Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Test of nuclear decay rate variation due to an antineutrino flux

Unexplained variations of the decay rate parameter for weak interaction decays such as β ± decay, electron capture, as well as strong interaction α decay have been reported. Because these variations have been presented by a number of groups, at various locations, using various types of detectors, different isotopes, and over extended periods of time, some researchers have interpreted the source of these variations as not from ambient environmental factors such as temperature, pressure, and humidity but via an unexplained fundamental interaction. The state of decay rate parameter variations experiments is reviewed, and the reported results are placed into a common comparable context by defining a phenomenological cross section. After that we make decay parameter measurements as a function of time at the level of 10 -5 in the presences of an antineutrino flux with an on-off cycle time of ≈ 30 days. This level of precision requires a detailed understanding of both systematic and statistical errors; otherwise, systematic errors in the measurement may mimic the decay events of fundamental interactions. The experiment searched for variation of the $^{54}_{25}$Mn, e - capture decay rate parameter and $^{137}_{55}$Cs, β - decay rate parameter both to a level of precision of 1 part in ≈10 5 by comparing the difference between the decay rate in the presence of an antineutrino flux ≈ 3 x 10 12 $\bar{ν}$ cm -2 s -1 and no flux measurements. The experiment was located 6.53 m from the reactor core of the High Flux Isotope Reactor at the Oak Ridge National Laboratory. Two weak interaction decays, one via electron capture and the other via β - decay, were selected because the final state and the time reverse state each contain a neutrino and antineutrino, covering arguments that the antineutrino flux may interact differently or not at all in one of the cases. The $\gamma$ spectra from both decays were collected and analyzed independently. The measured variation in the decay rate parameters are found to be δλ/λ =(0.034 ± 1.38) x10 -5 for $^{54}_{25}$Mn and δλ/λ =(0.67±1.56) x10 -5 for $^{137}_{55}$Cs. These results are consistent with no measurable decay rate parameter variation due to an antineutrino flux, yielding a 68% confidence level upper limit sensitivity for $^{54}_{25}$Mn δλ/λ ≤ 1.31 x 10 -5 or σ ≤ 1.29 x10 -25 cm 2 in cross section and for $^{137}_{55}$Cs δλ/λ ≤ 2.23 x 10 -5 or σ ≤ 5.69 x10 -27 cm 2 . The cross-section upper limit obtained in these null or no observable effect measurements are ≈ 10 4 times more sensitive than past experiments reporting positive results in 54 Mn and 137 Cs. . .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved $^{95}\mathrm{Mo}$ neutron resonance parameters and astrophysical reaction rates

We report improved 95 Mo neutron resonance parameters and reaction rates are important for nuclear astrophysics, testing nuclear models, and nuclear criticality safety. However, despite many previous neutron-capture and total cross-section measurements on this nuclide, there still is much room for improvement as well as several discrepancies. For example, there are very few firm resonance spin and parity assignments; average resonance parameters are available only for each parity, the currently recommended astrophysical reaction rate results in disagreements between stellar models and meteoric isotopic anomalies, and there are substantial disagreements in the neutron-capture cross section at low energies important for nuclear criticality safety. To obtain an improved set of neutron resonance parameters and astrophysical reaction rates for 95 Mo. High-resolution neutron-capture and transmission data were measured at the Oak Ridge Electron Linear Accelerator (ORELA) using highly isotopically enriched 95 Mo samples. The neutron-capture apparatus, data reduction, and analysis were improved so that information contained in the γ-ray cascade following neutron capture were used to assign resonance J π values. Following this, simultaneous analysis of the new neutron-capture and transmission data was used to obtain resonance energies, gamma widths, and neutron widths and their uncertainties to a maximum energy of 10 keV. Accurate neutron-capture cross sections also were obtained for the unresolved resonance region to a maximum energy of 500 keV and, together with the new resonance parameters, used to calculate the astrophysical reaction rates in the temperature range from 5 to 30 keV. A vastly improved set of 95Mo neutron resonance parameters and an astrophysical reaction rate accurate to about 3% were obtained. Firm J π assignments were determined for 261 of the 314 observed resonances. This is a very large improvement over the previously published 32 firm J π assignments for 108 resonances. Also, the number of resonances having both firm J π assignments and Γ γ values was increased by almost a factor of 24—from 11 to 261. Neutron- and total-radiation-width distributions and average resonance spacings, average total radiation widths, and neutron strength functions were obtained for the six different s- and p-wave possibilities. Parameters for the lowest s-wave resonance, which is most important for criticality benchmarks, were obtained with high accuracy. Simple modification of the neutron-capture apparatus and expansion and improvement of data analysis techniques led to a large increase in firm J π assignments for 95 Mo neutron resonances. The resulting astrophysical reaction rate is 20%–30% larger than the currently recommended rate at s-process temperatures, which should lead to better agreement between stellar models and meteoric isotopic anomalies. The neutron-capture cross section at low energies is substantially larger than recommended in the latest evaluation, which is problematical for criticality benchmarks. The average resonance spacing as a function of spin and parity is significantly different from current models. The total-radiation-width distributions are significantly broader than predicted by theory and show significant departures from the expected Gaussian shapes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Matching of experimental and statistical-model thermonuclear reaction rates at high temperatures

We address the problem of extrapolating experimental thermonuclear reaction rates toward high stellar temperatures (T>1 GK) by using statistical model (Hauser-Feshbach) results. Reliable reaction rates at such temperatures are required for studies of advanced stellar burning stages, supernovae, and x-ray bursts. Generally accepted methods are based on the concept of a Gamow peak. We follow recent ideas that emphasized the fundamental shortcomings of the Gamow peak concept for narrow resonances at high stellar temperatures. Our new method defines the effective thermonuclear energy range (ETER) by using the 8th, 50th, and 92nd percentiles of the cumulative distribution of fractional resonant reaction rate contributions. This definition is unambiguous and has a straightforward probability interpretation. The ETER is used to define a temperature at which Hauser-Feshbach rates can be matched to experimental rates. This matching temperature is usually much higher compared to previous estimates that employed the Gamow peak concept. We suggest that an increased matching temperature provides more reliable extrapolated reaction rates since Hauser-Feshbach results are more trustwhorthy the higher the temperature. Our ideas are applied to 21 (p,{gamma}), (p,{alpha}), and ({alpha},{gamma}) reactions on A=20-40 target nuclei. For many of the cases studied here, our extrapolated reaction rates at high temperatures differ significantly from those obtained using the Gamow peak concept.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the solar neutrino capture rate with gallium metal. III. Results for the 2002-2007 data-taking period

The Russian-American experiment SAGE began to measure the solar neutrino capture rate with a target of gallium metal in December 1989. Measurements have continued with only a few brief interruptions since that time. In this article we present the experimental improvements in SAGE since its last published data summary in December 2001. Assuming the solar neutrino production rate was constant during the period of data collection, combined analysis of 168 extractions through December 2007 gives a capture rate of solar neutrinos with energy more than 233 keV of 65.4{sub -3.0}{sup +3.1} (stat) {sub -2.8}{sup +2.6} (syst) SNU. The weighted average of the results of all three Ga solar neutrino experiments, SAGE, Gallex, and GNO, is now 66.1{+-}3.1 SNU, where statistical and systematic uncertainties have been combined in quadrature. During the recent period of data collection a new test of SAGE was made with a reactor-produced {sup 37}Ar neutrino source. The ratio of observed to calculated rates in this experiment, combined with the measured rates in the three prior {sup 51}Cr neutrino-source experiments with Ga, is 0.87{+-}0.05. A probable explanation for this low result is that the cross section for neutrino capture by the two lowest-lying excited states in {sup 71}Ge has been overestimated. If we assume these cross sections are zero, then the standard solar model including neutrino oscillations predicts a total capture rate in Ga in the range of 63 SNU to 66 SNU with an uncertainty of about 4%, in good agreement with experiment. We derive the current value of the neutrino flux produced in the Sun by the proton-proton fusion reaction to be {phi}{sub pp}{sup {center_dot}}=(6.0{+-}0.8)x10{sup 10}/(cm{sup 2} s), which agrees well with the pp flux predicted by the standard solar model. Finally, we make several tests and show that the data are consistent with the assumption that the solar neutrino production rate is constant in time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Kramers formula for the fission rate versus dynamical modeling: The case of deformation-dependent temperature

We have derived approximate analytical formulas describing the quasistationary fission rate of excited nuclei (the Kramers rates). These rates are compared with those resulting from dynamical modeling using the Smoluchowski equation (the dynamical rates). Contrary to the original Kramers approach, we have accounted for the microcanonical nature of the fission process. The influence of the potential at the scission point on the fission rates is also studied. Comparison with the dynamical rates enables us to define the accuracy of the Kramers rates in the wide range of the ratio of the fission barrier height B{sub f} to the temperature at the quasistationary state T{sub c} up to 16. These high values are not reachable within the traditional Langevin approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct evaluation of dynamical large-deviation rate functions using a variational ansatz

We describe a simple form of importance sampling designed to bound and compute large-deviation rate functions for time-extensive dynamical observables in continuous-time Markov chains. We start with a model, defined by a set of rates, and a time-extensive dynamical observable. We construct a reference model, a variational ansatz for the behavior of the original model conditioned on atypical values of the observable. Direct simulation of the reference model provides an upper bound on the large-deviation rate function associated with the original model, an estimate of the tightness of the bound, and, if the ansatz is chosen well, the exact rate function. The exact rare behavior of the original model does not need to be known in advance. We use this method to calculate rate functions for currents and counting observables in a set of network- and lattice models taken from the literature. Straightforward ansätze yield bounds that are tighter than bounds obtained from Level 2.5 of large deviations via approximations that involve uniform scalings of rates. Here, we show how to correct these bounds in order to recover the rate functions exactly. Our approach is complementary to more specialized methods and offers a physically transparent framework for approximating and calculating the likelihood of dynamical large deviations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collisional damping rates for electron plasma waves reassessed

Collisional damping of electron plasma waves, the primary damping for high phase velocity waves, is proportional to the electron-ion collision rate, ν ei,th . Here in this work, it is shown that the damping rate normalized to ν ei,th depends on the charge state, Z, on the magnitude of ν ei,th and the wave number k in contrast with the commonly used damping rate in plasma wave research. Only for weak collision rates in low-Z plasmas for which the electron self-collision rate is comparable to the electron-ion collision rate is the damping rate given by the commonly accepted value. The result presented here corrects the result presented in textbooks at least as early as 1973. Lastly, the complete linear theory requires the inclusion of both electron-ion pitch-angle and electron-electron scattering, which itself contains contributions to both pitch-angle scattering and thermalization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dose Rate Effects in the Aging of Nuclear Cable Insulation Subjected to Gamma Radiation

In nuclear power plants (NPPs), the aging of polymer-based electrical cable insulation must be effectively monitored to ensure the safe and reliable operation of NPPs. Gamma radiation is one of the main environmental stressors causing degradation of cable insulation. For a given total dose of absorbed gamma radiation, damage due to gamma irradiation may be dose rate dependent. The purpose of this work is to confirm whether a dose rate effect exists for the cable insulation made by crosslinked polyethylene (XLPE) and ethylene propylene rubber (EPR), quantify the relationship between degradation rate and dose rate, and explore the correlation of different measured properties. The dose rate effects at 1800 Gy/h, 200 Gy/h, and 100 Gy/h using 60Co gamma irradiation on cable aging was studied. Different types of cable insulation, including two XLPEs and one EPR, were irradiated at the different dose rates with a total dose around 300 kGy at 26 °C. The properties of unirradiated and irradiated samples were characterized by mass change, yellowness index, and other ongoing measurements. Dose rate effects were observed for mass change data of XLPE and EPR.

Li, Donghui↗

Variation in stem mortality rates determines patterns of above-ground biomass in Amazonian forests: implications for dynamic global vegetation models

Understanding the processes that determine above-ground biomass (AGB) in Amazonian forests is important for predicting the sensitivity of these ecosystems to environmental change and for designing and evaluating dynamic global vegetation models (DGVMs). AGB is determined by inputs from woody productivity [woody net primary productivity (NPP)] and the rate at which carbon is lost through tree mortality. Here, we test whether two direct metrics of tree mortality (the absolute rate of woody biomass loss and the rate of stem mortality) and/or woody NPP, control variation in AGB among 167 plots in intact forest across Amazonia. We then compare these relationships and the observed variation in AGB and woody NPP with the predictions of four DGVMs. The observations show that stem mortality rates, rather than absolute rates of woody biomass loss, are the most important predictor of AGB, which is consistent with the importance of stand size structure for determining spatial variation in AGB. The relationship between stem mortality rates and AGB varies among different regions of Amazonia, indicating that variation in wood density and height/diameter relationships also influences AGB. In contrast to previous findings, we find that woody NPP is not correlated with stem mortality rates and is weakly positively correlated with AGB. Across the four models, basin-wide average AGB is similar to the mean of the observations. However, the models consistently overestimate woody NPP and poorly represent the spatial patterns of both AGB and woody NPP estimated using plot data. In marked contrast to the observations, DGVMs typically show strong positive relationships between woody NPP and AGB. Resolving these differences will require incorporating forest size structure, mechanistic models of stem mortality and variation in functional composition in DGVMs.

54 ENVIRONMENTAL SCIENCES↗

The Effect of Heat Treatments and Coatings on the Outgassing Rate of Stainless Steel Chambers

The outgassing rates of four nominally identical 304L stainless steel vacuum chambers were measured to determine the effect of chamber coatings and heat treatments. One chamber was coated with titanium nitride (TiN) and one with amorphous silicon (a-Si) immediately following fabrication. One chamber remained uncoated throughout, and the last chamber was first tested without any coating, and then coated with a-Si following a series of heat treatments. The outgassing rate of each chamber was measured at room temperatures between 15 and 30 deg C following bakes at temperatures between 90 and 400 deg C. Measurements for bare steel showed a significant reduction in the outgassing rate by more than a factor of 20 after a 400 deg C heat treatment (3.5 x 10{sup 12} TorrL s{sup -1}cm{sup -2} prior to heat treatment, reduced to 1.7 x 10{ sup -13} TorrL s{sup -1}cm{sup -2} following heat treatment). The chambers that were coated with a-Si showed minimal change in outgassing rates with heat treatment, though an outgassing rate reduced by heat treatments prior to a-Si coating was successfully preserved throughout a series of bakes. The TiN coated chamber exhibited remarkably low outgassing rates, up to four orders of magnitude lower than the uncoated stainless steel. An evaluation of coating composition suggests the presence of elemental titanium which could provide pumping and lead to an artificially low outgassing rate. The outgassing results are discussed in terms of diffusion-limited versus recombination-limited processes.

43 PARTICLE ACCELERATORS↗

The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking

Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID image acquisition at the frame rate of at least 4.29 Hz is recommended. Motion blurring in the images with frame rates below 4.29 Hz can significantly reduce the accuracy of autotracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Late Quaternary slip-rate along the central Bangong-Chaxikang segment of the Karakorum fault, western Tibet

Insight into the spatial and temporal changes of slip-rate is essential to understand the kinematic role of large strike-slip faults in continental collision zones. Geodetic and geologic rates from present to several million years ago along the Karakorum fault range from 0 to 11 mm/yr. Here, we determine the first late Quaternary slip-rate at the southern end of the linear Bangong-Chaxikang segment of the Karakorum fault, using cumulative offsets (20–200 m) of fans and terraces at three sites, as well as 74 new 10 Be surface-exposure ages to constrain the age of these offset geomorphic markers. The rate is >3 mm/yr at sites Gun and Chaxikang, and it is >1.7–2.2 mm/yr at the Gar fan site. Together with rates obtained along the southernmost Menshi-Kailas segment, the Karakorum fault slip-rate seems to increase southeastward from south of Bangong Lake to Kailas (from >3 to >8 mm/yr). These Karakorum fault slip-rate data (>3–8 mm/yr), together with the total length of the fault (>1000 km) and its initiation age (>13–23 Ma), confirm that the Karakorum fault is the major fault accommodating dextral strike-slip motion NE of the western Himalayas. Furthermore, the dextral Karakorum fault in the south and the conjugate left-lateral Longmu Co–Altyn Tagh fault system in the north are thus the major strike-slip faults of western Tibet, which contribute to eastward extrusion of Tibet.

58 GEOSCIENCES↗

Membrane Thickness Impact on Chemical Degradation Rates

Abstract A comprehensive investigation of PFSA membrane chemical degradation rates as a function of thickness (8-20 µm) is reported. The two-pronged study was conducted on bare membranes and as components of chemically-mitigated and mechanically-reinforced, state-of-the-art (SOA) membrane electrode assemblies (MEAs). The bare membranes were subjected to H2O2 vapor test and MEAs were degraded under OCV conditions, both at 90°C. Both test types employed fluoride release rates (FRR) to monitor chemical degradation rates. Vapor tests revealed that area-specific degradation rates were positively correlated with membrane thickness, but thickness normalized degradation rates were independent of thickness. Open-circuit voltage (OCV) investigations spanning the membrane thickness series of MEAs was probed via a 27-experiment 3(4-1) fractional factorial experimental design. Statistical analysis of the FRR values revealed that chemical degradation rates were dominated by the relative humidity value and that the area-specific degradation rates of MEAs were independent of membrane thickness. The OCV chemical durability insensitivity to membrane thickness is supported by on-load membrane chemical durability studies at the stack level. The results suggest that ,despite smaller ionomer inventory, SOA thin membranes and MEAs are not greatly disadvantaged relative to thicker membranes from a chemical durability perspective, provided oxidative stress levels are controlled throughout application lifetime.

Coms, Frank D. (ORCID:0000000249160350)↗

Error Rate Comparison during Polymerase Chain Reaction by DNA Polymerase

As larger-scale cloning projects become more prevalent, there is an increasing need for comparisons among high fidelity DNA polymerases used for PCR amplification. All polymerases marketed for PCR applications are tested for fidelity properties (i.e., error rate determination) by vendors, and numerous literature reports have addressed PCR enzyme fidelity. Nonetheless, it is often difficult to make direct comparisons among different enzymes due to numerous methodological and analytical differences from study to study. We have measured the error rates for 6 DNA polymerases commonly used in PCR applications, including 3 polymerases typically used for cloning applications requiring high fidelity. Error rate measurement values reported here were obtained by direct sequencing of cloned PCR products. The strategy employed here allows interrogation of error rate across a very large DNA sequence space, since 94 unique DNA targets were used as templates for PCR cloning. The six enzymes included in the study, Taq polymerase, AccuPrime-Taq High Fidelity, KOD Hot Start, cloned Pfu polymerase, Phusion Hot Start, and Pwo polymerase, we find the lowest error rates with Pfu , Phusion, and Pwo polymerases. Error rates are comparable for these 3 enzymes and are >10x lower than the error rate observed with Taq polymerase. Mutation spectra are reported, with the 3 high fidelity enzymes displaying broadly similar types of mutations. For these enzymes, transition mutations predominate, with little bias observed for type of transition.

59 BASIC BIOLOGICAL SCIENCES↗

Accelerating rates of cognitive decline and imaging markers associated with β-amyloid pathology

Objective: Our objective is to estimate points along the spectrum of β-amyloid pathology at which rates of change of several measures of neuronal injury and cognitive decline begin to accelerate. Methods: In 460 patients with mild cognitive impairment (MCI), we estimated the points at which rates of florbetapir PET, fluorodeoxyglucose (FDG) PET, MRI, and cognitive and functional decline begin to accelerate with respect to baseline CSF Aβ 42 . Points of initial acceleration in rates of decline were estimated using mixed-effects regression. Results: Rates of neuronal injury and cognitive and even functional decline accelerate substantially before the conventional threshold for amyloid positivity, with rates of florbetapir PET and FDG PET accelerating early. Temporal lobe atrophy rates also accelerate prior to the threshold, but not before the acceleration of cognitive and functional decline. Conclusions: A considerable proportion of patients with MCI would not meet inclusion criteria for a trial using the current threshold for amyloid positivity, even though on average, they are experiencing cognitive/functional decline associated with prethreshold levels of CSF Aβ 42 . Lastly, future trials in early Alzheimer disease might consider revising the criteria regarding β-amyloid thresholds to include the range of amyloid associated with the first signs of accelerating rates of decline.

60 APPLIED LIFE SCIENCES↗

High-rate multiplexed entanglement source based on time-bin qubits for advanced quantum networks

Entanglement distribution based on time-bin qubits is an attractive option for emerging quantum networks. We demonstrate a 4.09-GHz repetition rate source of photon pairs entangled across early and late time bins separated by 80 ps. Simultaneous high rates and high visibilities are achieved through frequency multiplexing the spontaneous parametric down conversion output into eight time-bin entangled channel pairs. We demonstrate entanglement visibilities as high as 99.4%, total entanglement rates up to 3.55×10 6 coincidences/s, and predict a straightforward path towards achieving up to an order of magnitude improvement in rates without compromising visibility. Finally, we resolve the density matrices of the entangled states for each multiplexed channel and express distillable entanglement rates in ebit/s, thereby quantifying the trade-off between visibility and coincidence rates that contributes to useful entanglement distribution. This source is a fundamental building block for high-rate entanglement-based quantum key distribution systems or advanced quantum networks.

Mueller, Andrew (ORCID:0000000265989732)↗

A Quantitative Theory of Solid Tumor Growth, Metabolic Rate and Vascularization

The relationships between cellular, structural and dynamical properties of tumors have traditionally been studied separately. Here, we construct a quantitative, predictive theory of solid tumor growth, metabolic rate, vascularization and necrosis that integrates the relationships between these properties. To accomplish this, we develop a comprehensive theory that describes the interface and integration of the tumor vascular network and resource supply with the cardiovascular system of the host. Our theory enables a quantitative understanding of how cells, tissues, and vascular networks act together across multiple scales by building on recent theoretical advances in modeling both healthy vasculature and the detailed processes of angiogenesis and tumor growth. The theory explicitly relates tumor vascularization and growth to metabolic rate, and yields extensive predictions for tumor properties, including growth rates, metabolic rates, degree of necrosis, blood flow rates and vessel sizes. Besides these quantitative predictions, we explain how growth rates depend on capillary density and metabolic rate, and why similar tumors grow slower and occur less frequently in larger animals, shedding light on Peto’s paradox. Various implications for potential therapeutic strategies and further research are discussed.

59 BASIC BIOLOGICAL SCIENCES↗