Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Emissivity measurements of shocked tin using a multi-wavelength integrating sphere

Pyrometric measurements of radiance to determine temperature have been performed on shock physics experiments for decades. However, multi-wavelength pyrometry schemes sometimes fail to provide credible temperatures in experiments, which incur unknown changes in sample emissivity, because an emissivity change also affects the spectral radiance. Hence, for shock physics experiments using pyrometry to measure temperatures, it is essential to determine the dynamic sample emissivity. The most robust way to determine the normal spectral emissivity is to measure the spectral normal-hemispherical reflectance using an integrating sphere. In this paper we describe a multi-wavelength (1.6–5.0 μm) integrating sphere system that utilizes a “reversed” scheme, which we use for shock physics experiments. The sample to be shocked is illuminated uniformly by scattering broadband light from inside a sphere onto the sample. A portion of the light reflected from the sample is detected at a point 12° from normal to the sample surface. For this experiment, we used the system to measure emissivity of shocked tin at four wavelengths for shock stress values between 17 and 33 GPa. The results indicate a large increase in effective emissivity upon shock release from tin when the shock is above 24–25 GPa, a shock stress that partially melts the sample. We also recorded an IR image of one of the shocked samples through the integrating sphere, and the emissivity inferred from the image agreed well with the integrating-sphere, pyrometer-detector data. Here, we discuss experimental data, uncertainties, and a data analysis process. We also describe unique emissivity-measurement problems arising from shock experiments and methods to overcome such problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Andra's Underground Research Laboratory as a Tool to Prepare Monitoring System of Cigeo Project - 18070

Andra, as French radioactive waste management agency, plans to build an underground disposal facility, named Cigeo, dedicated to high and intermediate level, long lived radioactive wastes. To ensure the safety during the disposal operations that includes the principle of reversibility, the design of the associated monitoring system will be based on specific research and development program and feedback obtained over more than 15 years on tests performed in representative conditions. Andra's Underground Research Laboratory (URL), located at 500 m deep, is excavated in a clay-rich formation. It is dedicated to (i) assess the thermo-hydro-mechanical, chemical and radiologic behaviors of the rock and supporting layers (concrete and steel), (ii) test envisaged monitoring system, (iii) provide feedback on operational organization and safety management and (iv) qualify operating methods (digging, concrete pouring, monitoring system design, etc.) to be implemented in the future disposal. Data collected from (i) characteristics of samples retrieved from boreholes, (ii) experts' observations, (iii) sensors installed in situ and (iv) manual measurements, are integrated in a database. This database is dedicated to samples management (more than 73 600 classified samples), data measurements collection, and conversion to physical values and available to plots or exports. Each day, approximately 1.6 million of values are integrated in the database. Finally, a geo-referenced database is linked to the main database in order to allow the spatial localization, both on the surface or in the underground galleries. All these tools give confidence in Andra's capacity to monitor Cigeo and be ready for the future industrial pilot phase. The monitoring system will also allow, step by step, optimizing the disposal design, performing regular safety control, helping in decision making for reversibility and improving long term safety. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understandig the role of heavy ion-irradiation induced surface columnar nanostructures through FESEM imaging.

In this paper we report on the effects of 'surface columnar defects' (blind holes) generated by heavy ion irradiation by performing Field Emission Scanning Electron Microscopy (FESEM) imaging of the columns created across a selected set of specimens, ranging from YBa{sub 2}Cu{sub 3}O{sub 7-x} melt-textured bulks and Bi{sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub x} monofilamentary tapes to YBa{sub 2}Cu{sub 3}O{sub 7-x} single crystals. Different ion fluences, resulting into modifying the superconducting properties, were sampled. A correlation between FESEM patterns and volume integrated measurements shows how surface columnar defects claim the leadership of the superconducting behaviors of the ion implanted samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

Element-specific visualization of dynamic magnetic coupling in a Co/Py bilayer microstructure

We present the element-specific and time resolved visualization of uniform ferromagnetic resonance excitations of a Permalloy (Py) disk–Cobalt (Co) stripe bilayer microstructure. The transverse high frequency component of the resonantly excited magnetization is sampled in the ps regime by a combination of ferromagnetic resonance (FMR) and scanning transmission X-ray microscopy (STXM-FMR) recording snapshots of the local magnetization precession of Py and Co with nanometer spatial resolution. The approach allows us to individually image the resonant dynamic response of each element, and we find that angular momentum is transferred from the Py disk to the Co stripe and vice versa at their respective resonances. The integral (cavity) FMR spectrum of our sample shows an unexpected additional third resonance. This resonance is observed in the STXM-FMR experiments as well. Our microscopic findings suggest that it is governed by magnetic exchange between Py and Co, showing for the Co stripe a difference in relative phase of the magnetization due to stray field influence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-integrated activity coefficient estimation for radionuclide therapy using PET and a pharmacokinetic model: A simulation study on the effect of sampling schedule and noise

Purpose: The aim of this study was to investigate the accuracy of PET-based treatment planning for predicting the time-integrated activity coefficients (TIACs). Methods: The parameters of a physiologically based pharmacokinetic (PBPK) model were fitted to the biokinetic data of 15 patients to derive assumed true parameters and were used to construct true mathematical patient phantoms (MPPs). Biokinetics of 150 MBq {sup 68}Ga-DOTATATE-PET was simulated with different noise levels [fractional standard deviation (FSD) 10%, 1%, 0.1%, and 0.01%], and seven combinations of measurements at 30 min, 1 h, and 4 h p.i. PBPK model parameters were fitted to the simulated noisy PET data using population-based Bayesian parameters to construct predicted MPPs. Therapy simulations were performed as 30 min infusion of {sup 90}Y-DOTATATE of 3.3 GBq in both true and predicted MPPs. Prediction accuracy was then calculated as relative variability v{sub organ} between TIACs from both MPPs. Results: Large variability values of one time-point protocols [e.g., FSD = 1%, 240 min p.i., v{sub kidneys} = (9 ± 6)%, and v{sub tumor} = (27 ± 26)%] show inaccurate prediction. Accurate TIAC prediction of the kidneys was obtained for the case of two measurements (1 and 4 h p.i.), e.g., FSD = 1%, v{sub kidneys} = (7 ± 3)%, and v{sub tumor} = (22 ± 10)%, or three measurements, e.g., FSD = 1%, v{sub kidneys} = (7 ± 3)%, and v{sub tumor} = (22 ± 9)%. Conclusions: {sup 68}Ga-DOTATATE-PET measurements could possibly be used to predict the TIACs of {sup 90}Y-DOTATATE when using a PBPK model and population-based Bayesian parameters. The two time-point measurement at 1 and 4 h p.i. with a noise up to FSD = 1% allows an accurate prediction of the TIACs in kidneys.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An unattended device for high-voltage sampling and passive measurement of thoron decay products

An integrating measurement device for the concentration of airborne thoron decay products was designed and calibrated. It is suitable for unattended use over up to several months also in inhabited dwellings. The device consists of a hemispheric capacitor with a wire mesh as the outer electrode on ground potential and the sampling substrates as the inner electrode on +7.0 kV. Negatively charged and neutral thoron decay products are accelerated to and deposited on the sampling substrates. As sampling substrates, CR39 solid-state nuclear track detectors are used in order to record the alpha decay of the sampled decay products. Nuclide discrimination is achieved by covering the detectors with aluminum foil of different thickness, which are penetrated only by alpha particles with sufficient energy. Devices of this type were calibrated against working level monitors in a thoron experimental house. The sensitivity was measured as 9.2 tracks per Bq/m{sup 3} × d of thoron decay products. The devices were used over 8 weeks in several houses built of earthen material in southern Germany, where equilibrium equivalent concentrations of 1.4–9.9 Bq/m{sup 3} of thoron decay products were measured.

54 ENVIRONMENTAL SCIENCES↗

DENSITY ESTIMATION FOR PROJECTED EXOPLANET QUANTITIES

Exoplanet searches using radial velocity (RV) and microlensing (ML) produce samples of 'projected' mass and orbital radius, respectively. We present a new method for estimating the probability density distribution (density) of the unprojected quantity from such samples. For a sample of n data values, the method involves solving n simultaneous linear equations to determine the weights of delta functions for the raw, unsmoothed density of the unprojected quantity that cause the associated cumulative distribution function (CDF) of the projected quantity to exactly reproduce the empirical CDF of the sample at the locations of the n data values. We smooth the raw density using nonparametric kernel density estimation with a normal kernel of bandwidth {sigma}. We calibrate the dependence of {sigma} on n by Monte Carlo experiments performed on samples drawn from a theoretical density, in which the integrated square error is minimized. We scale this calibration to the ranges of real RV samples using the Normal Reference Rule. The resolution and amplitude accuracy of the estimated density improve with n. For typical RV and ML samples, we expect the fractional noise at the PDF peak to be approximately 80 n{sup -log2}. For illustrations, we apply the new method to 67 RV values given a similar treatment by Jorissen et al. in 2001, and to the 308 RV values listed at exoplanets.org on 2010 October 20. In addition to analyzing observational results, our methods can be used to develop measurement requirements-particularly on the minimum sample size n-for future programs, such as the microlensing survey of Earth-like exoplanets recommended by the Astro 2010 committee.

79 ASTRONOMY AND ASTROPHYSICS↗

STOCHASTIC STAR FORMATION AND A (NEARLY) UNIFORM STELLAR INITIAL MASS FUNCTION

Recent observations indicate a lower H{alpha} to FUV ratio in dwarf galaxies than in brighter systems, a trend that could be explained by a truncated and/or steeper initial mass function (IMF) in small galaxies. However, at low star formation rates (SFRs), the H{alpha} to FUV ratio can vary due to stochastic sampling even for a universal IMF, a hypothesis that has, prior to this work, received limited investigation. Using SLUG, a fully stochastic code for synthetic photometry in star clusters and galaxies, we compare the H{alpha} and FUV luminosity in a sample of {approx}450 nearby galaxies with models drawn from a universal Kroupa IMF and a modified IMF, the integrated galactic initial mass function (IGIMF). Once random sampling and time evolution are included, a Kroupa IMF convolved with the cluster mass function (CMF) reproduces the observed H{alpha} distribution at all FUV luminosities, while a truncated IMF as implemented in current IGIMF models underpredicts the H{alpha} luminosity by more than an order of magnitude at the lowest SFRs. We conclude that the observed luminosity is the result of the joint probability distribution function of the SFR, CMF, and a universal IMF, consistent with parts of the IGIMF theory, but that a truncation in the IMF in clusters is inconsistent with the observations. Future work will examine stochastic star formation and its time dependence in detail to study whether random sampling can explain other observations that suggest a varying IMF.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the top-quark decay width and mass at CDF using the template method.

Measurements of the top quark decay width and mass are presented using the tt events produced in p p collisions at Fermilab's Tevatron collider and collected by the CDF II detector. A data sample corresponding to 4.3 fb -1 of integrated luminosity is used for the top quark width measurement. Two estimators, the reconstructed top quark mass and the mass of hadronically decaying W boson that comes from the top-quark decay are reconstructed for each event and compared with templates of different input top quark widths and deviations from nominal CDF jet energy scale (ΔJES) to perform a simultaneous fit for both parameters. ΔJES is used for the in situ calibration of the jet energy scale at CDF. By applying a Feldman-Cousins limit-setting approach, we establish an upper limit at 95% confidence level (CL) of Γtop < 7.6 GeV and a two-sided 68% CL interval of (0.3 GeV, 4.4) GeV assuming a top quark mass of 172.5 GeV/c 2 , which are consistent with the standard model prediction. The measurement of the top quark mass uses a data sample of tt events in 5.7 fb -1 of integrated luminosity collected by the same detector. Candidate events in the top quark mass measurement are required to have large missing transverse energy, no identified charged leptons, and four, five, or six jets with at least one jet tagged as coming from a b quark. This analysis considers events from the semileptonic tt decay channel, including events that contain tau leptons. The measurement is based on a multidimensional template method, in a similar way to the top quark width measurement, and the top quark mass is measured to be Mtop = 172.32 ± 2.37 ± 0.98 GeV/c 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A GALEX ULTRAVIOLET IMAGING SURVEY OF GALAXIES IN THE LOCAL VOLUME

We present results from a GALEX ultraviolet (UV) survey of a complete sample of 390 galaxies within {approx}11 Mpc of the Milky Way. The UV data are a key component of the composite Local Volume Legacy, an ultraviolet-to-infrared imaging program designed to provide an inventory of dust and star formation in nearby spiral and irregular galaxies. The ensemble data set is an especially valuable resource for studying star formation in dwarf galaxies, which comprise over 80% of the sample. We describe the GALEX survey programs that obtained the data and provide a catalog of far-UV ({approx}1500 A) and near-UV ({approx}2200 A) integrated photometry. General UV properties of the sample are briefly discussed. We compute two measures of the global star formation efficiency, the star formation rate (SFR) per unit H I gas mass, and the SFR per unit stellar mass, to illustrate the significant differences that can arise in our understanding of dwarf galaxies when the FUV is used to measure the SFR instead of H{alpha}. We find that dwarf galaxies may not be as drastically inefficient in converting gas into stars as suggested by prior H{alpha} studies. In this context, we also examine the UV properties of late-type dwarf galaxies that appear to be devoid of star formation because they were not detected in previous H{alpha} narrowband observations. Nearly all such galaxies in our sample are detected in the FUV and have FUV SFRs that fall below the limit where the H{alpha} flux is robust to Poisson fluctuations in the formation of massive stars. Otherwise, the UV colors and star formation efficiencies of H{alpha}-undetected, UV-bright dwarf irregulars appear to be relatively unremarkable with respect to those exhibited by the general population of star-forming galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Results Of Routine Strip Effluent Hold Tank, Decontaminated Salt Solution Hold Tank, And Caustic Wash Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 4 Operations

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), and Caustic Wash Tank (CWT) samples from several of the "microbatches" of Integrated Salt Disposition Project (ISDP) Salt Batch ("Macrobatch") 4 have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by inductively-coupled plasma emission spectroscopy (ICPES). Furthermore, samples from the CWT have been analyzed by a variety of methods to investigate a decline in the decontamination factor (DF) of the cesium observed at MCU.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Results of Accelerated Stress Testing on Single-Channel and Multichannel Drivers: Solid-State Lighting Technology Area

This report is the first in a series of studies on accelerated stress testing (AST) of drivers used for SSL luminaires, such as downlights, troffers, and streetlights. A representative group of two-stage commercial driver products was exposed to an AST environment consisting of 75°C and 75% relative humidity (7575). These drivers were a mix of single-channel drivers (i.e., a single output current for one LED primary) and multichannel drivers (i.e., separate output currents for multiple LED primaries). This AST environment was chosen because previous testing on downlights with integrated drivers demonstrated that 38% of the sample population failed in less than 2,500 hours of testing using this method. In addition to AST test results, the performance of an SSL downlight product incorporating an integrated, multichannel driver during extended room temperature operational life (RTOL) testing is also reported. A battery of measurements was used to evaluate these products during accelerated testing, including full electrical characterization (i.e., power consumption, PF, total harmonic distortion [THD], and inrush current) and photometric characterization of external LED loads attached to the drivers (i.e., flicker performance and lumen maintenance).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved Management of the Technical Interfaces Between the Hanford Tank Farm Operator and the Hanford Waste Treatment Plant - 13383

The Department of Energy (DOE) is constructing the Waste Treatment and Immobilization Plant (WTP) at the Hanford site in Washington to treat and immobilize approximately 114 million gallons of high level radioactive waste (after all retrievals are accomplished). In order for the WTP to be designed and operated successfully, close coordination between the WTP engineering, procurement, and construction contractor, Bechtel National, Inc. and the tank farms operating contractor (TOC), Washington River Protection Solutions, LLC, is necessary. To develop optimal solutions for DOE and for the treatment of the waste, it is important to deal with the fact that two different prime contractors, with somewhat differing contracts, are tasked with retrieving and delivering the waste and for treating and immobilizing that waste. The WTP and the TOC have over the years cooperated to manage the technical interface. To manage what is becoming a much more complicated interface as the WTP design progresses and new technical issues have been identified, an organizational change was made by WTP and TOC in November of 2011. This organizational change created a co-located integrated project team (IPT) to deal with mutual and interface issues. The Technical Organization within the One System IPT includes employees from both TOC and WTP. This team has worked on a variety of technical issues of mutual interest and concern. Technical issues currently being addressed include: - The waste acceptance criteria; - Waste feed delivery and the associated data quality objectives (DQO); - Evaluation of the effects of performing a riser cut on a single shell tank on WTP operations; - The disposition of secondary waste from both TOC and WTP; - The close coordination of the TOC double shell tank mixing and sampling program and the Large Scale Integrated Test (LSIT) program for pulse jet mixers at WTP along with the associated responses to the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2; - Development of a set of alternatives to the current baseline that involve aspects of direct feed, feed conditioning, and design changes. The One System Technical Organization has served WTP, TOC, and DOE well in managing and resolving issues at the interface. This paper describes the organizational structure used to improve the interface and several examples of technical interface issues that have been successfully addressed by the new organization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SDSS-IV/MaNGA: SPECTROPHOTOMETRIC CALIBRATION TECHNIQUE

Mapping Nearby Galaxies at Apache Point Observatory (MaNGA), one of three core programs in the Sloan Digital Sky Survey-IV, is an integral-field spectroscopic survey of roughly 10,000 nearby galaxies. It employs dithered observations using 17 hexagonal bundles of 2″ fibers to obtain resolved spectroscopy over a wide wavelength range of 3600–10300 Å. To map the internal variations within each galaxy, we need to perform accurate spectral surface photometry, which is to calibrate the specific intensity at every spatial location sampled by each individual aperture element of the integral field unit. The calibration must correct only for the flux loss due to atmospheric throughput and the instrument response, but not for losses due to the finite geometry of the fiber aperture. This requires the use of standard star measurements to strictly separate these two flux loss factors (throughput versus geometry), a difficult challenge with standard single-fiber spectroscopy techniques due to various practical limitations. Therefore, we developed a technique for spectral surface photometry using multiple small fiber-bundles targeting standard stars simultaneously with galaxy observations. We discuss the principles of our approach and how they compare to previous efforts, and we demonstrate the precision and accuracy achieved. MaNGA's relative calibration between the wavelengths of Hα and Hβ has an rms of 1.7%, while that between [N ii] λ6583 and [O ii] λ3727 has an rms of 4.7%. Using extinction-corrected star formation rates and gas-phase metallicities as an illustration, this level of precision guarantees that flux calibration errors will be sub-dominant when estimating these quantities. The absolute calibration is better than 5% for more than 89% of MaNGA's wavelength range.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the tt production cross section in pp collisions at {radical}(s)=1.96 TeV using soft electron b-tagging

We present a measurement of the top-quark pair-production cross section in pp collisions at {radical}(s)=1.96 TeV using a data sample corresponding to 1.7 fb{sup -1} of integrated luminosity collected with the Collider Detector at Fermilab. We reconstruct tt events in the lepton+jets channel, consisting of e{nu}+jets and {mu}{nu}+jets final states. The dominant background is the production of W bosons in association with multiple jets. To suppress this background, we identify electrons from the semileptonic decay of heavy-flavor jets (''soft electron tags''). From a sample of 2196 candidate events, we obtain 120 tagged events with a background expectation of 51{+-}3 events, corresponding to a cross section of {sigma}{sub tt}=7.8{+-}2.4(stat){+-}1.6(syst){+-}0.5(lumi) pb. We assume a top-quark mass of 175 GeV/c{sup 2}. This is the first measurement of the tt cross section with soft electron tags in run II of the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Smart Vision-Aided RICH (Robotic Interface Control and Handling) System for VULCAN

High-flux neutron beams and high-efficiency detectors enable rapid neutron diffraction measurements at the Engineering Materials Diffractometer (VULCAN) at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL). To optimize beam time utilization, efficient sample exchange, alignment, and automated measurements are essential. Recent advances in artificial intelligence (AI) have expanded the capabilities of robotic systems. Here, we report the development of a Robotic Interactive Control and Handling (RICH) system for sample handling at VULCAN, designed to support high-throughput experiments and reduce overhead time. The RICH system employs a six-axis desktop robot integrated with AI-based computer vision models capable of recognizing and localizing samples in real time from instrument and depth-resolving cameras. Vision algorithms combine these detections to align samples with designated measurement positions or place them within complex sample environments such as furnaces. This integration of machine learning-assisted vision with robotic handling demonstrates the feasibility of autonomous sample detection and preparation, offering a pathway toward fully unmanned neutron scattering experiments.

automation↗

Cryosectioning-enhanced super-resolution microscopy for single-protein imaging across cells and tissues

DNA-points accumulation for imaging in nanoscale topography (DNA-PAINT) enables nanoscale imaging with virtually unlimited multiplexing and molecular counting. Here, we address challenges, such as variable imaging performance and target accessibility, that can limit its broader applicability. Specifically, we enhance its capacity for robust single-protein imaging and molecular counting by optimizing the integration of total internal reflection fluorescence microscopy with physical sectioning, in particular, Tokuyasu cryosectioning. Our method, tomographic and kinetically enhanced DNA-PAINT (tkPAINT), achieves 3 nm localization precision across diverse samples, enhanced imager binding, and improved cellular integrity. tkPAINT can facilitate molecular counting with DNA-PAINT inside the nucleus, as demonstrated through its quantification of the in situ abundance of RNA Polymerase II in both HeLa cells as well as mouse tissues. Anticipating that tkPAINT could become a versatile tool for the exploration of biomolecular organization and interactions across cells and tissues, we also demonstrate its capacity to support multiplexing, multimodal targeting of proteins and nucleic acids, and three-dimensional (3D) imaging.

Science & Technology - Other Topics↗

The Atacama Cosmology Telescope: A search for late-time anisotropic screening of the Cosmic Microwave Background

Since the formation of the first stars, most of the gas in the Universe has been ionized. Spatial variations in the density of this ionized gas generate cosmic microwave background anisotropies via Thomson scattering, a process known as the ``anisotropic screening'' effect. We propose and implement for the first time a new estimator to cross-correlate unWISE galaxies and anisotropic screening, as measured by the Atacama Cosmology Telescope and Planck satellite. We do not significantly detect the effect; the null hypothesis is consistent with the data at 1.7 $σ$ (resp. 0.016 $σ$) for the blue (resp. green) unWISE sample. We obtain an upper limit on the integrated optical depth within a 6 arcmin disk to be $\barτ< 0.033$ arcmin$^2$ at 95% confidence for the blue sample and $\barτ< 0.057$ arcmin$^2$ for the green sample. Future measurements with Simons Observatory and CMB-S4 should detect this effect significantly. Complementary to the kinematic Sunyaev-Zel'dovich effect, this probe of the gas distribution around halos will inform models of feedback in galaxy formation and baryonic effects in galaxy lensing.

79 ASTRONOMY AND ASTROPHYSICS↗