrons and pions in the scintillating fiber and lead calorimeter for the future electron-ion collider

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) — a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) — was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detector at the Electron-Ion Collider (EIC). The detector response to electrons and pions was studied at beam energies between 4 and 10 GeV, extending previous GlueX tests to a higher energy regime. The calibrated detector exhibits good linearity within uncertainties, and its electron energy resolution meets EIC requirements. The data further constrain the constant term in the energy resolution to below 1.9%, improving upon previous constraints at lower energies. Simulations reproduce key features of the electron and pion data within the limitations of the collected dataset and the FTBF test environment. Electron-pion separation in the test beam setup was analyzed using multiple methods, incorporating varying degrees of beam-related effects. The inclusion of longitudinal shower profile information enhanced the separation performance, underscoring its relevance for the full-scale BIC in ePIC. These results provide essential benchmarks for the Pb/ScFi section of the future BIC, validating detector simulations and guiding optimization strategies for electron-pion discrimination.

47 OTHER INSTRUMENTATION↗

Time-tagging data acquisition system for testing superconducting electronics based on an RFSoC and custom analog frontend

Novel electronic devices can often be operated in a plethoraof ways, which makes testing circuits comprised of them difficult.Often, no single tool can simultaneously analyze the operatingmargins, maximum speed, and failure modes of a circuit, particularlywhen the intended behavior of subcomponents of the circuit is notstandardized. This work demonstrates a cost-effective time-domaindata acquisition system for electronic circuits that enables moreintricate verification techniques than are practical withconventional experimental setups. We use high-speeddigital-to-analog converters and real-timemulti-gigasample-per-second waveform processing to push experimentalcircuits beyond their maximum operating speed. Our customtime-tagging data capture firmware reduces memory requirements andcan be used to determine when errors occur. The firmware iscombined with a thermal-noise-limited analog frontend with50 dB of dynamic range. Compared to currentlyavailable commercial test equipment that is seven times moreexpensive, this data acquisition system was able to operate asuperconducting shift register at a nearly three-times-higher clockfrequency (200 MHz vs. 80 MHz).

Foster, Reed A. [MIT] (ORCID:0000000231002127)↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Studying AC-LGAD strip sensors from laser and testbeam measurements

Here, this paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate R&D efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.

FOS: Physical sciences↗

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

Behavior of solitary waves of coupled nonlinear Schrödinger equations subjected to complex external periodic potentials with odd-$\mathcal{PT}$ symmetry

In this work, we discuss the response of both moving and trapped solitary wave solutions of a two-component nonlinear Schrödinger system in 1 + 1 dimensions to an odd-$\mathcal{PT}$ external periodic complex potential. The dynamical behavior of perturbed solitary waves is explored by conducting numerical simulations of the nonlinear system and using a collective coordinate variational approximation. We present case examples corresponding to choices of parameter values and initial conditions involved therein. The results of the collective coordinate approximation are compared against numerical simulations where we observe qualitatively good agreement between the two. Unlike the case for a single-component solitary wave in a complex periodic $\mathcal{PT}$-symmetric potential, the collective coordinate equations do not have a small oscillation regime, and initially the height of the two components changes in opposite directions often causing instability. We find that the dynamic stability criteria we have used in the one-component case are a good indicator for the onset of dynamic instabilities in the present setup.

97 MATHEMATICS AND COMPUTING↗