Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

System for Packaging Planetary Samples for Return to Earth

A system is proposed for packaging material samples on a remote planet (especially Mars) in sealed sample tubes in preparation for later return to Earth. The sample tubes (Figure 1) would comprise (1) tubes initially having open tops and closed bottoms; (2) small, bellows-like collapsible bodies inside the tubes at their bottoms; and (3) plugs to be eventually used to close the tops of the tubes. The top inner surface of each tube would be coated with solder. The side of each plug, which would fit snugly into a tube, would feature a solder-filled ring groove. The system would include equipment for storing, manipulating, filling, and sealing the tubes. The containerization system (see Figure 2) will be organized in stations and will include: the storage station, the loading station, and the heating station. These stations can be structured in circular or linear pattern to minimize the manipulator complexity, allowing for compact design and mass efficiency. The manipulation of the sample tube between stations is done by a simple manipulator arm. The storage station contains the unloaded sample tubes and the plugs before sealing as well as the sealed sample tubes with samples after loading and sealing. The chambers at the storage station also allow for plug insertion into the sample tube. At the loading station the sample is poured or inserted into the sample tube and then the tube is topped off. At the heating station the plug is heated so the solder ring melts and seals the plug to the sample tube. The process is performed as follows: Each tube is filled or slightly overfilled with sample material and the excess sample material is wiped off the top. Then, the plug is inserted into the top section of the tube packing the sample material against the collapsible bellowslike body allowing the accommodation of the sample volume. The plug and the top of the tube are heated momentarily to melt the solder in order to seal the tube.

Badescu, Mircea↗

Multi-omics Characterization of the Host Response to COVID-19

This project is a multi-disciplinary collaboration between investigators at PNNL with expertise in mass spectrometry (MS)-based omics technology development, omics measurement methods development and application, statistics, machine learning and integration of disparate datasets for a systems-level understanding, and expertise in pathogenic coronaviruses, and investigators at the University of Wisconsin-Madison (UW-Madison) with expertise in pathogenic respiratory viruses (e.g. influenza). The goal of this project is to obtain a comprehensive picture of the human host factors critical for the outcome of SARS-CoV-2 infection. We will generate broad untargeted multi-omics profiles using both state-of-the-art and novel instrumentation and approaches to enable the identification of the molecular mechanisms and host response pathways that impact human COVID-19 outcomes. We anticipate these results will lead to the generation of biomarker panels that are predictive of disease outcomes and mechanistic hypotheses that can be further interrogated in future studies and will provide the basis for vaccine or therapeutic development. To do so, we are obtaining and analyzing blood samples from COVID-19 patients with a range of disease outcomes that were treated at the Center Hospital of the National Center for Global Health and Medicine in Tokyo, Japan and other collaborating hospitals in our network. Specifically, this project will fund proteomics and metabolomics analyses of clinical COVID samples, machine learning-based integration of the data, and pathway-based interpretation of the data. This project was funded in June 2020. In the time span of June to September 2020, the project team developed an analytically and statistically robust analysis plan and made various preparations to facilitate sample receipt from our UW-Madison collaborators. This included blocking and randomization of sample prep orders, ordering of reagents and reference materials, and shipping of materials needed for preparation of the samples under BSL3 conditions to our collaborators at UW-Madison. As of FY21, this project has been picked up via a sponsor, the Naval Medical Research Center, which will cover the remainder of the proposed scope of work.

60 APPLIED LIFE SCIENCES↗

High-Field One-Dimensional and Two-Dimensional 27Al Magic-Angle Spinning Nuclear Magnetic Resonance Study of ?-, d-, and ?-Al2O3 Dominated Aluminum Oxides: Toward Understanding the Al Sites in ?-Al2O3

Herein, a detailed analysis was carried out using high-field (19.9 T) 27Al magic-angle spinning (MAS) nuclear magnetic resonance (NMR) on three specially prepared aluminum oxide samples where the ?-, d-, and ?-Al2O3 phases are dominantly expressed through careful control of the synthesis conditions. Specifically, two-dimensional (2D) multiquantum (MQ) MAS 27Al was used to obtain high spectral resolution, which provided a guide for analyzing quantitative 1D 27Al NMR spectra. Six aluminum sites were resolved in the 2D MQ MAS NMR spectra, and seven aluminum sites were required to fit the 1D spectra. A set of octahedral and tetrahedral peaks with well-defined quadrupolar line shapes was observed in the ?-phase dominant sample and was unambiguously assigned to the ?-Al2O3 phase. The distinct line shapes related to the ?-Al2O3 phase provided an opportunity for effectively deconvoluting the more complex spectrum obtained from the d-Al2O3 dominant sample, allowing the peaks/quadrupolar parameters related to the d-Al2O3 phase to be extracted. The results show that the d-Al2O3 phase contains three distinct AlO sites and three distinct AlT sites. This detailed Al site structural information offers a powerful way of analyzing the most complex ?-Al2O3 spectrum. It is found that the ?-Al2O3 phase consists of Al sites with local structures similar to those found in the d-Al2O3 and ?-Al2O3 phases albeit with less ordering. Spin–lattice relaxation time measurement further confirms the disordering of the lattice. Collectively, this study uniquely assigns 27Al features in transition aluminas, offering a simplified method to quantify complex mixtures of aluminum sites in transition alumina samples.

Xu, Suochang↗

Autonomous Science Decision Making for Mars Sample Return

In the near future NASA intends to explore Mars in preparation for a sample return mission using robotic devices such as landers, rovers, orbiters, airplanes, and/or balloons. Such platforms will likely carry imaging devices to characterize the surface morphology, and a variety of analytical instruments intended to evaluate the chemical and mineralogical nature of the environment(s) that they encounter. Historically, mission operations have involved the following sequence of activities: (1) return of scientific data from the vehicle; (2) evaluation of the data by space scientists; (3) recommendations of the scientists regarding future mission activity; (4) transmission of commands to the vehicle to achieve this activity; and (5) new activity by the vehicle in response to those commands. This is repeated for the duration of the mission, with command opportunities once or perhaps twice per day. In a rapidly changing environment, such as might be encountered by a rover traversing hundreds of meters a day or an airplane soaring over several hundred of kilometers, this traditional cycle of data evaluation and commands is not amenable to rapid long range traverses, discovery of novelty, or rapid response to any unanticipated situations. In addition, to issues of response time, the nature of imaging and/or spectroscopic devices are such that tremendous data volumes can be acquired, for example during a traverse. These data volumes can rapidly exceed on-board memory capabilities prior to an opportunity to transmit it to Earth.

Roush, Ted L.↗

Autonomous Science Decisions for Mars Sample Return

In the near future NASA intends to explore Mars in preparation for a sample return mission using robotic devices such as landers rovers, orbiters, airplanes, and/or balloons. Such platforms will likely carry imaging devices to characterize the surface morphology, and a variety of analytical instruments intended to evaluated the chemical and mineralogical nature of the environment(s) that they encounter. Historically, mission operations have involved the following sequence of activities: (1) return of scientific data from the vehicle; (2) evaluation of the data by space scientists; (3) recommendations of the scientists regarding future mission activity; (4) transmission of commands to the vehicle to achieve this activity; and (5) new activity by the vehicle in response to those commands.

Roush, T. L.↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

Early Navigation Performance of the OSIRIS-REx Approach to Bennu

The New Frontiers-class OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, Security-Regolith Explorer) mission is the first American endeavor to return a sample from an asteroid. In preparation for retrieving the sample, OSIRIS-REx is conducting a campaign of challenging proximity-operations maneuvers and scientific observations, bringing the spacecraft closer and closer to the surface of near-Earth asteroid (101955) Bennu. Ultimately, the spacecraft will enter a 900-meter-radius orbit about Bennu and conduct a series of reconnaissance flybys of candidate sample sites before being guided into contact with the surface for the Touch and Go sample collection event. Between August and December 2018, the OSIRIS-REx team acquired the first optical observations of Bennu and used them for navigation. We conducted a series of maneuvers with the main engine, Trajectory Correction Maneuver, and Attitude Control System thruster sets to slow the OSIRIS-REx approach to Bennu and achieve rendezvous on December 3, 2018. This paper describes the trajectory design, navigation conops, and key navigation results from the Approach phase of the OSIRIS-REx mission.

Antreasian, Peter G.↗

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

Optical vibrational spectroscopic signatures of ammonium diuranate process parameters

Ammonium diuranate (ADU) is commonly encountered in the nuclear fuel cycle; however, previous investigations have shown that ADU is a complex mixture of distinct compounds. Moreover, production parameters are known to heavily influence the composition of the resulting ADU. Here, we examine four samples of ADU prepared at Oak Ridge National Laboratory (ORNL), and one sample of ADU made at Pacific Northwest National Laboratory (PNNL), with the goal of further characterizing and elucidating the effect of processing parameters such as stir rate, strike direction, and temperature on material composition. Process parameters during ADU precipitation at ORNL and PNNL were well documented, and we relate process variables to optical vibrational spectroscopic signatures observed using Raman and infrared (IR) spectroscopy. In addition, powder X-ray diffraction (PXRD) reveals differences in the solid-phase composition of ADU precipitates, but we find that the primary phase is similar to the uranyl oxyhydroxyhydrate mineral metaschoepite. Despite the significant phase contributions of a metaschoepite-like phase, spectroscopic evidence of both nitrate and ammonium are observed for all samples. To gain a more holistic understanding of spectroscopic features of process parameters in ADU, principal component analysis (PCA) is employed and results in observable signatures that relate to the stir rate used during synthesis. These results provide further information about the process-dependence of ADU precipitate composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scattering of light from particulate surfaces. I - A laboratory assessment of multiple-scattering effects

In planetary applications it is sometimes important to know the degree to which multiple scattering is influencing the photometric properties of a surface. An investigation is conducted concerning the point at which the single-scattering approximation used in the theory developed by Hapke (1963) and Irvine (1966) breaks down. It is shown that the Hapke-Irvine photometric function provides an adequate representation of the scattering properties of particulate surfaces whose geometric albedos (or normal reflectances) do not exceed 0.3. An experiment is conducted to estimate the normal reflectance below which the Hapke-Irvine equation considered provides an adequate representation of the scattering properties of a particulate surface. The investigation makes use of a set of samples which were prepared by mixing magnesium oxide and charcoal powders. The samples have a range in normal reflectance from 0.04 to 1.04.

Veverka, J.↗

The Remote Sensing of Mineral Aerosols and their Impact on Phytoplankton Productivity

The overall objective of this experiment was to test the iron hypothesis does the addition of iron to nutrient rich surface waters enhance productivity? Our specific objectives in this experiment included sampling and studying the marine aerosol size and type (which are related to chemical reactivity) during the PlumEx cruise to determine the importance of local (Galapagos Islands) versus long-range sources of atmospheric material. Detailed results of single particle analysis of our samples are being prepared for publication in two papers. We collect aerosol samples and they have been analyzed for trace metals and other elements. We are mapped aerosol distribution and the desert source areas around the Arabian Sea region. We did record a clear relationship between the aerosol radiance and synoptic weather patterns with distinct signals over the ocean northwest and southwest of Australia. While the interpretation was limited an aerosol climatology pattern was presented.

Tindale, Neil W.↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

A Howardite-Eucrite-Diogenite (HED) Meteorite Compendium: Summarizing Samples of ASteroid 4 Vesta in Preparation for the Dawn Mission

The Howardite-Eucrite-Diogenite (HED) suite of achondritic meteorites, thought to originate from asteroid 4 Vesta, has recently been summarized into a meteorite compendium. This compendium will serve as a guide for researchers interested in further analysis of HEDs, and we expect that interest in these samples will greatly increase with the planned arrival of the Dawn Mission at Vesta in August 2011. The focus of this abstract/poster is to (1) introduce and describe HED samples from both historical falls and Antarctic finds, and (2) provide information on unique HED samples available for study from the Antarctic Meteorite Collection at JSC, including the vesicular eucrite PCA91007, the olivine diogenite EETA79002, and the paired ALH polymict eucrites.

Garber, J. M.↗

A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth

In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.

Viso, M.↗

Hydrocarbon group type determination in jet fuels by high performance liquid chromatography

Results are given for the analysis of some jet and diesel fuel samples which were prepared from oil shale and coal syncrudes. Thirty-two samples of varying chemical composition and physical properties were obtained. Hydrocarbon types in these samples were determined by fluorescent indicator adsorption (FIA) analysis, and the results from three laboratories are presented and compared. Recently, rapid high performance liquid chromatography (HPLC) methods have been proposed for hydrocarbon group type analysis, with some suggestion for their use as a replacement of the FIA technique. Two of these methods were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.

Antoine, A. C.↗

Electromechanical Materials for Cryogenic Use

Electromechanical materials can be used in smart sensor and actuator devices. Yet none performing at low temperatures are available. To meet this need, Pb((MgNi)(1/3)Ta(2/3))03 was synthesized as an electrostrictive ceramic for applications in cryogenic environments. Employing the columbite precursor route, samples with 0% to 100% Ni substitution for Mg were prepared, but only samples with Ni-substitutions less than or equal to 20% yielded primarily the desired perovskite phase. For these compositions the temperature of highest permittivity decreased linearly with increasing Ni content to yield a minimum value of -124 C for 20% Ni-substitution. This composition showed good relaxor dielectric behavior with a maximum relative permittivity of 5890 at 1 kHz. Additionally, in samples with excess MgO, the magnitude of permittivity doubled. In this effort, Pb((MgNi)(1/3)Ta(2/3))03 (PMNiTa) was fabricated to lower its transition temperature by substituting Ni for Mg successively.

Leidinger, Peter↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemometrics and visible diffuse reflectance spectroscopy to classify plutonium dioxide

Diffuse reflectance (DR) spectra in the Vis-NIR (∼380–1050 nm) region were acquired for a series of PuO 2 samples with a spot size of about 10 × 10 μm. Two batches of six PuO 2 samples, synthesized approximately 7.5 months apart, were prepared using both Pu(III) and Pu(IV) oxalate precursors at three distinct calcination temperatures (450, 650, and 950 °C). This yielded a total of 12 PuO 2 samples and 433 DR spectra. The DR spectrum of PuO 2 contained numerous peaks in the visible region, and characteristic features were identified with respect to calcination temperature and chemistry. A distinct peak multiplet near 615 nm was observed for samples prepared at low calcination temperatures, and a peak near 660 nm was observed for higher calcination temperatures. A multivariate classification strategy based on principal component analysis (PCA) was developed to distinguish PuO 2 calcination temperatures of 450, 650, and 950 °C with 100 % accuracy. Classification results also indicate the potential to distinguish chemical processing history (i.e., Pu(III) or Pu(IV)) based on the spectra with 72 % accuracy based on k-nearest neighbors applied to the PCA scores. Partial least squares discriminant analysis was used to identify variation among batches with 88 % accuracy and found that peaks near 669, 681, 811, and 970 nm were the most useful for predicting the batch identity. Here, this work demonstrates how micro-diffuse reflectance spectroscopy and chemometrics can be used to classify PuO 2 processing history based on Vis-NIR spectral features. Combining the chemometric approach with mapping sequences could provide a rapid, nondestructive approach to classify Pu oxide materials for environmental, forensics, and nonproliferation applications.

Actinide↗