Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Iodine detection in Ag-mordenite based sensors: Charge conduction pathway determinations

Detection of radiological iodine gas after nuclear accidents or in nuclear fuel reprocessing is necessary for the safety of human life and the environment. The development of sensors for the detection of iodine benefits from the incorporation of nanoporous materials with high selectivity for I 2 from common competing gases in air. Silver mordenite zeolite (Ag-MOR) is widely-used material for capture of gaseous iodine (I 2 ). In this paper, thin film zeolite coatings were applied to Pt interdigitated electrodes (IEDs) to fabricate iodine gas sensors with direct electrical readout responses. Correlations between occluded ion, exposure to iodine gas, resultant AgI nanoparticle polymorphs and location in zeolite with resultant impedance spectroscopy (IS) properties are described. Furthermore, IS is leveraged to elucidate the changes in charge conduction pathways as determined by the cation-zeolite film incorporated in the sensor. Silver mordenite reveals a significant change in impedance upon exposure to gaseous I 2 at 70 °C, and the magnitude and direction of the response is dependent on whether the Ag + -mordenite is reduced (Ag 0 ) before I 2 exposure. An equivalent circuit model is developed to describe the movement of charge along the surface and through the pores of the mordenite grains. Relative changes in the impedance of these conduction pathways are related to the chemical changes from Ag + or Ag 0 to resultant AgI polymorph phase. Lastly, together, these results inform design of a compact Ag-mordenite sensor for direct electrical detection of gaseous I 2 .

36 MATERIALS SCIENCE↗

A low-noise CMOS pixel direct charge sensor, Topmetal-II -

In this paper, we report the design and characterization of a CMOS pixel direct charge sensor, Topmetal-II-, fabricated in a standard 0.35 μm CMOS Integrated Circuit process. The sensor utilizes exposed metal patches on top of each pixel to directly collect charge. Each pixel contains a low-noise charge-sensitive preamplifier to establish the analog signal and a discriminator with tunable threshold to generate hits. The analog signal from each pixel is accessible through time-shared multiplexing over the entire array. Hits are read out digitally through a column-based priority logic structure. Tests show that the sensor achieved a <15e - analog noise and a 200e - minimum threshold for digital readout per pixel. The sensor is capable of detecting both electrons and ions drifting in gas. Lastly, these characteristics enable its use as the charge readout device in future Time Projection Chambers without gaseous gain mechanism, which has unique advantages in low background and low rate-density experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation tolerance study on irradiated AC-coupled, poly-silicon biased, p-on-n silicon strip sensors developed in India

The silicon sensors to be deployed in the next generation high energy physics experiments for operation in high luminosity scenarios, will require a high level of radiation tolerance. AC-coupled silicon strip sensors integrated with biasing poly-silicon resistors have been fabricated in collaboration with the Bharat Electronics Limited foundry using 4 inch n-type wafers in p-on-n configuration. Several sensors were irradiated with protons at different fluences at the Karlsruhe Cyclotron facility under the Advanced European Infrastructures for Detectors at Accelerators (AIDA) program. This paper reports on these radiation hardness study performed on the AC-coupled silicon sensors fabricated in India. The characterization comprises of electrical tests, including total current, voltage and strip scans and charge collection studies.

AC-coupled↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microbial potentiometric sensor: A new approach to longstanding challenges

The underlying hypothesis of this study is that simple potentiometric measurements between sensing electrodes and a shared reference electrode - Microbial Potentiometric Sesnor (MPS) system - can be employed in a long-term, continuous mode of operation to resolve the spatial and temporal changes in environmental systems. To address the hypothesis, (1) a conceptual description of the MPS system and its postulated principle of operation are provided; (2) the MPS system performance is documented under controlled laboratory conditions; and (3) the capabilities of the MPS system are documented under quiescent and dynamic field condition. In a laboratory setting, the variability among different MPS signals was insignificant confirming the postulated high accuracy and reproducibility of the sensor performance. It also demonstrated statistically significant correlations with dissolved oxygen (DO) and oxidation-reduction potential (ORP) sensors, while showing capabilities of operating under anoxic and anaerobic conditions. Regardless of their locations in the model wetland system, three MPS sensors functioned without interruption and cleaning for a period >2 years, and thus demonstrating long-term durability of the MPS technology. In real batch-wastewater treatment facility, the deployed MPS system signals were able to describe the organic carbon trends and correlate with each treatment phase in a cycle. Data reproducibility and reliability exceeded the expectations better describing the carbon treatment levels than the DO and ORP sensors (p < 4.4 × 10 –162 vs phase adjusted p < 3.0 × 10 –58 ). While MPS signals correlate with specific parameters that describe the local process or environments, it is more prudent to employ both the magnitude and pattern of a composite signal like the MPS signal describe the change to reflect any shift in the local environment. Finally, when compared to a baseline pattern, this change in signal magnitude and pattern reveals important information that can be employed to tailor and optimize any condition or process which involves microorganisms.

47 OTHER INSTRUMENTATION↗

Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laser

A mid-infrared ethane (C 2 H 6 ) sensor based on a wavelength modulation spectroscopy (WMS) technique was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) interband cascade laser (ICL) emitting at 3.34 μm and a dense multi-pass gas cell (MPGC, 17 × 6.5 × 5.5 cm 3 ) with a 54.6 m optical path length. A compact optical sensor system with a physical size of 35.5 × 18 × 12.5 cm 3 was designed and constructed. An ICL was employed for targeting a strong C 2 H 6 line at 2996.88 cm -1 at <100 Torr gas pressure in the fundamental absorption band of C 2 H 6 . The sensor performance, including the minimum detection limit (MDL) and the stability were improved by reducing the effect of laser power drift by means of the 2f/1f-WMS technique. A MDL of ~1.2 parts per billion (ppbv) for 2f-WMS and ~1.0 ppbv for 2f/1f-WMS were achieved, respectively, with a measurement time of 4 s. The MDL was further improved from 299 pptv (@108 s for 2f-WMS) to 239 pptv (@208 s for 2f/1f-WMS), based on an Allan deviation analysis.The rise time (@0 → 100 ppbv) and fall time (@100 → 0 ppbv) were determined to be ~64 s and ~48 s,respectively, at a gas pressure of <100 Torr for the C 2 H 6 sensor operation.

03 NATURAL GAS↗

A surface acoustic wave hydrogen sensor with tin doped indium oxide layers for intermediate temperatures

We report high temperature surface acoustic wave (SAW) gas sensors with conducting sensing layers require tuning of the sheet conductivity for optimal response. Conducting metal oxides are attractive sensing materials for their tunable electronic properties and high thermal stability, amongst others. Here, we have investigated the application of indium oxide (IO) and indium tin oxide (ITO) films on langasite (LGS)-based SAW reflective delay line sensor devices for monitoring hydrogen at 350 °C. Specifically, we modeled the effect of the IO and ITO sensing layer thickness on the wave velocity, attenuation, and effective electromechanical coefficient. This was followed by an experimental demonstration of tuning of the ITO film sheet conductivity by controlling the dopant concentration and yielding an improvement in the sensor sensitivity. The current study provides a pathway towards the development of conductivity-based sensing layers for high temperature SAW gas sensors with improved sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Performance Atomically-Thin Room-Temperature NO 2 Sensor

The development of room-temperature sensing devices for detecting small concentrations of molecular species is imperative for a wide range of low-power sensor applications. Here, we demonstrate a room-temperature, highly sensitive, selective, and reversible chemical sensor based on a monolayer of the transition metal dichalcogenide Re 0.5 Nb 0.5 S 2 . The sensing device exhibits thickness dependent carrier type, and upon exposure to NO 2 molecules, its electrical resistance considerably increases or decreases depending on the layer number. The sensor is selective to NO 2 with only minimal response to other gases such as NH 3 , CH 2 O, and CO 2 . In the presence of humidity, not only are the sensing properties not deteriorated, but also the monolayer sensor shows complete reversibility with fast recovery at room temperature. We present a theoretical analysis of the sensing platform and identify the atomically-sensitive transduction mechanism.

47 OTHER INSTRUMENTATION↗

Determining ionizing radiation using sensors based on organic semiconducting material

The use of organic semiconducting material sensors as total dose radiation detectors is proposed, wherein the change in conductivity of an organic material is measured as a function of ionizing radiation dose. The simplest sensor is a resistor made using organic semiconductor. Furthermore, for achieving higher sensitivity, organic field effect transistor (OFET) is used as a sensor. A solution processed organic semiconductor resistor and an OFET were fabricated using poly 3-hexylthiophene (P3HT), a p-type organic semiconductor material. The devices are exposed to Cobalt-60 radiation for different total dose values. The changes in electrical characteristics indicate the potential of these devices as radiation sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic bead counter using a micro-Hall sensor for biological applications

Micro-Hall sensors have been fabricated, and various numbers of micron-size magnetic beads have been placed within the sensor area. The Hall resistances measured at room temperature are found to be proportional to the number of the beads, and are in good agreement with the numerically simulated results presented in this study. Our sensors are designed to measure the number of beads between zero and full-scale signals for a given number range of interest. The effects of miniaturizing the beads and sensors to nanoscale are also discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Modeling The Influence Of H{sub 2}O On Metal Oxide Sensor Responses To CO

It is well know that the relative humidity largely affects the response of MOX gas sensors to the target gases. The influence of water vapor on MOX sensor operation has been deeply studied and many results can be found in the literature. Nevertheless the effect of water was not incorporated in the sensor models presented up to now. In this work the authors propose, on the basis of experimental evidence, a simplified model for SnO{sub 2} sensors, able to account for the water contribution, when the target gas is CO. The authors start from a model already presented and tested for dry gases (CO and O{sub 2}), and add the water contribution, assuming that the direct reaction between CO and water can be neglected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two Analyte Calibration From The Transient Response Of Potentiometric Sensors Employed With The SIA Technique

Calibration models for multi-analyte electronic tongues have been commonly built using a set of sensors, at least one per analyte under study. Complex signals recorded with these systems are formed by the sensors' responses to the analytes of interest plus interferents, from which a multivariate response model is then developed. This work describes a data treatment method for the simultaneous quantification of two species in solution employing the signal from a single sensor. The approach used here takes advantage of the complex information recorded with one electrode's transient after insertion of sample for building the calibration models for both analytes. The departure information from the electrode was firstly processed by discrete wavelet for transforming the signals to extract useful information and reduce its length, and then by artificial neural networks for fitting a model. Two different potentiometric sensors were used as study case for simultaneously corroborating the effectiveness of the approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ring-type electric current sensor based on ring-shaped magnetoelectric laminate of epoxy-bonded Tb{sub 0.3}Dy{sub 0.7}Fe{sub 1.92} short-fiber/NdFeB magnet magnetostrictive composite and Pb(Zr, Ti)O{sub 3} piezoelectric ceramic

A ring-type electric current sensor operated in vortex magnetic field detection mode is developed based on a ring-shaped magnetoelectric laminate of an axially polarized Pb(Zr, Ti)O{sub 3} (PZT) piezoelectric ceramic ring bonded between two circumferentially magnetized epoxy-bonded Tb{sub 0.3}Dy{sub 0.7}Fe{sub 1.92} (Terfenol-D) short-fiber/NdFeB magnet magnetostrictive composite rings. The electric current sensitivity of the sensor was evaluated, both theoretically and experimentally. The sensor showed a high nonresonance sensitivity of {approx}12.6 mV/A over a flat frequency range of 1 Hz-30 kHz and a large resonance sensitivity of 92.2 mV/A at the fundamental shape resonance of 67 kHz, besides an excellent linear relationship between the input electric current and the output magnetoelectrically induced voltage. The power-free, bias-free, high-sensitive, and wide-bandwidth natures of the sensor make it great potential for real-time condition monitoring of engineering systems having electric current-carrying cables or conductors.

36 MATERIALS SCIENCE↗

FIBER BRAGG GRATING SENSORS FOR LOCALIZED STRAIN MEASUREMENTS AT LOW TEMPERATURE AND IN HIGH MAGNETIC FIELD

Study of magnetostrictive effects in the bulk superconductors is very essential and can give more knowledge about the effects like namely, flux pinning induced strain, pincushion distortions in the magnets and so on. Currently used electro mechanical sensors are magnetic field dependent and can only give the global stress/strain information but not the local stress/strains. But the information like radius position dependent strain and characterisation of shape distortion in non cylindrical magnets are interesting. Wavelength encoded multiplexed fiber Bragg Grating sensors inscribed in one fiber gives the possibility to measure magentostrictive effects spatially resolved in low temperature and high magnetic field. This paper specifies the design and technology requirements to adapt FBG sensors for such an application. Also reports the experiments demonstrate the properties of glass FBG at low temperature (4.2 K) and the results of strain measurement at 4.2 K/8 T. The sensor exhibits a linear wavelength change for the strain change.

42 ENGINEERING↗

Damage Detection of CFRP Plates by Full-Spectral Analysis of a Fibre Bragg Grating Sensor Signal

This paper describes the measurement of average strain, strain distribution and vibration of cantilever beam made of Carbon Fiber Reinforced Plastics (CFRP), using a single Fibre Bragg Grating (FBG) sensor mounted on the beam surface. Average strain is determined from the displacement of the peak wavelength of reflected light from the FBG sensor. Unstrained reference FBG sensors were used to compensate for temperature drift and the photoelastic coefficient (P{sub e}), which was used to calculate the gauge factor. Measured strains agree with those measured by a resistance foil strain gauge attached to the sample. Stress distributions are measured by monitoring the variation in the full width half maximum (FWHM) values of the reflected spectrum, using a proposed optical analytical model, described in the paper. FWHM values were measured for both the cantilever test beam and a for a reference beam, loaded using a four-point bending rig. The trend of the stress distribution for the test beam matches with our analytical model, however with a relatively large noise present in the experimentally determined data. The vibration of cantilever beam was measured by temporal analysis of the peak reflection wavelength. This technique is very stable as measurements are not affected by variations in the signal amplitude. Finally an application of FBG sensors for damage detection of CFRP plates is demonstrated, by measuring the average strain and natural frequency. With small defects of different sizes applied to the CFRP plate, average strains were seen to increase with damage size and the natural frequency decreased with damage size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planar Hall effect bridge magnetic field sensors

Until now, the planar Hall effect has been studied in samples with cross-shaped Hall geometry. We demonstrate theoretically and experimentally that the planar Hall effect can be observed for an exchange-biased ferromagnetic material in a Wheatstone bridge topology and that the sensor signal can be significantly enhanced by a geometric factor. For the samples in the present study, we demonstrate an enhancement of the sensor output by a factor of about 100 compared to cross-shaped sensors. The presented construction opens a new design and application area of the planar Hall effect, which we term planar Hall effect bridge sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Irradiation tests of ITER candidate Hall sensors using two types of neutron spectra

We report on irradiation tests of InSb based Hall sensors at two irradiation facilities with two distinct types of neutron spectra. One was a fission reactor neutron spectrum with a significant presence of thermal neutrons, while another one was purely fast neutron field. Total neutron fluence of the order of 10{sup 16} cm{sup -2} was accumulated in both cases, leading to significant drop of Hall sensor sensitivity in case of fission reactor spectrum, while stable performance was observed at purely fast neutron spectrum. This finding suggests that performance of this particular type of Hall sensors is governed dominantly by transmutation. Additionally, it further stresses the need to test ITER candidate Hall sensors under neutron flux with ITER relevant spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Room Temperature ppb Level Chlorine Gas Sensor Based on Copper (II) 1, 4, 8, 11, 15, 18, 22, 25-octabutoxy-29 H, 31 H-phthalocyanine Films

Spin coating technique has been used to fabricate room temperature chlorine gas sensor based on copper (II) 1, 4, 8, 11, 15, 18, 22, 25-octabutoxy-29 H, 31 H-phthalocyanine (CuPc(OBu){sub 8}) films. Gas sensor shows a response of 185% to few parts per billion level of Cl{sub 2} gas with response time of 9.5 minutes at room temperature. The interactions between sensor and analytes followed first order kinetics with rate constant 0.01{<=}k{<=}0.02. The chemiresistive sensor showed very good stability at room temperature over a long period of time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗